HomeMy WebLinkAboutR-394625CONSTRUCTION NOTES
0
N
N
0
co
0
i
0
0
0
0
z
w
0
0
0
0
0
00
0
z
0
z
w
cn
c�
w
D
0
i
— FO
MATCH LINE STA 14+50 THIS SHEET
PIPE SIZE CHART
GPM
SIZE
0 — 8
3/4"
8 — 15
1"
15 — 22
11/4"
22 — 35
1 y2"
35 — 55
2"
NOTE: ALL IRRIGATION MAII`
SHALL BE 1Y4" PVC SCH 4(
UNLESS OTHERWISE NOTED
PLANS
S2ND ST
SPRAY SYSTEM FOR PLANTERS
20 40
SCALE IN FEET
0 10 20 40 60
MATCH LINE STA 14+50 THIS SHEET SCALE IN FEET
1 /2" FEMALE ADAPTER
FOR 1 /4" MICROTUBING
1 /2" PVC NIPPLE
1/2" PVC RISER
BRICK SUPPORTS, TYP.
EACH CORNER
PVC LATERAL
SUPPLY LINE
SIZE AS
NEEDED
%��%
S x T ADAPTER, SIZE AS NEEDE
(TEE WHERE APPLICABLE FOR
SUPPLY TO NEXT LUMINAIRE)
PVC TEE OR ELBOW
0 ALL CONTROL VALVES TO BE LOCATED IN PLANTER AREAS. INSTALL
VALVE BOX TIGHT TO EDGE OF PAVEMENT TO MAXIMIZE PLANTING
AREA. LOCATION SHOWN IS DIAGRAMMATIC
0 INSTALL MAIN AND LATERAL LINES IN PLANTER AREA WHEREVER
POSSIBLE, LOCATION SHOWN IS DIAGRAMMATIC.
OCOORDINATE MAIN LINE AND LATERAL LINE INSTALLATION WITH
ILLUMINATION CONDUIT LOCATIONS.
0 REMOVE EXISTING IRRIGATION CONTROLLER FROM SE CORNER OF
BUILDING AT THE "LOFTS AT SECOND AND MAIN". INSTALL NEW
IRRIGATION CONTROLLER (TO BE PROVIDED BY THE CITY OF RENTON);
LOCATION SHOWN IS APPROXIMATE. COORDINATE WITH COSMOS
DEVELOPMENT COMPANY FOR POWER AND PHONE CONNECTION, AND
LOCATION OF EXISTING CONDUIT FOR WIRE RUNS. EXTEND IRRIGATION
WIRING, INCLUDING SPARE WIRING, FROM NEW CONTROLLER TO
PROPOSED IRRIGATION VALVES. EXTEND IRRIGATION WIRING TO
RECONNECT EXISTING VALVES.
0
EXISTING METER AND POINT OF CONNECTION FOR THE "LOFTS AT
SECOND AND MAIN".
EXISTING SLEEVING FOR IRRIGATION MAIN LINE AT BACK OF CURB;
0 6
LOCATION SHOWN IS APPROXIMATE. EXTEND IRRIGATION MAIN
THROUGH SLEEVING TO NORTH SIDE OF 2ND AVENUE. CONTRACTOR
MAY USE 3/4" POLYPIPE AS NECESSARY TO EXTEND MAINLINE FROM
EXISTING POC TO ACCESSIBLE LOCATION IN PAVEMENT ON SW CORNER
OF MAIN AND 2ND. LOCATE CONNECTION FOR POLYPIPE TO 1-1/14"
RIGID PVC IN PAVEMENT RATED VALVE BOX FOR FUTURE ACCESS.
CONNECT TO EXISTING IRRIGATION MAIN LINE IN PLANTER; LOCATION
0 Z
SHOWN IS APPROXIMATE. COORDINATE WITH COSMOS DEVELOPMENT
COMPANY FOR LOCATION OF EXISTING MAIN LINE.
INSTALL DRIP IRRIGATION IN PEDESTRIAN LUMINAIRE POLE. SUPPLY
0 8
EQUIPMENT AS SPECIFIED; SEE DETAILS, SHEET 33B AND
ILLUMINATION DETAILS, SHEET 26
INSTALL DRIP ACCESS VALVE BOX IN PAVEMENT OR PLANTER FOR
0 9
DRIP CONNECTION TO LUMINAIRE; SEE IRRIGATION DETAILS THIS
SHEET, SHEET 33B AND ILLUMINATION DETAILS, SHEET 26
CONNECT MAINLINE TO DRIP CONTROL VALVE, SEE SPRAY IRRIGATION
2
10
SYSTEM THIS SHEET.
O11
EXISTING LATERAL DRIP LINE, SLEEVING AND DRIP CONTROL VALVE
FOR THE SOUTH SIDE OF S 2ND ST AND THE WEST SIDE OF
BRONSON WAY ARE NOT SHOWN ON PLAN. EXTEND PIPING AS
REQUIRED FROM DRIP ACCESS BOXES, INSTALL CONNECTION PER DRIP
CONNECTION DETAIL AND EXTEND DRIP PIPING THROUGH SLEEVING TO
LUMINAIRE POLE.
DRIP ACCESS
VALVE BOX, SEE GENERAL EXISTING POLYPIPE IN HDPE SLEEVING FROM EXISTING TREE WATERING
NOTES SHEET 33B 2 12 ZONE. CUT INTO AND EXTEND TO PLANTER. LOCATE CONNECTION IN
FINISH GRADE PLANTING NEW PLANTER AREA. CONTRACTOR SHALL INSTALL NETAFIM TECHLINE
AREA CV DRIP EMITTER SYSTEM, CONNECTED TO TREE WATERING ZONE, FOR
PLANTER AREA THIS LOCATION ONLY.
BARK A 13 INSTALL 2 FLEXIBLE 3/4" POLYPIPES IN SLEEVE UNDER NEW
0
MULCH CROSSWALK PAVEMENT TO PLANTING AREA, FOR PLANTER IRRIGATION
AND DRIP IRRIGATION TO ILLUMINATION POLE FLOWER BASKETS.
TOPSOIL TYPE A, TY&
1 /4" MICROTUBING TO
PEDESTRIAN LUMINAIRE POLE
1" CONDUIT SWEEP TO
LUMINAIRE BASE, SEE SHEET 26
COMPACTED SUBGRADE
DRIP ACCESS VALVE BOX IN PLANTER FOR CONNECTION TO LUMINAIRE POLE
0
IRRIGATION SCHEDULE
SYMBOL MANUFACTURER MODEL NO.
L ®
6Q 6H RAINBIRD 1806-6 VAN SERIES
4 44
EST SST
RAINBIRD
1806-15 STRIP SERIES
�
RAINBIRD
1806-15 END STRIP, W/ PCS 030
8Q A
RAINBIRD
1806 8 VAN SERIES
DRIP IRRIGATION LEGEND
SYMBOL
DRIP CONNECTION VALVE BOX
� D
DRIP CONTROL VALVE
SEE SHEET 33B FOR IRRIGATION
SCHEDULE, DETAILS AND
GENERAL NOTES.
WAI