HomeMy WebLinkAboutMFP19005275DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP19005275
IVR Number: 19005275
Permit Informaon
Permit Name:Century Link Permits
Address/Locaon :10/01/2019Application Date:7231502271Parcel Number:300 BURNETT AVE S
Permit Type:10/14/2019Issue Date:Franchise
Permit Work Class:10/13/2020Expiration Date:Major Utility
Job Number:N.526460Franchise Type:Telephone
Description:Century Link to access MH204, MH7, HH6 4, MH4 1, MH3 1, and HH2 6. All other work to be performed on private
property. Restoration per City of Renton standards.
APPROVED AS SUBMITTED
Contacts
Name Address PhoneTypeBilling
C/O QWEST CORP 1801 CALIFORNIA ST #4600
Denver, CO 80202
Applicant
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Heather Binkly
Dycom Industries dba North Sky
11770 Us Hwy 1, SUITE 101
Palm Beach Gardens, FL 33408
B: (360) 254-6920
O: (360) 450-3287
Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 7850 S TRAFTON St
TACOMA, WA 98409
Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Qwest Corp d/b/a CenturyLink
N.526460
Austin Sweeney
253-766-7549
austin.sweeney@centurylink.com
300 Burnett Ave S
CenturyLink to access MH204, MH7, HH6-4, MH4-1, MH3-1, and HH2-6.
All other work to be performed on private property.
North Sky Communications 503.582.1263
NORTHSC857Q4 BL.028638
10/1/19Austin Sweeney
MFP19005275
Scott Warlick 10/1/2019
Nathan Janders 10/14/2019
X X
ONE WAY
ONE WAY ONE WAYONE WAYTWO WAY
ONE WAY
HOUSER WAY S WILLIAMS AVE SS 4TH ST
S 3RD ST
PARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN
JOB # N.526460.C.45
PERMIT #
Legend
WORK AREA
SPOTTER
CONES
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'
ONE LANE TWO WAYTAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Designed for: CENTURYLINK
Project # N.526460.C.45Darlene DurrTraffic Control Supervisor
TCS # 011915
Approved 9/24/19
Phone 253-737-5198darlene.durr@hotmail.com
_______________________
Date:9/24/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
NOT TO SCALE
HH 6-4
35'SHOULDERTAPERWORK AREA10' X 100'
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5SHOULDERWORKW21-5200'
200'200'
200'
200'
200'
Comments:
THIS IS TO ACCESS HH 6-4THIS IS SHOULDER WORK.
SIDEWALK CLOSED AT WORK AREASPOTTER WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA.
SPEEDLIMIT
25
N
SIDEWALK CLOSEDAHEADCROSS HERER9-11(R)WILLIAMS AVE S @ S 3RD ST
HH 6-4 ACCESS
SHOULDER WORK
SIDEWALK CLOSURE
ROADWORKAHEADW20-1www.invarion.com
MFP19005275
X X
ONE WAY
ONE WAY ONE WAYONE WAYTWO WAY
ONE WAY
HOUSER WAY S WILLIAMS AVE SS 4TH ST
S 3RD ST
PARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN
JOB # N.526460.C.45
PERMIT #
Legend
CONES
WORK AREA
Arrowboard (Chevron)
FLAGGER
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'
ONE LANE TWO WAYTAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Designed for: CENTURYLINK
Project # N.526460.C.45Darlene DurrTraffic Control Supervisor
TCS # 011915
Approved 9/24/19
Phone 253-737-5198darlene.durr@hotmail.com
_______________________
Date:9/24/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
NOT TO SCALE
MH 204
115'MERGING TAPERNOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RIGHT LANECLOSEDAHEADW20-5W4-2W4-2200'
200'
200'200'
200'
200'
200'
200'
200'
200'BE PREPAREDTO STOPW20-7bW20-7aW20-7a200'200'
200'
200'
200'200'
WORK AREA11' X 135'
WORK AREA11' X 125'CLOSEDCROSSWALKR9-3XCCLOSEDCROSSWALKR9-3XCComments:
THIS IS TO ACCESS MH 204.
