HomeMy WebLinkAboutMFP19006189.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP19006189 IVR Number: 19006189 Permit Informaon Permit Name:Puget Sound Energy - Electric Address/Locaon :11/14/2019Application Date:1352300005Parcel Number:1300 BRONSON WAY N Permit Type:12/04/2019Issue Date:Franchise Permit Work Class:12/03/2020Expiration Date:Major Utility Job Number:101121708Franchise Type:Electric Description:Remove P01, install P02 with new XF and 3PH termination. Open cut across N 2nd ST, install 3PH primary along ROW to private property. Remove poles P05, P06, P07, P10, P11, and reframe P03, P09. Restoration per City of Renton standards. PRE CONSTRUCTION MEETING REQUIRED PSE and the City of Renton to meet with homeowner @203 Meadow Ave N to explain why a pole(P09) needs to be added in front of their property. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL CONSTRUCTION INDUSTRY TRAIN 1300 BRONSON WAY N RENTON , WA 98057 Owner Marita Bond Puget Sound Energy Billing 6905 S 228 St Kent, WA 98032 B: (253) 395-6346Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: տ New Construction տ Repair/Relocate տ Underground տ Overhead տ Sidewalk տ Street տ Open Trench տ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 101121708 CORRIE RYDBERG (253) 234-6410 CORRIE.RYDBERG@PSE.COM 1300 BRONSON WAY N REMOVE P01 (318003-166230), INSTALL P02 (317999-166222) WITH NEW XF AND 3PH TERMINATION. CUSTOMER TO OPEN CUT ACROSS N 2ND ST, INSTALL 3PH PRIMARY ALONG RIGHT OF WAY TO PRIVATE PROPERTY. REMOVE POLES P05,P06,P07,P10,P11. REFRAME P03,P09. PLEASE SEE ATTACHED ✔✔✔✔✔ ✔ Potelco, Inc. (253) 234-6410 POTELI#227PL BL005109 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.11.14 16:53:06 -08'00'11/14/19 MFP19006189 This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR Scott Warlick RESTORATION PER CITY OF RENTON STANDARDS Justin Johnson 12/5/2019 12/5/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: •Comply with all traffic regulations of the City of Renton and the State of Washington. •Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. •Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form 101121708 Potelco, Inc DAVE HONEYSETT (253) 245-0883 6905 S 228th St, Kent, WA 98032 DAVE.HONEYSETT@PSE.COM 1300 BRONSON WAY N TBD TBD CORRIE RYDBERG 11/14/19 Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.11.14 16:52:53 -08'00' MFP19006189 8:00AM - 3:00PM Monday - Friday Scott Warlick 12/4/2019 SKETCH I -- NORTH -- I NOTES: •Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. •The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. •Approved Temporary Traffic Control Plan must be at the work site during work hours. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. •Total road closure lasting more than 24 hours is subject to the approval by the City Council. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. •The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). N Vicinity Map 47.484280, -122.199574 101121708FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" Owner / Developer Contact Info officeATTN: CITC Vocational Training 1930 116th AVE NE #201 Bellevue, WA 98004 Patrick Hansen-Lund (858) 581-0754 505924897 101121708 108115032 583062283 ...... PROJECT PHASE PWR NOTIF#ORDER# Superior UG Expense Removal OH Expense 593210193 ...... Trf Removal Removal E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett (253) 245-0883 Dave.Honeysett@PSE.com LEGEND EXISTING PROPERTY LINE EXISTING UG RISER NEW UG RISER J-BOXJ NEW TRENCH LINE EXIST. 3Ø WIRE EXISTING CENTER LINE EXISTING CONDUCTOR TO BE REMOVED DISCONNECT - FUSED EXIST. 1Ø WIRE EXISTING RIGHT OF WAY PROPOSED PULL VAULTP EXISTING POLE DOWN GUY EXISTING SECONDARY SERVICE LINE DISCONNECT - UNFUSED EXISTING STREETLIGHT NEW POLE PROPOSED PADMOUNT TRANSFORMER EXISTING PADMOUNT TRANSFORMER HANDHOLE CITC RENTON SCHEDULE 73 OH TO UG CONVERSION NOTE: DEVELOPER TO PROVIDE ALL CIVIL WORK: TO AND INCLUDING EXCAVATION, BACKFILL, SHORING, TRENCH MAINTENANCE, SANDING FOR DUCT, SELECT 5/8" CRUSH FOR UNDER VAULTS, COMPACTION, ALL HARDSURACE RESTORATION AND RELATED LANDSCAPING RESTORATION. DEVELOPER TO PROVIDE TEMPORARY EXCAVATION PLATING (IF REQUIRED). GENERAL 1. Pre-construction Notify appropriate City or County 48 to 72 hours or as required by permitting agency before starting work on any right-of-way involving a permit. Follow all requirements as outlined by the permitting agency. Locate and mark all underground utilities prior to start of construction. If there is a conflict with the intended trench route as shown on the site plan and existing utilities or obstructions, trench route may need to be moved to opposite side of street. Cooperation with Quality Inspector, Puget Sound Energy Contractor, City or County authorities during Pre-construction meeting will determine the final trench route. 