Loading...
HomeMy WebLinkAboutR_4013157J v ti OIEISTEAM IN CON�E E Fw �CW -- -- -- MATCH LINE, SEE SHEET M261 o N: 185597.73 1 I I/cn E: 1299383.74 IIi< U II II � o IIIQ I I o I LAKE WASHINGTON . II • 0 • N' 185589.28 �I • �I E: 1299385.92 3 oNw • -- . .�------- R14 - - ��j� 04 SI 1_11� Li L-- ---------- i S—Sis U) U) N: 185598.27 6 V81 LF 8" DI FIRE E: 1299340.30 dl Ills 20 LF 6" DI FIRE N: 185617.73 cn E: 1299335.30 2 O cn cn 0 141 LF 8" DI FIRE--\ jdl o 6"W FIRE — — — — — _ — — ——STS—STSSTS STS N: 185484.46 E: 1299223.61 � F a co ca 4.4j �� / \ m / / 00 �_ \\\� 1 \ 8 C I (ABAN) I - --- STS LU I amour O co I 0-- — \ \ I cf, ---�\ cn cn ® I\c it\ �I I I �\\\ I U S7 V r I O m SV 40 N rlI C I \ \Q ❑ I \ \ j O MC �J 2 ❑ - 00 0 w L U- � I 200' SHORELINE SETBACK I PER CITY OF RENTON I �I I � 001 � 1 N: 185325.57 1 L` - _T \,7\ CD I m I II I II II I II I I II IE 0 Iz a I� U 215 LF 8" DI WATER II � II I N: 185317.55 E: 1299313.90 m m Q a � 9 LF 8" DI WATER E: 1299318.61 I I I 2 N: 185312.54 E: 1299294.61 I I T 20 LF 8" DI WATER U \ LL 6 W FIRE 6"W FIRE —I FW FW FW W 03 Q, w W ZA I/F� 10"W FIR�"CI SD 10"W FIRE v 0I N � STS STS STS L_--------- — — — — — — — — — — — — I — — — — — — — — — — — — — w � L` I ROLLINIG DOOR PAD I I I w •co — N I L IJ o� our w mUl Q I o m 00 4-41 BUILDING m CIO w U U - I II � II cu II / I w / Qj LL " c / IU D �12"W FIRE "' �� / I� / w 0 w i� y I � I N Cn U w � °O I - — — — HPSS TO I GENERAL NOTES 1. SEE SHEET G02 FOR FIRE AND WATER SERVICE NOTES. 2. ALL FIRE LINE SHALL BE INSTALLED WITH RESTRAINED JOINTS. 3. SEE SHEET M510-2 DETAIL 3 FOR TYPICAL UTILITY TRENCH BEDDING AND BACKFILL. 4. SEE SHEET M510-2 DETAIL 5 FOR JOINT UTILITY TRENCH. 5. COORDINATE ALL DOMESTIC WATER AND FIRE WATER SHUT DOWNS REQUIRED FOR CONNECTIONS TO EXISTING WITH BOEING SITE SERVICES AND FIRE DEPARTMENT. 6. FITTINGS SHOWN FOR CONNECTIONS TO EXISTING ARE SUGGESTED. CONTRACTOR SHALL POTHOLE AND FIELD VERIFY PIPE TYPE, LOCATION, CONDITION AND ROUNDNESS PRIOR TO ORDERING MATERIALS. 7. HORIZONTAL CONTROL NOTES SHOWN ON THIS SHEET REPRESENT CENTER OF STRUCTURE, BEND OR CENTERLINE OF PIPE. 8. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 1 YARD HYDRANT AT UTILITY STAND M510-1 2� FIRE HYDRANT ASSEMBLY M 510 2 CONSTRUCTION NOTES 1 - 8" 45' BEND (RJ) C� z CONNECT TO EXISTING 8" DOMESTIC LINE AT EXISTING VALVE 1-8" RESTRAINED COUPLING SEE GENERAL NOTES m :� 1- 2" 90° BEND CD 4� 1 - 8" 90' BEND (RJ) 5 CONNECT TO EXISTING 10" MAIN 1 - 8"X1O" CUT -IN TEE (FLxMJ) 1 - 8" COUPLING ADAPTER (FL x RJ) 2 - 10" SPOOL AS REQUIRED SEE GENERAL NOTES 1- 8" COUPLING ADAPTER (RJ x FL) 1- 8"x6" REDUCER (FL) 1- 6" COUPLING ADAPTER (FL x RJ) :� EXPOSE PIPE TO NEAREST JOINT. CONTRACTOR TO CONFIRM THAT PIPE IS MECHANICAL JOINT TYPE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IF CONDITIONS DIFFER. INSTALL BLIND FLANGE AT TEE. CONTRACTOR TO NOTIFY BOEING FIRE A MINIMUM OF 48 HOURS IN ADVANCE. i C u w C' ABAND ABAND- - CW - KEY PLAN SCALE: N.T.S. SEPARATE FIRE PERMITS REQUIRED FROM RENTON �/_401302 R-4013157 REGIONAL FIRE AUTHORITY IN COMPLIANCE WITH CITY OF RENTON STANDARDS Ber erAI3AM 20 10 0 10 20 40 CALL 48 HOURS "A;01 33301 9th Avenue South, Suite 300 Iffim 11� 11�l CIVIL PERMIT BEFORE YOU DIG Federal Way, Washington 98003-2600 SCALE: IN FEET 1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �N P. HSCDESGN BND/ R CHECKED JLC 06/08/18 FIRE PROTECTION AND WATER - SHEET 1 W4700331 — 06/08/18 APRON R INFRASTRUCTURE W4700331 ABAM MGW 06/08/18 T? SPT 06/08/18 SHEET �F WAsh/�� G SPECIFICATION IS APPROVED ENGINEER TITLE APRON R INFRASTRUCTURE M260 M14 APPROVED BY DEPT. DATE JLC 06 08 18 CHECKED RENTON SITE R s�z�i o ww JOB N0. COMP N0. STsa� APPROVED W4700331 SS�oNAL APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. 4-APRON-R-M260