THIS IS A RIGHT LANE CLOSURE & SHOULDER WORK.
CROSSWALK CLOSED AT WORK AREA.FLAGGERS WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA.
SPEEDLIMIT
25
N
SHOULDERWORKW21-5WILLIAMS AVE S @ S 4TH ST
MH 204 ACCESS
RIGHT LANE CLOSURE
SHOULDER WORK
CROSSWALK CLOSURE
www.invarion.com
MFP19005275
PARKINGPARKINGPARKINGPARKINGPARKING PARKING
PARKING PARKING
PARKING PARKING
PARKING PARKING
PARKING PARKING
S 2ND ST
S 3RD STWILLIAMS AVE STRAFFIC CONTROL PLANJOB # N.381311.C.45PERMIT #
Designed for: CENTURYLINKProject # N.381311.C.45Darlene DurrTraffic Control SupervisorTCS # 008900 EXP. 4/30/19Approved 8/2/18Phone 253-737-5198darlene.durr@hotmail.com
_______________________
Date:8/2/18 Author:Darlene Durr, Traffic Control Supervisor Project:N.381311.C.45CERT:TCS # 008900 EXP 4/30/19 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm.
Legend
WORK TRUCK
Arrowboard (Chevron)
CONES
WORK AREA
SPOTTER
Plan Scale
1 : 1536 (1'' = 128')NOT TO SCALE
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'
ONE LANE TWO WAYTAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX CITY USE ONLYPRINTER SETTINGS: PAGE SIZE 8.5" X 11"/ ADVANCED: FIT TO 11" X 17" FOR CITY USENOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
115'MERGINGTAPERROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1LEFT LANECLOSEDAHEADW20-5LEFT LANECLOSEDAHEADW20-5W4-2W4-2ROADWORKAHEADW20-1ROADWORKAHEADW20-1200'
200'
200'200'
200'
200'
200'
200'
200'
200'ROADWORKAHEADW20-1MH 3-1
WORK AREA11' X 225'
Comments:
THIS IS TO ACCESS MH 3-1 LOCATED IN THE SE QUADRANT OF WILLIAMSAVE S AND S 3RD ST.THIS IS A LEFT LANE CLOSURE OF ONE WAY SOUTHBOUND WILLIAMS AVES NORTH OF S 3RD ST.SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.PARKING RESTRICTED AT WORK AREA.
WILLIAMS AVE S @ S 3RD STMH 3-1 ACCESS
SB LEFT LANE CLOSURE
25 MPH25 MPH
25 MPH SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALK SIDEWALK
SIDEWALKSIDEWALK
SIDEWALK SIDEWALK
SIDEWALK SIDEWALK
VICINITY MAP
WILLIAMS AVE S @ S 3RD ST
SPEEDLIMIT25
N
www.invarion.com
MFP19005275
X X ONE WAY
ONE WAY ONE WAYONE WAYTWO WAY
ONE WAY
HOUSER WAY S WILLIAMS AVE SS 4TH ST
S 3RD ST
25 MPH
25 MPH
25 MPH
25 MPH
25 MPH25 MPHPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLANJOB # N.381311.C.45PERMIT #
Designed for: CENTURYLINKProject # N.381311.C.45Darlene DurrTraffic Control SupervisorTCS # 008900 EXP. 4/30/19Approved 8/3/18Phone 253-737-5198darlene.durr@hotmail.com
_______________________
Date:8/3/18 Author:Darlene Durr, Traffic Control Supervisor Project:N.381311.C.45CERT:TCS # 008900 EXP 4/30/19 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm.