2. Existing Utilities Hand excavate (pothole) all marked utility crossings to verify exact location and depth at point of crossing. Protect underground utilities during excavation. Use hand excavation methods if necessary to avoid damage. Fabricate and install adequate temporary structures to support and protect underground utilities while exposed during construction. Maintain 6" minimum clearance at crossings between existing utilities and new duct installations. Transition trench or tunnel profile gradually as required at crossings. Maintain 24" minimum separation between new trench or tunnel and parallel existing utilities or as required by the permit agency. In the event of damage to an underground utility, notify Puget Sound Energy at once. Contractor agrees to make work force and resources available at once to Puget Sound Energy or municipal authorities to repair damage at no cost. 3. Work Drawings Maintain on site, in good condition, a complete file of all work drawings. These drawings shall be available at all times to a Puget Sound Energy representative. Corrections and changes made during the job shall be recorded continuously on these drawings. All underground electrical facilities shall have a minimum of 36 inches of cover. Any change must be approved by the PSE engineer or project manager. Furnish Puget Sound Energy a complete set of as built prints (foreman's copies) at the end of the job. 4. Safety Provide signs, barricades, and traffic control in conformance with local jurisdictions and regulations. Provide flagging and or other vehicle traffic control as needed in conformance with local regulations. (see SPM # 100.4000) Provide adequate signage and protection to traffic during non-working hours. Maintain traffic flow as required by permitting agency. Provide signs and barricades to warn pedestrians, motorcycles and bicycles. Install warning barricades at least every 50 feet along the trench route from the time the trench is opened until the trenching is complete. 5. Existing Systems Maintain existing electrical system in service until new system is complete, tested, and ready for service. Disable existing system only to make cutovers and connections as directed by Puget Sound Energy's representative. Provide temporary wiring and connections to maintain existing systems in service during construction; if a scheduled outage is not possible. When work must be performed on energized equipment or circuits, use qualified personnel for such operations. EARTHWORK See Puget Sound Energy SPM 6800.4050 1. Back hoe, Hand Dug Excavations Paved Surfaces Cut the edges of the trench prior to digging. Use the narrowest bucket practical or plow off the edge of paved surface far enough to minimize asphalt disturbance. Repair any blow out areas (where edge has been broken) by sawing. The depth of the trench shall be enough to allow 36" of cover . Backfill material shall be Controlled Density Fill (CDF) cover or select fill (5/8" minus) to meet permit requirements. Unpaved Surfaces Conduit/cable trenches are to be excavated just off the existing road edge or in the shoulder of the road behind the existing ditch line. Contractor shall use a back hoe with the narrowest width bucket practical or plow. Trench shall be deep enough to allow a minimum of 36" of cover over the top most cable. All ditch crossings shall have a minimum of 36" cover from the lowest point within the existing ditch line. Culverts; when installing facilities under a culvert, excavation must be filled with packed crush rock. If any culvert is damaged it will be repaired or replaced in accordance with permitting agency and contractors responsibility. Spoils shall be removed quickly to minimize blocking of traffic. All spoils and wastes become the property of the contractor immediately upon removal. Remove spoils and wastes promptly to an approved disposal site. Remove spoils containing asphalt or concrete to a disposal site specifically approved for such materials. Provide Puget Sound Energy with a disposal receipt for all spoils. 2. Backfill Unpaved Road Surfaces Backfill for unpaved road crossings shall consist of 1-1/2" to 2-1/2" material compacted to 95% density. Backfill for unpaved road sections shall consist of native material compacted to 95% density. At the end of each workday, backfill or plate all trench, remove all spoils and clean roadway surface of large hazardous debris. 3. Surface Restoration Unpaved Surfaces Restore ground surface to original contour. Restore to original condition or better. 