HomeMy WebLinkAboutF_APPROVED_Water_Revision_C4.1_20191211.pdf0+001+002+003+004+005+00T STA:3+94.83, 0.00'T 1-10"x6" TEE (FLXFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLXMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:3+68.60, 0.00'T 1-45° BEND 1-CONC. THRUST BLOCK STA:3+80.65, 0.00'RT 1-45° BEND 1-CONC. THRUST BLOCK STA:7+20.29, 0.00'RT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:7+36.14, 0.00'T 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:7+12.31, 0.00'T 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK WALKER MAZDA DEALERSHIP REFER TO WATER PROFILE 1 REFER TO WATER PROFILE 2 REFER TO WATER PROFILE 3 N1° 50' 05"E500.00'0+00 1+00 2+00 3+00 4+005+006+007+008+009+0010+0011+0011+28 3 C4.2 6" DDCVA 3 C4.2 STA:3+74.63, 0.00'LT 1-10"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THURST BLOCK 1" IRRIGATION METER 1" DCVA 3" RPBA TO BE INSTALLED INSIDE FIRE SPRINKLER RISER ROOM PER PLUMBING PLANS STA:10+09.88, 129.60'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:10+87.29, 52.19'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK 105 LF 2" PRIVATE WATER SERVICE PIPE STA:3+74.63, 35.55'RT 1-45° BEND 1-CONC. THRUST BLOCK STA:0+13.31, 0.00'LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STA:1+14.64, 0.00'LT 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:1+14.63, 21.64'LT CENTER FIRE HYDRANT ASSEMBLY STA:3+94.94, 25.44'RT CENTER FIRE HYDRANT ASSEMBLY STA:7+12.31, 27.04'RT CENTER FIRE HYDRANT ASSEMBLY STA:10+64.42, 0.02'RT 1-10"X6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1- FIRE HYDRANT ASSEMBLY 1-CONC THRUST BLOCK STA:10+64.42, 30.37'LT CENTER FIRE HYDRANT ASSEMLBY STA:10+31.50, 40.06'LT 1-FDC (FL) STA:0+00.00 N:166811.9796 E:1297757.2602 STA:4+99.97 N:167311.6912 E:1297773.2683 STA:3+51.78, 29.03'RT ABANDON AND CAP EXISTING 34" WATER SERVICE. (BY CITY FORCES) STA:11+22.47, 0.00'LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STA:7+48.54, 448.68'LT 1-10" CAP (MJ) 1- 2" TEMPORARY BLOW OFF ASSEMBLY PER STD PLAN NO.340.20 1- CONC. THRUST BLOCK CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 EAST VALLEY ROADMATCH LINE WATER MAIN STA: 5+50.00 MATCH LINE WATER MAIN STA: 11+00.00 1 C4.5 NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) ELEV:230.75 VERTICAL DATUM NAD 1983 WASHINGTON STATE PLANE NORTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) BASIS OF BEARING WATER PLAN C4.1 20 PROVIDE PAVEMENT PATCH AS REQUIRED PER CITY OF RENTON STD. PLAN 110 PROVIDE PAVEMENT PATCH AS REQUIRED PER CITY OF RENTON STD. PLAN 110 15.00' EASEMENT 15.00' EASEMENT 21.50' EASEMENT 3 C5.3 2 C4.2 2 C4.2 2 C4.2 3 C5.3 1 C4.3 1 C4.4 1 C4.5 REFER TO FIRE SYSTEM PLAN 1 C4.2 W-406701WTR-40-4067ADJUST EXISTING HYDRANT TO FINISH GRADE OF NEW 8 FT PLANTER STRIP. INSTALL NEW HYDRANT IF HYDRANT RELOCATION IS REQUIRED TO CLEAR NEW SIDEWALK. ADJUST EXISTING HYDRANT TO FINISH GRADE OF NEW 8 FT PLANTER STRIP. INSTALL NEW HYDRANT IF HYDRANT RELOCATION IS REQUIRED TO CLEAR NEW SIDEWALK. 1 C4.7 2 C4.5 2" DOMESTIC WATER METER 3 C4.5 2 C4.6 2 C4.6 ENVIRONMENTAL NOTES BILL KANE WITH ECO COMPLIANCE CORPORATION SHALL BE AVAILABLE DURING ONSITE WATER LINE EXCAVATIONS TO ENSURE THE TRENCH IS FREE FROM CONTAMINATED SOILS. ANY CONTAMINATION THAT EXCEEDS CLEAN-UP LEVELS SHALL BE REMOVED AND HAULED TO AN APPROVED OFFSITE DISPOSAL FACILITY. SOILS SHALL BE REPLACED WITH CLEAN BEDDING AND BACKFILL FOR WATER LINE TRENCHES. CLEAN BACKFILL MATERIALS FROM AN APPROVED SOURCE SHALL BE USED FOR ALL TRENCH BACKFILL AROUND WATERMAINS. WHERE WATER MAIN UTILITY EXCAVATIONS EXTEND BELOW THE EXISTING FILTER FABRIC LAYER SEPARATING STRUCTURAL FILL FROM NATIVE SOILS A NEW FILTER FABRIC SHALL BE LAID ALONG THE TRENCH BOTTOM AND SIDES PRIOR TO PLACEMENT OF BEDDING AND BACKFILL MATERIAL. BILL KANE CONTACT: 206-715-1396 BILL@ECOCOMPLIANCE.BIZ 12/06/2019 valve shall be shifted to the north side of fitting. WATER UTILITY agafour 12/11/2019 DEVELOPMENT ENGINEERING bbannwarth 12/11/2019