Legend
WORK TRUCK
WORK AREA
CONES
Arrowboard (Chevron)
FLAGGER
Plan Scale
1 : 1536 (1'' = 128')NOT TO SCALE
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'
ONE LANE TWO WAYTAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX CITY USE ONLYPRINTER SETTINGS: PAGE SIZE 8.5" X 11"/ ADVANCED: FIT TO 11" X 17" FOR CITY USECLOSEDCROSSWALKR9-3XCCLOSEDCROSSWALKR9-3XCNOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39115'MERGINGTAPERROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5W4-2W4-2LEFT LANECLOSEDAHEADW20-5LEFT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1200'ROADWORKAHEADW20-1ROADWORKAHEADW20-1W20-7aW20-7aW20-7aBE PREPAREDTO STOPW20-7b200'200'
200'
200'200'
200'
200'
200'
200'
200'
200'200'
200'200'
200'200'
MH 4-1
WORK AREA11' X 135'
WORK AREA11' X 125'
Comments:
THIS IS TO ACCESS MH 4-1 LOCATED IN THE NE QUADRANT OF WILLIAMSAVE S AND S 4TH ST.THIS IS A LEFT LANE CLOSURE OF SOUTHBOUND WILLIAMS AVE NORTHOF HOUSER WAY S AND SHOULDER WORK OF EASTBOUND S 4TH ST.CROSSWALK CLOSED AT WORK AREA.FLAGGERS WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA.
VICINITY MAP
WILLIAMS AVE S @ S 4TH ST
SPEEDLIMIT25
N
WILLIAMS AVE S @ S 4TH ST
MH 4-1 ACCESSSB LEFT LANE CLOSURE
EB SHOULDER WORK
CROSSWALK CLOSURE
www.invarion.com
MFP19005275
X X
ONE WAY
ONE WAY ONE WAYONE WAYTWO WAY
ONE WAY
HOUSER WAY S
WILLIAMS AVE SS 4TH ST
S 3RD ST
25 MPH
25 MPH
25 MPH
25 MPH
25 MPH25 MPHPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN
JOB # N.526460.C.45
PERMIT #
Designed for: CENTURYLINK
Project # N526460.C.45
Darlene DurrTraffic Control SupervisorTCS # 011915
Approved 6/12/19
Phone 253-737-5198darlene.durr@hotmail.com
_______________________
Date:6/12/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Darlene Durr
Legend
WORK AREA
CONES
SPOTTER
WORK TRUCK
Plan Scale
1 : 2468 (1'' = 206')NOT TO SCALE
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'
ONE LANE TWO WAYTAPER 50' TO 100' MAX
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
NOFROMTO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
HH 2-6
WORK AREA10' X 100'SIDEWALK CLOSEDCROSS HERER9-11a(L)SIDEWALK CLOSEDAHEAD
CROSS HERE
R9-11(R)ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5200'
200'200'
200'
200'
200'
Comments:
THIS IS TO ACCESS HH 2-6 LOCATED IN THE WEST SIDE OF WILLIAMS
AVE S SOUTH OF S 3RD ST.THIS IS SHOULDER WORK OF SOUTHBOUND WILLIAMS AVE S SOUTH
OF S 3RD ST.SIDEWALK CLOSED AT WORK AREA.SPOTTER WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA.
