Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MFP19005628.pdf
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP19005628 IVR Number: 19005628 Permit Informaon Permit Name:Verizon - MCI Address/Locaon :10/21/2019Application Date:2423049037Parcel Number:1400 MONSTER RD SW Permit Type:11/04/2019Issue Date:Franchise Permit Work Class:11/03/2020Expiration Date:Minor Utility Job Number:Jackson PL SW and Monster RD SW stagingFranchise Type:Telephone Description:Areas outlined in plans to be used for staging equipment and access to tower via aerial lift. Contacts Name Address PhoneTypeBilling HOLLY NORTH MGC TECHNICAL CONSTULTING, INC 8521 154th Ave NE REDMOND, WA 98052 B: (206) 618-0651Applicant Louise Popelka Verizon MCI Buisness 3245 158th Ave SE Bellevue, WA 98008 B: (425) 240-0238Contact Matthew Sapp Verizon - MCI Contact RANDY GAROUTTE NW UTILITIES SERVICES LLC PO BOX 1008 Sumner, WA 98390-0190 B: (253) 891-7802 C: (206) 396-8304 Contact VECTRA LLC 7404 S 262ND ST KENT , WA 98032 Owner Diann Alexander Verizon MCI Buisness - Billing 151 Stewart Rd SW, Bldg A Pacific, WA 98047 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date MCI/Verizon NW UTILITIES SERVICES LLC JACKSON PL SW & MONSTER RD SW STAGING 425-657-9361 TOM MAHEDY THOMAS.MAHEDY@VERIZONWIRELESS.COM 1400 MONSTER RD SW, RENTON, WA, 98057 JACKSON PL SW & MONSTER RD SW STAGING AREAS OUTLINED IN PLANS TO BE USED FOR STAGING EQUIPMENT AND ACCESS TO TOWER VIA AERIAL LIFT. 10/15/19 NWUTIUS927RB 253-891-7802 24274 PERMIT #: MFP19005628 Scott Warlick Holly Powers 11/4/2019 11/4/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: JACKSON PL SW & MONSTER RD SW STAGING MFP19005628 NW UTILITIES SERVICES LLC 253-891-7802 TOM MAHEDY 425-657-9361 3245 158TH AVE SE, BELLEVUE, WA 98008 THOMAS.MAHEDY@VERIZONWIRELESS.COM JACKSON PL SW & MONSTER RD SW N OF SW GRADY WAY Reset FormPrint Form MACKENZIE GREEN 10/22/19 Monday - Friday 8:00AM - 3:00PM Scott Warlick 10/25/2019 SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-TCPS.dwgPERMIT NUMBER: MFP19005628 CONFIDENTIAL/PROPRIETARYSHEET: OF 12Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE WITH CONTROLLED INTERSECTION (FOR URBAN ARTERIALS ROADTYPE)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG JACKSON PL SW (SE BOUND LANE)RENTON TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGENDSCOPE OF WORK:WORK AREA TO BE USED FOR STAGING EQUIPMENTAND ACCESS TO TOWER VIA AERIAL LIFT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESFLAGGER STATION - FOR VEHICULARAND PEDESTRIAN TRAFFIC CONTROL35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTROADWORKAHEADONE LANEROADAHEADSIGN LEGENDW20-1W20-4XW20-7XXW20-1W20-4XXW20-7XW20 -7W3-4W20 -1XXXJACKSON PL SWMONSTER RD SW 1200 MONSTER RD SWPARCELS NO.24230490101400 MONSTER RD SWPARCELS NO.2423049037PARCELS NO.2423049075WORK AREA19'X107'BEPREPAREDTO STOP50'-100'WORKVEHICLEVERIZON CONTACT:TOM MAHEDY3245 158TH AVE SEBELLEVUE, WA 98008C. 425.657.9361THOMAS.MAHEDY@VERIZONWIRELESS.COM2' MINMFP19005771 NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-TCPS.dwgPERMIT NUMBER: MFP19005628 CONFIDENTIAL/PROPRIETARYSHEET: OF 22Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SHOULDER CLOSURE (FOR URBAN ARTERIALS ROADTYPE)TRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG MONSTER RD SW (SOUTH BOUND LANE)RENTON TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGENDSCOPE OF WORK:WORK AREA TO BE USED FOR STAGING EQUIPMENTAND ACCESS TO TOWER VIA AERIAL LIFT.