Loading...
HomeMy WebLinkAboutMFP19005275DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP19005275 IVR Number: 19005275 Permit Informaon Permit Name:Century Link Permits Address/Locaon :10/01/2019Application Date:7231502271Parcel Number:300 BURNETT AVE S Permit Type:10/14/2019Issue Date:Franchise Permit Work Class:10/13/2020Expiration Date:Major Utility Job Number:N.526460Franchise Type:Telephone Description:Century Link to access MH204, MH7, HH6 4, MH4 1, MH3 1, and HH2 6. All other work to be performed on private property. Restoration per City of Renton standards. APPROVED AS SUBMITTED Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Qwest Corp d/b/a CenturyLink N.526460 Austin Sweeney 253-766-7549 austin.sweeney@centurylink.com 300 Burnett Ave S CenturyLink to access MH204, MH7, HH6-4, MH4-1, MH3-1, and HH2-6. All other work to be performed on private property. North Sky Communications 503.582.1263 NORTHSC857Q4 BL.028638 10/1/19Austin Sweeney MFP19005275 Scott Warlick 10/1/2019 Nathan Janders 10/14/2019 X X ONE WAY ONE WAY ONE WAYONE WAYTWO WAY ONE WAY HOUSER WAY S WILLIAMS AVE SS 4TH ST S 3RD ST PARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN JOB # N.526460.C.45 PERMIT # Legend WORK AREA SPOTTER CONES Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX Designed for: CENTURYLINK Project # N.526460.C.45Darlene DurrTraffic Control Supervisor TCS # 011915 Approved 9/24/19 Phone 253-737-5198darlene.durr@hotmail.com _______________________ Date:9/24/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com NOT TO SCALE HH 6-4 35'SHOULDERTAPERWORK AREA10' X 100' NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5SHOULDERWORKW21-5200' 200'200' 200' 200' 200' Comments: THIS IS TO ACCESS HH 6-4THIS IS SHOULDER WORK. SIDEWALK CLOSED AT WORK AREASPOTTER WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA. SPEEDLIMIT 25 N SIDEWALK CLOSEDAHEADCROSS HERER9-11(R)WILLIAMS AVE S @ S 3RD ST HH 6-4 ACCESS SHOULDER WORK SIDEWALK CLOSURE ROADWORKAHEADW20-1www.invarion.com MFP19005275 X X ONE WAY ONE WAY ONE WAYONE WAYTWO WAY ONE WAY HOUSER WAY S WILLIAMS AVE SS 4TH ST S 3RD ST PARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN JOB # N.526460.C.45 PERMIT # Legend CONES WORK AREA Arrowboard (Chevron) FLAGGER Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX Designed for: CENTURYLINK Project # N.526460.C.45Darlene DurrTraffic Control Supervisor TCS # 011915 Approved 9/24/19 Phone 253-737-5198darlene.durr@hotmail.com _______________________ Date:9/24/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com NOT TO SCALE MH 204 115'MERGING TAPERNOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RIGHT LANECLOSEDAHEADW20-5W4-2W4-2200' 200' 200'200' 200' 200' 200' 200' 200' 200'BE PREPAREDTO STOPW20-7bW20-7aW20-7a200'200' 200' 200' 200'200' WORK AREA11' X 135' WORK AREA11' X 125'CLOSEDCROSSWALKR9-3XCCLOSEDCROSSWALKR9-3XCComments: THIS IS TO ACCESS MH 204. THIS IS A RIGHT LANE CLOSURE & SHOULDER WORK. CROSSWALK CLOSED AT WORK AREA.FLAGGERS WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA. SPEEDLIMIT 25 N SHOULDERWORKW21-5WILLIAMS AVE S @ S 4TH ST MH 204 ACCESS RIGHT LANE CLOSURE SHOULDER WORK CROSSWALK CLOSURE www.invarion.com MFP19005275 PARKINGPARKINGPARKINGPARKINGPARKING PARKING PARKING PARKING PARKING PARKING PARKING PARKING PARKING PARKING S 2ND ST S 