HomeMy WebLinkAboutMFP19003270.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP19003270 IVR Number: 19003270 Permit Informaon Permit Name:Puget Sound Energy - Electric Address/Locaon :06/13/2019Application Date:3123059069Parcel Number:4512 TALBOT RD S Permit Type:07/03/2019Issue Date:Franchise Permit Work Class:07/02/2020Expiration Date:Minor Utility Job Number:105089968Franchise Type:Electric Description:Remove two utility poles. Underground utilities with new HH, vault and trench on private property. APPROVED WITH CONDITIONS: See attached conditions for Trees Contacts Name Address PhoneTypeBilling Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: տ New Construction տ Repair/Relocate տ Underground տ Overhead տ Sidewalk տ Street տ Open Trench տ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 105089968 CORRIE RYDBERG (253) 234-6410 CORRIE.RYDBERG@PSE.COM 4500 TALBOT DR SE REMOVING P02(316318-165915) & P03(316320-165927) AND ALL EQUIPEMENT ATTACHED. INSTALLING RISER ON P01(316314-165904). SET A 50KVA XFMR AT V01(316321-165896). INSTALLING UG PRIMARY CABLE FROM P01(316314-165904) TO V01(316321-165896). REMOVE OH WIRE FROM P01-P02-P03. INSTALLING A NEW HANDHOLE AT HH2. PLEASE SEE ATTACHED ✔✔✔✔✔ ✔15'X2'X2' Potelco, Inc. (253) 234-6410 POTELI#227PL BL005109 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.06.13 13:56:37 -07'00'6/13/19 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: •Comply with all traffic regulations of the City of Renton and the State of Washington. •Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. •Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form 105089968 Potelco, Inc MARC BAYLEY (253) 259-4494 6905 S 228th St, Kent, WA 98032 MARCUS.BAYLEY@PSE.COM 4500 TALBOT DR SE TBD TBD CORRIE RYDBERG 6/13/19 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.06.13 13:57:03 -07'00' SKETCH I -- NORTH -- I NOTES: •Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. •The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. •Approved Temporary Traffic Control Plan must be at the work site during work hours. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. •Total road closure lasting more than 24 hours is subject to the approval by the City Council. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. •The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). TALBOT RD SS 45TH PL S 46TH PL(PRVT) S 47TH ST(PRVT) 111111 2121P02 P03 STOP FLAGGER 1811 FROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING P01X'X'PLACE W20-1 SIGNS ON ALL ADJACENT STREETS WITHIN FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1700 #4500 SHOULDER WORK W21-5UTILITY WORKAHEAD W21-7350'350'UTILITYWORKAHEADW21-7350'12121212V01HH2 HH1 ALLOW 11' MINFLAGGER/SPOTTER SHALL ESCORT PEDESTRIANS AROUND WORK AREA CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 N PSE PUGETSOUNDENERGY JOB#105089968 4500 Talbot Rd S, Renton, WA 98055 6/11/2019 stacie.fortiner@pse.com 425-424-6514 SHEET 1 of 1 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 008997 Card Exp. 08/13/2019 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 4500TALBOT RD SPARCEL # 3123059067 316320-165895 37.5 kVA 120/240V (B) UNK 316305-165895 T2/24 316314-165904 SW#T82314 (25T) 316320-165927 316318-165915 25 kVA 120/240V (C) 316321-165896 50 kVA 120/240V (C) SITE PLAN ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)JOB SITE ASPLUNDH CONSTRUCTION CORP. - QA/QC T. Myer 00 1"2" 00 50'100' CUSTOMER DEVELOPMENT NOTES: A PRE CONSTRUCTION MEETING IS REQUIRED WITH YOUR PROJECT MANAGER PRIOR TO STARTING ANY SITE WORK. CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS & LOCAL MUNICIPALITY. **DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL** CUSTOMER IS RESPONSIBLE FOR THE