Description:Relocate 2035' of gas pipe for City project. T&T 5 existing services over to new main. Restoration per City of Renton
standards.
APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
C: (425) 892-0416Applicant
Stuart Bennett
Infrasource Services LLC
14103 Stewart Rd
Sumner, WA 98490
B: (303) 419-8755
H: (425) 677-5197
C: (713) 985-6489
Contractor
Business License Number: 36742Construction Contractor: INFRASL871C2
VO TRUNG VAN 4650 NE 10TH ST
RENTON , WA 98059
Owner
Marita Bond
Puget Sound Energy Billing
6905 S 228 St
Kent, WA 98032
B: (253) 395-6346Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
տ New Construction տ Repair/Relocate տ Underground տ Overhead տ Sidewalk տ Street
տ Open Trench տ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Puget Sound Energy - Gas
109102802
CORRIE RYDBERG
(253) 234-6410
CORRIE.RYDBERG@PSE.COM
4650 NE 10TH ST
RELOCATE 2035' OF GAS PIPE FOR CITY PROJECT - T&T 5 EXISTING SERVICES OVER TO NEW MAIN
1 POTHOLE EXCAVATION OVER EXISTING GAS MAIN ON E. SIDE OF DUVALL BETWEEN NE 8TH & NE 7TH.
PLEASE SEE ATTACHED.
✔✔✔✔
✔✔2035'L x 2'W x 42"D
Infrasource (253) 234-6410
INFRASL871C2 BL036742
Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2019.12.09 20:21:27 -08'00'12/09/19
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR
DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
•Comply with all traffic regulations of the City of Renton and the State of Washington.
•Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
•Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
•By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Reset FormPrint Form
109102802
Infrasource
GLENN HELTON (425) 559-4647
6905 S 228th St, Kent, WA 98032
GLENN.HELTON@PSE.COM
4650 NE 10TH ST
TBD
TBD
CORRIE RYDBERG
12/09/19
Corrie Rydberg Digitally signed by Corrie Rydberg
Date: 2019.12.09 20:21:44 -08'00'
SKETCH
I
-- NORTH --
I
NOTES:
•Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
•The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
•Approved Temporary Traffic Control Plan must be at the work site during work hours.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
•Total road closure lasting more than 24 hours is subject to the approval by the City Council.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
•The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
1111111111
11111111
17171515
1212131
2
1
2DUVALL AVE NENE 7TH PL
DUVA
L
L
P
L
N
ECHELAN PL NENE 8TH ST
11111111
ARRW-BRD
ROAD
WORK
AHEAD W20-1350'350'350'RIGHT LANE
CLOSED
AHEAD W20-5RW4-2LW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
POTHOLE PROJECT TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 1 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
1212121212
12 1111 11
111111121212121211111111
11 11
11111212NE Sunset
B
l
v
d
DUVALL AVE NEDUVALL AVE NEW12-1BIKESMERGE WITHTRAFFICW4-1BBIKELANEENDSW9-1BCENTER LANECLOSEDAHEADW9-3ROADWORKAHEADW20-1THRUTRAFFICMERGELEFTW4-7L350'350'350'W20-1ROADWORKAHEADW20-1ROADWORKAHEAD
CENTER LANECLOSEDAHEAD W9-3ROADWORKAHEAD W20-1W4-2R350'350'350'RIGHTKEEPR4-7BRIGHT
KEEP
R4-7B LEFTKEEPR4-8BBUSSTOPSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 2 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
111111111212121212
NE 12TH ST
12 1212121111111111 11
111112
12
NE Sunse
t
B
l
v
d
14 14 14 14
DUVALL AVE NEDUVALL AVE NEDUVALL AVE NEONLYR3-5RLEFTKEEPR4-8BRESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE ROADWORKAHEADW20-1350'350'350'RIGHT LANECLOSEDAHEADW20-5RW4-2LCENTER LANECLOSEDAHEAD W9-3ROAD
WORKAHEAD W20-1350'350'W20-1ROADWORKAHEADW20-1ROADWORKAHEAD 12 12 12 12
12 12 12 12
11 11 11 11 11
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 3 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
12 12 12 121111 11111212121212
NE 12TH ST
14 14 14 14
DUVALL AVE NEDUVALL AVE NEARRW-BRD
ARRW-BRDROADWORKAHEADW20-1W20-7A350'350'350'RIGHTTWO LANESCLOSEDAHEADW20-5RONLYR3-5RPOLICEUPO
STOP
FLAGGER
STOP
FLAGGER
50' MIN W20-7AW20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'
ROAD
WORKAHEAD W20-1W20-7ALEFT LANE
CLOSEDAHEAD W20-5L350'350'350'ARRW-BRD RIGHTKEEPR4-7BCONETOPPERR9-3C/WCLOSEDR9-3