3RD STWILLIAMS AVE STRAFFIC CONTROL PLANJOB # N.381311.C.45PERMIT # Designed for: CENTURYLINKProject # N.381311.C.45Darlene DurrTraffic Control SupervisorTCS # 008900 EXP. 4/30/19Approved 8/2/18Phone 253-737-5198darlene.durr@hotmail.com _______________________ Date:8/2/18 Author:Darlene Durr, Traffic Control Supervisor Project:N.381311.C.45CERT:TCS # 008900 EXP 4/30/19 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm. Legend WORK TRUCK Arrowboard (Chevron) CONES WORK AREA SPOTTER Plan Scale 1 : 1536 (1'' = 128')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #008900, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX CITY USE ONLYPRINTER SETTINGS: PAGE SIZE 8.5" X 11"/ ADVANCED: FIT TO 11" X 17" FOR CITY USENOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 115'MERGINGTAPERROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1LEFT LANECLOSEDAHEADW20-5LEFT LANECLOSEDAHEADW20-5W4-2W4-2ROADWORKAHEADW20-1ROADWORKAHEADW20-1200' 200' 200'200' 200' 200' 200' 200' 200' 200'ROADWORKAHEADW20-1MH 3-1 WORK AREA11' X 225' Comments: THIS IS TO ACCESS MH 3-1 LOCATED IN THE SE QUADRANT OF WILLIAMSAVE S AND S 3RD ST.THIS IS A LEFT LANE CLOSURE OF ONE WAY SOUTHBOUND WILLIAMS AVES NORTH OF S 3RD ST.SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.PARKING RESTRICTED AT WORK AREA. WILLIAMS AVE S @ S 3RD STMH 3-1 ACCESS SB LEFT LANE CLOSURE 25 MPH25 MPH 25 MPH SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALK SIDEWALK SIDEWALKSIDEWALK SIDEWALK SIDEWALK SIDEWALK SIDEWALK VICINITY MAP WILLIAMS AVE S @ S 3RD ST SPEEDLIMIT25 N www.invarion.com MFP19005275 X X ONE WAY ONE WAY ONE WAYONE WAYTWO WAY ONE WAY HOUSER WAY S WILLIAMS AVE SS 4TH ST S 3RD ST 25 MPH 25 MPH 25 MPH 25 MPH 25 MPH25 MPHPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLANJOB # N.381311.C.45PERMIT # Designed for: CENTURYLINKProject # N.381311.C.45Darlene DurrTraffic Control SupervisorTCS # 008900 EXP. 4/30/19Approved 8/3/18Phone 253-737-5198darlene.durr@hotmail.com _______________________ Date:8/3/18 Author:Darlene Durr, Traffic Control Supervisor Project:N.381311.C.45CERT:TCS # 008900 EXP 4/30/19 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm. Legend WORK TRUCK WORK AREA CONES Arrowboard (Chevron) FLAGGER Plan Scale 1 : 1536 (1'' = 128')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #008900, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX CITY USE ONLYPRINTER SETTINGS: PAGE SIZE 8.5" X 11"/ ADVANCED: FIT TO 11" X 17" FOR CITY USECLOSEDCROSSWALKR9-3XCCLOSEDCROSSWALKR9-3XCNOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39115'MERGINGTAPERROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5W4-2W4-2LEFT LANECLOSEDAHEADW20-5LEFT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1200'ROADWORKAHEADW20-1ROADWORKAHEADW20-1W20-7aW20-7aW20-7aBE PREPAREDTO STOPW20-7b200'200' 200' 200'200' 200' 200' 200' 200' 200' 200'200' 200'200' 200'200' MH 4-1 WORK AREA11' X 135' WORK AREA11' X 125' Comments: THIS IS TO ACCESS MH 4-1 LOCATED IN THE NE QUADRANT OF WILLIAMSAVE S AND S 4TH ST.THIS IS A LEFT LANE CLOSURE OF SOUTHBOUND WILLIAMS AVE NORTHOF HOUSER WAY S AND SHOULDER WORK OF EASTBOUND S 4TH ST.CROSSWALK CLOSED AT WORK AREA.FLAGGERS WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA. VICINITY MAP WILLIAMS AVE S @ S 4TH ST SPEEDLIMIT25 N WILLIAMS AVE S @ S 4TH ST MH 4-1 ACCESSSB