HomeMy WebLinkAboutJ_Setback_Variance_and_Code_Compliance_Analysis_v1.pdf
Canyon Terrace Lot 34
Setback Variance Narrative
&
Variance Request Justification
Our Job No. 17601
City of Renton
Prepared for:
Summit Homes
Prepared by:
H. George Newman, AICP
Barghausen Consulting Engineers, Inc.
18215 72nd Avenue South
Kent, WA 98032
December 3, 2019
Page 2 BCE 17601
Project Narrative
Proposed Land Use Action:
Administrative building setback variance for residential building permit on Lot 34, Canyon Terrace.
Pre-submittal Actions:
Prior to this submittal for a variance, there was a pre-application meeting with City staff and Summit Homes
on September 9, 2019.
Site Description:
The proposed action is located at 12302 S.E. 191st Street, Renton. The lot area is 4,174 SF. There are
no critical areas on or near this platted lot.
Project Description:
The proposed improvement includes a 2-story single family residence. Building elevations are included
with the submittal.
Figure 1. Recorded final plat of Canyon Terrace with Lot 34 highlighted
Page 3 BCE 17601
Figure 2. Lot 34 Building Area Exhibit
Showing Building Setback Dimensions from Right-of-Way and Property Lines
Variance Request & Justification
Code Citations from Renton Municipal Code below will be in italics while the justification responses will be
in normal text.
4-9-250 VARIANCES, WAIVERS, MODIFICATIONS, AND ALTERNATES:
A. PURPOSES:
1. Variances: A grant of relief from the requirements of this Title which permits construction
in a manner that otherwise is prohibited by this Title.
B. VARIANCE PROCEDURES:
Page 4 BCE 17601
1. Authority and Applicability for Administrative Variances: The Community and
Economic Development Administrator shall have the authority to grant variances from the
following development standards when no other permit or approval requires Hearing
Examiner review: (Ord. 5676, 12-3-2012)
a. Residential Land Uses: Lot width, lot depth, setbacks, allowed projections into setbacks,
building height, and lot coverage. Lot width, lot depth, and setback variations do not
require a variance if the request is part of a stream daylighting proposal.
5. Decision Criteria: Except for variances from critical areas regulations, a determination
shall be made in writing that the conditions specified below have been found to exist:
(Amd. Ord. 4835, 3-27-2000)
a. That the applicant suffers practical difficulties and unnecessary hardship and the
variance is necessary because of special circumstances applicable to subject property,
including size, shape, topography, location or surroundings of the subject property, and
the strict application of the Zoning Code is found to deprive subject property owner of
rights and privileges enjoyed by other property owners in the vicinity and under identical
zone classification.
Response: The size and shape of Lot 34 is very narrow in width ranging from 34 to 44
feet wide, and is a corner lot fronting on both S.E. 191st Street and 123rd Avenue S.E.
This lot was approved through the preliminary plat and final plat approval process. The
intersection of these two streets is somewhat angular which makes intersection site
distance an important safety factor. Therefore, there is no front yard reduction or
variance proposed. Per the house floorplan included with this variance application
submittal, the garage has an exterior dimension of 20.5 feet creating an interior minimum
depth of 19.5 needed for off-street parking. To avoid requesting a front yard setback
variance from 20 to 19 feet, a side yard setback variance from 5 to 4 feet is being
requested. The side yard setback variance of 1 foot, from 5 feet to 4 feet is shown on
the Lot 34 Building Area Exhibit. This is a relatively minor reduction. Historically, such
reductions have been considered minor under the di minimis doctrine. This doctrine
holds that insignificant and trivial discrepancies are ignored by the law.
b. That the granting of the variance will not be materially detrimental to the public welfare
or injurious to the property or improvements in the vicinity and zone in which subject
property is situated.
Response: By maintaining the front setback of 20 feet, the intersection site distance is
maintained. Had a front setback variance been requested versus the side yard setback
variance, there is a possibility that the intersection site distance would be slightly
reduced, potentially leading to a slight reduction in public safety for vehicles turning at
the intersection and pedestrians using the crosswalk in front of Lot 34. The 1-foot side
yard variance should not adversely affect adjacent Lot 33. No significant material
detriment to the residential enjoyment of adjacent and nearby properties will be caused
by the requested setback reduction.
c. That approval shall not constitute a grant of special privilege inconsistent with the
limitation upon uses of other properties in the vicinity and zone in which the subject
property is situated.
Page 5 BCE 17601
Response: There is sufficient demonstration in the record that a suitable and
reasonably sized residence with garage cannot be developed on the lot without the
requested variance. A reasonably sized residence with garage is a property right
commonly enjoyed by other lot owners in the area. An infringement of that right would
be caused by denial of the requested variance. And the variance has been sufficiently
demonstrated to be the minimum reasonably necessary to respect the property right and
alleviate the hardship presented by the property's special circumstances. The
application conforms to this criterion.
d. That the approval is a minimum variance that will accomplish the desired purpose. (Amd.
Ord. 4835, 3-27-2000; Ord. 5675, 12-3-2012)
Response: The 1-foot variance will accomplish the purpose of a minimal garage depth
at 20 feet per the Main Floor Plan included with this submittal. The proposed building
envelope on the lot will meet all other zoning dimensional requirements.
General Conclusions:
As noted, the single-family residence conforms to the de minimis test and the variance is
necessary to allow the applicant to build a residence on the lot with the very minor discrepancy
from the setback requirement. As the single family residence qualifies under the de minimis
doctrine and in so doing also conforms to the applicable four variance criteria, the setback
variance shall be granted for the single family residence.