FOLLOWING: CROSSING/BORING. -OPEN TRENCH OR BORING FOR CROSSINGS ARE ALLOWED PER LOCAL MUNICIPALITY PERMIT REQUIREMENTS. -CROSSINGS IN RIGHT OF WAY MUST BE SCHEDULED WITH PROJECT MANAGER PRIOR TO CONSTRUCTION. -PROJECT MANAGER OR DESIGNATED REPRESENTATIVE MUST BE ON SITE DURING CONSTRUCTION WORK IN RIGHT OF WAY. -EXCAVATION CONTRACTOR MUST BE LICENSED AND BONDED TO PERFORM WORK IN RIGHT OF WAY. VAULTS & WORK PITS. -REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK AT P01 -REQUIRED TO PROVIDE 6' X 6' WORK PIT 2/3 CUBIC YARDS OF 6” CRUSHED ROCK AT V01 -REQUIRED TO PROVIDE 6' X 6' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT HH2 -REQUIRED TO PROVIDE 4’ X 4’ WORK PIT AT HH1 TRENCHING & CONDUIT. -REQUIRED TO PROVIDE AND INSTALL A 3/8" NON-POLY PULL ROPE IN ALL OF THE CONDUITS. JOB SITE READINESS. -JOB SITE NEEDS TO BE 100% READY FOR INSPECTION 5 BUSINESS DAYS PRIOR TO CONSTRUCTION DATE. -ALL WORK IN RIGHT OF WAY MUST BE COORDINATED WITH PROJECT MANAGER AND LOCAL MUNICIPALITY. -ALL TRENCH, AND LOCAL ELECTRICAL MUNICIPALITIES AKA "L&I, CITY", INSPECTIONS MUST BE COMPLETED 5 BUSINESS DAYS PRIOR TO SCHEDULED CONSTRUCTION DATE. -REQUIRED TO OPERATE AND PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS, VAULTS & TRENCH AT ALL TIMES. -REQUIRED TO HAVE EXCAVATION EQUIPMENT AND BE ON SITE THE DAY OF CONSTRUCTION TO COMPLETE BACKFILLING. - IF A SECOND INSPECTION IS REQUIRED, ADDITIONAL FEE'S WILL BE APPLIED. -PLEASE REVIEW THE CITY OR KING COUNTY TRENCHING REQUIREMENTS UNDER THE PERMIT. -IF A PRE-CON IS REQUIRED BY THE CITY, COUNTY OR W.S. DOT A PSE PROJECT MANAGER WILL SET-UP AND SCHEDULE A MEETING WITH THE MUNICIPALITY BEFORE ANY EXCAVATION OR INSTALLATION BEGINS . POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them, or as required by your local municipality. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point on private property. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: V01 316321-165896 50 kVA 6247100 CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE NOP-26 190.00 181.00 229.00 0.00 0.00 0.00 190.00 181.00 229.00 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP M. BAYLEY 253-234-6432 09/19/18 K. GOUESSE 253-395-6922 09/19/18 E. SCHOTT 714-893-2405 09/19/18 RW#RENTON WEATHERLY INN RENTON 3PHS UG COMM LINE EXT (PHASE 1) 4500 TALBOT DR. SE, RENTON, WA 98055 N/A N/A N/A 105089968 AS NOTED 1 OF 3 KING N/A N/A CSPSKEIN NE 31-23N-05E N/A N/A 2305E121 230E124 2305E121 NOP-26 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 105089968SCALE: 6" = 1 MILE OVERHEAD CIRCUIT MAP 230E124 NOP 26 SITE SPECIFIC NOTES AT P01: 316314-165904 -EXISTING POLE TO REMAIN ,167$//  67,5583%2/7(' +27&/$03 7$3&‘ 0,'2254100 & 2153100) -INSTALL (1) 12kV 200AMP OH/UG TERMINATION PER STD 6043.1000 (TSU1C1) -INSTALL (1) LB C/O ON NEW FG ARM, FUSE @ 25T (MID: 3412400) -INSTALL SWITCH #T82314 -INSTALL (1) 2" PRIMARY RISER ON NEW STANDOFF BRACKETS PER STD 6042.1000 5,6&66 “ BBB $&78$/ -INSTALL CABLE TAG&Ҁ(,' AT P02: 316318-165915 -REMOVE EXISTING 1986 40' POLE AND 25KVA TRF -REMOVE EXISTING 3'' SECONDARY RISER & 4/0 UG TPLX FEED TO HH1 AT P03: 316320-165927 -REMOVE EXISTING 1966 40' POLE AND 10KVA TRF -REMOVE EXISTING DOWN GUY/ ANCHOR AT V01: 316321-165896 -INSTALL (1) 36" X 42" X 38" MINI-PAD UNISTRUT HH W/ GROUNDS PER STD 6045.1010 (MINU1SR) -INSTALL (1) 50KVA PADMOUNT TRF (MID: 6247100) -INSTALL (1) 12kV ELBOW KIT PER STD 6041.1000 (ELB10J) -INSTALL (1) DUST CAP (MID: 7630600) -INSTALL (3) 6- POS #6-350 KCMIL SECONDARY CONNECTION BLOCKS (MID: 4842002) -INSTALL GRID #316321-165896 ,167$//&$%/(7$*&Ҁ(,' AT HH1: EXISTING STRUCTURE TO REMAIN -CUSTOMER TO LOCATE AT HH2: NEW -INSTALL (1) 30"x30" CONCRETE HAND HOLE WITH STEEL DOOR PER STD 6050.2020 (HH14350AS). -INSTALL (3) 