Loading...
HomeMy WebLinkAboutMFP19005129.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP19005129 IVR Number: 19005129 Permit Informaon Permit Name:Puget Sound Energy - Electric Address/Locaon :09/23/2019Application Date:2143702150Parcel Number:415 SW 5TH PL Permit Type:09/27/2019Issue Date:Franchise Permit Work Class:09/26/2020Expiration Date:Minor Utility Job Number:101122781Franchise Type:Electric Description:Access ROW to replace padmount switch at 317955 165664. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: տ New Construction տ Repair/Relocate տ Underground տ Overhead տ Sidewalk տ Street տ Open Trench տ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 101122781 CORRIE RYDBERG (253) 234-6410 CORRIE.RYDBERG@PSE.COM 415 SW 5TH PL CREW TO REPLACE BAD ORDER PADMOUNT SWITCH AT 317955-165664 NO HS CUTS ANTICIPATED. PLEASE SEE ATTACHED ✔✔✔ Potelco, Inc. (253) 234-6410 POTELI#227PL BL005109 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.09.23 09:59:21 -07'00'9/23/19 Nathan Janders 9/23/2019 RESTORATION PER CITY OF RENTON STANDARDS MFP19005129 Scott Warlick 9/27/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: •Comply with all traffic regulations of the City of Renton and the State of Washington. •Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. •Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form 101122781 Potelco, Inc LUKE NEELY (253) 569-2523 6905 S 228th St, Kent, WA 98032 LUKE.NEELY@PSE.COM 415 SW 5TH PL TBD TBD CORRIE RYDBERG 9/23/19 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.09.23 09:59:05 -07'00' MFP19005129 8:00AM - 3:00PM Monday - Friday Scott Warlick 9/27/2019 SKETCH I -- NORTH -- I NOTES: •Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. •The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. •Approved Temporary Traffic Control Plan must be at the work site during work hours. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. •Total road closure lasting more than 24 hours is subject to the approval by the City Council. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. •The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). MAPLE AVE SW SW 5 T H P LMAPLE AVE SW S W 5 T H P L JOBSITE 8-30-19 PER LUKE NEELY CELL 253-569-2523: NOTE: RENTON PERMIT & 2 FLAGGERS REQ'D CORE HOURS, LOCATES, NO OUTAGE, VAC TRUCK, CONE OFF PARKING AREA ALONG THE STREET THE DAY BEFORE O-560011 PROBLEM: SERVICEMEN FOUND THAT UG2218 IS AN OLD AB CHANCE OIL FILLED DEADFRONT SWITCH THAT HAS NON-SERVICEABLE FUSES AND NEEDS TO BE REPLACED. AT UG2218 AT GRID 317655-165664: DEENERGIZE AND REMOVE OLD AB CHANCE OIL FILLED DEADFRONT SWITCH EXCAVATE AND REMOVE THE EXIST 5'-6.75" X 9'3" X 16" THICK LID VAC OUT THE VAULT IF NECESSARY INSTALL NEW 6'8" X 9'6" X 16" THICK LID (UV 9996204 SHOWN ON MATCAT PAGE 1025 C-22) GROUT CONDUITS, FOAM CABLES, & INSTALL EXPANDING PLUGS WHERE MISSING INSTALL NEW PME09 SWITCH PER STD 6056.1010 FIG's 1, 2, 3 (PME0915) REPLACE ANY 750 DEADBREAK AND 1/0 LOADBREAK ELBOWS AS NECESSARY RESTORE LANDSCAPING SWITCH SYSTEM TO NORMAL WITH SYSTEM OPERATOR GENERAL SPECIFICATIONS Scope of Work GAS PHONE CABLE TV N/A N/A N/A N/A N/A 108115855 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Main HP Svc/MSA THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)101122781N Vicinity Map NOT TO SCALE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Correct QC Checklist(s) reviewed. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP L. NEELY 253-569-2523 9/4/19 L. NEELY 253-569-2523 9/4/19 A. CABRERA 425-623-5379 9/4/19 N/A RENTON EAR-17 / 415 SW 5TH PL REPL B/O PME09 UG2218 415 SW 5TH PL, RENTON, 98057 ASPLUNDH CONSTRUCTION CORP. O-560011 101122781 AS NOTED 1/2 KING CSPSKERE SW 18-23N-05E 2305E071 2305E076 EAR-172305E071 11532345 101122781 Owner / Developer Contact Info officeATTN: E-Mail: Cell Phone: Project Manager Contact Information: Manager:LUKE NEELY 253-569-2523 LUKE.NEELY@PSE.COM THOMAS GUIDE 656-C5 UNDERGROUND CIRCUIT MAP SCALE: 1" = 100' MAP#: 2305E071 SITE MAP - UNIVERSAL MAP SCALE: 1" = 50' (2305E071) OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE MAP#: 2305E076 PSE No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" Luke Neely Luke Neely 253-569-2523 253-569-2523 9/5/19 9/5/19 MFP19005129 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)101122781DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP L. NEELY 253-569-2523 9/4/19 L. NEELY 253-569-2523 9/4/19 A. CABRERA 425-623-5379 9/4/19 N/A RENTON EAR-17 / 415 SW 5TH PL REPL B/O PME09 UG2218 415 SW 5TH PL, RENTON, 98057 ASPLUNDH CONSTRUCTION CORP. O-560011 101122781 AS NOTED 2/2 KING CSPSKERE SW 18-23N-05E 2305E071 2305E076 EAR-172305E071 PME0915 PADMOUNT SWITCH SCALE: NOT TO SCALE PER STD 6056.1010-FIG1 PME0915 PADMOUNT SWITCH SCALE: NOT TO SCALE PER STD 6056.1010-FIG2 PME0915 PADMOUNT SWITCH SCALE: NOT TO SCALE PER STD 6056.1010-FIG3 GOOGLE STREET VIEW OF UG2218 SCALE: NOT TO SCALE Luke Neely Luke Neely 253-569-2523 253-569-2523 9/5/19 9/5/19 AØ - 30895 BØ - 30896 CØ - 30897 3 2 1 3 2 1 1 2 3 3 2 1 CØ - 31277 BØ - 31276 AØ - 31275 AØ - 31299 BØ - 31300 CØ - 31301 CØ - 31304 BØ - 31303 AØ - 31302 PME-9 CONNECTION DIAGRAM AFTER PME-9 PADMOUNT SWITCH NOT TO SCALE 6056.1010-5 PME-9 UG2218 AØ - 30895 BØ - 30896 CØ - 30897 3 2 1 3 2 1 1 2 3 3 2 1 CØ - 31277 BØ - 31276 AØ - 31275 AØ - 31299 BØ - 31300 CØ - 31301 CØ - 31304 BØ - 31303 AØ - 31302 BEFORE OLD AB CHANCE OIL-FILLED DEADFRONT SWITCH NOT TO SCALE UG2218 150 E 150 E PME0915 PADMOUNT SWITCH SCALE: NOT TO SCALE PER STD 6056.1010-FIG3 MFP19005129 Vault415SW 5TH PLMAPLE AVE SW17 17 17 1 7FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK FROM TOTOW A W A Y A R E A PHONE 8 8 8 - 9 9 9 9 INFRASOU R C E L L C 0 0 0 0 0 0 0 0 0 0 NO PAR K I N G NO-PARK ROAD WORK AHEAD W20-1ROADWORKAHEADW20-11717 17 17 OTHER SIDES/W CLOSEDOTHER SIDE S/W CLOSED STOP FLAGGER STOP FLAGGER W20-7AW20-4ONE LANEROADAHEAD 100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'THE CREW SHALL CEASEWORK FOR A FLAGGER/SPOTTERTO ESCORT PEDESTRIANSAROUND THE WORK AREATHE CREW SHALL CEASEWORK FOR A FLAGGER/SPOTTERTO ESCORT PEDESTRIANSAROUND THE WORK AREACHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040NPSEPUGETSOUNDENERGY-O%101122781415 SW 5TH PL, RENTON WA09/12/19IRINA.REISE@PSE.COM425.424.7791SHEET 1 of 1TEMPORARY TRAFFIC CONTROL PLANNotes:1. All signs and spacing to conform to theMUTCD and City of Renon standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPVAULTVaultWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431MFP19005129