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICES35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTROADWORKAHEADSIGN LEGENDJA C K S O N P L S W MONSTER RD SW 1200 MONSTER RD SWPARCELS NO.24230490101400 MONSTER RD SWPARCELS NO.2423049037PARCELS NO.2423049075W20-1W21-5W20-1X W21-5W20-1XSHOULDERWORK WORK AREA 10'X142'VERIZON CONTACT:TOM MAHEDY3245 158TH AVE SEBELLEVUE, WA 98008C. 425.657.9361THOMAS.MAHEDY@VERIZONWIRELESS.COMWORKVEHICLE 2' MINMFP19005771 NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-PLANS.dwgPERMIT NUMBER: MFP19005628 © 2019 Microsoft Corporation © 2019 HERE © 2019 Microsoft Corporation © 2019 HERE SITE LOCATIONSHEET INDEXSCOPE OF WORK:AREAS OUTLINED IN PLANS TO BE USED FORSTAGING EQUIPMENT AND ACCESS TOTOWER VIA AERIAL LIFT.Know what'sbelow.before you dig.CallRSHEET4CONFIDENTIAL/PROPRIETARYSHEET: OF 14CONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMVERIZON CONTACT:TOM MAHEDY3245 158TH AVE SEBELLEVUE, WA 98008C. 425.657.9361THOMAS.MAHEDY@VERIZONWIRELESS.COMADDRESS: 1400 MONSTER RD SW, RENTON, WA, 98057PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGING - PLANS1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4. DESIGN VIEW AMFP19005628 NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-PLANS.dwgPERMIT NUMBER: MFP19005628 Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 24#F#F#F##LEGENDMFP19005628 NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-PLANS.dwgPERMIT NUMBER: MFP19005628 GENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 34The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP19005628 NO.123PROJECT NAME: JACKSON PL SW & MONSTER RD SW STAGINGVERIZON ENGINEER: TOM MAHEDYENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1400 MONSTER RD SWRENTON, WA, 98057DRAWING NAME: VERIZON-JACKSON PL SW AND MONSTER RD SW STAGING-PLANS.dwgPERMIT NUMBER: MFP19005628 CONFIDENTIAL/PROPRIETARYSHEET: OF 44CONSTRUCTION NOTES119'X107' WORK ZONE TO BE USED FOR STAGINGEQUIPMENT AND ACCESS TO TOWER VIA AERIAL LIFT.DESIGN VIEW A Know what'sbelow.before you dig.CallR107'142'JACKSON PL SWMONSTER RD SW 1200 MONSTER RD SWPARCELS NO.24230490101400 MONSTER RD SWPARCELS NO.2423049037PARCELS NO.242304907519'1 0 '5'5'5'14'14'5'8'5'1'12 .5 ' 1 2 . 5 ' 4'5'6. 5 '210'X142' WORK ZONE TO BE USED FOR STAGINGEQUIPMENT AND ACCESS TO TOWER VIA AERIAL LIFT.12CONTRACTOR TO USE EXTREME CAUTIONWHEN WORKING NEAR OVERHEAD POWER AND UTILITIESRADIO TOWER WORK LOCATIONCONTRACTOR TO USE EXTREME CAUTIONWHEN WORKING NEAR OVERHEAD POWER AND UTILITIES60'14'38'8'4 7 ' 6' 3 0 ' 1 1 'WORK AREA2033 SQ FTWORK AREA1420 SQ FTMFP19005628