4-POS #10-350 SECONDARY CONNECTION BARS, MID (7651005) ___ ___ ROW 90' ___ ___ UNDERGROUND CIRCUIT MAP SCALE: 6" = 1 MILE JOB SITE PARCEL # 3123059094 SPAN SPECIFIC NOTES P01 TO P02 TO P03: -REMOVING (;72+$&65“ BBB $&78$/ P01 TO V01: ,167$//6&+ /&217,1828639&&21'8,7“ BBB $&78$/ ,167$//581‘8*JKT CABLE“¶BBB $&78$/ V01 TO HH1: ,167$//6&+ /&217,1828639&&21'8,7“ BBB $&78$/ -INSTALL 1-RUN 350 UG TPX“ BBB ACTUAL V01 TO HH2: ,167$//6&+ /&217,1828639&&21'8,7“ BBB $&78$/ -INSTALL 1-RUN 350 UG TPX“ BBB ACTUAL ___ PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:MARK BAYLEY 253-259-4494 MARK.BAYLEY@PSE.COM GAS PHONE CABLE TV PROJECT PHASE PWR NOTIF#ORDER# 504767395 594123258 583060285 108108473 101114621 105089968 Dist UG Maintenance Dis OH Operations Dist Retirement Dist Improvement Superior Owner / Developer Contact Info officeATTN: WEATHERLY INN - RENTON LLC 606 COLUMBIA ST. NW #101 OLYMPIA, WA 98501 DICK VELDSMA 541-279-1545 N Vicinity Map N/A JOB SITE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P02 316318-165915 25kVA Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P03 316320-165927 10kVA 316314-165904 UNK SW#_____ (25T) 316321-165896 50 kVA 120/240V (C) CUSTOMER SUPPLIED 6'X6' WORK PIT & 6” BEDDING OF COMPACTED CRUSHED ROCK PSE PROVIDED & INSTALLED 1-3" SCH'L 80 PVC GREY CONDUIT ±50' IN CUSTOMER PROVIDED TRENCH PSE INST. 1-RUN 350 UG TPX ±70' CUSTOMER SUPPLIED 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK PSE PROVIDED & INSTALLED 1-2" SCH'L 80 PVC GREY CONDUIT ±100' IN CUSTOMER PROVIDED TRENCH PSE INST. 1-RUN 1/0 UG JKT CABLE ± 140' (CØEID992) PSE PROVIDED & INSTALLED 1-3" SCH'L 80 PVC GREY CONDUIT ±70' IN CUSTOMER PROVIDED TRENCH PSE INST. 1-RUN 350 UG PLX ±90' CUSTOMER SUPPLIED 4' X 4' WORK PIT & 3/4 YARD SAND CUSTOMER SUPPLIED 6' X6' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK ASPLUNDH CONSTRUCTION CORP. - QA/QC T. Myer UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP M. BAYLEY 253-234-6432 09/19/18 K. GOUESSE 253-395-6922 09/19/18 E. SCHOTT 714-893-2405 09/19/18 RW#RENTON WEATHERLY INN RENTON 3PHS UG COMM LINE EXT (PHASE 1) 4500 TALBOT DR. SE, RENTON, WA 98055 N/A N/A N/A 105089968 AS NOTED 2 OF 3 KING N/A N/A CSPSKEIN NE 31-23N-05E N/A N/A 2305E121 230E124 2305E121 NOP-26 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 105089968THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) CABLE & CONDUIT DIAGRAM NOT TO SCALE RETIREMENT POLE TABLE SITE # POLE DATA POLE TRANSFERS REMARKS GRID #HEIGHT CLASS YEAR XFMR CO. ID#TOPPED RMVD TEL TV FIBER ST. LIGHT (ADDITIONAL INFORMATION) P02 316318-165915 --- P03 316320-165927 --- VAULT & EQUIPMENT TABLE SITE #GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED V01 316321- 165896 36"x42"x38" PM HH Matid: 7663001 50KVA MP TRF 120/240 Matid: 6247100 WIRE REMOVAL TABLE LOCATION Wire Size & Type PRI/ NEUT Quantity Length Per Conductor REMARKS FROM TO P01 P02 #2 ACSR 2 70'- P02 P03 #2 ACSR 2 30' SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed Lot Corner CONDUIT VOLTAGE DROP VOLTAGE FLICKER ASBUILT INFORMATION SIZE LENGTH Design (ft) SIZE LENGTH Design (ft) BENDS Foreman - Complete FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable) V01 HH2 SEC 350 UG TPX 70 0 3 50 3 0 0 0 0 V01 HH1 SEC 350 UG TPX 90 0 3 70 2 0 0 0 0 PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED 90°45°22°11°A B C MANUFACTURE R COMPOUND YEAR NOTES CONDUIT CABLE P01 V01 2 1 100 2 0 0 0 74 75 1/0AL JKT 140'cɸEID992 - 2" PVC (FT) & BENDS =2 0 0 0 1/0 AL JKT TOTAL (FT) =140' ASPLUNDH CONSTRUCTION CORP. - QA/QC T. Myer UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP M. BAYLEY 253-234-6432 09/19/18 K. GOUESSE 253-395-6922 09/19/18 E. SCHOTT 714-893-2405 09/19/18 RW#RENTON WEATHERLY INN RENTON 3PHS UG