C/WCLOSEDDETOURM4-9bDETOURM4-9b
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 4 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
12 12 12 121111 11111212121212
NE 12TH ST
14 14 14 14DUVALL AVE NEARRW-BRDARRW-BRDROADWORK AHEADW20-1W20-7A350'350'350'RIGHTTWO LANESCLOSEDAHEADW20-5RONLYR3-5RCONETOPPER
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
STOP
FLAGGER
STOP
FLAGGER
POLICEUPO
CONETOPPERRIGHTKEEPR4-7BARRW-BRD
ROADWORKAHEAD W20-1W20-7ALEFT LANECLOSED
AHEAD W20-5L350'350'350'W20-7AROADWORKAHEADW20-1
W20-4ONE LANEROADAHEAD100'100'100'W20-7ASIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 5 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
111111111212121212
NE 12TH ST
14 14 14 14
DUVALL AVE NEDUVALL AVE NEARRW-BRD
LEFTKEEPR4-8BROADWORKAHEADW20-1350'350'350'RIGHT LANECLOSEDAHEADW20-5RW4-2LW20-1ROADWORKAHEAD W20-1ROADWORKAHEADRESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
141416164650
16 16
7712 12 12 12
12 12 12 12
NE 10TH ST DUVALL PL NEDUVALL AVE NEARRW-BRDRIGHTKEEPR4-7BROAD
WORK
AHEAD W20-1350'350'350'W4-2RLEFT LANE
CLOSEDAHEAD W20-5LW20-1ROADWORKAHEADW20-1ROADWORKAHEADCREW WILL TRENCH APROX.
250' PER DAY, CREW TO MOVE
CONES AND SIGNS SOUTH AS
WORK PROGRESSES SOUTH.
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 6 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
788
1414161616 16
7712 12 12 12
12 12 12 12
NE 10TH ST DUVALL PL NEDUVALL AVE NER9-3C/WCLOSEDR9-3
C/WCLOSEDDETOURM4-9bDETOURM4-9b
STOP
FLAGGER
STOP
FLAGGER
POLICEUPO
RIGHTKEEPR4-7BARRW-BRD
12 12 12 12 ROAD
WORK
AHEAD W20-1W20-7ALEFT LANECLOSEDAHEAD W20-5L350'350'350'ROADWORKAHEADW20-1W20-7A350'350'350'RIGHTTWO LANESCLOSEDAHEADW20-5RARRW-BRD
LEFTKEEPR4-8BW20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'X'W20-1ROADWORKAHEADW20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
LEGEND
TRENCH
28" TRAFFIC CONE
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
CHEVRONARROW BOARD
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB109102802
4650 NE 10TH ST, RENTON, WA 98059
12/03/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 7 of 7
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
8. Work area will be along Duvall Ave NE between NE
Sunset Blvd and NE 10th St.
N
905+00906+00907+00908+00909+00910+00911+00912+00913+00914+00915+00916+00917+00918+00919+00920+00921+00922+00923+00924+00925+00926+00927+00928+00929+00929+71889+00890+00891+00892+00893+00894+00895+00896+00897+00898+00899+00900+00901+00902+00903+00904+00N
Vicinity Map
Owner / Developer Contact Info
officeATTN:
PSE
N/A
N/A
PSE N/A
Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: InfraSource Construction Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
4680 06/11
11286858 109102802
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
GAS
PROJECT PHASE Notification #Order #
Retirement
Relocate
SAP Superior
Service/Meter
Service/Meter
HP Svc/MSA
Dis. Reg. / FT
Ind. MSA
Ind. Service
Service/Meter
Service/Meter
SYSTEM MAOP DENOTED BY: SYSTEM MAOP = ___ PSIG
BOX (TEST LEAD) INSTALLATION.
THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS
TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS
SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE.
RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION.
MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400.
PURGE POINTS AND PRESSURE TAPS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3300, AND 2525.1200.
ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY
COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE
INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY
THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED
PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE.
DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT
PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND
NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS
EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY
ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES.
TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811
FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO
STANDARD GAS CONSTRUCTION NOTES:
14.
