Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-394602
LUMINAIRE SCHEDULE CONSTRUCTION NOTES (CONTINUED) N 0 N N C7, 0 00 0 i O C) 0 i z c� w 0 0 0 0 LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT BASE CIRCUIT # COMMENTS 1 52+08.1 31.4' LT DEC PEDESTRIAN 60W, LED, 700mA, (S—III, B2—UO—G1), 4000K, 240V 2' 15' FIXED 5 02 30+43.4 19.5' LT DEC PEDESTRIAN 60W, LED, 700mA, (S—III, B2—UO—G1), 4000K, 240V 2' 15' FIXED 5 < 30+79.8 17.6' RT DEC PEDESTRIAN 60W, LED, 700mA, (S—III, B2—UO—G1), 4000K, 240V 2' 15' FIXED 5 < 16+33.2 34.3' RT DEC PEDESTRIAN 60W, LED, 700mA, (S—III, B2—UO—G1), 4000K, 240V 2' 15' FIXED 5 Al * * DEC ROADWAY 10OW, LED, 700mA, (S—III, B2—UO—G2), 4000K, 240V * 30, FIXED 1 *SEE POLE SPECIFICATION SHEET * * DEC ROADWAY 10OW, LED, 700mA, (S—III, B2—UO—G2), 4000K, 240V * 30, FIXED 1 *SEE POLE SPECIFICATION SHEET * * DEC ROADWAY 10OW, LED, 700mA, (S—III, B2—UO—G2), 4000K, 240V * 30, FIXED 1 *SEE POLE SPECIFICATION SHEET 4 * * DEC ROADWAY 10OW, LED, 700mA, (S—III, B2—UO—G2), 4000K, 240V * 30, FIXED 1 *SEE POLE SPECIFICATION SHEET 60W �_ 60W CKT #5: 2—#8 iN CKT #6: 2—#6 �260W � 100W A4 A3 (4)10W* i 100W sow ; �I CKT #5: 2—#8 CKT #4: 2—#6 CKT #6: 2—#8 EX1 PANEL SCHEDULE 60W EX2 60W EX3 +-� 60W EX4 � 60W EXS�60W � CKT #1: 2—#8 I 100W A2 100W — � — Al ONE -LINE DIAGRAM N TS ELECTRICAL SERVICE CABINET "S1" # Sl LOCATION: MAIN AVE S, APPROX. STA 15+19.2, 38' RT VOLTS: 120/240 PHASE: 1 SERVING: SIGNAL, ILLUMINATION MAIN BREAKER: 200 AMPS WIRE: 3 CKT TRIPq TRIP CKT # LOAD DESCRIPTION KVA 30 KVA LOAD DESCRIPTION # -AMPMPS 2.7 SIGNAL 2 1 ILLUMINATION (A1,A2,A3,A4) 0.5 20 20 20 5 s 20 1•2 RECEPTACLES 4 ILLUMINATION (1,2,3,4,EX1,EX2, 0.2 LED UPLIGHT LUMINAIRES 6 5 EX3,EX4,EX5) 0.7 8 15 s 10 15 0.1 LTG CONTROL 8 1.0 GFI OUTLET 10 9 ILLUMINATION SPARE — 20 — PLAZA LIGHTING SPARE 12 » 12 20 U— 14 13 BLANK — — BLANK 14 REMARKS: ALL LIGHTING CIRCUITS SHALL BE CONTROLLED BY PHOTOCELL ON SIGNAL POLE #1. ONLY CKT #6 SHALL CONNECTED LOAD: 6.2 KVA 25.9 AMPS BE CONNECTED TO THE SLIDING DIMMER SWITCH. DEMAND LOAD (125%): 7.8 KVA 32.5 AMPS SIGN SCHEDULE a o QOlvsou mm 0 D3-1 (24" x 78") D3-1 (24" x 96") 0 R3-1 (24" x 24") TURNING VEHICLES WIRE NOTES GOB O� ISJ�p� n ��,ol 14 1 2" SPARE 2 3" SPARE 3 2" 6 2 4 2" 2 1 5 2" 2 6 2" 2 2 7 3" 4 2 1 1 8 3" 2 1 1 9 2" 4 2 10 3" 4 2 1 11 3" EX 1 12 3" 3 2 1 1 13 3" 2 2 14 2" 2 3 15 2" 3 16 EX 2 2 EX WIRING TO REMAIN 17 2" EX 1 FEED EX 1-12CT 18 2" 1 19 EX 2 20 EX EX 1 EX WIRING TO REMAIN 21 3" 4 2 2 1 1 22 N/A 1 LED UPLIGHT LUMINAIRES NOTES: 1. ALL PROPOSED SIGNAL CONDUIT SHALL BE RIGID PVC SCH40, EXCEPT UNDER VEHICLE TRAVEL WAY USE RIGID PVC SCH80. 