Loading...
HomeMy WebLinkAboutMFP19006164.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP19006164 IVR Number: 19006164 Permit Informaon Permit Name:Century Link Permits Address/Locaon :11/12/2019Application Date:0723059007Parcel Number:616 W PERIMETER RD Permit Type:12/11/2019Issue Date:Franchise Permit Work Class:12/10/2020Expiration Date:Major Utility Job Number:N.550179Franchise Type:Telephone Description:REVISION: Century Link to access HH207, Ped1 Ped3, place new HH, and replace peds 4 7 with new BD7CMPT. Century Link to access HH259, HH235, HH236, HH237, HH246, HH247, HH260, HH261, HH262, HH263, HH264, HH265, and HH266. Dig 2 bore bits and bore 75' and trench 50'. Overlash onto 5 poles, place 3 new risers on P1, P2, and P4 and place new 264TA HH at base of P4. Pothole all existing utilities. Restoration per City of Renton standards. PRE CONSTRUCTION MEETING REQUIRED APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link Applicant C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐ Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Austin Sweeney Qwest Corp d/b/a CenturyLink Austin Sweeney 253-766-7549 austin.sweeney@centurylink.com 616 W PERIMETER RD N.550179 CenturyLink to access HH259, HH235, HH236, HH237, HH246, HH247, HH260, HH261, HH262, HH263, HH264, HH265, HH266, , dig 2 (4’x4’) bore pits, bore approx. 75’, trench approx. 50', overlash on 5 poles, place 3 new risers (1 on P1 and 2 on P4), and place new 264TA HH at the base of P4. 125' North Sky Communications 503.582.1263 NORTHSC857Q4 BL.028638 11/12/19 MFP19006164 Scott Warlick 11/18/2019 Justin Johnson 12-4-2019 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov REVISION - FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Only Current Issued Permits Qualify for a Revision. For any work related to an expired or finaled permit, a new Franchise Permit Application shall be required. Submit an electronic copy of the plans with the Revision Franchise Permit Application to franchisepermits@rentonwa.gov. Permit # Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Approved Description of Work: Proposed Description of Work: Reason for change of work: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date MFP19006164 Qwest Corp d/b/a CenturyLink N.550179 Austin Sweeney 253-372-5311 amy.silbaugh@centurylink.com 616 W Perimeter Road Century Link to access HH259, HH235, HH236, HH237, HH246, HH247, HH260, HH261, HH262, HH263, HH264, HH265, and HH266. Dig 2 bore bits and bore 75' and trench 50'. Overlash onto 5 poles, place 3 new risers on P1, P2, and P4 and place new 264TA HH at base of P4. Pothole all existing utilities. Restoration per City of Renton standards. PRE CONSTRUCTION MEETING REQUIRED APPROVED WITH COMMENTS OR REDLINES CenturyLink to access HH207, ped1, ped2, ped3, place new HH, and replace peds 4-7 with new BD7CMPT. in addition to the already approved work. Original path found not viable once in field. New path required to bring service to customer 12/30/2019 1/13/2020Scott Warlick Holly Powers 1/13/2020 1/13/2020 RESTORATION PER CITY OF RENTON STANDARDS CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: N.550179 North Sky Communications 503.582.1263 Austin Sweeney 253.766.7549 23315 66th Ave S Kent, WA 98032 austin.sweeney@centurylink.com 616 W PERIMETER RD Reset FormPrint Form Austin Sweeney Austin Sweeney 11/12/19 MFP19006164 8:00AM - 3:00PM Monday - Friday Justin Johnson 12/4/2019 SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019 Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com Legend Cone Flagger Not to scale Scale Marker Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # PERIMETER RD W @ E PERIMETER RD P1-P5 AERIAL MOVING OPERATION SPEEDLIMIT25 Comments: AERIAL FIBER PLACEMENT. WEST SIDE PERIMETER RD W, NORTH OF E PERIMETER RD. WORK TRUCKS WILL TRAVEL WITH TRAFFIC. MOVING OPERATION WITH FLAGGERS. FLAGGERS WILL HOLD ALL TRAFFIC FOR CROSSINGS.FLAGGERS WILL ASSIST PEDESTRIANS.NX X X X X ROADWORKAHEADW20-1 ROADWORKAHEADW20-1BE PREPAREDTO STOP W20-7b W20-7a BE PREPAREDTO STOPW20-7bW20-7a100' 100' 100'100' P4 P1 PERIMETER RD W E PERIMET E R R D www.invarion.