Loading...
HomeMy WebLinkAboutR_40131961 I E510-13 E11 1 I HARDSTAND R10 1 I V45B/4 (2)4"C, 3#600, #2/0 GND— I I D E51 -5 E1 11 I I V45B/4 I (2)4"C, 3#600, #2/0 GND I R11-1/3 1", 2 # 12 R11/19,21,23 I 1 "C, 3#10, #10 GND— E51 I 1 0-14 E111 I HARDSTAND R11 I D E51 -5 E1 11 I E510-151E111 HARDSTAND R12 D E51 -S E111 1 E510-16 LE111 HARDSTAND R13 C R13-1/3 1 "C, 2# 12 R13/19,21,23 1 "C, 3#10, #10 GND MATCH LINE, SEE SHEET E112 ' I ' I I I I I I OWS-064 I I I I I I TEMP STRUCT I I l I ACTUATOR VALVE • V-1090-18 - 7S 7-000 —10 estimated, nose poi llon I. I I' ;A • SHED I I I I I V45B/4 (2)4"C, 3#600, 2 GND I I• I • • • 11 4�j M I' I• • V45A/5 (2)4"C, 3#600, #2/0 GN r 73 7-900 —10 estimated, nose poi ,Ion 200' SHORELINE SETBACK PER CITY OF RENTON V45A/5 (2)4"C, 3#600, #2/0 GND V45B/4 B (2)4"C, 3#600, #2/0 GND E51 `4 E1 1 1 E51 (2)4"C, SPARE ---- CW ---- ---- CW --- c-----CW---- CW --- -- V45A/5 2 V45A/5 o (4)4" C, 3U600, .42/0 GND (2)4"C, 3# J0, ACTUATOR VALVE 2 ° (2)4"C SPARE 7 V45B/4 V-1076-18 —uc - - - �`" T GT - - - - - T UST - - - - 4„C� C 0 �® E51-4 E11 1 / ` MATCH LINE, SEE SHEET E110 PARTIAL POWER PLAN SCALE: 1 "=20'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A APRON R INFRASTRUCTURE W4700331 CASNE CEC 06.08.18 BOE//V� WAS L�T� 35276ST A �� ACCEPTABILITY HGG THIS DESIGN AND/OR CHE( SPECIFICATION IS APPROVED DAT ENGI ;,ROVED BY DEPT. I DATE DAT LEGEND Qo 480V, 3� MOTOR/VALVE (SIZE AS NOTED) CONCRETE MANHOLE GENERAL NOTES o 1. NO EXPOSED GALVANIZED STEEL TO BE INSTALLED C ABOVE GRADE ON APRON. PVC COATED OR PAINTED RIGID STEEL IS ACCEPTABLE. 2. COLOR CODING OF CONDUCTORS SHALL BE OBSERVED C ON ALL CIRCUITS 600 VOLTS OR LESS AS FOLLOWS: 0 3. "A" PHASE (LEFT BUS IN PANEL) 277 480VBROWN T "B" PHASE (CENTER BUS IN PANEL) ORANGE C "C" PHASE (RIGHT BUS IN PANEL) YELLOW NEUTRAL GRAY EQUIPMENT GROUND GREEN 4. FOR UNDERGROUND CONDUIT ELBOWS AND FITTINGS, CURVES LESS THAN FIVE FOOT IN RADIUS, ELECTRICAL ELLS, BENDS, AND SWEEPS SHALL BE PVC COATED GALVANIZED RIGID STEEL. STRAIGHT SECTIONS AND CURVES WITH LARGER THAN FIVE FOOT RADIUS MAY BE SCHEDULE 40 PVC. 5. UNLESS OTHERWISE SHOWN, PITCH CONDUIT AT 1 MINIMUM SLOPE TOWARDS MANHOLES. 6. A RED PLASTIC WARNING TAPE, POLYETHYLENE, 24 INCHES WIDE, WITH 4.0 MIL THICKNESS, AND CONTINUEING THE ENTIRE LENGTH OF THE UNDERGROUND CONDUITS, SHALL BE INSTALLED AT T LEAST SIX INCHES ABOVE BURIED CONDUIT AND NOT Cy SHALLOWER THAN ONE FOOT DEEP. TAPE SHALL BE CS CONTINUESLY IMPRINTED "CAUTION: BURIED C ELECTRICAL LINE BELOW" C I JG r 7. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE T SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM G 1983(91). VERTICAL DATUM: NATIONAL GEODETIC - VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM - CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. CONSTRUCTION NOTES PROVIDE AND INSTALL EQUIPMENT HARDSTAND AS SHOWN ON DETAIL DRAWINGS E510-10 THROUGH E510-17. PROVIDE AND INSTALL BURIED CONDUIT, CONDUCTORS AND ALL ANCILLIARY HARDWARE. PROVIDE AND INSTALL BURIED CONDUIT AND CONDUCTORS FOR OWS ACTUATOR VALVE. ®PROVIDE (3) 3/4" X 30' COPPER CLAD GROUND RODS AND STATIC GROUND WELL RECEPTACLES PER PLANE POSITION. CONTRACTOR TO COORDINATE WITH BOEING'S PRIME POWER GROUP FOR FINAL TESTING. PROVIDE AND INSTALL OLDCASTLE 444-LA HANDHOLE c WITH ROUND LID. SEE CIVIL DRAWINGS FOR LID LOAD T RATING. u c © PROVIDE NEMA 4X SS PULL BOX MOUNTED TO 4-20 C BUILDING EXTERIOR. SEE DETAIL 1 ON SHEET E581-1. r PROVIDE SPARE CONDUITS WITH NYLON PULL STRING T ' FROM 04-20 BUILDING TO HARDSTAND R14 VIA HAND HOLE P1. KEY PLAN 20 10 0 10 20 40 SCALE: IN FEET 41 t SUBTITLE 05.05.17 05.05.17 TITLE 05.05.17 ELECTRICAL MASTER PARTIAL POWER PLAN APRON R INFRASTRUCTURE RENTON SITE SITE SCALE: N.T.S. LAKE WASHINGTON 4-81 l�3a 1 N.STM E[r CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140 CIVIL PERMIT W4700331 J I `I 06.08.18 SHEET /� E111 E28 JOB NO. COMP NO. W4700331 RENTON, WA DWG NO. RTN-YD-El11