Loading...
HomeMy WebLinkAboutR_4013124TEMPORARY SHEET PILE WALL DNR 43.4' 41.8 93.8' 10' MAX DEPTH 7' MAX DEPTH VAULT TRENCH STORM TRENCH 5' MAX DEPTH SUBGRADE IMPROVEMENTS AT PILE SUPPORTED STRUCTURE REMOVAL SECTION A SCALE: NTS DNR I 42.4' 70' MIN 303.0' 3' MAX DEPTH SLOT DRAIN - 70' MIN 0 N I C� z J O O _ m 15' 23.0' 10' Min Min 49.9' 48.1 ' 5' MAX DEPTH 5' MAX DEPTH UTILITY TRENCH DOMESTIC WATER - 7' MAX DEPTH STORM TRENCH AREA 1 TOWPATH SOUTH 10' L23.0' 15' Min Min 10' MAX DEPTH VAULT TRENCH 3' MAX DEPTH SLOT DRAIN 5' MAX DEPTH UTILITY TRENCH 7' MAX DEPTH STORM TRENCH 5' MAX DEPTH FIRE TRENCH B SECTION B - AREA 3 00-25 SCALE: NTS 135.6' 70' MIN 15' MAX 34.0' N ESMNT m 19.7' cD Z 0 J 0 0 m 15' 23.0' Min 101.6' 7' MAX DEPTH STORM TRENCH 5' MAX DEPTH FIRE TRENCH 5' MAX DEPTH UTILITY TRENCH SECTION E - AREA 3 S50�-25 SCALE: NTS SYM REVISION BY APPROVED DATE SYM APRON R INFRASTRUCTURE W47003311 ABAM I MGW 06/21/18 REVISION DNR 40.13 10' MAX DEPTH VAULT TRENCH 5' MAX DEPTH UTILITY TRENCH DNR 25' MAX 18.80 PER ESMNT 10' 23.0' 10' Min Min 58.50 5' MAX DEPTH UTILITY TRENCH 5' MAX DEPTH FIRE TRENCH 303.0' 43.4' 70' MIN 0 N TEMPORARY SHEET I PILE WALL z o J O Oco co ---- ---_____------ I 15 23.0' 10' 41.8 Min Min 48.1' 49.9' 93.8' 10' MAX DEPTH 7' MAX DEPTH 3' MAX DEPTH 5' MAX DEPTH 5' MAX DEPTH VAULT TRENCH STORM TRENCH SLOT DRAIN UTILITY TRENCH DOMESTIC WATER 7' MAX DEPTH 5' MAX DEPTH SUBGRADE IMPROVEMENTS STORM TRENCH AT PILE SUPPORTED STRUCTURE REMOVAL 3' MAX DEPTH SLOT DRAIN 10' MAX DEPTH STORM TRENCH C SECTION C - AREA 3 500-25 SCALE: NTS 257.77 148.19 1 109.6' In 70' MIN 10' 23.0' 5' MAX DEPTH Min FIRE TRENCH 3' MAX DEPTH SLOT DRAIN 7' MAX DEPTH STORM TRENCH SECTION F - AREA 2 -LJ 3UMI-1 : IN 1 J BY I APPROVED I DATE Q� BOE/NG° o'- SECTION A AREA 1 TOWPATH NORTH 500-25 SCALE: NTS CD z a W L.� 131.2' DNR I 17.9' 21.4' 70' MIN 0 oil 10' 23.0' Min --d 10' MAX DEPTH VAULT TRENCH 5' MAX DEPTH FIRE TRENCH TO BE CONSTRUCTED 5' MAX DEPTH UTILITY TRENCH DURING CLOSURE 7' MAX DEPTH STORM TRENCH (m SECTION D - AREA 3 S50�-25 SCALE: NTS 216.3' 325.9' 179.7' 136.5' N 00 1 10' 16.1' L, EXISTING z FLUME 0 m---------------------------------------------- m 5' MAX DEPTH 7' MAX DEPTH STORM TRENCH UTILITY TRENCH 5- 18" MAX DEPTH SLOT DRAIN ' MAX DEPTH FIRE TRENCH 7' MAX DEPTH STORM TRENCH v WA 2 1 x 0 28579 �SIDNAL���� ACCEPTABILITY IRGP THIS DESIGN AND/OR CHEC SPECIFICATION IS APPROVED SPT ENGII APPROVED BY DEPT. I DATE MGW SECTION G -LJ JI-HLC: IN 13 Al L SUBTITLE 06 21 18 06 21 18 TITLE 06/21 /18 CIVIL MASTER I CD z a J_ m 109.6' 70' MIN 10' 23.0' Min 3' MAX DEPTH SLOT DRAIN 10' MAX DEPTH STORM TRENCH AREA 2 CIVIL PERMIT MINIMUM CONSTRUCTION SETBACKS APRON R INFRASTRUCTURE RENTON SITE SITE N 00 1 CD z 0 J m R-4013124 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W4700331 - 06/21 /18 SHEET S500-26 S24- JOB NO. COMP NO. W4700331 RENTON, WA DWG N0. 4-APRON-R-S500-26