2. ALL CONDUITS CONTAINING CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG). CONDUITS THAT DO NOT CONTAIN ELECTRICAL CONDUCTORS SHALL INCLUDE A DETECTABLE PULL TAPE AND SHALL BE LABELED "CITY OF RENTON". CONSTRUCTION NOTES O CONSTRUCT FOUNDATION PER WSDOT STD DETAIL J-26.10 AND INSTALL POLE AND BASE FOR DECORATIVE TYPE III SIGNAL POLE. SIGNAL MAST ARM SHALL BE PROVIDED TO THE CITY FOR FUTURE INSTALLATION. CAP MAST ARM SIMPLEX MOUNT WITH COLOR —MATCHED, WEATHER TIGHT COVER. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO APS STYLE PEDESTRIAN PUSH BUTTON ASSEMBLIES, ONE STREET NAME SIGN, AND ONE TERMINAL CABINET ON THE POLE. INSTALL ONE DECORATIVE ROADWAY LUMINAIRE WITH PHOTOCELL ON THE LUMINAIRE ARM, SEE LUMINAIRE SCHEDULE, THIS SHEET. FOR DETAILS AND LOCATION SEE SIGNAL POLE SPECIFICATIONS SHEET 25. SEE SPECIAL PROVISIONS. © CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-20.10 AND INSTALL TYPE PPB POLE. INSTALL ONE APS STYLE PEDESTRIAN PUSH BUTTON ASSEMBLY ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-26.10 AND INSTALL DECORATIVE TYPE III SIGNAL POLE. INSTALL TWO VEHICLE SIGNAL HEADS, ONE TYPE 721 EMERGENCY PRE—EMPTION DETECTOR, ONE VEHICLE DETECTION CAMERA, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE DECORATIVE ROADWAY LUMINAIRE ON THE LUMINAIRE ARM, SEE LUMINAIRE SCHEDULE, THIS SHEET. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO APS STYLE PUSH BUTTON ASSEMBLIES AND ONE TERMINAL CABINET ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. ® CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-20.10 AND INSTALL TYPE PPB POLE. INSTALL ONE APS STYLE PEDESTRIAN PUSH BUTTON ASSEMBLY ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. Og LOCATION OF EXISTING POWER SOURCE. FURNISH AND INSTALL CONDUIT AND WIRING FROM POWER SOURCE TO NEW ELECTRICAL SERVICE CABINET PER WIRE NOTES. SPLICING AT POWER SOURCE BY OTHERS. COORDINATE POWER HOOK UP WITH PSE REPRESENTATIVE. 10 CONSTRUCT JOINT CONTROLLER/SERVICE FOUNDATION PER CITY OF RENTON STD. PLAN 126.2. FURNISH AND INSTALL TS2—TYPE 1 "P+" SIGNAL CONTROLLER CABINET WITH INTEGRAL BBS, AND ELECTRICAL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1, EXCEPT MATCH CIRCUITS PER PANEL SCHEDULE, THIS SHEET AND INCLUDE ONE SLIDING DIMMER SWITCH FOR THE LED UPLIGHT CIRCUIT. INSTALL ONE FIBER PATCH PANEL, AND PTZ CAMERA EQUIPMENT SEE SPECIAL PROVISIONS. CENTER OF FOUNDATION LOCATED AT APPROX. MAIN AVE S, STA 15+19.2, 38' RT, VERIFY FINAL LOCATION WITH THE ENGINEER IN THE FIELD. COORDINATE ELECTRICAL SERVICE METER BASE INSTALLATION WITH THE POWER COMPANY REPRESENTATIVE. SEE SPECIAL PROVISIONS. 11 VIRTUAL LOOP DETECTION ZONE (SHOWN FOR REFERENCE ONLY). FINAL ZONE LOCATIONS TO BE DETERMINED BY THE ENGINEER IN THE FIELD. 12 EXISTING LUMINAIRE AND POLE TO REMAIN. PROTECT LUMINAIRE AND ALL ASSOCIATED EQUIPMENT/WIRING DURING CONSTRUCTION. 