GENERAL NOTES
1. CITY OF RENTON INTERCONNECT CONDUITS RUN
UNINTERRUPTED BETWEEN COMMUNICATION VAULT GROUPS AS
SHOWN ON THIS SHEET AND IL71. ILLUMINATION CONDUIT
SHALL BE INSTALLED AS PART OF THE JOINT UTILITY TRENCH
(JUT) AS SHOWN ON IL14 AND I1-15. ILLUMINATION CONDUIT
WILL SWEEP IN AND OUT OF THE JUT TO CONNECT THE
ILLUMINATION JUNCTION BOXES.
2. SEE SHEET IL6 FOR ILLUMINATION CONDUIT AND WIRE SIZE.
3. SEE SECTION 1-07.17 OF THE SPECIAL PROVISIONS FOR
CONSTRUCTION COORDINATION REQUIREMENTS.
LEGEND
...............
ILLUMINATION CONDUCTORS
EXISTING ILLUMINATION CONDUCTORS
.............................
INTERCONNECT FIBER
LUMINAIRE — SEE IL6
EXISTING LUMINAIRE
®
SERVICE CABINET
OOM
COMMUNICATION VAULT — SEE I1-11
s7.
34
CITY OF RENTON
TA VAULT
�v
BREAKER SCHEDULE SERVICE "S1" ® GLENNWOOD
120/240 VOLT
CIRCUIT
DESCRIPTION
BREAKER
RATING
CONTRACTOR
RATING
VOLTAGE
LOAD (KVA)
SERVICE
100 AMP
A
INTERSECTION ILLUMINATION
30 AMP
30 AMP
240
3.50
B
SPARE
30 AMP
30 AMP
240
0.00
C
PEDESTRIAN ILLUMINATION
30 AMP
30 AMP
240
3.60
D
PEDESTRIAN ILLUMINATION
30 AMP
30 AMP
240
3.60
E
SPARE
30 AMP
120
0.00
F
PHOTOCELL
15 AMP
120
0.001
G
GFR
20 AMP
120
1.80
PEAK
12.50
CONTINUOUS
10.70
RECORD DRAWING
THIS RECORD DRAWING WAS PREPARED USING
INFORMATION PROVIDED TO CONSULTANT AND
CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED.
THE INFORMATION WAS NOT INDEPENDENTLY FIELD
VERIFIED. THE CONSULTANT DOES NOT WARRANT OR
GUARANTEE THE ACCURACY OR COMPLETENESS OF THE
INFORMATION SHOWN.
."m NONE ° ' °w°�1 ® CITY ET LANE N a/2016
Mncl.as ,� CITY OF SUNSET LANE NE a°°"�
J. BEAN ' RENTON w,
DATUM IL7
P. DE BOLDT Planning/Building/Public Works Dept.
NO. REVISION BY DATE APPR "" M_ MACIAS ILLUMINATION AND INTERCONNECT ONE -LINE WIRING DIAGRAM 70 9,