HomeMy WebLinkAboutR_4013100TENSION WIRE 8'-0" MAX END, GATE, OR 12" TYP. CORNER POST n i� n N a a a d Q < 4 Q 4 d d 4 a MID RAIL TYPICAL < _ c� <1XL U N ------ t x a d � 4 d 4d cV d 4d Q Q d' 4 Q d d 4 POST AND RAIL SPECIFICATIONS PIPE ROLL FORMED MEMBER NOM. SIZE SECTION WEIGHT (SCH. 40) (Ib/ft) END, CORNER, OR PULL POST 2 2" DIAM. OA 5.10 LINE OR BRACE POST 2" DIAM. OB 2.40 BRACE OR TOP RAIL 1 4" DIAM. OC 1.35 GATE POST 32" DIAM. FABF 2 SI 3 Y" 2 OA WHITE REFLECTIVE TAPE TYP. KLED SELVAGE d a a d ° d 4 Q 4 1 8 FENCE LINE B nnrT ( 2) C500—SE TOP RAIL TYPICAL CHAIN LINK FENCE FABRIC ° a 4 d Q 4 p •p d d d'p d. d 4 Q 4 d 4 a 1 Y" 4 L If Q UCTURAL WALL NOTES: 1. CHAIN LINK FENCE FABRIC SHALL BE BLACK VINYL COATED. RAILS AND POSTS ARE PAINTED BLACK. 2. CONCRETE POST BASES ARE 12" MINIMUM DIAMETER. 3. TENSION WIRE IS PLACED WITHIN THE LIMITS OF THE FIRST FULL FABRIC WEAVE. 4' PEDESTRIAN GUARDRAIL WITH TOP AND MID RAIL C500-2T SCALE: NTS C500-2W C500-2V 7A NOTES: 1. MONITORING WELL INSTALLATION SHALL BE PERFORMED BY BOEING APPROVED CONTRACTOR AND ALL WORK SHALL BE COORDINATED WITH BOEING ENVIRONMENTAL. 2. MONITORING WELL LOCATIONS SHALL BE FIELD ADJUSTED AS DIRECTED BY BOEING. 24" CAST IRON CAP WITH a d RUBBER GASKET d ' d 4 4 4• g °d ' d C50��E ° N 4 d ° CONCRETE �3� MONITOR WELL INSTALLATION PLAN C82 SCALE: NTS 6» EDGE OF (E) C —1d A*d� \ CAPA I v APRON R FINISHED GRADE CONCRETE WALL 1 1 4" TYP + + �a_ TYP ��' 3/8 W/(4) 1/2"0 F1554, GR 36 3/16 THREADED ROD WITH 4" EFFECTIVE EMBEDMENT DEPTH, USING SIMPSON AT-XP EPDXY ADHESIVE, TYP. SET BASE PLATE OVER 1/2" NON -SHRINK LEVELING GROUT, TYP. SECTION C500-5E SCALE: 3" = 1'-0" CAI ANI 'E c ,U LT STEEL PIVOTI RUBBER GASKET LOCKABLE WATERPROOF CAP IUT ASSEMBLY FOR PADLOCK P PLATE PVC WELL CASING (M MONITOR WELL INSTALLATION SECTION C500-5E SCALE: NTS TYPICAL PEDESTRIAN GUARDRAIL POST R-401400 C50�-5E SCALE: NTS IN COMPLIANCE WITH CITY OF RENTON STANDARDS i BergerABAM CALL 48 HOURS BEFORE YOU DIG 33301 9th Avenue South, suite 300 CIVIL PERMIT] Federal Way, Washington 98003-2600 1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �N P. THIS DESIGN B AND/OR CHECKED 06 08 18 MISCELLANEOUS DETAILS - SHEET 5 W4700331 A 12/14/18 APRON R INFRASTRUCTURE W4700331 ABAM SPT 06/08/18 T� SPT 06 08 18 SHEET w of WAsx�� G SPECIFICATION IS APPROVED A PERIMETER SECURITY FENCE W4700331 ABAM SPT 12 14 18 ® ����� ENGINEER TITLE APRON R INFRASTRUCTURE CHECKED / / � >- APPROVED BY DEPT. DATE J LC 06 08 18 C500-5E C84 &001RENTON SITE PO 31271 R�o ww JOB NO. COMP NO. AL �� clsTsa� � APPROVED ss�oN��� W4700331 APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. 4—APRON—R—0500-5E