13.
15.
10.
11.
THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE.
9.
6.
7.
5.
4.
3.
1.
60
16. IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH.
-----------------
NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS).2.
8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS
OPERATING STANDARD 2525.2500.
NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX.
GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED.12.
___________________________, PHONE______________.
NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES17.
FOOTAGE BETWEEN FITTINGS.
18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL
INFORMATION ON D-4 CARD)
SITE PLAN
SCALE: 1" = 50'-0" 109102802DESIGNED BY PUGET SOUND ENERGY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
Drawing Number
SAP Sup Order Nbr
M. HAACK 206.795.5834
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
"Locates Required"
"Flagging Required"
Yes No
Yes No
Cell Phone:
Project Manager Contact Information:
E-Mail:
Name:
425.559.4647
glenn.helton@pse.com
GLENN HELTON
PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING
INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER
PROJECT MANAGER TO MAKE EGOR RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION.
MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300, 2525.3400
REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS.
INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES
INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND
PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS.
MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED
BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300.
INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE
NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED
REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985.
REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300.
REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED.
INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARDS 2525.2100 FOR INSERTIONS AND 2525.3600 FOR
STANDARDS 2525.2100 AND 2525.3600.
PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700.
11.
12.
14.
13.
AND 2525.1200, AND PSE GAS FIELD PROCEDURE 4700.1500.
PER PSE GAS OPERATING STANDARD 2550.1600.
ABANDONMENT OR DEACTIVATION.
10.
9.
5.
6.
7.
8.
GAS OPERATING STANDARD 2525.2300.
4.
1.
2.
3.
OUTAGE.
STANDARD IP & LP GAS
REPLACEMENT CONSTRUCTION NOTES
15.ACTIVE SERVICES TO BE REPLACED DENOTED BY:#####
SAP BATCH YEAR & FOOTAGE
ACTUAL
LENGTH OF
RETIREMENT
MATERIAL
RETIRED
ORIGINAL
JOB
ORIGINAL
YEAR
PROPOSED
LENGTH OF
RETIREMENT
SIZE OF
RETIRED
MAIN
ROPE PROPOSED PIPE 2" MPE IP MAIN
WORK AREA
N/A RENTON
DUVALL AVE NE IMPROVEMENTS
PUBLIC IMPROVEMENT
4650 NE 10TH ST, RENTON WA 98059
109102802
N/A
1"=50'1/4
KING 30 CSPSKGPM
NW 10-23-05/SW 03-23-05 204.086 205.086/206.086
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
G. HELTON 425.559.4647
G. HELTON 425.559.4647
STOP TIME
START TIME
GAS MAIN PRESSURE & TESTING
TESTED BY
GAS MAIN INSTALLATION/RETIREMENT
SOAP AIR NITROGEN WATER
SOAP AIR NITROGEN WATER
STOP TIME
START TIME TESTED BY
TEST RESULTS P F
TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928
P F
Type/Work ManufacturerPipe Size Type Est Length Act Lgth
TYPE TEST
/ /
DATE OFF
PRESSURE
DATE ON
DATE OFF
TYPE TEST
PRESSURE
SYS MAOPDESIGN PRESS
DATE ON
2023 02/18
TEST RESULTS
/ /
/ /
/ /
Verify Testing Requirements, Chart vs Gauge
GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5
