Loading...
HomeMy WebLinkAboutC_Construction Drawings_191216_v1.pdfCAR WORKS ADD TO RENTON LOTS 11,12, 13 TGW PORTION OF LOT 14 LY NLY OF A LINE DAF - BEGIN NE CORNER OF LOT 14 TH S 18 FT TO BEGINNING OF LINE TH S 89-49-20 W 73 FT TH S 00-18-00 W 6 FT TH S 82-14-50 W 30.30 FT TO W LINE OF LOT 14 TO TERMINUS OF SAID LINE PLAT BLOCK: 1 PLAT LOT: 11-12-13-14 LEGAL DESCRIPTION APPROVED BY CONSTRUCTION MANAGER DATE SIGNATURE PROJECT MANAGER SITE ACQUISITION ZONING APPROVAL / SIGN OFF PROJECT CONTACT LIST PROJECT INFORMATION UTILITY COMPANIES THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. PROPRIETARY INFORMATION RF LDC, INC. CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 EMAIL: rhall@ldccorp.com PROJECT ARCHITECT: APPLICANT:PROPERTY OWNER: REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED FROM VERIZON WIRELESS OFFICE: x GET ON I-90 W FROM SE EASTGATE WAY x HEAD EAST TOWARD 158TH AVE SE x TURN RIGHT ONTO 158TH AVE SE x TURN RIGHT ONTO SE EASTGATE WAY x TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE x KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE ONTO I-90 W x TAKE I-405 S TO WA-900/SUNSET BLVD N IN RENTON. TAKE EXIT 4 FROM I-405 S x MERGE ONTO I-90 W x TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON x MERGE ONTO I-405 S x TAKE EXIT 4 FOR WA-900 W TOWARD WA-169 S/RENTON/ENUMCLAW x CONTINUE ON WA-900/SUNSET BLVD N. DRIVE TO BRONSON WAY N x MERGE ONTO WA-900/SUNSET BLVD N x TURN RIGHT ONTO BRONSON WAY N x TURN LEFT ONTO MEADOWS AVE N x DESTINATION WILL BE ON THE LEFT DRIVING DIRECTIONS VERIZON WIRELESS 3245 158TH AVENUE SE BELLEVUE, WA 98008 VERIZON WIRELESS PROPOSES TO INSTALL A TEMPORARY CELL ON WHEELS (COW) TELECOMMUNICATIONS FACILITY WITH PANEL ANTENNAS, MICROWAVE, AND A TEMPORARY GENERATOR WITHIN A TEMPORARY FENCED COMPOUND. MICROWAVE (ON SITE) TELEPHONE:POWER: PUGET SOUND ENERGY PHONE: (888) 225-5773 ZONING CLASSIFICATION: CODE INFORMATION: CA (COMMERCIAL ARTERIAL) BUILDING CODE:IBC 2015 CONSTRUCTION TYPE:IIB OCCUPANCY:U, S-2 JURISDICTION:CITY OF RENTON PROPOSED BUILDING USE: UNMANNED TELECOM LATITUDE: SITE LOCATION (NAD83): 47° 29' 03.77" N LONGITUDE:122° 11' 58.24" W TOP OF STRUCTURE:86.00'± AMSL BASE OF STRUCTURE:41.00'± AMSL TBD PROJECT LEASE AREA: 1352300060 PARCEL NUMBER: 0.33 ACRES AREA OF PARCEL: N/A NEW IMPERVIOUS AREA: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS UNAFFECTED. GENERAL INFORMATION: PROJECT DESCRIPTION: 45.0' AGL 0.0' AGL (47.484381° N) (122.199511° W) VICINITY MAP NOT TO SCALE GENERAL LOCATION MAP NOT TO SCALE PROJECT PROJECT BRYANT MOTORS INC. 1300 BRONSON WAY N RENTON, WA 98055 CONTACT: KEN BRYANT PHONE: (425) 255-3478 TITLE SHEET T-1.0 LANDLORD 1300 BRONSON WAY N RENTON, WA 98055 SEA CEDAR RIVER COW DRAWING INDEX DWG NO.DESCRIPTION T-1.0 TITLE SHEET A-1.0 SITE PLAN A-2.0 ENLARGED SITE PLAN A-3.0 ELEVATIONS DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING. CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL RESPONSIBILITY FOR MOUNTING PRODUCTS USED & THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. DISCLAIMERS SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV SEA CEDAR RIVER COW 1300 BRONSON WAY N RENTON, WA 98055 6-28-17 RJG RBH 1 6-28-17 PRELIMINARY ZONING RJG 2 7-10-17 FINAL ZONING ENS 3 8-23-17 FINAL ZONING RJG 4 10-18-17 RFZD: RELOCATE COMPOUND RJG APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 LDC, INC. CONTACT: RICK CARDOZA PHONE: (253) 218-9017 EMAIL: rcardoza@ldccorp.com PROJECT ARCHITECT: RECEIVED 06/26/2018 amorganroth PLANNING DIVISION 06/13/2018 1 1 ZONING: ADJACENT ZONING: ZONING MAP NOT TO SCALE PROPOSED QUANTITIES POWER LENGTH: ±18' FIBER/TELCO LENGTH:N/A ROAD LENGTH:N/A UNDERGROUND: OVERHEAD:±18' SITE PLAN 22"x34" SCALE: 1" = 20'11"x17" SCALE: 1" = 40' PROJECT CA PROPOSED VERIZON WIRELESS ANTENNAS AND MICROWAVE MOUNTED ON CELL ON WHEELS (COW) WITHIN A TEMPORARY FENCED COMPOUND EXISTING SITE ACCESS SITE PLAN A-1.0 CA (COMMERCIAL ARTERIAL) R-10 (RESIDENTIAL 10 DU/AC) SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV SEA CEDAR RIVER COW 1300 BRONSON WAY N RENTON, WA 98055 6-28-17 RJG RBH 1 6-28-17 PRELIMINARY ZONING RJG 2 7-10-17 FINAL ZONING ENS 3 8-23-17 FINAL ZONING RJG 4 10-18-17 RFZD: RELOCATE COMPOUND RJG APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 CA CA CA CA CA ADJACENT ZONING: CA (COMMERCIAL ARTERIAL) ADJACENT ZONING: CA (COMMERCIAL ARTERIAL)ADJACENT ZONING: CA (COMMERCIAL ARTERIAL) ADJACENT ZONING: CA (COMMERCIAL ARTERIAL) R10R10R10 114'±TOWERSETBACK21'± TOWER SETBACK 79'± TOWER SETBACK 24'± TOWER SETBACK 1 1 GUYING OF COW MAY NOT BE REQUIRED ENLARGED SITE PLAN 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" EXISTING SITE ACCESS SECTOR3:290°SECTOR1:40°SECTOR2:165°ENLARGED SITE PLAN A-2.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV SEA CEDAR RIVER COW 1300 BRONSON WAY N RENTON, WA 98055 6-28-17 RJG RBH 1 6-28-17 PRELIMINARY ZONING RJG 2 7-10-17 FINAL ZONING ENS 3 8-23-17 FINAL ZONING RJG 4 10-18-17 RFZD: RELOCATE COMPOUND RJG APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 CONSTRUCTION PLAN KEYED NOTES 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. SITE NOTES PROPOSED POWER ROUTING. PROPOSED VERIZON WIRELESS TEMPORARY 6'-0" HIGH CHAIN LINK FENCE. PROPOSED VERIZON WIRELESS TEMPORARY CHAIN LINK ACCESS GATE WITH LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE. PROPOSED VERIZON WIRELESS ANTENNA MOUNT. PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS DIPLEXER (TYP 2 PER SECTOR, 6 TOTAL). PROPOSED VERIZON WIRELESS MICROWAVE (1 TOTAL). PROPOSED VERIZON WIRELESS RRUS B5 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX (2 TOTAL @ EQUIPMENT). PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14'). ENGINEERED BY OTHERS. PROPOSED VERIZON WIRELESS TEMPORARY GENERATOR (1 TOTAL). PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER BASE AND DISCONNECT. PROPOSED VERIZON WIRELESS EQUIPMENT CABINET. PROPOSED VERIZON WIRELESS RRUS 32 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RRUS B13 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED 5' WIDE LANDSCAPING BUFFER. 