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAXSharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019 Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com RAINIER AVE S @ NW 5TH ST HH 266 & BP1 RIGHT LANE CLOSURE Comments: ACCESS HH 266 & SET UP BP1. WEST SIDE RAINIER AVE S, NORTH OF NW 5TH ST RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TOACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 35 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'NW 5TH STRAINIER AVE S Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work TruckNDETOURM4-9bDETOURM4-9bHH 266 BP1 225'WORK AREA 11 X 275 www.invarion.com Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45 Designed for CenturyLinkSharon Martos Approved 10/17/2019 Traffic Control SupervisorTCS # 010745 Phone 253-737-5198sharon.martos@gmail.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ NW 5TH ST BP2 & TRENCH RIGHT LANE CLOSURE Comments: SET UP BP2 - TRENCH EAST SIDE RAINIER AVE S, NORTH OF NW 5TH ST RIGHT LANE CLOSURE.SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 35 ROADWORKAHEADW20-1NW 5TH STRAINIER AVE S NROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2ROADWORKAHEAD W20-1 BP2 350'350'350'225' Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck WORK AREA 11 X 265 www.invarion.com Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45 Designed for CenturyLinkSharon Martos Approved 10/17/2019 Traffic Control SupervisorTCS # 010745 Phone 253-737-5198 sharon.martos@gmail.com Legend Cone Not to scale Scale Marker Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ RENTON AVE EXT. HH 235 RIGHT LANE CLOSURE SPEEDLIMIT35 Comments: ACCESS HH 235. WEST SIDE RAINIER AVE S, SOUTH OF RENTON AVE EXT. RIGHT LANE CLOSURE.SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.NROAD WORK AHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RIGHT LANE CLOSEDAHEAD W20-5W4-1ROADWORKAHEADW20-1DETOURM4-9bDETOURM4-9bHH 235 WORK AREA 11 X 120 350'350' 350' RAINIER AVE S R E N T O N A V E E X T ROADWORKAHEADW20-1www.invarion.com DWYDWY Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon Martos Approved 10/17/2019Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ RENTON AVE EXT. HH 246 RIGHT LANE CLOSURE SPEEDLIMIT35 ROADWORKAHEAD W20-1 DETOURM4-9bDETOURM4-9bNW 3RD PLRAINIER AVE S Comments: ACCESS HH 246. WEST SIDE RAINIER AVE S, NORTH OF RENTON AVE EXT.RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.NHH 246 WORK AREA 11 X 270 ROADWORKAHEADW20-1NE L S O N P L N W ROADWORKAHEADW20-1W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1350'350'225'350'RENTON AVE EXT.AIRPORT WAYwww.invarion.com DWYDWY Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon Martos Approved 10/17/2019Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ NELSON PL NW HH 247 RIGHT LANE CLOSURE SPEEDLIMIT35 ROADWORKAHEAD W20-1 DETOURM4-9bDETOURM4-9bNW 3RD PLRAINIER AVE S Comments: ACCESS HH 247. WEST SIDE RAINIER AVE S, SOUTH OF NELSON PL NW.RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.NHH 247 WORK AREA 11 X 275 ROADWORKAHEADW20-1NE L S O N P L N W ROADWORKAHEADW20-1W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1350'350'350'225' www.invarion.com DWYDWY Not to scaleNOT TO SCALE Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ NELSON PL NW HH 260 RIGHT LANE CLOSURE SPEEDLIMIT35 ROADWORKAHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2DETOURM4-9bDETOURM4-9b225'NW 3RD PLRAINIER AVE S Comments: ACCESS HH 260. WEST SIDE RAINIER AVE S,SOUTH OF NELSON PL NW. RIGHT LANE CLOSURE.SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.NHH 