4. Landscaping Arrange and perform work to minimize impact to existing landscaping. Restore landscaping that has been disturbed during the course of work, including seeding of banks and fills. Vaults set in bank areas may require re-sloping the surrounding land to avoid sloughing. Leave area in its original state or better at the end of construction. Hand dig if required to prevent damage to tree roots. ELECTRICAL 1. Conduit Conduit for installation in unpaved areas shall be 2", 3", 4", or 6" PVC DB120 or 2", 3", 4", or 6" DB120 for direct burial. Maintain 36" minimum cover above top conduit at all times or as required by the permitting agency. Where conduit is routed from road edge to vault location, maintain 36" minimum cover above top conduit at all times or as required by the permitting agency. Bends shall be made with as long a radius as possible (48" minimum). Avoid making sharp bends or kinks in conduit during installation. Obtain exact location of conduit entrance into vault from Puget Sound Energy before penetrating vault. Penetrate the vault using existing knockout or use core drilled holes. Stub the 4" or 6" PVC 2"-3" into vault interior and grout between the conduit and vault wall. Leave a 10' minimum of extra pull rope in each end of installed conduit where 4" or 6" PVC is installed and cap conduit to prevent the entry of dirt and moisture. Arrange work so conduit plays directly off reel into trench. Place the conduit in the trench as straight as possible. Avoid vertical and horizontal "snaking" of the conduit. Multiple conduit runs may be stacked vertically. Where conduit must be pulled through a trench to allow a crossing under an existing utility, cap conduit end before pulling to avoid contamination. If a kink occurs, cut the conduit ahead of kink and splice to new conduit to continue run. 2. Underground Primary Cable Primary cable shall be 1/O Alum Sol Jacketed Cable rated for 15 KV service with a polyethylene jacket. Primary cable shall be 61 strand 750 MCM aluminum conductor rated for 15 KV service with a copper tape neutral conductor and polyethylene jacket. A 4/0 copper neutral shall be run with each 3 phase circuit of 750 MCM. Install cable into existing or new conduit systems using approved installation equipment. Approved equipment includes either cable pullers and/or cable pushers. Pulling socks shall be non-conductive or similar material. Steel pulling socks are prohibited. Bare steel cable shall not be used to pull cable. Cable pulling equipment (winches, hoist, driven reels, etc.) shall be equipped with instrumentation to continually monitor and record peak tension encountered during a pull. Before installing cable, obtain rated pulling tension for cable from Puget Sound Energy. Do not exceed rating at any time during installation. Notify Puget Sound Energy immediately if pulling tension equals or exceeds rating (828/1657lbs for 1/0 or 5000lbs for 750 .) Do not exceed minimum bend radius of cable or impose kinks or sharp bends on cable during pulling operations. Install cable directly off reel without dragging it on the ground. Apply Puget Sound Energy approved lubricant to cable continually during pulling to reduce pulling tension and to permit future removal. Install adequate amounts of 3/4 " plywood on existing sidewalk areas to support pulling equipment and prevent un-necessary damage to sidewalks. Train and coil cables in vaults as required to form a smooth transition from conduit to termination. if terminations are to be performed by others, coil 15' of cable in vault and cap end. 3. Terminations and Splices Install approved terminations on cables in accordance with Puget Sound Energy SPM 2247.5115- 5119. Unless otherwise directed, approved terminations will be load break elbows in vaults and cold shrink pin terminals on pole risers per Puget Sound Energy SPM 2247.9317. Splice cable with approved splice kits in vaults, hand holes or similar enclosures. Do not splice cables in runs between vaults. See Puget Sound Energy SPM 2233.2075-2076. 4. Concrete Vaults Excavate, install base material, and compact base material in accordance with Puget Sound Energy SPM 6775.0040. Install and seal precast sections in accordance with Puget Sound Energy SPM 6775.0040. Use precast neck and shaft sections to bring manhole entrance to proper elevation. Install manholes plumb. Set the top of each manhole to finished elevation or no higher than 6" above existing road elevation. Install hillholders as required on sketch or by construction notes. 5. Grounding Install ground rod per Puget Sound Energy SPM 6275.6100 at each vault in which primary cable is terminated. Locate rod in trench excavation wherever possible to obtain maximum driven depth in undisturbed soil. Connect each ground individually to ground loop inside vault with bare no. 2 copper jumper or to Concentric neutral at each splice vault location. Minimum grounding requirement is 4 grounds per mile. 6. Existing Underground Primary Cable (if applicable) Abandon existing primary cable in place. Cut off old cable ends inside vault flush with wall. Before cutting, pigtail concentric neutral strands and connect to ground loop inside vault. Return scrap cable and existing cable tags to Puget Sound Energy. Remove or fill existing vaults as required by permitting agency. 