13 CONSTRUCT PEDESTRIAN LUMINAIRE POLE FOUNDATION AND FURNISH AND INSTALL DECORATIVE PEDESTRIAN LUMINAIRE POLE AND BASE WITH LUMINAIRE, FLEXIBLE IRRIGATION CONDUIT, PLANT AND BANNER SUPPORT ARMS AND BRACKETS, DUPLEX WEATHERPROOF RECEPTACLE AND ALL ASSOCIATED EQUIPMENT/CONDUIT/WIRING PER LUMINAIRE SCHEDULE, THIS SHEET AND PEDESTRIAN LUMINAIRE POLE AND DETAIL, SHEET 26. C11_4_ REPLACE EXISTING JUNCTION BOX WITH NEW JUNCTION BOX WITH NON SKID LID AND FRAME PER THE PLANS AND MATCH PROPOSED GRADE. PRESERVE AND PROTECT WIRING CONTINUITY DURING CONSTRUCTION. 15 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING SIGNAL CONTROLLER AND ALL ASSOCIATED EQUIPMENT/WIRING. SALVAGE PER SPECIAL PROVISIONS. REMOVE EXISTING FOUNDATIONS AND BACKFILL AND COMPACT PER SPECIAL PROVISIONS. (16) FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING LUMINAIRE POLE WITH SIGNAL EQUIPMENT AND ALL ASSOCIATED EQUIPMENT/WIRING. REMOVE EXISTING SIGNAL POLE FOUNDATION AT LEAST 3 FEET BELOW THE FINISHED GRADE. REMOVE EXISTING LUMINAIRE, POLE, ASSOCIATED EQUIPMENT, AND UNUSED WIRING. REMOVE EXISTING POLE FOUNDATION AT LEAST 3 FEET BELOW FINISHED GRADE. SEE SPECIAL PROVISIONS. �g REMOVE EXISTING JUNCTION BOX AND ASSOCIATED ELBOW/WIRING. CAP AND ABANDON ALL EXISTING UNUSED CONDUIT. BACKFILL AND COMPACT PER SPECIAL PROVISIONS. �g REPLACE EXISTING JUNCTION BOX WITH NEW TYPE IV HEAVY—DUTY JUNCTION BOX (PER WSDOT STD PLAN J-40.20) WITH NON SKID LID AND FRAME. MATCH PROPOSED GRADE. PRESERVE AND PROTECT EXISTING WIRING AND CONDUIT CONTINUITY DURING CONSTRUCTION. QO INSTALL SMALL CABLE VAULT AND MOUNTING HARDWARE PER WSDOT STD PLAN J-90.21 WITH NON SKID LID AND FRAME. MATCH PROPOSED GRADE. C21 INSTALL NEW CONDUIT AND WIRING INTO JUNCTION BOX PER WIRE NOTES. PRESERVE AND PROTECT EXISTING WIRING AND CONDUIT CONTINUITY DURING CONSTRUCTION. COMPLETE WIRING PER WIRE NOTES, THIS SHEET. Q ABANDON EXISTING TELEMETRY WIRING AND CONDUIT EAST OF JUNCTION BOX. REMOVE EXISTNG TELEMETRY WIRING WEST OF JUNCTION BOX AND ABANDON TELEMETRY CONDUIT. Q UNSPLICE EXISTING ILLUMINATION WIRING FROM EXISTING WIRING LEADING TO EXISTING ELECTRICAL SERVICE. EXISTING ILLUMINATION WIRING NORTH OF SPLICE TO REMAIN. COMPLETE WIRING PER THE WIRE NOTES. Q HAND EXCAVATE AND FIELD LOCATE EXISTING CONDUIT. UNSPLICE EXISTING WIRING AND PULL BACK TO NEAREST PULL POINT. INTERCEPT AND CONNECT NEW CONDUIT TO EXISTING CONDUIT AND COMPLETE WIRING PER WIRE NOTES, THIS SHEET. 25 LOCATION OF EXISTING COMCAST COMMUNICATION VAULT. DO NOT DISTURB DURING CONSTRUCTION. ALL WORK SHALL BE DONE BY OTHERS, COORDINATE WORK WITH COMCAST REPRESENTATIVE. 