260 WORK AREA 11 X 125 ROADWORKAHEADW20-1NE L S O N P L N W ROADWORKAHEADW20-1350'350'350' www.invarion.com DWYDWY TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon Martos Approved 10/17/2019Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com RAINIER AVE S @ NW 3RD PL HH 261 RIGHT LANE CLOSURE SPEEDLIMIT35 ROADWORKAHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2DETOURM4-9bDETOURM4-9b225'NW 3RD PLRAINIER AVE S Comments: ACCESS HH 261. WEST SIDE RAINIER AVE S, NORTH OF NW 3RD PL. RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TOACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.NHH 261 WORK AREA 11 X 125 350'350'350'ROADWORKAHEADW20-1www.invarion.com DWY DWY DWY Not to scaleNOT TO SCALE Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45 Designed for CenturyLinkSharon MartosApproved 10/17/2019 Traffic Control SupervisorTCS # 010745 Phone 253-737-5198 sharon.martos@gmail.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # RAINIER AVE S @ NW 4TH PL HH 262 RIGHT LANE CLOSURE SPEEDLIMIT35 DETOURM4-9bDETOURM4-9bHH 262 WORK AREA 11 X 120 NW 4TH PLROADWORKAHEAD W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2RAINIER AVE S Comments: ACCESS HH 262. WEST SIDE RAINIER AVE S, SOUTH OF NW 4TH PL. RIGHT LANE CLOSURE.SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.N350'350'350'225' www.invarion.com DWY DWY TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon Martos Approved 10/17/2019Traffic Control Supervisor TCS # 010745 Phone 253-737-5198sharon.martos@gmail.com RAINIER AVE S @ NW 4TH PL HH 263 RIGHT LANE CLOSURE SPEEDLIMIT35 DETOURM4-9bDETOURM4-9bHH 263 WORK AREA 11 X 130 NW 4TH PLROADWORKAHEAD W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'225' RAINIER AVE S Comments: ACCESS HH 263. WEST SIDE RAINIER AVE S, SOUTH OF NW 4TH PL. RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS.SPOTTER WILL ASSIST PEDESTRIANS.Nwww.invarion.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45 Designed for CenturyLinkSharon Martos Approved 10/17/2019 Traffic Control SupervisorTCS # 010745 Phone 253-737-5198sharon.martos@gmail.com RAINIER AVE S @ NW 4TH PL HH 264 RIGHT LANE CLOSURE Comments: ACCESS HH 264. WEST SIDE RAINIER AVE S, SOUTH OF NW 4TH PL.RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 35 NW 5TH STNW 4TH PLROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350' RAINIER AVE S NDETOURM4-9bDETOURM4-9bDWY 225' Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck ROADWORKAHEAD W20-1 HH 264 WORK AREA 11 X 80 www.invarion.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45 Designed for CenturyLinkSharon Martos Approved 10/17/2019 Traffic Control SupervisorTCS # 010745 Phone 253-737-5198sharon.martos@gmail.com RAINIER AVE S @ NW 5TH ST HH 265 RIGHT LANE CLOSURE Comments: ACCESS HH 265. WEST SIDE RAINIER AVE S, NORTH OF NW 5TH STRIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 35 NW 5TH STNW 4TH PLDETOURM4-9bDETOURM4-9bROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'225' RAINIER AVE S NHH 265 WORK AREA 11 X 270 Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck www.invarion.com TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAXSharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019 Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com RAINIER AVE S @ NW 5TH ST HH 266 & BP1 RIGHT LANE CLOSURE Comments: ACCESS HH 266 & SET UP BP1. WEST SIDE RAINIER AVE S, NORTH OF NW 5TH ST RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED PER ADA REQUIREMENTS TOACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 35 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'NW 5TH STRAINIER AVE S Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work TruckNDETOURM4-9bDETOURM4-9bHH 266 BP1 225'WORK AREA 11 X 275 www.invarion.com 11 S TOBIN ST HA Y E S P L S W SW VICTORIA ST 