7. Traffic Control All traffic control to comply with current specifications in M.U.T.C.D. GENERAL OVERHEAD NOTES: 1. Poles, conductors, devices to be installed per PSE Standards & Specifications. 2. Poles are to be installed or relocated as staked. 3. All new poles set shall be the class indicated on the sketch or better. 4. Install ground plate assembly on all new poles. 5. Install grid numbers on all new and existing poles as shown on sketch. 6. Treat all field-drilled poles with copper Naphthenate wood preservative. 7. Customer/Developer to coordinate between utilities. 8. All new and relocated poles -locations- to be approved by King Co. OVERHEAD CIRCUIT MAP (1602E008) SCALE: 6" = 1 MILE WORKZONE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 9/6/19 Nate Linville (253) 970-7284 9/6/19 Nate Linville (253) 970-7284 RW-______City of Renton CITC Renton Headquarters Sch 73 Schedule 73 Conversion 1300 Bronson Way N, Renton, WA 98057 101121708 AS NOTED 1 of 5 King CSPSKEPM NE-17-23N-05E 208.080 208.082 2305E066 2305E088 2305E066SE PCR-14 CENTURYLINK N/A N/A COMCAST N/A N/A PSE GAS N/A N/A ZAYO? N/A N/A WORK ZONE MFP19006189 214 215 209 205 201 208 204 1402 123 115 111 1408 1218 215 211 1210 210 203 204 200 131 1300 xxxxxxxxxxxxx x x x G G UP UPUPUPUPUPUPUPWWWWWWWWWWWWWWWWWWW W W UPUPUPUPUPUPUPUPUPWWWWWWWWWWWWWWWWWWWWGGGGGGGGGGGGGGGGGUTGGGGGGGGGGGG GGxxxxxxxxxxGGG G G G G G G G GGGGGGGGG G G G G G G SD SD SD SD SD SD SD SD SD SD S DSD SDSD SD SD SD SD SDSDSDSDSDSDSDSD SDSD SDSDSDSDSD SD SDSDSDSDSDSDSDSDSDSDSDSDSD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSDSDWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSUPUPUPUPUP UP UP UP UP UP UP UP UP UP UP UP UP UP UTUTUTUTUTUTUTUTUTUTSDSDSDSDSDS D 8" DEC(4)8" DEC24 " D E C 20" DEC18 " D E C 16" D E C 10" DEC16 " C H 30" OAK30" OAK30" OAK40" CED12" FIR12" FIR12" FIR8" FIR8" FIRxxxxxxxxxxxxxxxxxxxxxxxxxxxxxTTT T T T T T TTTTTTTTTTTTTTTTTTTTTTTTTT T ROW OF 3" CED ROW OF 3" CEDSDSDSDSSSSSS(ノ 益 )ノ彡┻━┻ 317977-166222 1X 75 kVA 120/240V 1X 10kVA 120/240V SLAG7877 317967-166222 SLAG7876 317988-166223 SLAG7878 317999-166234 25 kVA 120/240V (B) 317999-166222 UNK (65T) SLAG7879 317985-166246 3X 25 kVA 120/208V 317999-166246 SLAP0285 318003-166254 318012-166247 37.5 kVA 120/240V (B) 317998-166263 10 kVA 120/240V (B) SLAG7875 317978-166246 100 kVA 120/240V (C) SLAG7870 317999-166226 317993-166244 318008-166223 25kVA 120/240V 318003-166230 37.5 kVA 120/240V (A) T______ (65T) PROPOSED EASEMENT PROPOSED EASEMENT PROPOSED EASEMENT SWING SWING 317979-166244 300 kVA 120/208V (ABC) 317975-166244 112 kVA 120/208V (ABC) J WRECK-OUT SITE PLAN 101121708SCALE: 1" = 30' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 9/6/19 Nate Linville (253) 970-7284 9/6/19 Nate Linville (253) 970-7284 RW-______City of Renton CITC Renton Headquarters Sch 73 Schedule 73 Conversion 1300 Bronson Way N, Renton, WA 98057 101121708 AS NOTED 2 of 5 King CSPSKEPM NE-17-23N-05E 208.080 208.082 2305E066 2305E088 2305E066SE PCR-14 CENTURYLINK N/A N/A COMCAST N/A N/A PSE GAS N/A N/A ZAYO? N/A N/A 00 1"2" 00 30'60' AT P01: REMOVE 318008-166223 REMOVE EXISTING 1984 40' CL3 DISTRIBUTION POLE REMOVE EXISTING 25kVA 120/240V 2B OH TRANSFORMER, RETURN TO PSE YARD COMMUNICATIONS TO TRANSFER TO P02 LATER AT P10: REMOVE 317985-166246 REMOVE EXISTING 1984 45' CL3 DISTRIBUTION POLE REMOVE EXISTING 3X 25kVA 120/208V 1B TRANSFORMERS, RETURN TO PSE YARD COMMUNICATIONS TO REMOVE LATER AT P11: REMOVE 317978-166246 REMOVE EXISTING 1962 45' CL4 FOREIGN OWNED POLE REMOVE EXISTING 100kVA 120/240V OH TRANSFORMER, RETURN TO PSE YARD COMMUNICATIONS TO REMOVE LATER AT P12: REMOVE 317988-166223 REMOVE EXISTING 1983 40' CL4 DISTRIBUTION POLE REMOVE EXISTING POLE MOUNTED LUMINARIES, RETURN TO PSE YARD COMMUNICATIONS TO REMOVE LATER AT P13: REMOVE 317977-166222 REMOVE EXISTING 1948 45' CL4 DISTRIBUTION POLE REMOVE EXISRING 1X 75kVA 120/240V 2B OH TRANSFORMER, RETURN TO PSE YARD REMOVE EXISTING 1X 25kVA 120/240V 2B OH TRANSFORMER, RETURN TO PSE YARD REMOVE EXISTING POLE MOUNTED LUMINARIES, RETURN TO PSE YARD COMMUNICATIONS TO REMOVE LATER AT P14: REMOVE 317967-166222 REMOVE EXISTING 1967 40' CL4 DISTRIBUTION POLE REMOVE EXISTING POLE MOUNTED LUMINARIES, RETURN TO PSE YARD COMMUNICATIONS TO REMOVE LATER POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS Wk Loc Pole Data Pole TEL TV FIBER TRAN RMVD ID NUMBER Grid #Length Class Year TOPPED RMVD P01 318008-166223 40'4 1984 P05 317988-166223 40'4 1983 P06 317977-1966222 45'4 1948 P07 317967-166222 40'4 1967 P10 317985-166246 45'4 1948 P11 317978-166246 45'4 1962 WIRE REMOVAL TABLE Work Location Wire Size & Type Quantity Length (per conductor) Remarks From To P03 P05 #2 ACSR- PRI/NEUT 4 100' P05 P06 #2 ACSR- PRI/NEUT 4 110' P06 P07 #2 ACSR- PRI/NEUT 4 100' P09 P13 #2 ACSR- PRI/NEUT 4 140' P13 P14 #2 ACSR- PRI/NEUT 4 140 MFP19006189 Pse and City of Renton to meet with homeowner to explain why this pole needs to be added. 