HomeMy WebLinkAboutSUBMITTAL1
Jinny Park Architecture, PLLC
Project Narrative
Project name: Tango Properties LLC Restaurant Remodel
Project Address: 247 Park Ave N., Renton WA 98057
Date: May 29, 2019
Site:
Tango Properties LLC owns three (3) parcels: 722400-0340, 722400-0335 and 722400-0330.
The two south parcels (0335 and 0330) are currently used for parking spaces. We would like to
continue using the two south parcels as parking lots serving for the restaurant.
Site modification:
We are proposing to convert existing eight (8) parking stalls into outdoor seating areas. There
will be an entry walkway between the outdoor seating areas.
We’ll convert some of the existing parking stalls into ADA stalls.
We want to continue using the two south parcels (0335 and 0330) for restaurant parking.
Restaurant Remodel:
The existing structure will remain and some of the interior walls will be relocated.
The existing bathrooms will be demolished and new ADA compliant bathrooms will be installed.
We would like to relocate the existing entry to the new location as shown on site plan sheet
A001.
The existing windows on north wall will be replaced with two garage doors.
The existing kitchen will remain the same.
Interior will receive new finish floors.
Questions/Concerns:
We would like to use parcel 0330 with R-10 zone for restaurant parking. Parcels 0340 and 0335
are CN zones. Please let us know if this is doable.
Please contact me for any questions.
Jinny Lee Park, AIA, NCARB
Jinny Park Architecture, PLLC
6052 113th PL SE Bellevue, WA 98006
jinnyleepark@gmail.com
Jinnyparkarch.com
425.445.2993
7
3
8
11
EXISTING
PARKING
LINE OF EXISTING WALL BELOW
12'-6"36'-6"46'-6"39'-8"55'-4"PROPERTY LINE 6'-10"78'-3"25'-9"
6"11'-0"93'-0"3'-0"
6"
EXISTING MAIN ENTRY
EXISTING CONCRETE WALK
EXISTING LANDSCAPE
EXISTING DRIVEWAYEXISTING DRIVEWAY EXISTING CONCRETE
SIDE WALK
EXISTING CONCRETE WALKFIRE HYDRANT
APPROX. LOCATION OF
EXISTING WATER METER35'-0"40'-0"
18'-0"18'-0"
CATCH BASIN
ELEVATION 99.0'(E) 12% SLOPE
(E) 12% SLOPE(E) STORM SEWER
(E) D.S.
(E) D.S.
(E) D.S.
(E) D.S.
(E) D.S.
12'-0"
ALLEY
GARBAGE
/RECYCLE
REMOVE EXISTING FENCE
EXISTING
BUILDING
EXISTING
PARKING
EXISTING
PARKING
722400-0340
722400-0335
722400-0330
7
2
11
EXISTING PARKING
LINE OF EXISTING WALL BELOW
12'-6"36'-6"46'-6"39'-8"55'-4"PROPERTY LINE 6'-10"78'-3"25'-9"
6"11'-0"93'-0"3'-0"
6"
EXISTING CONCRETE WALK
EXISTING LANDSCAPE
EXISTING DRIVEWAYEXISTING DRIVEWAY EXISTING CONCRETE
SIDE WALK
EXISTING CONCRETE WALKFIRE HYDRANT
APPROX. LOCATION OF
EXISTING WATER METER35'-0"40'-0"
18'-0"18'-0"
(E) C.B.
(E) 12% SLOPE
(E) STORM SEWER
(E) D.S.
(E) D.S.
(E) D.S.
(E) D.S.
(E) D.S.
12'-0"
ALLEY
GARBAGE
/RECYCLE
11
OUTDOOR SEATING
AREA
OUTDOOR SEATING
AREA
NEW ENTRY
EXISTING
BUILDING
722400-0340
722400-0335
722400-0330
A001
COVER SHEET
&
SITE PLAN
DateTANGO PROPERTIES LLC 4.30.19 PERMIT
JPA Project # 035 247 PARK AVE N.RENTON, WA 98057REGISTERED
ARCHITECT
STATE OF WASHINGTON
12602
JINNY PARK ARCHITECTURE, PLLCJINNYPARKARCH.COM425.445.2993COPYRIGHT C 2018-2019
JINNY PARK ARCHITECTURE, PLLC
ALL RIGHTS RESERVED
JINNYLEEPARK@GMAIL.COMSCALE:
VICINITY MAP
N.T.S.
ALL WOOD PLATES: IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE-TREATED WITH AN APPROVED PRESERVATIVE. PROVIDE 2 LAYERS OF
ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING,
ETC., AND CONCRETE OR MASONRY.
DRAWINGS: INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO
REVIEW AND APPROVAL BY THE ARCHITECT.
CONTRACTOR: SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS,
TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK.
CONTRACTOR: SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURAL COMPONENTS
UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS.
CONTRACTOR: SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS
PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN
ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED IN FIELD.
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO
THE DRAWINGS, SPECIFICATION NOTES, AND THE INTERNATIONAL BUILDING CODE
(2015 EDITION).