90 A V E S 11 11 11 11 11 11 11 RAINIER AVE SRENTON AVE EXTE N S I O NRAINIER AVE STRAFFIC CONTROL PLAN JOB # N.337060.C.45 PERMIT # Designed for: CENTURYLINK Project # N.337060.C.45 Darlene DurrTraffic Control SupervisorTCS # 011915 Approved 7/15/19 Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:7/15/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.337060.C.45 CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr Legend WORK AREA CONES Arrowboard (Chevron) WORK TRUCK Plan Scale 1 : 2468 (1'' = 206')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 RIGHT LANECLOSEDAHEAD W20-5 W4-2 225'MERGINGTAPERWORK AREA 11' X 250' WORK AREA 11' X 130' HH 236 REPLACE LID ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 350' 350' 350' 350' 350' 350' Comments: THIS IS TO ACCESS HH 236 AND REPLACE LID LOCATED IN THE WEST SIDE OF RAINIER AVE S SOUTH OF RENTON AVE EXTENSION. THIS IS A RIGHT LANE CLOSURE OF SOUTHBOUND RAINIER AVE S NORTH OF RENTON AVE EXTENSION TO SOUTH OF WORK AREA. SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA. RAINIER AVE S @ RENTON AVE EXTENSION HH 236 ACCESS / NEW LID PLACEMENT SB RIGHT LANE CLOSURE N SPEEDLIMIT 35 www.invarion.com 11 S TOBIN ST HA Y E S P L S W SW VICTORIA ST 90 A V E S 11 11 11 11 11 11 11 RAINIER AVE SRENTON AVE EXTE N S I O NRAINIER AVE SRAINIER AVE S @ RENTON AVE EXTENSION HH 237 ACCESS / NEW LID PLACEMENT SB RIGHT TURN LANE CLOSURE TRAFFIC CONTROL PLAN JOB # N.337060.C.45 PERMIT # Designed for: CENTURYLINK Project # N.337060.C.45 Darlene Durr Traffic Control SupervisorTCS # 011915 Approved 7/12/19 Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:7/12/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.337060.C.45 CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr Legend WORK AREA WORK TRUCK CONES SPOTTER Plan Scale 1 : 2468 (1'' = 206')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX AIRPORT WAY HH 237 WORK AREA 11' X 200' ROADWORKAHEAD W20-1 RIGHT LANECLOSEDAHEAD W20-5 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 350'350' 350' 350' 350' Comments: THIS IS TO ACCESS HH 237 AND REPLACE LID LOCATED IN THE WEST SIDE OF RAINIER AVE S NORTH OF RENTON AVE EXTENSION. THIS IS A RIGHT LANE CLOSURE OF SOUTHBOUND RIGHT TURN LANE OF RAINIER AVE S NORTH OF RENTON AVE EXTENSION . SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA. N SPEEDLIMIT 35 REPLACE LID www.invarion.com 11 S TOBIN ST HA Y E S P L S W SW VICTORIA ST 90 A V E S RENTON AVE EXTENSIO N11 11 11 11 11 11 11 RAINIER AVE STRAFFIC CONTROL PLAN JOB # N.337060.C.45 PERMIT # Designed for: CENTURYLINK Project # N.337060.C.45 Darlene DurrTraffic Control SupervisorTCS # 011915 Approved 7/12/19 Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:7/12/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.337060.C.45 CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr Legend WORK AREA CONES Arrowboard (Chevron) SPOTTER WORK TRUCKPlan Scale 1 : 2468 (1'' = 206')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAXMERGINGTAPERHH 259 225'SIDEWALK CLOSEDAHEADCROSS HERER9-11(L)W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1350' 350' 350' 350' 350' 200'ROADWORKAHEADW20-1WORK AREA 11' X 325' RAINIER AVE S @ HAYES PL SW HH 259 ACCESS SB RIGHT LANE CLOSURE WEST SIDEWALK CLOSURE Comments: THIS IS TO ACCESS HH 259 LOCATED IN THE WEST SIDE OF RAINIER AVE S NORTH OF HAYES PL SW, THIS IS A RIGHT LANE CLOSURE OF SOUTHBOUND RAINIER AVE S NORTH OF HAYES PL SW. WEST SIDEWALK CLOSED AT WORK AREA. PEDESTRIANS DETOURED AT RENTON AVE EXTENSION AND S 2ND ST. SPOTTER WILL ASSIST AT WORK AREA. N SPEEDLIMIT 35 www.invarion.com Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019 Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com Legend Cone Flagger Not to scale Scale Marker Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT #NTRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # PERIMETER RD W @ E PERIMETER RD P1 - RISER ONE LANE 2-WAY SPEED LIMIT25 Comments: ACCESS P1. PLACE NEW RISER. WEST SIDE PERIMETER RD W, NORTH OFE PERIMETER RD. ONE LANE 2-WAY WITH FLAGGERS. FLAGGERS WILL ASSIST PEDESTRIANS.NX ROADWORKAHEADW20-1ROADWORKAHEADW20-1 BE PREPARE D TO STOP W20-7b W20-7a BE PREPAR ED TO S TOPW20-7bW20-7a100'100' PERIMETER RD W E PERIMETER RDWORK AREA 12 X 90 P1 350' 350' 50' www.invarion.com Not to scaleNOT TO SCALE Date:10/17/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.550179 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Sharon Martos Project # N.550179 C.45Designed for CenturyLink Sharon MartosApproved 10/17/2019 Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.com Legend Cone Flagger Not to scale Scale Marker Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT #NTRAFFIC CONTROL PLAN JOB # N.550179 C.45 PERMIT # PERIMETER RD W @ E PERIMETER RD P4-(2) RISERS & NEW HH ONE LANE 2-WAY SPEED LIMIT25 Comments: ACCESS P4. PLACE 2 NEW RISERS. PLACE NEW HH. WEST SIDE PERIMETER RD W, NORTH OF E PERIMETER RD. ONE LANE 2-WAY WITH FLAGGERS. FLAGGERS WILL ASSIST PEDESTRIANS.NX ROADWORKAHEADW20-1 ROADWORKAHEADW20-1BE PREPAREDTO STOP W20-7b W20-7a BE PREPAREDTO STOPW20-7bW20-7a100' 100' 100'100' PERIMETER RD W E PERIMET E R R D P4 NW HH WORK AREA 12 X 90 50' www.invarion.com RAINER AVE N PERIMETER RD W NSPEEDLIMIT 25 TRAFFIC CONTROL PLAN JOB # N.351774.C.45 PERMIT # Designed for: CENTURYLINKProject # N.351774.C.45 Drafted By: Jorgia Durr Approved By: Darlene DurrTraffic Control Supervisor TCS # 011915 Approved 12/18/19Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:12/18/19 Project:N.351774.C.45 APPROVED BY:DARLENE DURR TCS # 011915CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)DRAFTED BY:JORGIA DURR Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr Legend HANDHOLE WORK TRUCK CONES FLAGGER Work Area Plan Scale 1 : 2636 (1'' = 220')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX PERIMETER RD W @ RAINER AVE N HH 207 ACCESS ONE LANE TWO WAY WITH FLAGGERS Comments: THIS IS TO ACCESS HH 207 THIS IS A ONE LANE TWO WAY WITH FLAGGERS FLAGGERS WILL ASSIST PEDESTRIANS AT WORK AREA ROADWORKAHEAD W20-1 W20-7a BE PREPAREDTO STOP W3-4 ROADWORKAHEAD W20-1W20-7a BE PREPAREDTO STOP W3-4 HH 207 WORK AREA 10' X 90' www.invarion.com NSPEEDLIMIT 25 PED 1 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 W20-7a W20-7a BE PREPAREDTO STOP W3-4 BE PREPAREDTO STOP W3-4WORK AREA 10' X 90' RAINER AVE N PERIMETER RD W TRAFFIC CONTROL PLAN JOB # N.351774.C.45 PERMIT # Designed for: CENTURYLINK Project # N.351774.C.45 Drafted By: Jorgia Durr Approved By: Darlene Durr Traffic Control Supervisor TCS # 011915 Approved 12/18/19Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:12/18/19 Project:N.351774.C.45 APPROVED BY:DARLENE DURR TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)DRAFTED BY:JORGIA DURR Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm. Darlene Durr Legend PEDESTAL WORK TRUCK CONES FLAGGER Work Area Plan Scale 1 : 2636 (1'' = 220')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX PERIMETER RD W @ RAINER AVE N PED 1 ACCESS ONE LANE TWO WAY WITH FLAGGERS Comments: THIS IS TO ACCESS PED 1 LOCATED ON THE WEST SIDE OF PERIMETER RD W THIS IS A ONE LANE TWO WAY WITH FLAGGERS FLAGGERS WILL ASSIST PEDESTRIANS AT WORK AREA www.invarion.com NSPEEDLIMIT 25 PED 2 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 W20-7a W20-7a BE PREPAREDTO STOP W3-4 BE PREPAREDTO STOP W3-4 WORK AREA 10' X 90' RAINER AVE N PERIMETER RD W TRAFFIC CONTROL PLAN JOB # N.351774.C.45 PERMIT # Designed for: CENTURYLINK Project # N.351774.C.45 Drafted By: Jorgia Durr Approved By: Darlene Durr Traffic Control Supervisor TCS # 011915 Approved 12/18/19Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:12/18/19 Project:N.351774.C.45 