8" DEC(4)8" DEC24 " D E C 20" DEC18 " D E C 16" D E C 10" DEC16 " C H 30" OAK30" OAK30" OAK40" CED12" FIR12" FIR12" FIR8" FIR8" FIRROW OF 3" CED ROW OF 3" CEDPROPOSED EASEMENT PROPOSED EASEMENT PROPOSED EASEMENT 318008-166223 25kVA 120/240V 318003-166294 317999-166234 25kVA 120/240V 318003-166230 25kVA 120/240V T82975 (65T) 318799-166222 UNK (65T) 317993-166244 ALLEYACTUAL LOCATION OF HAND HOLE IS UNKNOWN, NEEDS TO BE LOCATED 318999-166246 317999-166226 318975-166244 318979-166244 NEW SECONDARY HAND HOLE REQUIRED FOR CUSTOMER OWNED SERVICE CONDUCTOR POST CONSTRUCTION SITE PLAN 101121708SCALE: 1" = 20' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 9/6/19 Nate Linville (253) 970-7284 9/6/19 Nate Linville (253) 970-7284 RW-______City of Renton CITC Renton Headquarters Sch 73 Schedule 73 Conversion 1300 Bronson Way N, Renton, WA 98057 101121708 AS NOTED 3 of 5 King CSPSKEPM NE-17-23N-05E 208.080 208.082 2305E066 2305E088 2305E066SE PCR-14 CENTURYLINK N/A N/A COMCAST N/A N/A PSE GAS N/A N/A ZAYO? N/A N/A 00 1"2" 00 20'40' SITE SPECIFIC NOTES AT P01: REMOVE 318008-166223 REMOVE EXISTING 1984 40' DISTRIBUTION POLE REMOVE EXISTING 25kVA 120/240V 2B TRANSFORMER, RETURN TO PSE YARD AT P02: NEW 318003-166230 -INSTALL (1) 45' CL2 DISTRIBUTION POLE & GROUNDS 6010.1000 (PD452) -INSTALL (2) 9' 8P STD CROSS ARMS (ARD2S09) -INSTALL (2) POLE MOUNTED DEAD-ENDS (N,S) FRAME PER STD 6033.1044 (DDE2310) -INSTALL (4) ARM MOUNTED DEAD-ENDS (N,S) -INSTALL (2) POLE TOP PINS & INSULATORS -INSTALL (4) STEEL ARM PINS & INSULATORS -INSTALL (3) STIRRUPS & HOT LINE CLAMPS -INSTALL (3) 12kV AUTOMATIC DEAD-ENDS (N) 6033.1044 (DDE2310) -INSTALL (3) 12kV STRAIGHT LINE CLAMPS (S) FOR REDUCED TENSION SPAN FRAME 6033.5010 (SSD312) -INSTALL (1) LB C/O FOR TRANSFORMER ON CROSS ARM BRACKET, FUSE @ 10T, TAP AØ -INSTALL (1) FG TRI-UNIT C/O ARM W/(3) 10kV ARRESTORS -INSTALL (3) LI C/O ON NEW FG TRI-UNIT C/O ARM, FUSE @ 65T -INSTALL (3) 15kV 1/0 CS PIN TERMINATIONS -INSTALL SWITCH #T82975 -INSTALL (1) 25kVA 120/240V 1B OH TRANSFORMER PER STD 6025.1000 (TRFNXF) -INSTALL (1) 10" TRIPLE HELIX ANCHOR L=15'( -INSTALL (1) 3/8" PRIMARY DOWN-GUY L=15' -INSTALL (1) 3/8" NEUTRAL DOWN-GUY L=15' -INSTALL (1) 4" RIGID CLEVIS, NEUTRAL IN COMMON POSITION -INSTALL (1) 4" PRIMARY RISER ON NEW STANDOFF BRACKETS 6042.1000 (RIS4CSS) ±30' ____' ACTUAL -INSTALL GRID 318003-166230 AT P03: EXISTING 317999-162222 EXISTING DISTRIBUTION POLE AND EQUIPMENT TO REMAIN -INSTALL (6) ARM MOUNTED DEAD-ENDS FOR SLACK SPAN ON EXISTING ARMS (N,S) 6033.5010 (SSD312) -INSTALL (3) 12kV STRAIGHT LINE CLAMPS FOR SLACK SPAN (N) -INSTALL (3) 12kV AUTOMATIC DEAD ENDS (S) -INSTALL (1) ARM MOUNTED DEAD-END ON NEUTRAL ARM W/STRAIGHT LINE CLAMP -INSTALL (1) 3/8 PRIMARY SPAN GUY (W) TO P04 L=80' -INSTALL (1) 3/8" NEUTRAL SPAN GUY (W) TO P04 L=80' AT P04: NEW 317999-166226 -INSTALL (1) 35' CL2 GUY STUB POLE -INSTALL (1) 10" TRIPLE HELIX ANCHOR L= 10' -INSTALL (1) 3/8" SIDEWALK GUY L=10' -INSTALL GRID 317999-166266 AT P08: NEW 318999-166246 -INSTALL (1) 45' CL2 DISTRIBUTION POLE & GROUNDS 6010.1000 (PD452) -INSTALL (2) 9' 8P STD CROSS ARMS (ARD2S09) -INSTALL (2) POLE MOUNTED DEAD-ENDS (N,S) FRAME PER STD 6033.1044 (DDE2310) -INSTALL (4) ARM MOUNTED DEAD-ENDS (N,S) -INSTALL (2) POLE TOP PINS & INSULATORS -INSTALL (4) STEEL ARM PINS & INSULATORS -INSTALL (3) 12kV AUTOMATIC DEAD-ENDS (N) 6033.1044 (DDE2310) -INSTALL (3) 12kV STRAIGHT LINE CLAMPS (S) FOR SLACK SPAN TO P08 FRAME 6033.5010 (SSD312) -INSTALL (1) 10" TRIPLE HELIX ANCHOR L=15' -INSTALL (1) 3/8" PRIMARY DOWN-GUY L=15' -INSTALL (1) 3/8" NEUTRAL DOWN-GUY L=15' -INSTALL (1) 4" RIGID CLEVIS, NEUTRAL IN COMMON POSITION -INSTALL GRID 317999-166246 P09: EXISTING 318003-166294 EXISTING DISTRIBUTION POLE AND EQUIPMENT TO REMAIN -INSTALL (1) POLE-TOP PIN & INSULATOR (N) -INSTALL (1) 9' 8P STD CROSS-ARM (S) -INSTALL (2) STEEL ARM-PINS & INSULATORS -INSTALL (2) POLE MOUNTED DEAD-ENDS (N,S) -INSTALL (4) DEAD-ENDS -INSTALL (3) AUTOMATIC DEAD-ENDS (N) -INSTALL (3) STRAIGHT-LINE CLAMPS (S) FOR REDUCED TENSION SPAN TO P08 SPAN NOTE V01 TO HH1 INSTALL (1) 4" SCH 80 PVC CONDUIT ±50' ____' ACTUAL INSTALL (1) RUN 750KCMIL SECONDARY QUAD ±50' _____' ACTUAL V01 TO IP1 REMOVE EXISTING 350KCMIL QUAD SECONDARY ±90' ____' ACTUAL INSTALL (1) 4" SCH80 PVC CONDUIT ±90' _____' ACTUAL V02 TO HH2 INSTALL (1) 350KCMIL QUAD SECONDARY ±160' _____' ACTUAL SWING PRIMARY CABLE & CONDUIT TABLE Work Location Conduit Primary Cable As Built Information Size Qty Length Design Bends Pull Fwd Pull Rev Cable Length Design Cable Numbers Foreman Please Record Foreman - Complete FROM TO (in)(ft)90°45°22°11°(lbs)(lbs)Size (ft)A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) P02 J01 4"2 230'2 2 0 0 835.2 909.5 PRI 12KV 750 UG 270'EII826 EII827 EII828 J01 EM1 4"1 24'0 0 0 0 234.1 234.1 PRI 12KV 750 UG 24'EII829 EII830 EII831 J01 EM1 4"1 110'1 0 0 0 896.6 800.4 PRI 12KV 750 UG 369'EII832 EII833 EII834 SPARE J02 V01 4"1 110 0 0 0 0 108' Vault & Equipment Table Work Location Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-CompleteLBDC