3 4 5 6 7 9 10 11 12 13 21 24 25 28 29 32PROPOSEDVERIZONWIRELESS30'-0"TEMPORARYFENCEDCOMPOUNDPROPOSED VERIZON WIRELESS 35'-0" TEMPORARY FENCED COMPOUND MEADOWSAVEN14'-0"PROPOSED 10'-0" TEMPORARY ACCESS GATE 11'-0"9'-6"6'-6"PROPOSEDVERIZONWIRELESS14'-0"CELLONWHEELSPROPOSED VERIZON WIRELESS 6'-0" CELL ON WHEELS EXISTING PSE UTILITY POLE (TO REMAIN)44 10 99 21 25 PROPOSED VERIZON WIRELESS TEMPORARY UTILITY POLE PROPOSED TEMP ECOLOGY BLOCK, TYP PROPOSED VERIZON WIRELESS TEMPORARY GUY WIRE, TYP 28 11 6 EXISTING LANDSCAPING (TO REMAIN) 16'-4"MW:TBD12 29 13 PROPOSED COW OUTRIGGER, TYP EXISTING PARKING LOT TOOL BOX7 5 3 24 32 32 (BELOW) 1PROPOSED SOUTH ELEVATION (LOOKING NORTH) 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" TIP HEIGHT OF PROPOSED VERIZON WIRELESS ANTENNAS 40.0' AGL FINISH GRADE 0.0' AGL ELEVATIONS A-3.0 CONSTRUCTION PLAN KEYED NOTES 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. SITE NOTES PROPOSED POWER ROUTING. PROPOSED VERIZON WIRELESS TEMPORARY 6'-0" HIGH CHAIN LINK FENCE. PROPOSED VERIZON WIRELESS ANTENNA MOUNT. PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS DIPLEXER (TYP 2 PER SECTOR, 6 TOTAL). PROPOSED VERIZON WIRELESS MICROWAVE (1 TOTAL). PROPOSED VERIZON WIRELESS RRUS B5 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX (2 TOTAL @ EQUIPMENT). PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14'). ENGINEERED BY OTHERS. PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER BASE AND DISCONNECT. PROPOSED VERIZON WIRELESS RRUS 32 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RRUS B13 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED 5' WIDE LANDSCAPING BUFFER. 3 4 5 6 7 9 11 12 13 21 25 29 32 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV SEA CEDAR RIVER COW 1300 BRONSON WAY N RENTON, WA 98055 6-28-17 RJG RBH 1 6-28-17 PRELIMINARY ZONING RJG 2 7-10-17 FINAL ZONING ENS 3 8-23-17 FINAL ZONING RJG 4 10-18-17 RFZD: RELOCATE COMPOUND RJG APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 PROPOSED VERIZON WIRELESS 30'-0" TEMPORARY FENCED COMPOUND PROPOSED VERIZON WIRELESS 6'-0" CELL ON WHEELS 12 6 7 PROPOSED VERIZON WIRELESS TEMPORARY UTILITY POLE PROPOSED TEMP ECOLOGY BLOCK, TYP (BEYOND) PROPOSED VERIZON WIRELESS TEMPORARY GUY WIRE, TYP EXISTING PSE UTILITY POLE (TO REMAIN) EXISTING LANDSCAPING (TO REMAIN) 4 9 25 PROPOSED VERIZON WIRELESS TEMPORARY OVERHEAD POWER SERVICE ORIGINATING FROM EXISTING PSE UTILITY POLE 29 3 13 RAD CENTER OF PROPOSED VERIZON WIRELESS MICROWAVE 39.0' AGL 5 11(BEYOND) 32 21 HEIGHT OF PROPOSED LANDSCAPE BUFFER 10.0' AGL