WILLIAMS AVE S @ S 3RD ST
HH 2-6 ACCESS
SB WEST SHOULDER WORK
WEST SIDEWALK CLOSURE
SPEEDLIMIT
25
N
35'SHOULDERTAPERwww.invarion.com
MFP19005275
COEFM s
i
te
: STTMWAFLTEUnknown
TEAAA
A AAAAAAAAAAA
AAAA
AA
AAAAAAAAA
AAAAAA
AAAAAA
AA
AA
HH
HHMHHHMH
HHHH HHHH
HH
HHHHHHHH
MHHHHH
MHHH
HHHHHH
HHHH
MHHHHHHHHHHH HHHHS 4 STS 3 STWELLS AVE
WILLIAMS AVE S
S 4 STS 3 STS 3 STS 4 STSMITHERS AVE S
S 3 STBURNETT AVES HOUSER WAYS 3 STHOUSER WAYHOUSER WAY
WELLS AVE S
SMITHERS AVE S
WILLIAMS AVE
SMITHERS AVE S BURNETT AVE SLOGAN AVE S
HHHH P-3( N.526460.C.91 - PLCF )BM60(2)PD qty 125.00UD-BM60(2)Pqty 125.00N.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS1524/25/196/17/19PATH CHANGE, ADD BORE 300 BURNETT AVE STHIS JOB WILL PROVIDE FIBER FACILITIES TOCUSTOMER BANK OF AMERICA AT 300 BURNETT AVE SLOCATED WITHIN THE RENTON WIRE CENTER.LCON: CARI AMSBAUGHLCON#: 206-358-2650AT POF MH 204 SPLICE COUNT LRE26, 111-112 TO NEW24-F. PLACE NEW 24-F THROUGH EXISTING CONDUIT TOHH 2-6. AT HH 2-6 PLACE SPLICE CASE & SPLICE COUNTTO NEW 24-F. BORE NEW 24-F TO CUSTOMER BUILDINGAND PLACE NEW EQUIPMENT.ARMORID:0321-1932057BANK OF AMERICA300 BURNETT AVE SRENTON,WA 98057LRE26,111-112FalseFalseNOTrueFalse2015-140 NSC139TO COCUST LOCATION300 BURNETT AVE SMFP19005275
UnknownTEAAAAAAA AAAAAAAAAAA
AA
HHMHMH
HHHHHH
MHMHHH HHHHHH
MHHHHH
S 4 STS 3 STWELLS AVE
S 4 STS 3 STS 3 STS 4 STS 3 STBURNETT AVE S 3 STHOUSER WAYHOUSER WAY
WILLIAMS AVE
LOGAN AVE S
HHHH P-3( N.526460.C.91 - PLCF )BM60(2)PD qty 125.00UD-BM60(2)Pqty 125.00N.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS2524/25/19TO COPOF:MH204SEE SHT 3·AT POF MH 204 SPLICE COUNTLRE26, 111-112 TO NEW 24-F·PLACE NEW 24-F THROUGHEXISTING CONDUIT TO HH2-6HH6-4MH3-1HH2-6SEE SHT 4BANK OF AMERICA300 BURNETT AVE SRENTON,WA 98057SEE SHT 5·CONTINUE TO PLACE NEW 24FTHRU HH6-4 IN EXISTINGCONDUIT·LEAVE 100' LOOP·CONTINUE TO PLACE NEW 24FTHRU MH3-1 IN EXITINGCONDUIT·AT HH2-6 PLACE SPLICE CASE·PLACE NEW 24F·SPLICE COUNT LRE26,111-112·LEAVE 100' LOOPMH7MH4-1·CONTINUE TO PLACE NEW 24FTHRU MH7 IN EXITING CONDUIT·CONTINUE TO PLACE NEW 24FTHRU MH4-1 IN EXITINGCONDUITINTERCEPTEX.UGBORE PIT #1BORE PIT #1BORE 125'AND PLACE NEW 2"CONDUIT·P-3·INTERCEPT EXISTING UGCONDUIT·BORE FROM BORE PIT #1 TOBORE PIT #2·PLACE NEW 2" CONDUIT·TRANSFER UP BUILDING 12'·PENETRATE WALL ABOVEHARD CEILING TO MPOP·PULL NEW 24F TO MPOPMFP19005275
P-1( N.526460.C.08 - PLUF )BM-OCCUPIED qty 1076.00UO24 qty 1276.00HO1(25-48) qty 2.00WUMS qty 1.00WHAP-R qty 1.00SCSCTEZ5 SE68880' 2008PC-5X12LT-216PLUFLRE26,1-144 (Fibers: 1-144)TKURE1,1-72 (Fibers: 145-216)<Unknown,0>A3DHD671'PC-5B12LT-024PLUFLRE26,101-102 (Fibers: 1-2)A,3-24 (Fibers: 3-24)<N.381311,1> SE96