46 FOLLOWING ACTIVATION Of NEW SIGNAL SYSTEM, REMOVE EXISTING TYPE PS SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT/WIRING. SALVAGE PER SPECIAL PROVISIONS. REMOVE EXISTING SIGNAL POLE FOUNDATION. Q PULL EXISTING 12CT FIBER OPTIC CABLE FROM THE SW CORNER OF S 2ND ST &WELLS AVE S TO THIS LOCATION. INSTALL ONE FIBER OPTIC PRE —TERMINATED PATCH PANEL AND COMPLETE WIRING PER WIRE NOTES. - - - -,. - ... TEGT LUMINAIRE AND ALL AsseelATED EQUIPMENT DURING 6ONSTRU6TIONT— (NOT USED) O CONSTRUCT FOUNDATION PER WSDOT STD DETAIL J-26.10 AND INSTALL POLE AND BASE FOR DECORATIVE TYPE III SIGNAL 29 FURNISH AND INSTALL LED UPLIGHT LUMINAIRE PER URBAN DESIGN DETAILS, SHEET 31. SEE SPECIAL PROVISIONS. POLE. INSTALL TWO VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE DECORATIVE ROADWAY LUMINAIRE ON THE LUMINAIRE ARM, SEE LUMINAIRE SCHEDULE, THIS 30 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING TYPE II SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT/WIRING. SALVAGE PER SHEET. INSTALL ONE VEHICLE SIGNAL HEAD, ONE PEDESTRIAN SIGNAL HEAD, ONE APS STYLE PUSH BUTTON ASSEMBLY SPECIAL PROVISIONS. REMOVE EXISTING SIGNAL POLE FOUNDATION AT LEAST 3 FEET BELOW THE FINISHED GRADE. AND ONE TERMINAL CABINET ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. PUSH BUTTON SCHEDULE O CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-21.10 AND INSTALL DECORATIVE TYPE I POLE. INSTALL ONE VEHICLE vTo SIGNAL HEAD, ONE PEDESTRIAN SIGNAL HEAD AND ONE APS STYLE PEDESTRIAN PUSH BUTTON ASSEMBLY ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. 0 0 NOTE: D3-1 (36" x 144") R10-15R (30" x 30") 1. SIGNS ARE NOT TO SCALE. 2. ALL SIGN DIMENSIONS SHALL BE VERIFIED WITH THE ENGINEER AND MANUFACTURER PRIOR TO FABRICATION. 3. FOR MAST ARM MOUNTED STREET NAME SIGN USE 12 INCH C—SERIES NUMERALS AND LETTERS. 4. BACK OF MAST ARM SIGNS AND MOUNTING EQUIPMENT SHALL BE PAINTED TO MATCH SIGNAL MAST ARM COLOR. ® CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-26.10 AND INSTALL DECORATIVE TYPE III SIGNAL POLE. INSTALL TWO VEHICLE SIGNAL HEADS, ONE TYPE 721 EMERGENCY PRE—EMPTION DETECTOR, ONE VEHICLE DETECTION CAMERA, ONE REGULATORY SIGN, AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE DECORATIVE ROADWAY LUMINAIRE ON THE LUMINAIRE ARM, SEE LUMINAIRE SCHEDULE, THIS SHEET. INSTALL ONE VEHICLE SIGNAL HEAD, ONE REGULATORY SIGN, ONE TYPE 721 EMERGENCY PRE—EMPTION DETECTOR, ONE PTZ CAMERA, TWO PEDESTRIAN SIGNAL HEADS, TWO APS STYLE PUSH BUTTON ASSEMBLIES AND ONE TERMINAL CABINET ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION PER WSDOT STD PLAN J-20.10 AND INSTALL TYPE PPB POLE. INSTALL ONE APS STYLE PEDESTRIAN PUSH BUTTON ASSEMBLY ON THE POLE. FOR POLE LOCATION AND DETAILS SEE SIGNAL POLE SPECIFICATION SHEET 25. SEE SPECIAL PROVISIONS. POLE # PUSH BUTTON 0 ARROW DIRECTION SIGN CUSTOM WALK VOICE MESSAGE 1 29 LEFT R10-4e(L) 2ND STREET WALK SIGN IS ON TO CROSS 2ND STREET 1 48 RIGHT R10-4e(R) MAIN AVENUE WALK SIGN IS ON TO CROSS MAIN AVENUE 2 49 LEFT R10-4e(L) NONE 3 18 RIGHT R10-4e(R) NONE 5 19 LEFT R10-4e(L) NONE 6 88 RIGHT R10-4e(R) NONE 7 89 LEFT R10-4e(L) NONE 8 28 RIGHT R10-4e(R) NONE