LEFT LANE CLOSURE EB SHOULDER WORK CROSSWALK CLOSURE www.invarion.com MFP19005275 X X ONE WAY ONE WAY ONE WAYONE WAYTWO WAY ONE WAY HOUSER WAY S WILLIAMS AVE SS 4TH ST S 3RD ST 25 MPH 25 MPH 25 MPH 25 MPH 25 MPH25 MPHPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGPARKINGTRAFFIC CONTROL PLAN JOB # N.526460.C.45 PERMIT # Designed for: CENTURYLINK Project # N526460.C.45 Darlene DurrTraffic Control SupervisorTCS # 011915 Approved 6/12/19 Phone 253-737-5198darlene.durr@hotmail.com _______________________ Date:6/12/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.526460.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr Legend WORK AREA CONES SPOTTER WORK TRUCK Plan Scale 1 : 2468 (1'' = 206')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX NOFROMTO TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 HH 2-6 WORK AREA10' X 100'SIDEWALK CLOSEDCROSS HERER9-11a(L)SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R)ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5200' 200'200' 200' 200' 200' Comments: THIS IS TO ACCESS HH 2-6 LOCATED IN THE WEST SIDE OF WILLIAMS AVE S SOUTH OF S 3RD ST.THIS IS SHOULDER WORK OF SOUTHBOUND WILLIAMS AVE S SOUTH OF S 3RD ST.SIDEWALK CLOSED AT WORK AREA.SPOTTER WILL ASSIST AT WORK AREA.PARKING RESTRICTED AT WORK AREA. WILLIAMS AVE S @ S 3RD ST HH 2-6 ACCESS SB WEST SHOULDER WORK WEST SIDEWALK CLOSURE SPEEDLIMIT 25 N 35'SHOULDERTAPERwww.invarion.com MFP19005275 COEFM s i te : STTMWAFLTEUnknown TEAAA A AAAAAAAAAAA AAAA AA AAAAAAAAA AAAAAA AAAAAA AA AA HH HHMHHHMH HHHH HHHH HH HHHHHHHH MHHHHH MHHH HHHHHH HHHH MHHHHHHHHHHH HHHHS 4 STS 3 STWELLS AVE WILLIAMS AVE S S 4 STS 3 STS 3 STS 4 STSMITHERS AVE S S 3 STBURNETT AVES HOUSER WAYS 3 STHOUSER WAYHOUSER WAY WELLS AVE S SMITHERS AVE S WILLIAMS AVE SMITHERS AVE S BURNETT AVE SLOGAN AVE S HHHH P-3( N.526460.C.91 - PLCF )BM60(2)PD qty 125.00UD-BM60(2)Pqty 125.00N.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS1524/25/196/17/19PATH CHANGE, ADD BORE 300 BURNETT AVE STHIS JOB WILL PROVIDE FIBER FACILITIES TOCUSTOMER BANK OF AMERICA AT 300 BURNETT AVE SLOCATED WITHIN THE RENTON WIRE CENTER.LCON: CARI AMSBAUGHLCON#: 206-358-2650AT POF MH 204 SPLICE COUNT LRE26, 111-112 TO NEW24-F. PLACE NEW 24-F THROUGH EXISTING CONDUIT TOHH 2-6. AT HH 2-6 PLACE SPLICE CASE & SPLICE COUNTTO NEW 24-F. BORE NEW 24-F TO CUSTOMER BUILDINGAND PLACE NEW EQUIPMENT.ARMORID:0321-1932057BANK OF AMERICA300 BURNETT AVE SRENTON,WA 98057LRE26,111-112FalseFalseNOTrueFalse2015-140 NSC139TO COCUST LOCATION300 BURNETT AVE SMFP19005275 UnknownTEAAAAAAA AAAAAAAAAAA AA HHMHMH HHHHHH MHMHHH HHHHHH MHHHHH S 4 STS 3 STWELLS AVE S 4 STS 3 STS 3 STS 4 STS 3 STBURNETT AVE S 3 STHOUSER WAYHOUSER WAY WILLIAMS AVE LOGAN AVE S HHHH P-3( N.526460.C.91 - PLCF )BM60(2)PD qty 125.00UD-BM60(2)Pqty 125.00N.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS2524/25/19TO COPOF:MH204SEE SHT 3·AT POF MH 204 SPLICE COUNTLRE26, 111-112 TO NEW 24-F·PLACE NEW 24-F THROUGHEXISTING CONDUIT TO HH2-6HH6-4MH3-1HH2-6SEE SHT 4BANK OF AMERICA300 BURNETT AVE SRENTON,WA 98057SEE SHT 5·CONTINUE TO PLACE NEW 24FTHRU HH6-4 IN EXISTINGCONDUIT·LEAVE 100' LOOP·CONTINUE TO PLACE NEW 24FTHRU MH3-1 IN EXITINGCONDUIT·AT HH2-6 PLACE SPLICE CASE·PLACE NEW 24F·SPLICE COUNT LRE26,111-112·LEAVE 100' LOOPMH7MH4-1·CONTINUE TO PLACE NEW 24FTHRU MH7 IN EXITING CONDUIT·CONTINUE