A3DHDSE68 SE96690' 2018PC-5X12LT-048PLUFLRE26,1-48 (Fibers: 1-48)<Unknown,0>FY605966' 1992PC-3412LT-096PLUFLG9,1-96 (Fibers: 1-96)<Unknown,0>TEZ53280' 2008PC-5X12LT-072PLUFTKURE1,1-72 (Fibers: 1-72)<Unknown,0>FH59924' 1992PC-3412LT-096PLUFLG9,1-96 (Fibers: 1-96)<Unknown,0>A3G07966' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> ------------A3DJ2(PLCF)(2018)1-1/4-T9-OR-WT----------------------------------------MH-204[FY60][A3G02][FH59]FEED-TO COFEILD-TO CUSTOMERN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS3524/25/19TO COTO SHT 4HH2-6·AT POF MH 204 SPLICE COUNTLRE26, 111-112 FROM EXISTING216F [SE68]TO NEW 24-F[A3G02]·PLACE NEW 24-F THROUGHEXISTING CONDUIT TO HH2-6·COUNT WILL FALL TO HH2-6MFP19005275
SC[A3G07][A3G02]-------A3G02310' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> A3G07966' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> P-3( N.526460.C.08 - PLUF )WHAP-R qty 1.00BM-OCCUPIED qty 210.00UO24 qty 310.00HO1(25-48) qty 2.00HUSO(11.5X31)DH qty 1.00HH2-6FEED-TO COFEILD-TO CUSTOMERN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS4524/25/19TO COTO SHT 3MH204TO SHT 5MPOP·AT HH2-6 PLACE SPLICE CASE·PLACE NEW 24F·SPLICE COUNT LRE26,111-112FROM NEW 24F [A3G02] TONEW 24F [A3G07]·ROD AND PROOF EXISTING 2"UG FROM HH2-6 TO CUSTOMERMPOP·LEAVE 100' LOOPMFP19005275
P-2( N.526460.C.09 - INBF )BM-FDP qty 1.00BM-OCCUPIED qty 25.00UO24 qty 50.00HO1(25-48) qty 24.000125'A3G05300 BURNETT AVE SADCP-FL1-H6777NNQ-2222D(INBF)(2019)[in]LRE26,111-112 (Ports: 1-2)[DEAD]DD,3-24 (Ports: 3-24)<N.526460,1> AA WALL MOUNT BACKBOARDWLMT.01Bay(WALL MOUNT BACKBOARD), Number ... [Conn.Point]A3G0350' 2019AF-5B39LT-024INBFLRE26,111-112 (Fibers: 1-2)[DEAD]A,3-24 (Fibers: 3-24)24 PORT FDPBay Interna
ls
WALL MOUT BACKBOARD 01Floor24 PORT FDP24FN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS5524/25/19CUST BUILDING DETAIL:300 BURNETT AVE SCUSTOMER: BANK OF AMERICALCON NAME: CARI AMSBAUGHLCON PHONE: 206-358-2650ADDRESS: 300 BURNETT AVE SRENTON,WA 98057CLLI: RNTNWA01FEED FIBERS: LE26,111-112CUSTOMER TERMINAL: 300 BURNETT AVE SWFMT#: A.2619430BUILDING CLLI: RNTNWA79EQUIPMENT CLLI: RNTNWA7900WCONTINUE TO PULL NEW 24-FIBER THRUEXISTING CUSTOMER CONDUIT TO MPOPLOCATED ON 1ST FLOOR, ON EAST WALLWALL IN SERVER RM. AT MPOP. USECOUNT, LRE26,111-112 TO NEW FDPLEAVE 25' FIBER LOOP.PLACE NEW 24-PORT FDP IN MPOP.TERMINATE FIBERS LRE26,111-112 INTOFDP PORTS 1-2. TEST FIBERS END TO END.NO CLEAR PATH NEEDED. WHOLESALE.CUSTOMER TO PROVIDE 10FOOT PATCHCABLE TO NEW CIENA 3916 BEHINDEXISTING SERVER RACKMFP19005275