COMM LINE EXT (PHASE 1) 4500 TALBOT DR. SE, RENTON, WA 98055 N/A N/A N/A 105089968 AS NOTED 3 OF 3 KING N/A N/A CSPSKEIN NE 31-23N-05E N/A N/A 2305E121 230E124 2305E121 NOP-26 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 105089968Communications Primary Power Cables or Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min 12" Min Separation 36" Min Cover 48" Max Backfill (No rocks over 10" diameter) Separation 12" Min Gas 4" Sand Bedding 32" Typical (Power, Gas, and Communications) JOINT TRENCH DETAIL Primary-Mainline Gas & Communications (NTS) Separation 12" Min 6" or 12" Min Sand Shading after Compaction - A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. TV & TEL Electric Service Cable in Conduit 3" Schedule 40 Grey PVC Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover Backfill for Conduit Free of rocks larger than 8" in diameter Separation 12" Min in Conduit Schedule 40 White PVC Gas Service Line 32" Typical (Power, Gas, Phone & Cable) Separation 12" Min 12" Min Separation 36" MINIMUM COVER IN RIGHT OF WAY JOINT TRENCH DETAIL Joint Service Line in Conduit (NTS) To Excavated Dirt Pile Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. UTILITY POLE EROSION CONTROL DETAIL TOP VIEW DRY DRAINAGE DITCH or DRY VEGETATED SITE SLOPE Place gravel bags for Sediment Trap Place straw mulch on disturbed areaExcavated or Augered Hole Pole SLOPE Not to scale Drainage ditches or Dry vegetated sites FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL SILT FENCE DETAIL Standoff Bracket 15" Min Length Conduit Clamp ConduitField FaceQuadrantClimbing Space Road FaceQuadrantClimbing Space5" MinCLLC Direction of Vehicular TrafficUNDERGROUND CABLE CONDUITS TO THIS QUADRANT TOP VIEW CONDUIT RISER PLACEMENT DETAIL: AT P01 SCALE: NONE COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT: AT V01 NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 10' 10' APPROVED TRANSFORMER AREA 10' TRANSFORMER CLEARANCES FROM COMBUSTIBLE SURFACESCOMBUSTIBLE BUILDING WALLS AND ROOFTHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) SINGLE PHASE SECONDARY CONCRETE HANDHOLE: AT HH2 Not to scale 6050.2020-1 TOP VIEW SIDE VIEW 2'-4" EXCAVATION: 5-1/3 CUBIC YARDS 6'-0" 2" 2'-6" Install PVC bell endsand grout into wall 2'-6" Handhole 820 lbs Conduits and conductors shall enter fromends of handhole through knockouts provided Typical customer run service conductors in duct Steel Door Seal conduit with foam Customer-installed grounding wires ( the "4th" wire on the single-phase systems and the "5th" wire on the three-phase systems) shall not be connected to PSE's ground or neutral bus. They shall be removed by customer or cut off at the vault wall. 6" Crushed rock 6'-0" VAULT & EXCAVATION DETAIL: AT V01 Not to scale 6045.1000 TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONT LAYTON TREE CONSULTING, LLC It’s all about trees…… PO BOX 572, SNOHOMISH, WA 98291-0572 * 425-220-5711 * bob@laytontreeconsulting.com TREES & CONSTRUCTION MEMO RJ Development To: Frank Durocher From: Bob Layton CC: Date: October 4, 2019 Re: 4500 Talbot RD S – ROW Utility Work near Trees Mr. Durocher, On September 27th per your request, I visited your project site at 4500 Talbot Road S to evaluate the potential impacts to Trees #1 and #2 associated with placing the electric utility underground adjacent to the new access road. A new transformer is proposed to be placed within the critical root zone of Tree #1. It is my understanding that the transformer location cannot be moved per your agreement with the neighboring property owner. The transformer will also require a certain amount of clearance around it in order for it to be serviced in the future by the utility company. The excavation required for the transformer