GASSED UP PIPELINE
PIPE
SEGMENT
FOREMAN'S DATENAME
60 IP088 - 60
RETIRE 4"PE 2029'
RETIRE 2"MPE 2'
INSTALL 4"MPE 2035'
INSTALL 2"MPE 32'
NE SUN
S
E
T
B
L
V
D
DUVALL AVE NENE 10TH STPLOT PLAN BSEE SHEET 2PLOT PLAN CSEE SHEET3PLOT PLAN DSEE SHEET4NE 12TH ST
S. ALNEEMA 253.234.6301
MATCHLINE A-A
THIS SHEET
MATCHLINE A-A
THIS SHEETPLOT PLAN ASEE SHEET 2SITE PLAN
SCALE: 1" = 50'-0" DUVALL AVE NENE 9TH ST
NE 7TH PL
NE 8TH ST
99+00100+00101+00102+00103+00104+00105+00106+00107+00108+00PI STA 100+00.00
CB#23
NE 10TH ST DUVALL AVE NEIP GAS FLOWIP GAS FLOW107010581102IP GAS FLOW
906+00907+00908+00909+00910+00911+00912+00913+00914+0084+0085+0086+0087+0088+00PC STA 86+83.48
891+00892+00893+00894+00IP GAS FLOW
IP GAS FLOW
IP GAS FLOWNE 7TH PL
NE 8TH ST
DUVALL AVE NEInspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: InfraSource Construction Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
4680 06/11
PLOT PLAN B
SCALE: 1" = 50'-0"
DESIGNED BY PUGET SOUND ENERGY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
Drawing Number
SAP Sup Order Nbr
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
HOLE HOG TABLE
CALLOUT LOCATION DEPTH LENGTH
BP1 START
BP2 END
BP3 START
BP4 END
BP5 START
BP6 END
BP7 START
BP8 END
BP9 START
BP10 END
BP11 START
BP12 END
BP13 START
BP14 END
BP15 START
BP16 END
BP17 START
BP18 END
BP19 START
BP20 END
ROPE PROPOSED PIPE 2" MPE IP MAIN
N/A RENTON
DUVALL AVE NE IMPROVEMENTS
PUBLIC IMPROVEMENT
4650 NE 10TH ST, RENTON WA 98059
109102802
N/A
1"=50'2/4
KING 30 CSPSKGPM
NW 10-23-05/SW 03-23-05 204.086 205.086/206.086
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
G. HELTON 425.559.4647
G. HELTON 425.559.4647
TIE IN
STOPPER 4"X150 B/O &
ELBOW 4"X90° WELD
23'N C/L & 10'W C/L
____'N C/L & ____'W C/L
TRANSITION FITTING 4" MPE
25'N C/L & 10'W C/L
____'N C/L & ____'W C/L
CP WIRE #10 TEST LEAD &
CP TEST LEAD BOX COMPLETE
___'N C/L & ___'W C/L
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4'-8")
560'N C/L, ____'N C/L
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4'-8")
658'N C/L, ____'N C/L
(____')MATCHLINE B-B
SHEET 3
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4'-10")
806'N C/L, ____'N C/L
M. HAACK 206.795.5834
S. ALNEEMA 253.234.6301
PLOT PLAN A
SCALE: 1" = 50'-0"
POTHOLE 4" PE MN AT EXISTING 18"
STORM CROSSING ( 62'S of NE 8TH ST C/L,
28'E OF DUVALL AVE NE C/L ).
CALL CM OR PM AND LET THEM
KNOW WHAT THE SEPARATION IS.
TEE TAP 4"X5/8" MPE
(PURGE TEE)
____'N C/L & ____'W C/L
109+00110+00111+00112+00113+00114+00115+00116+00117+00PI STA 113+17.25
NE 12TH ST DUVALL AVE NE1568'N
IP GAS FLOW1102461346211
IP GAS FLOW
915+00916+00917+00918+00919+00920+00921+00922+00923+00IP GAS FLOWIP GAS FLOW
Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: InfraSource Construction Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
4680 06/11
PLOT PLAN C
SCALE: 1" = 50'-0"
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
HOLE HOG TABLE
CALLOUT LOCATION DEPTH LENGTH
BP1 START
BP2 END
BP3 START
BP4 END
BP5 START
BP6 END
BP7 START
BP8 END
BP9 START
BP10 END
BP11 START
BP12 END
BP13 START
BP14 END
BP15 START
BP16 END
BP17 START
BP18 END
BP19 START
BP20 END(____')ROPE PROPOSED PIPE 2" MPE IP MAIN
N/A RENTON
DUVALL AVE NE IMPROVEMENTS
PUBLIC IMPROVEMENT
4650 NE 10TH ST, RENTON WA 98059
109102802
N/A
1"=50'3/4
KING 30 CSPSKGPM
NW 10-23-05/SW 03-23-05 204.086 205.086/206.086
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
