Loading...
HomeMy WebLinkAboutR-404908HORIZONTAL: 1"=10' 00 _Knowbelow. • 5 10 20 Call before you dig. Dial 811 NE m\\ \\"`®\\\® U w 0 w Q CD _ '35" W 50. 2' Q (V Cn 10+00 0 C.� z ME . �; • n5 n0 m K6 ALLEY - PLAN & PROFILE I O II ® I I I = � I I I I s N I I J ! I i _ 10' STORM 1 I EASEMENT 1.. 89� 04 5" W \50.02' �� 1 1 + 0 �` GATE CBf4 EY PLAN VIEW SCALE: 1 "=10' I I I I I STRUCTURE TABLE I I II I CB#4, TYPE 2-48" �I W/ STANDARD GRATE RIM = 169.88 IE=163.11 (12" W) IE=163.11 (12" N) CB#S, TYPE 1 W/ STANDARD GRATE RIM = 165.90 IE=163.30 (12" E) FOUND REBAR & CAP J OYLER LS 5524 0.14'S 0.07'W I ---\� w Q NEW ASPHALT PAVEMENT h (APPROX. 1,800 SF) EX GRADE AT CENTERLINE—\ A] FLUWLINL O STANDARD GIQATE , - 9.88 " IE _ M LO Q0N rn M CDto 0000 �O r Nto to 10+20 EX. TOPOGRAPHY/SURVEY INFORMATION NOTE: PROJECT ENGINEER DOES NOT WARRANT THAT THE TOPOGRAPHY SHOWN ON THESE DRAWINGS IS REPRESENTATIVE OF WHAT IS EXISTING AND/OR CONSTRUCTED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER TO HAVE ALL IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ENGINEER PRIOR TO WORK. UTILITIES AND UTILITY EASEMENTS FOR THIS SITE HAVE NOT BEEN RESEARCHED OR CONFIRMED. UTILITY CONFLICT NOTE - THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE Q 1-800-424-555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT PROJECT ENGINEER TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. LLEY PROFILE VIEW HORIZONTAL: 1 "= 10' VERTICAL: 1 "=5' J3NP EN GI N EERI N G 1735 POINTE WOODWORTH DR NE TACOMA, WA 98422 1 REVISED PER CITY REVIEW COMMENTS (206) 730-3348 N0. REVISION SAWCUT, MEET & MATCH EXISTING ASPHALT PAVEMENT 12+00 I I SAWCUT, MEET & MATCH EX. PAVEMENT 162.73 1 163.76 163.73 163.18��� IRI i I \ 1 162.73__-- \ o 175 •ems i 1 � / INSTALL ASPHALT TRANSITION W/ \ I 164.66 / 4'X5' LANDING AT END OF \ / 170 SIDEWALK TO STREET, PROVIDE 3' / \ i 4'X5' LANDING WIDE MIN. ADA PATH TO STREET TO MAXIMUM EXTENT FEASIBLE. / 1 4.50 -1.0 . 155 11+40 / 164:63 :.� .:....... 1 / ;n WM I � I 4' 5' WIDE CONC. I � -'� SIDEWALK I � STA. 10+25 ADA ASPHALT TRANSISTION BLOW-UP LE: 1 "=5' DAYLIGHT TO MATCH EX GRADE (3:1 TYP. OR 2:1 MAX.) EXISTING GRA V--� 12' ALLEY F " CRUSHED SURFACING 1 11 u , L TOP COURSE -SS- SS 1 7 SS SS SS — 173.08 173.68 1 173.30 ♦\ 0% SAWCUT, MEET & /d1° /- MATCH EX PAVEMENT 173.32 N � �.00 G _ G INSTALL ASPHALT TRANSITION W 4'X5' 173.40 LANDING AT END OF SIDEWALK TO TREET, ° PROVIDE 3' WIDE MIN. ADA P TH TO ' �° STREET TO MAXIMUM EXTENT FIE SIBLE. ^� �77 �o / C° 5' WIDE CONC. / SIDEWALK 173A 6 -1.0% 173.20 4'X5`: LAN ING ° b\ < 173.21 17 STA. 11+25 A�AASPHAL�TT RANSITION �BLOW-UP ADDITIONAL STRUCTURAL FILL MAY r,it A. ?' BE REQUIRED DEPENDING ON SOIL 4� pF W ASIjI CONDITIONS TYPICAL SECTION (ALLEY) °" z A SCALE: N.T.S. SURVEYED: DESIGNED: J3NP DRAWN: J3NP PT 4 17 19 PT CHECKED: J3NP BY DATE APPR --mm J3NP SCALE: 1 "=10, ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 19W/1991 DATUM �o 37819 p �� �� f 01 S S70NA L �Np 04/19/2019 CITY OF RENTON Plonning/Building/Public Works Dept. SCALE: 1 "=5' IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY , w jchavez 04/23/2019 jfarah 04/26/2019 Q C) Q SINGH & SAHOTA RESIDENCES DAM 2/11/19 112 9& 1133 N. 3 3 R D P L A C E FIELDBOOK: PEE CIVIL PERMIT _ DRAWING N0: N 33RD PLACE STREET IMPROVEMENTS R2 ALLEY -PLAN &PROFILE SHEET: OF: 2 C 6