J01 317993 166244 5' X 7' X 6" Vault 5'x7'x6" lid w/2-3'sq doors (Mid: 7663200) (3) 15kV 200A 4POS JBUS (MID: 7625900) 9 3 V01 317979 166244 4'8" SQ X 3'6" Vault 4'8" x 5'6" x 6" Lid (Mid: 7663900, 7655200) 300kVA 120/208V PM TRF MID: 6258200 3 - V02 317979 166244 4'8" SQ X 3'6" Vault 4'8" x 5'6" x 6" Lid (Mid: 7663900, 7655200) 112.5kVA 120/208V PM TRANSFOMER (MID: 6258050) 3 - HH1 N/A 6' X 4' X 4' VLT W/2-3' SQ AS DOORS MID: 9996200 4-8POS #2-750 KCMIL SEC CON BARS MID: 7651201 MFP19006189 317967-166261 112.5kVA 120/208V 318003-166230 25kVA 120/240V T82975 (65T) 317993-166244 317970-166253 OVERHEAD MAP - BEFORE 101121708SCALE: NONE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 9/6/19 Nate Linville (253) 970-7284 9/6/19 Nate Linville (253) 970-7284 RW-______City of Renton CITC Renton Headquarters Sch 73 Schedule 73 Conversion 1300 Bronson Way N, Renton, WA 98057 101121708 AS NOTED 4 of 5 King CSPSKEPM NE-17-23N-05E 208.080 208.082 2305E066 2305E088 2305E066SE PCR-14 CENTURYLINK N/A N/A COMCAST N/A N/A PSE GAS N/A N/A ZAYO? N/A N/A 00 1"2" 00 20'40' OVERHEAD MAP - AFTER SCALE: NONE UNDERGROUND MAP - BEFORE SCALE: NONE UNDERGROUND MAP - AFTER SCALE: NONE TOP VIEW 6'MIN VAULT LID 3'MIN 3'MIN 3'MIN ROAD SIDE (PREFERRED) FIELD SIDE (PREFERRED) TOP VIEW VAULT LID AT J01 6775.0035.02Not to scale Filter fabric skirt secured with grate. Overflow Catch Basin Grate Collected Sediment NOTE: Filter fabric installed in grate is not an approved alternative. ÌÌÌÌ ÌÌÌÌ Filter fabric walls for dewatering sediment. Catch Basin Insert MID 9995728 CATCH BASIN INSERT DETAIL SCALE: NONE 0150.3200 6" to 12" Under Normal Conditions 65" Min for Triple Helix DETAIL FOR TRIPLE HELIX INSTALLATION Not To Scale ANCHOR DETAIL - TRIPLE HELIX UTILITY POLE EROSION CONTROL DETAIL TOP VIEW FLOWING DITCH or BODY OF WATER SLOPE Secure bottom of fence with gravel bags Place straw mulch on disturbed areaExcavated or Augered Hole Pole SLOPE Not to scale Adjacent to flowing ditches or bodies of water Install silt fence around pole excavation FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS (MID 9995692). 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL SILT FENCE DETAIL Not to Scale 0150.3200 Phone & TV Primary Power Cable Direct Buried or in PSE provided Excavated Dirt Pile Final Grade 24" Min 48" Max 18" Backfill for DB 120 Conduit/Direct Buried Cable 12" Min Separation 6" or 12" of sand, 5/8" minus 3" of sand, 5/8" minus, or clean backfill bedding JOINT TRENCH DETAIL 36" Min Cover ROADSIDE Typical To Excavated Dirt Pile (No Rocks over 10" Diameter) or clean backfill shading DB120 Grade Conduit Primary-Direct Buried or DB 120 (NTS) - A 6" layer of sand, 5/8" minus, or clean shading is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand, 5/8" minus, or clean shading is required when excavated native material contains rocks up to 10" in diameter. Cables should enter the vault so that all of the cables will lay in the same direction. TOP VIEW J- BOX CABLE ENTRY DETAIL Not to scale MFP19006189 101121708UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 9/6/19 Nate Linville (253) 970-7284 9/6/19 Nate Linville (253) 970-7284 Required City of Renton CITC Renton Headquarters Sch 73 Schedule 73 Conversion 1300 Bronson Way N, Renton, WA 98057 101121708 AS NOTED 5 of 5 King CSPSKEPM NE-17-23N-05E 208.080 208.082 2305E066 2305E088 2305E066SE PCR-14 CENTURYLINK N/A N/A COMCAST N/A N/A PSE GAS N/A N/A ZAYO? N/A N/A GUARD POSTS FOR PADMOUNT EQUIP. TYPICAL TRANSFORMER 0700.1600Not to scale 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 3' MIN 8' x 8' OR 10' x 10' CONCRETE PAD GUARD POSTS ACCESS DOOR SWING 4' MIN 18' MIN 3' MIN CL CL 18' MIN TRENCH DETAIL Electric Service Cable in Conduit (NTS) Electric Service Cable in Conduit Excavated Dirt Pile Final Grade 24" Min 24" Min to 36" Max Cover 12" Typical (6" Min) Backfill for Conduit Free of rocks larger than 8" in diameter) 36" MINIMUM COVER IN RIGHT OF WAY To Excavated Dirt Pile 3" Schedule 40 Grey PVC Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris, glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter. TOP VIEW Excavation - 10-1/3 cubic yards SIDE VIEW Rock Crushed 6" 4'-4" 2" 8' 8' 4'-8" 3'-6" 4'-8" 6" 20" 4'-8"5'-6" 44" Not to scale 6045.5000-1 3,600 lbs 1,657 lbs VAULT & EXCAVATION DETAIL AT V01 & V02 CUSTOMER ENTRANCE CUSTOMER ENTRANCE CUSTOMER ENTRANCE PSE ENTRANCE COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR TRANSFORMER VAULT AT V01 & V02 CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 1.5' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA Not to scale 1.5' MIN 3' MIN THREE PHASE SECONDARY CONCRETE HANDHOLE AT HH1 Not to scale 6050.2120-13'-6"4'-0" 6'-0 " Typical customer run service conductors in duct Install PVC bellends and grout into wall Seal conduit with foamConduits and conductors shall enter from ends of handhole through knockouts provided Cover with 2 