DESIGNED BY PUGET SOUND ENERGY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
Drawing Number
SAP Sup Order Nbr
G. HELTON 425.559.4647
G. HELTON 425.559.4647
MATCHLINE B-B
SHEET 2
MATCHLINE C-C
SHEET 4
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4'-8")
1545'N C/L, ____'N C/L
PROPOSED PIPE 2" MPE IP MAIN
6'S C/L, ____'S C/L
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4'-10)
321'S C/L, ____'S C/L
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 4.5')
122'S C/L, ____'S C/L
BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR
FUTURE WATER CROSSING
(TOP OF NEW WATER PIPE IS AT 3'-9")
12'N C/L, ____'N C/L
FUTURE 4'X6' FILTERRA
M. HAACK 206.795.5834
S. ALNEEMA 253.234.6301
TIE IN
TEE 4"X4" INLINE TEE
6'S C/L & 10'W C/L
____'S C/ & ____'W C/L
CUT & CAP
CAP 2" MPE
10'S C/L & 39'W C/L
____'S C/L & ____'W C/L
DEACTIVATE IN PLACE
EXISTING 2" PE IP MAIN
ELBOW 2"X90° MPE
6'S C/L & 41'W C/L
___'S C/L & ___'W C/L
REDUCER 4"X2" MPE
6'S C/L & 12'W C/L
___'S C/L & ___'W C/L
TIE IN
TEE HV 2"X2" MPE
10'S C/L & 41'W C/L
____'S C/L & ____'W C/L
PROPOSED PIPE 2" MPE IP MAIN
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING AT 31'W C/L
(BOTTOM OF NEW STORM PIPE IS AT 4'-8")
6'S C/L, ____'S C/L
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
(____')(____')(____')
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
Scale: NTS
TIE IN DETAIL1
(____')
POLYVALVE 2" MPE (OPEN)
WITH VALVE BOX & SUPPORT
6'S C/L & 38'W C/L
____'S C/L & ____'W C/L
TEE TAP 2"X5/8" MPE
(GAUGE TEE)
____'S C/L & ____'W C/L
TEE TAP 2"X5/8" MPE
(PURGE TEE)
____'S C/L & ____'W C/L
118+00119+00120+00121+00122+00123+00123+36PC STA 117+69.32
PT STA 118+70.40
EP STA 123+35.94
NE SU
N
S
E
T
B
L
V
D
(
W
A
-
9
0
0
)
2038'N
IP GAS FLOWIP GAS FLOW46192
DUVALL AVE NE924+00925+00926+00927+00928+00929+00929+71IP GAS FLOWInspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: InfraSource Construction Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
4680 06/11
PLOT PLAN C
SCALE: 1" = 50'-0"
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
HOLE HOG TABLE
CALLOUT LOCATION DEPTH LENGTH
BP1 START
BP2 END
BP3 START
BP4 END
BP5 START
BP6 END
BP7 START
BP8 END
BP9 START
BP10 END
BP11 START
BP12 END
BP13 START
BP14 END
BP15 START
BP16 END
BP17 START
BP18 END
BP19 START
BP20 END
ROPE PROPOSED PIPE 2" MPE IP MAIN
N/A RENTON
DUVALL AVE NE IMPROVEMENTS
PUBLIC IMPROVEMENT
4650 NE 10TH ST, RENTON WA 98059
109102802
N/A
1"=50'4/4
KING 30 CSPSKGPM
NW 10-23-05/SW 03-23-05 204.086 205.086/206.086
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
DESIGNED BY PUGET SOUND ENERGY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
Drawing Number
SAP Sup Order Nbr
G. HELTON 425.559.4647
G. HELTON 425.559.4647
MATCHLINE C-C
SHEET 3
TOP OF PIPE TO BE BURIED AT 6' TO CLEAR
FUTURE STORM CROSSING
(BOTTOM OF NEW STORM PIPE IS AT 5')
2035'N C/L, ____'N C/L
TIE IN
ELBOW 4"X90° MPE
2041'N C/L & 27'W C/L
___'N C/L & ___'W C/L
ELBOW 4"X90° MPE
2041'N C/L & 10'W C/L
___'N C/L & ___'W C/L
(____')
DEACTIVATE IN PLACE
EXISTING 4" PE MAIN
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
Scale: NTS
TIE IN DETAIL2
PROPOSED PIPE 4" MPE IP MAIN
10'W C/L, ____'W C/L
BOTTOM OF PIPE TO BE BURIED AT 3.5' TO CLEAR
FUTURE WATER CROSSING
(TOP OF NEW WATER PIPE IS AT 4.5')
12'N C/L, ____'N C/L
M. HAACK 206.795.5834
S. ALNEEMA 253.234.6301
BOTTOM OF PIPE TO BE BURIED AT 3.5' TO CLEAR
FUTURE WATER CROSSING
(TOP OF NEW WATER PIPE IS AT 4.5')
TEE TAP 4"X5/8" MPE
(PURGE TEE)
____'N C/L & ____'W C/L