PREAPPLICATION MEETING FOR
Wofford Residential Development
2600 Block of NE 26th Place
PRE 15-000698
CITY OF RENTON
Department of Community & Economic Development
Planning Division
October 29, 2015
Contact Information:
Planner: Jill Ding, 425.430.6598
Public Works Plan Reviewer: Vicki Grover, 425.430.7291
Fire Prevention Reviewer: Corey Thomas, 425.430.7024
Building Department Reviewer: Craig Burnell, 425.430.7290
Please retain this packet throughout the course of your project as a reference.
Consider giving copies of it to any engineers, architects, and contractors who work on
the project. You will need to submit a copy of this packet when you apply for land
use and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and
the proposal will be formally reviewed under the regulations in effect at the time of
project submittal. The information contained in this summary is subject to
modification and/or concurrence by official decision-makers (e.g., Hearing Examiner,
Planning Director, Development Services Director, Department of Community &
Economic Development Administrator, Public Works Administrator and City Council).
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: October 28, 2015
TO: Jill Ding, Planner
FROM: Vicki Grover, Plan Reviewer
SUBJECT: Wofford Residential Development
2600 block of NE 26th Place
PRE 15-000698
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-binding
and may be subject to modification and/or concurrence by official City decision-makers. Review comments
may also need to be revised based on site planning and other design changes required by City staff or made by
the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcels 3343902061,
3343902124, & 3343902120. The following comments are based on the pre-application submittal made to the
City of Renton by the applicant.
Water
The proposed development is within the City of Renton’s water service area and in the 435-hydraulic zone.
The development is within Zone 2 of the City’s aquifer protection area.
There is an existing 8-inch main within a City-owned utility easement in NE 26th Place and along the south
property line of tax lot 3343902061 and also across tax lot 3343902062 (refer to City water project plan no. W-
2162). The 8-inch water line can deliver 2,000 gallons per minute and the static water pressure is about 73 psi
at ground elevation of 264 feet.
If there are any lot line changes, the location of the 8-inch water main will need to be accounted for in an
easement. If the property lines are left as they currently are, a 7.5 ft. set back from the edge of the easement
for all structures is required.
The following water improvements will be required to provide water service to the proposed
residential subdivision:
1. Installation of a fire hydrant within 300 feet of each proposed lot.
2. Installation of a new 1-inch minimum domestic water service line and meter to each lot.
3. Installation of a residential fire sprinkler is the proposed dwellings exceed 3,600 sq-ft or if otherwise
required by Fire Prevention Department.
4. Subject to payment of applicable water system development charges and of water meter
installation fees.
Sanitary Sewer
Wofford Residential Development Pre-App 15-000698
Page 3 of 5
October 28, 2015
3
1. The site is within the City of Renton’s sewer service area. There is an existing 16-inch diameter PVC
interceptor line running east-west from Aberdeen Avenue NE along NE 26th Place within the same City-owned
utility easement as the water line.
2. If there are any lot line changes, the location of the interceptor line will need to be accounted for in an
easement. If the property lines are left as they currently are, a 7.5 ft. set back from the edge of the easement
for all structures is required.
3. There are two stubs for the parcels 3343902124 & 3343902120; however, parcel 3343902061 does not have
an existing sewer stub due to the site’s topography. This parcel may require a grinder pump in order to
connect to the existing sewer.
4. The Sanitary Sewer System Development Charges (SDC) are based on the size of each domestic water
meter(s). These fees are collected at the time a construction permit is issued. This project falls within the
boundaries of the Kennydale Interceptor Special Assessment District (SAD). The SAD fee is $666.88 per single
family house and a frontage charge of $5,266.25 per lot.
TRANSPORTATION/STREET
1. The current transportation impact fee rate is $2,214.44 per new single family house. The transportation
impact fee that is current at the time of building permit application will be levied. Payment of the
transportation impact fee is due at issuance of the building permit.