3' Sq Std Plate Door, or Cover with 2 3' Sq Anti-Skid Door Base 3450 lbs Cover 1510 lbs 6'-8 " 4'-8"6"POWE R 2" SIDE VIEW 4'-4"Crushed 6" Rock TOP VIEW 8' 10' Excavation - 13 Cubic Yards 3' 10' APPROVED TRANSFORMER AREA 3' REDUCED FLAMMABILITY TRANSFORMER CLEARANCES FROM COMBUSTIBLE SURFACES COMBUSTIBLE BUILDING WALLS AND ROOFMFP19006189 GARDEN AVE NN 2ND AVE GARDEN AVE N1919 1919 15151515N 2ND ST GARDEN AVE NP07 P14 1 1 1 2 1 2 1 2 1 2 RIGHTKEEPR4-7BM6-2R9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9DETOURM4-9bR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bROADWORKAHEADW20-1350'X'W1-4LUSE MAXIMUM AVAILABLE SPACE FOR SIGNS R O A D W O R K A H E A D W20-1350'maintain (2) 12' lanesROADWORKAHEADW20-1W1-4R100'100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1 100' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999 INFRASOURCE LLC 000 00000 00 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGN PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 1 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY MFP19006189 GARDEN AVE NN 2ND AVE GARDEN AVE N1919 1919 15151515GARDEN AVE NP05 P12 1 1 1 2 1 2 1 2 1 2 STOP FLAGGER STOP FLAGGER STOP FLAGGER STOP FLAGGER PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 000 0000 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGW20-7AW20-4ONE LANEROADAHEAD100'100'ROADWORKAHEADW20-1350' R O A DWO R K A H E A D W20-1350'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9bR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bS/WCLOSED R9-9FLAGGERS WILL ASSIST PEDESTRIAN AROUND WORK ZONE N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 2 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP19006189 GARDEN AVE NN 2ND AVE 1919 1919 15151515N 2ND ST GARDEN AVE NP06 P13 1 1 1 2 1 2 1 2 1 2 RIGHTKEEPR4-7BM6-2maintain (2) 12' lanesPLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0 000000 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGR9-11SIDEWALK CLOSED AHEAD DETOUR M4-9bR9-11SIDEWALKCLOSEDAHEADDETOURM4-9bROADWORKAHEADW20-1350'100'W1-4LR O A DWO R K A H E A D W20-1350'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1 100'W1-4R100'S/W CLOSED R9-9S/WCLOSEDR9-9N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 3 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY MFP19006189 MEADOW AVE NN 2ND AVEGARDEN AVE N1919191915151515N 2ND STGARDEN AVE N15151717N 2ND AVEMEADOW AVE NP04STOPFLAGGER STOPFLAGGER W20-7AROAD WORK AHEAD W20-1BEPREPARED TOSTOP W3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'STOPFLAGGER W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100' W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'STOPFLAGGER ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1100'R9-11SIDEWALKCLOSEDAHEADDETOURM4-9b R9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9FLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONEPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROM TO TOW AWAY AREA PHONE 888-9999INFRASOURCE LLC 000 0000000 NO PARKING NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB1011217081300 Bronson Ave N, Renton, WA 9805711/12/2019safaa.neema@pse.com(425) 398-6077SHEET 4 of 11CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.PRINT ON11X17" SHEETS ONLY28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP19006189 MEADOW AVE NN 2ND AVEGARDEN AVE N1919191915151515 GARDEN AVE N15151717N 2ND AVEMEADOW AVE NP03P02P01STOPFLAGGER STOP FLAGGERSTOPFLAGGER STO P FLAGGER PLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKINGFLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONEW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'W20-7AROAD WORK AHEAD W20-1BEPREPAREDTO STOP W3-4100'100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100' R9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9S/W CLOSED R9-9R9-11SIDEWALK CLOSED AHEAD NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB1011217081300 Bronson Ave N, Renton, WA 9805711/12/2019safaa.neema@pse.com(425) 398-6077SHEET 5 of 11CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.PRINT ON11X17" SHEETS ONLYTRENCH28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP19006189 MEADOW AVE NN 2ND AVEGARDEN AVE N1919191915151515N 2ND STGARDEN AVE N15151717N 2ND AVEMEADOW AVE NJ01STOPFLAGGERSTOPFLAGGER STOPFLAGGER W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'STOP FLAGGER W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'X'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'USE MAXIMUM AVAILABLESPACE FOR SIGNSS/WCLOSEDR9-9 R9-11SIDEWALK CLOSED AHEAD DETOURM4-9bS/WCLOSEDR9-9R11-4R5-133ROAD CLOSEDTOTHRU TRAFFICLOCALACCESSONLYBRONSON WAY NPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROM TO TOW AWAY AREA PHONE 888-9999INFRASOURCE LLC 000 0000000 NO PARKINGFLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONENPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB1011217081300 Bronson Ave N, Renton, WA 9805711/12/2019safaa.neema@pse.com(425) 