installation is significant. See the attached diagram. It will require soil excavation within 2-feet of the root crown of Tree #1. This major encroachment is likely to compromise long-term health and stability. Removal is warranted to prevent a future hazard and provide the necessary space to appropriately install and service the utility in the future. Tree #2 will also be impacted by the utility work but not to the same degree as Tree #1. This tree can be retained if work is carried out diligently. The amount of root loss associated with trenching the utility is not expected to jeopardize health or structural stability. This tree has a large cluster of surface roots that extend east from the trunk. See pictures below. This root cluster will not be impacted by the utility trench. Pine trees have good relative tolerance to root loss and disturbance related to development activities. The tree is currently of good vigor and October 4, 2019 4500 Talbot RD S - Trees Page 2 LAYTON TREE CONSULTING, LLC in good structural condition. I would expect it to remain viable long-term if the measures outlined below are adhered to. Tree Protection Measures • Mark on the ground with paint the extent of required excavation. • Cover the ground on the north side of the trench (critical root zone) with plywood or hog fuel for equipment to run on. Use a tracked mini-excavator. • Gradually excavate trench by removing only a few inches of soil at time. Any root encountered that is greater than 2-inches in diameter will be hand-excavated at cut cleanly at the north edge of the trench. • After trench is excavated to the required depth, hand excavate and prune clean to sound tissue any damaged root ends over one-inch in diameter. Sound tissue is where the root is undamaged and the bark is completely intact with the root. • When work is complete, position a protection barrier at the dripline or to the largest extent possible keeping equipment and materials outside of the protection zone at all times. • Provide supplemental irrigation to the tree every 7 to 10 days during the dry season of June through September. Please let me know if you have any questions or need further assistance on this project. Sincerely, Bob Layton Registered Consulting Arborist #670 ISA Certified Arborist #PN-2714A ISA Tree Risk Assessment Qualified October 4, 2019 4500 Talbot RD S - Trees Page 3 LAYTON TREE CONSULTING, LLC Tree #1 Tree #1 (left), Tree #2 in background on left October 4, 2019 4500 Talbot RD S - Trees Page 4 LAYTON TREE CONSULTING, LLC Lower trunk of Tree #2, note large root cluster east of tree (bottom of photo) Tree #2 on right, Tree #1 in background DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP19003270 Planning 1 When work is complete, the applicant shall position a protection barrier at the dripline or to the largest extent possible keeping equipment and materials outside of the protection zone at all times. 2 The applicant shall gradually excavate the trench by removing only a few inches of soil at time. Any root encountered that is greater than 2-inches in diameter shall be hand-excavated at cut cleanly at the north edge of the trench. 3 The applicant shall cover the ground on the north side of the trench (critical root zone) with plywood or hog fuel for equipment to run on. A tracked mini-excavator shall be used. 4 The applicant shall mark on the ground with paint the extent of required excavation prior to grading/digging activities. 5 After the trench is excavated to the required depth, the applicant shall hand excavate and prune clean to sound tissue any damaged root ends over one-inch in diameter. (Sound tissue is where the root is undamaged and the bark is completely intact with the root.) Page 1 of 1