Loading...
HomeMy WebLinkAboutMFP19005424DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP19005424 IVR Number: 19005424 Permit Informaon Permit Name:Century Link Permits Address/Locaon :10/07/2019Application Date:2423049037Parcel Number:1400 MONSTER RD SW Permit Type:10/15/2019Issue Date:Franchise Permit Work Class:10/14/2020Expiration Date:Minor Utility Job Number:N481676Franchise Type:Telephone Description:Century Link to trench 15' to connect 2 MH's and pull approx. 880 LF of fiber through existing conduit. APPROVED WITH COMMENTS OR REDLINES. ***ONLY THE SCOPE WITHIN THE CITY OF RENTON IS APPROVED. A PORTION OF THE SCOPE SHOWN ON PLANS IS WITHIN THE CITY OF TUKWILA*** Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES NorthSky Communications # BL.036846 253-569-7067 Washington State # 601973 572 RESTORATION PER CITY OF RENTON STANDARDS MFP19005424 Nathan Janders 10/15/2019 10/9/2019Scott Warlick Page 1 of 2 Type of TCP: Work Hours Phase of Work: Trenching Traffic Control Plan Hours of TCP: 9AM-3PM 24 hr Contact: Kayvan Fassnacht CableCom 206.914.5047 Kayvan.Fassnacht @cablecomllc.net Job Number: N481676 Job Name: 6101 connection Address: S 180th St Andover Park W Description: Trench aproximatley 15' between 920 MHs to connect them together Notes: 1. X, l, and B distances are not to scale 2. Contractor shall always provide access to driveways 3. Standard Advance Warning Signs shall be used for plates or rough road during after-hours, including "motorcyclist" sign 4. Flaggers shall be used in accordance with WAC 468-95-302. UPO will be required if a traffic signal could be countermanded 5. If only one lane is open in a direction, that lane shall be a minimum of 11' wide, unless spotter/flaggers are used, in which case the lane can be a minimum of 10' 6. Sidewalks are either open or not open. A sidewalk is closed if a minimum 4' path cannot be maintained measured from property line, or 5.5' if created from face of curb Legend Traffic Cones Temp Sign Location Work Vehicle Lane Minimum Taper Length = L (feet) width Posted Speed (mph) (feet) 25 30 35 40 45 50 10 105 150 205 270 450 500 11 115 165 225 295 495 550 12 125 180 245 320 540 600 Sign Spacing = X Rural Roads 45/55 mph 500' Rural Roads & Urban Arterials 35/40 mph 350' Rural Roads & Urban Arterials 25/30 mph 200' Residential & Business Districts Urban Streets 25 mph or less 100' (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. Channelization device spacing (feet) mph taper tangent 50 40 80 35/45 30 60 25/30 20 40 N Buffer Data Longitudinal Buffer Space = B Speed (Mph) 25 30 35 40 45 50 55 60 65 70 Length (feet) 155 200 250 305 360 425 495 570 645 730 SPEEDLIMIT35 R2 - 35 25 Monster Rd SWLongacres Dr SW11'12' 8'1400work area5' 20'xROADWORK AHEAD W20 - 1 W20-130" - 48" ROADWORK AHEAD W20 - 1 W20-130" - 48" SHOULDERWORK W21-530" - 48"XX MFP19005424 Page 2 of 2 Type of TCP: Work Hours Phase of Work: Pulling fiber Traffic Control Plan Hours of TCP: 9AM-3PM 24 hr Contact: Kayvan Fassnacht CableCom 206.914.5047 Kayvan.Fassnacht @cablecomllc.net Job Number: N481676 Job Name: 6101 connection Address: S 180th St Andover Park W Description: Pull fiber through MH Notes: 1. X, l, and B distances are not to scale 2. Contractor shall always provide access to driveways 3. Standard Advance Warning Signs shall be used for plates or rough road during after-hours, including "motorcyclist" sign 4. Flaggers shall be used in accordance with WAC 468-95-302. UPO will be required if a traffic signal could be countermanded 5. If only one lane is open in a direction, that lane shall be a minimum of 11' wide, unless spotter/flaggers are used, in which case the lane can be a minimum of 10' 6. Sidewalks are either open or not open. A sidewalk is closed if a minimum 4' path cannot be maintained measured from property line, or 5.5' if created from face of curb Legend Traffic Cones Temp Sign Location Work Vehicle Lane Minimum Taper Length = L (feet) width Posted