398-6077SHEET 6 of 11CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604055 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.PRINT ON11X17" SHEETS ONLYTRENCH28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP19006189 BRONSON WAY N MEADOW AVE NN 2ND AVE 1919 1919 15151515GARDEN AVE N15151717 N 2ND AVEMEADOW AVE NJ01 V01 V02 HH1 1112121212STREETCLOSED BARRICADE R11-2STREETCLOSEDBARRICADER11-2R11-4R5-133 ROAD CLOSEDTOTHRU TRAFFIC LOCAL ACCESSONLY ALLEYCLOSEDAHEADALLEY-CLOSED-AHDAL LEYCLOSEDAHEADALLEY-CLOSED-AHD ALLEYCLOSEDAHEADALLEY-CLOSED-AH D ALLEYCLOSEDAHEADALLEY-CLOSED-AHD BUSINESS/ RESIDENT WILL BE INFORMED OF ALLEY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 7 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND TRENCH SIGN LOCATION TRAFFIC FLOW 28" TRAFFIC CONE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY MFP19006189 RRRRRR12121212121717 BRONSON WAY NMEADOW AVE N151515151717 N 2ND AVEMEADOW AVE NFACTORY AVE NFACTORY AVE NP08 P09 1717 1112 1212 12 STOP FLAGGER STOP FLAGGER STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROAD WORKAHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROAD WORK AHEAD W20-1BEPREPAREDTOSTOPW3-4100'100'100' W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'ROADWORKAHEADW20-1350'ROADWORKAHEADW20-1 350'ROADWORKAHEADW20-1100'PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888 -9999INFRASOURC E L LC 0 00 0 00000 0 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGR9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9 S/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADFLAGGERS WILL ASSIST PEDESTRIAN AROUND WORK ZONE N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 8 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP19006189 RRRRRR12121212121717BRONSON WAY NMEADOW AVE NN 2ND AVEGARDEN AVE N1919191915151515N 2ND STGARDEN AVE N15151717N 2ND AVEMEADOW AVE NFACTORY AVE NFACTORY AVE NEM1P1017171112121212STOP FLAGGER STO P FLAGGER STOP FLAGGERSTOP FLAGGER W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1 BE PREPAREDTO STOP W3-4100'100'100'ROADWORKAHEADW20-1100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1100' W20-7A W20-4ONE LANEROADAHEAD100'100'ROAD WORK AHEAD W20-1350'ROADWORKAHEADW20-1350'R9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9S/WCLOSEDR9-9 R9-11SIDEWALKCLOSEDAHEADFLAGGERS WILL ASSISTPEDESTRIAN AROUNDWORK ZONEPLACE SIGNSBOTH SIDES OFWORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NPuget Sound EnergyTraffic Control Supervisor:Stephen R GadkeCard No. 010741Exp.5/31/2021stephen.gadke@pse.com(425) 424-6431TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB1011217081300 Bronson Ave N, Renton, WA 9805711/12/2019safaa.neema@pse.com(425) 398-6077SHEET 9 of 11Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.PRINT ON11X17" SHEETS ONLY28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYCHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840SIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'MFP19006189 RRRRRR12121212121717 BRONSON WAY NMEADOW AVE NN 2ND AVE 151515151717 N 2ND AVEMEADOW AVE NP11 1717 1112121212STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350' W20-7AROADWORKAHEAD W20-1 BEPREPAREDTOSTOPW3-4 350' 350'350' S/W CLOSEDR9-9R9-11SIDEWALK CLOSED AHEADS/WCLOSEDR9-9R9-11SIDEWALKCLOSEDAHEADFLAGGERS WILL ASSIST PEDESTRIAN AROUND WORK ZONE PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 00 0 000 0000 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGX'X'PLACE W20-1 SIGNS ON ALL ADJACENT STREETS WITHIN FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1350 N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 10 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP19006189 RRRRRR12121212121717 BRONSON WAY NMEADOW AVE NN 2ND AVE 151515151717 N 2ND AVEMEADOW AVE NHH2 1717 1112121212 STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350' W20-7AROADWORKAHEAD W20-1 BEPREPAREDTOSTOPW3-4 350' 350'350'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100' FLAGGERS WILL ASSIST PEDESTRIAN AROUND WORK ZONE PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 0 00 0 00000 0 NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGS/W CLOSED R9-9S/WCLOSEDR9-9R9-11SIDEWALK CLOSED AHEAD R9-11SIDEWALKCLOSEDAHEADX'X'PLACE W20-1 SIGNS ON ALL ADJACENT STREETS WITHIN FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1350 N PSE PUGETSOUNDENERGY JOB101121708 1300 Bronson Ave N, Renton, WA 98057 11/12/2019 safaa.neema@pse.com (425) 398-6077 SHEET 11 of 11 Puget Sound Energy Traffic Control Supervisor: Stephen R Gadke Card No. 010741 Exp.5/31/2021 stephen.gadke@pse.com (425) 424-6431 TEMPORARY TRAFFIC CONTROL PLAN CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 55 + 60/65 45/55 35/40 30 25 SIGN SPACING "X" 800 500' 350' 200' 100' MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PRINT ON 11X17" SHEETS ONLY 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP19006189