2. Road Classification – Aberdeen Avenue NE / Collector Arterial.
3. Referring to RMC 4-6-060J. Private Streets – 26 ft. easement with a 20 ft. pavement width; no sidewalks;
drainage improvements per City Code are required, slope not to exceed 15%; the cross sections shall be 4-
inches of HMA over 6-inches of CSTC. An easement is required to create a private street. Applicant shall
submit an application to the City requesting a modification of the private street requirements as outlined
in City code 4-9-250C5d. This proposal does not meet 2 of the minimum 6 lots abut ting a public right of
way; the applicant could request for 20 ft. of pavement width and stripe it for 16 ft. for regular vehicular
traffic but would still have the 20 ft. required for fire access; this modification would require 5 ft. of
additional property from the 2 lots along the north side of the current private access off of Aberdeen Ave.
NE.
4. Referring to RMC 4-6-060H Dead End Streets – length of street from 500 ft. to 700 ft. requires a 90 ft. cul-
de-sac and a fire sprinkler system for each house. The requirement for a turnaround or a cul-de-sac may
be waived by the Administrator with the approval of Fire and Emergency Services.
5. All storm drainage improvements are required to be constructed per RMC 4-6-060.
6. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements.
7. Street lighting may be required depending on the final access/road layout.
Storm Drainage
1. There is a drainage conveyance system running east-west from Aberdeen Avenue NE along NE 26th
Place within the same City-owned utility easement as the water and sewer lines.
2. A drainage plan and drainage report will be required with the site plan application. The report shall
comply with the 2009 King County Surface Water Manual and the 2009 City of Renton Amendments to
the KCSWM. All core and any special requirements shall be contained in the report. Based on the
City’s flow control map, this site falls within the Flow Control Duration Standard, Forested Site
Conditions and is in the May Creek Drainage Basin. The drainage report will need to follow the area
specific flow control requirements under Core Requirement #3. Refer to Figure 1.1.2.A – Flow Chart to
determine the type of drainage review required by the City of Renton 2009 Surface Water Design
Manual Amendment. The final drainage plan and drainage report must be submitted with the utility
construction permit application.
3. A geotechnical report for the site is required. Information on the water table and soil permeability with
recommendations of appropriate flow control BMP options with typical designs for the site from the
geotechnical engineer shall be submitted with the application. The report shall include information to
determine if the site is suitable for infiltration and a design infiltration rate.
4. If there are any lot line changes, the location of the 24-inch storm water pipe will need to be
accounted for in an easement. If the property lines are left as they currently are, a 7.5 ft. set back
from the edge of the easement for all structures is required.
5. Surface water system development fee is $1,350.00 for each new single family residence.
6. A Construction Stormwater Permit (NPDES) from the Department of Ecology is required when clearing
and grading exceeds one acre.
General
1. Fees quoted in the pre-application document are for the 2015 calendar year. Fees change every
calendar year.
2. All construction utility permits for drainage and street improvements will require separate plan
submittals. All utility plans shall conform to the Renton Drafting Standards. Plans shall be prepared by
a licensed Civil Engineer.
3. Separate permit and fees will be required for the water meter installation, side sewer connection and
storm water connection.
Wofford Residential Development Pre-App 15-000698
Page 5 of 5
October 28, 2015
5
Fire Comments
1. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600
square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500
gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed
buildings and two hydrants if the fire flow goes up to 1,500 gpm. There are no existing fire hydrants within the
required distance.
2. The fire impact fees are applicable at the rate of $495.10 per single family unit. This fee is paid at time
of building permit.
3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved
or gravel constructed to meet fire department loading requirements and designed by a licensed soils engineer.
Turning radius are 25-feet inside and 45-feet. Fire access roadways shall be constructed to support a 30-ton
vehicle with 75-psi point loading. Approved apparatus turnarounds are required for dead end roads
exceeding 150-feet. An approved 90-foot diameter cul-de-sac type turnaround is required for dead end
streets over 300-feet long. Existing private roadway does not meet minimum fire code width standards. Proof
of access easements shall be provided or obtained. All homes on dead end streets that exceed 500-feet shall
be equipped with an approved residential fire sprinkler system.