TO PLACE NEW 24FTHRU MH4-1 IN EXITINGCONDUITINTERCEPTEX.UGBORE PIT #1BORE PIT #1BORE 125'AND PLACE NEW 2"CONDUIT·P-3·INTERCEPT EXISTING UGCONDUIT·BORE FROM BORE PIT #1 TOBORE PIT #2·PLACE NEW 2" CONDUIT·TRANSFER UP BUILDING 12'·PENETRATE WALL ABOVEHARD CEILING TO MPOP·PULL NEW 24F TO MPOPMFP19005275 P-1( N.526460.C.08 - PLUF )BM-OCCUPIED qty 1076.00UO24 qty 1276.00HO1(25-48) qty 2.00WUMS qty 1.00WHAP-R qty 1.00SCSCTEZ5 SE68880' 2008PC-5X12LT-216PLUFLRE26,1-144 (Fibers: 1-144)TKURE1,1-72 (Fibers: 145-216)<Unknown,0>A3DHD671'PC-5B12LT-024PLUFLRE26,101-102 (Fibers: 1-2)A,3-24 (Fibers: 3-24)<N.381311,1> SE96 A3DHDSE68 SE96690' 2018PC-5X12LT-048PLUFLRE26,1-48 (Fibers: 1-48)<Unknown,0>FY605966' 1992PC-3412LT-096PLUFLG9,1-96 (Fibers: 1-96)<Unknown,0>TEZ53280' 2008PC-5X12LT-072PLUFTKURE1,1-72 (Fibers: 1-72)<Unknown,0>FH59924' 1992PC-3412LT-096PLUFLG9,1-96 (Fibers: 1-96)<Unknown,0>A3G07966' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> ------------A3DJ2(PLCF)(2018)1-1/4-T9-OR-WT----------------------------------------MH-204[FY60][A3G02][FH59]FEED-TO COFEILD-TO CUSTOMERN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS3524/25/19TO COTO SHT 4HH2-6·AT POF MH 204 SPLICE COUNTLRE26, 111-112 FROM EXISTING216F [SE68]TO NEW 24-F[A3G02]·PLACE NEW 24-F THROUGHEXISTING CONDUIT TO HH2-6·COUNT WILL FALL TO HH2-6MFP19005275 SC[A3G07][A3G02]-------A3G02310' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> A3G07966' 2019AF-5B39LT-024PLUFLRE26,111-112 (Fibers: 1-2)[DEAD]DD,3-24 (Fibers: 3-24)<N.526460,1> P-3( N.526460.C.08 - PLUF )WHAP-R qty 1.00BM-OCCUPIED qty 210.00UO24 qty 310.00HO1(25-48) qty 2.00HUSO(11.5X31)DH qty 1.00HH2-6FEED-TO COFEILD-TO CUSTOMERN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS4524/25/19TO COTO SHT 3MH204TO SHT 5MPOP·AT HH2-6 PLACE SPLICE CASE·PLACE NEW 24F·SPLICE COUNT LRE26,111-112FROM NEW 24F [A3G02] TONEW 24F [A3G07]·ROD AND PROOF EXISTING 2"UG FROM HH2-6 TO CUSTOMERMPOP·LEAVE 100' LOOPMFP19005275 P-2( N.526460.C.09 - INBF )BM-FDP qty 1.00BM-OCCUPIED qty 25.00UO24 qty 50.00HO1(25-48) qty 24.000125'A3G05300 BURNETT AVE SADCP-FL1-H6777NNQ-2222D(INBF)(2019)[in]LRE26,111-112 (Ports: 1-2)[DEAD]DD,3-24 (Ports: 3-24)<N.526460,1> AA WALL MOUNT BACKBOARDWLMT.01Bay(WALL MOUNT BACKBOARD), Number ... [Conn.Point]A3G0350' 2019AF-5B39LT-024INBFLRE26,111-112 (Fibers: 1-2)[DEAD]A,3-24 (Fibers: 3-24)24 PORT FDPBay Interna ls WALL MOUT BACKBOARD 01Floor24 PORT FDP24FN.526460A.2619430RNTNWA01-CDFS-300 BURNETT AVE SRNTNWA016/27/19RENTONRENTONSTEPHEN STUART360 676 7955STEFANIE GONSALVESMOUNTAIN LTDPAUL BUTLER206 733 8590ED STIMMEL206 345 300642522654071823N5ENTS5524/25/19CUST BUILDING DETAIL:300 BURNETT AVE SCUSTOMER: BANK OF AMERICALCON NAME: CARI AMSBAUGHLCON PHONE: 206-358-2650ADDRESS: 300 BURNETT AVE SRENTON,WA 98057CLLI: RNTNWA01FEED FIBERS: LE26,111-112CUSTOMER TERMINAL: 300 BURNETT AVE SWFMT#: A.2619430BUILDING CLLI: RNTNWA79EQUIPMENT CLLI: RNTNWA7900WCONTINUE TO PULL NEW 24-FIBER THRUEXISTING CUSTOMER CONDUIT TO MPOPLOCATED ON 1ST FLOOR, ON EAST WALLWALL IN SERVER RM. AT MPOP. USECOUNT, LRE26,111-112 TO NEW FDPLEAVE 25' FIBER LOOP.PLACE NEW 24-PORT FDP IN MPOP.TERMINATE FIBERS LRE26,111-112 INTOFDP PORTS 1-2. TEST FIBERS END TO END.NO CLEAR PATH NEEDED. WHOLESALE.CUSTOMER TO PROVIDE 10FOOT PATCHCABLE TO NEW CIENA 3916 BEHINDEXISTING SERVER RACKMFP19005275