Speed (mph) (feet) 25 30 35 40 45 50 10 105 150 205 270 450 500 11 115 165 225 295 495 550 12 125 180 245 320 540 600 Sign Spacing = X Rural Roads 45/55 mph 500' Rural Roads & Urban Arterials 35/40 mph 350' Rural Roads & Urban Arterials 25/30 mph 200' Residential & Business Districts Urban Streets 25 mph or less 100' (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. Channelization device spacing (feet) mph taper tangent 50 40 80 35/45 30 60 25/30 20 40 NBuffer Data Longitudinal Buffer Space = B Speed (Mph) 25 30 35 40 45 50 55 60 65 70 Length (feet) 155 200 250 305 360 425 495 570 645 730 SPEEDLIMIT35 R2 - 35 25 1200 12001400 Monst e r R d S W Jack s o n P l S W workarea8' 8' ROADWORK AHEAD W20 - 1W20-130" - 48" SHOULDERWORK W21-530" - 48" L/3 X X MFP19005424 DRAWING NAME:LEVEL 3 ENGINEER:ENGINEERING FIRM:PROJECT NUMBER:LOCATION:Renton_6101 Connection.dwgNO.123KAYVAN FASSNACHTWAECO ENGINEEERINGN48167618000 72ND AVE. S., KENT, WA. 98032#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET # FOR SITE PHOTOGRAPHS.ADDRESS: 1400 MONSTER RD SW, RENTON, WA 98057PROJECT NAME: TUKWILA_6101 CONNECTIONSITE LOCATIONCONTACT INFOKayvan FassnachtCentury LinkOSP EngineerKayvan.Fassnacht@centurylink.com425-213-9378Spencer KariniemiWaeco EngineeringProject Engineerspencer@waecoconstruction.com360-722-2852SHEET INDEX1 - COVER SHEET/SITE LOCATION2 - LEGEND3 - DESIGN VIEW "A" CONSTRUCTION4 - DESIGN VIEW "B" CONSTRUCTION5 - SITE PHOTOSSCOPE OF WORK:AT EXISTING MH IN THE RIGHT OF WAYSOUTH OF THE 1400 MONSTER RD SW,TRENCH APPROXIMATELY 15' TO A 2NDEXISTING MH. SPLICE THE ONFIBER 144CTCABLE TO THE TW 144CT CABLE, ADDING A96CT CABLE TO PULL SOUTH TOWARDS6101 S 180TH ST, TUKWILA, WA 98188Know what's belowCall before you dig.RCONFIDENTIAL/PROPRIETARYSHEET: OF 15MFP19005424 DRAWING NAME:LEVEL 3 ENGINEER:ENGINEERING FIRM:PROJECT NUMBER:LOCATION:Renton_6101 Connection.dwgNO.123KAYVAN FASSNACHTWAECO ENGINEEERINGN48167618000 72ND AVE. S., KENT, WA. 98032IDLEVEL3HH-HANDHOLELEVEL3MH-MANHOLELEVEL3PB-PULLBOXLEVEL3VAULT-VAULTLEVEL3MANUFACTURERNAME#F#F#F111111#LEGENDKnow what's belowCall before you dig.RCONFIDENTIAL/PROPRIETARYSHEET: OF 25MFP19005424 DRAWING NAME:LEVEL 3 ENGINEER:ENGINEERING FIRM:PROJECT NUMBER:LOCATION:PHASE2_6101 Connection.dwgNO.123KAYVAN FASSNACHTWAECO ENGINEEERINGN48167617000 W VALLEY HWYTUKWILA, WA 98188SW GRADY WAYMONSTER ROAD SW#Know what's belowCall before you dig.RCONFIDENTIAL/PROPRIETARYSHEET: OF 313#CONSTRUCTION NOTES1MATCH TO SHEET42123344Page Rate CardUnit Code & DescriptionUnitsEstimatedQuantityActualQuantityFIBER PL IN CONDUITROD & PROOF EXISTING CONDUIT UGCTL WORK AREA PROTECTIONDEWATERING BASICFTFTEAEAEA409433122COMPACTION TESTSQ FT48CORE DRILL OSP CONCRETE 3inDIG & EXPOSE EXIST FACILITYEA2EA2LOCATE WIRE WITH BORE-PLOW-TRENCHFT24TRENCH 36in CVR <= 2.5inVAULT - TEST PURGE & VENTILATEFT24MFP19005424 DRAWING NAME:LEVEL 3 ENGINEER:ENGINEERING FIRM:PROJECT NUMBER:LOCATION:PHASE2_6101 Connection.dwgNO.123KAYVAN FASSNACHTWAECO ENGINEEERINGN48167617000 W VALLEY HWYTUKWILA, WA 98188#Know what's belowCall before you dig.RCONFIDENTIAL/PROPRIETARYSHEET: OF 416#CONSTRUCTION NOTES1MATCH TO SHEET 512 MATCH TO SHEET3Page Rate CardUnit Code & DescriptionUnitsEstimatedQuantityActualQuantity2FIBER PL IN CONDUITROD & PROOF EXISTING CONDUIT UGCTL WORK AREA PROTECTIONDEWATERING BASICFTFTEAEAEA471471111VAULT - TEST PURGE & VENTILATEMFP19005424work is not in city of rentonROW. contact city of tukwilafor approval of work. DRAWING NAME:LEVEL 3 ENGINEER:ENGINEERING FIRM:PROJECT NUMBER:LOCATION:Renton_6101 Connection.dwgNO.123KAYVAN FASSNACHTWAECO ENGINEEERINGN48167618000 72ND AVE. S., KENT, WA. 98032Know what's belowCall before you dig.RCONFIDENTIAL/PROPRIETARYSHEET: OF 55SITE PHOTOGRAPHSTrench pathPlace new 2" conduitwith tie cableExisting conduit.Pull new cablethrough to MH byrailroad tracksExisting conduit.Pull new cablethrough to MH byrailroad tracksExisting conduit.Pull new cablethrough to MH inrailroad propertyMFP19005424