ARCHITECTURAL NOTES:
(THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS)
7.
6.
4.
5.
3.
2.
1.
8.
TANGO PROPERTIES LLC
RESTAURANT REMODEL
247 PARK AVE N.
RENTON, WA 98057
SCOPE OF WORK: CONVERT EXISTING PARKING INTO OUTDOOR SEATING
AREAS AND INTERIOR REMODEL
LEGAL DESCRIPTION: RENTON FARM PLAT, PLAT BLOCK: 5, PLAT LOT: 12-13
PARCEL #: 722400-0340
PROJECT DIRECTORY:
OWNER/APPLICANT:
TANGO PROPERTIES LLC
9826 16TH AVE SW
SEATTLE, WA 98106
P. 206. 683.1126
1218TANGO@GMAIL.COM
ARCHITECT:
JINNY PARK, AIA
JINNY PARK ARCHITECTURE, PLLC
6052 113TH PL SE
BELLEVUE, WA 98006
P.425.445.2993
EMAIL: JINNYLEEPARK@GMAIL.COM
CONTRACTOR:
TBD
PROJECT DATA:
ZONE: CN (COMMERCIAL NEIGHBORHOOD)
LOT AREA: 10,213 SF (0.23 ACRES), (PER KING COUNTY RECORD)
YEAR BUILT: 1966 / SINGLE STORY
EXISTING USE: RESTAURANT
PROPOSED USE: RESTAURANT
EXISTING OCCUPANCY GROUP: A-2
PROPOSED OCCUPANCY GROUP: A-2
EXISTING ROOF AREA: 5,840 SF (NO CHANGE)
EXISTING BUILDING AREA: 5,002 SF (NO CHANGE, PER KING COUNTY RECORD)
CONSTRUCTION TYPE: III B (CMU & BRICKS)
SET BACKS: EXISTING, NO CHANGE
FRONT (NORTH) 39.7'
SIDE (EAST) 3.0'
SIDE (WEST) 0.5'
REAR (SOUTH) 0'
STURCTURE HEIGHT: 12.0' (EXISTING)
EXISTING PARKING: TOTAL 18 STALLS (EXISTING)
ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES AND ORDINANCES. ANY
CONFLICT WHERE THE METHOD OR STANDARDS OF INSTALLATION OF THE MATERIAL
SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE APPLICABLE CODE OR
ORDINANCES, THE CODE OR ORDINANCES SHALL GOVERN, IN THE EVENT THIS OCCURS. THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. SUBSECTIONS OF THE CODE
ARE LISTED HERE FOR GENERAL REFERENCE, BUT DO NOT RELEASE THE CONTRACTOR
FROM CONFORMING TO ALL APPLICABLE BUILDING CODES AND ORDINANCES.
APPLICABLE CODES:
,17(51$7,21$/%8,/',1*&2'(,%&(',7,21
INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2015 EDITION
NATIONAL ELECTRICAL CODE (NEC), 2017 EDITION
WASHINGTON STATE ENERGY CODE (WSEC), 2015 EDITION
APPLICABLE CODES
LIST OF DRAWINGS
A001 COVER SHEET AND SITE PLAN
ELECTRICAL WORK IS SEPARATE PERMIT THAT WILL BE OBTAINED BY GENERAL CONTRACTOR.
THE ARCHITECTURAL DRAWING SET SHOWS LIGHTING ONLY FOR THE PURPOSE OF WSEC
COMPLIANCE. ALL ELECTRICAL WORK WILL BE SUBMITTED FOR PERMIT SEPARATELY.
MECHANICAL SYSTEMS ARE TO REMAIN AS IS. ANY MECHANICAL WORK THAT MAY ARISE
RELATED OR APART FROM THIS WORK SCOPE SHALL BE RESPONSIBILITY OF THE
CONTRACTOR AND IS NOT PART OF THIS PERMIT SET.
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL
TRADES TO ASSURE COMPLIANCE WITH DRAWINGS.
9.
247 PARK AVE N
SCALE:
EXISTING SITE PLAN
1" = 20'-0"RESTAURANT REMODELSCALE:
PROPOSED SITE PLAN
1" = 20'-0"
722400-0340
722400-0335
722400-0330
(E) RESTAURANT
0'10'20'40'80'
VACANT
CN
R-10
CN
CN
CN
CN
R-10
R-10
R-10
R-10
R-10
R-10
R-10
R-10
R-10
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
CNCN
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
CN
R-8 R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-10
SCALE:
VICINITY MAP
1" = 100'-0"
TANGO PROPERTIES LLC
RESTAURANT REMODEL
247 PARK AVE N.
RENTON, WA 98057
REGISTERED
ARCHITECT
STATE OF WASHINGTON
12602
JINNY PARK ARCHITECTURE, PLLC
JINNYPARKARCH.COM
425.445.2993COPYRIGHT C 2018-2019
JINNY PARK ARCHITECTURE, PLLC
ALL RIGHTS RESERVED
JINNYLEEPARK@GMAIL.COM
N