APPROVED BY:DARLENE DURR TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)DRAFTED BY:JORGIA DURR Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm. Darlene Durr Legend PEDESTAL WORK TRUCK CONES FLAGGER Work Area Plan Scale 1 : 2636 (1'' = 220')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX PERIMETER RD W @ RAINER AVE N PED 2 ACCESS ONE LANE TWO WAY WITH FLAGGERS Comments: THIS IS TO ACCESS PED 2 LOCATED ON THE EAST SIDE OF PERIMETER RD W THIS IS A ONE LANE TWO WAY WITH FLAGGERS FLAGGERS WILL ASSIST PEDESTRIANS AT WORK AREA www.invarion.com RAINER AVE S PERIMETER RD W Comments: THIS IS TO REPLACE PED 7 LOCATED ON THE EAST SIDE OF PERIMETER RD W RESTORE AS REQUIRED THIS IS A ONE LANE TWO WAY WITH FLAGGERS FLAGGERS WILL ASSIST PEDESTRIANS AT WORK AREA NSPEEDLIMIT 25 TRAFFIC CONTROL PLAN JOB # N.351774.C.45 PERMIT # Designed for: CENTURYLINK Project # N.351774.C.45 Drafted By: Jorgia Durr Approved By: Darlene Durr Traffic Control Supervisor TCS # 011915 Approved 12/18/19Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:12/18/19 Project:N.351774.C.45 APPROVED BY:DARLENE DURR TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)DRAFTED BY:JORGIA DURR Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be ____am to ____pm. Darlene Durr Legend PEDESTAL WORK TRUCK CONES FLAGGER Work Area Plan Scale 1 : 2636 (1'' = 220')NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX PED 7 WORK AREA 10' X 60' W20-7a W20-7a BE PREPAREDTO STOP W3-4 BE PREPAREDTO STOP W3-4 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 PERIMETER RD W @ RAINER AVE S PED 7 REPLACEMENT / RESTORE ONE LANE TWO WAY WITH FLAGGERS www.invarion.com NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.4390755051516000”NVICINITY MAPCUSTOMER NAME: HARRIS / FAA-MSLCON: GINA MINA- NEALPHONE #: (425) 793-4438EMAIL: gina.mina-neal@faa.govPROJECT ID:  A.2633903ARMOR OR DSR #: 0508-1950659REVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION 1 ALL COMBINE 3 CADS INTO 1 (N.056456, N.351774 & N.550179 UNDER JOB # N.550179 SL 12/11/19SCOPE OF WORK:POF: @ HANDHOLE 259, PLACE NEW 72CT FIBER IN EXISTING CONDUIT THRU HANDHOLES 235, 236, 237, 246, 247, 260, 261, 262, 263, 264, 265, & THEN TO 266. @HANDHOLE 266, DIG 4'X4' BORE PIT 1, BORE 1-4" & PLACE NEW 48CT FIBER TO BORE PIT 2, THEN TRENCH 1-4" 50FT TO POLE A1366492. @ POLE A1366492, OVERLASH72CT FIBER TO EXISTING AERIAL THRU POLE A1365171 & A1366494 TO A1366495. @ POLE A1366495, ADD 2-4" RISERS AND PLACE NEW 264TA FOR FIBER SPLICE.PLACE (2) NEW FIBERS BACK UP POLE, OVERLASH TO POLE A1366496. @ POLE A1366496, RISER DOWN POLE AND PLACE IN EXISTING 3" CONDUIT TO CUSTOMERSBUILDING MPOE.POLE A1366496, RISER DOWN INTO EXISTING 4" CONDUIT & PLACE IN EXISTING CONDUIT THROUGH HANDHOLE 207, PEDESTAL 1, PEDESTAL 2, TO PEDESTAL 3.820 W PERIMETER RD, OVERSET EXISTING 2-4” WITH NEW 30”X60” VAULT IN SOFT SURFACE. REPLACE PED 4, 5,6 & 7 WITH NEW BD7CMPH PEDESTALS. PLACE NEWINNERDUCT IN EXISTING CONDUIT FROM NEW 30”X60” VAULT TO PED 6.DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057110MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.com TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSDRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057210MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.com NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057310MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.SEE SHEET 4 C/L C/L C/L C/L C/L C/L EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EO P EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W EOP R /W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP E O P R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/ W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EO P EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W C/L C/L C/L C/L TT EOP TTRAINIER AVE S.SIDEWALKNOTE:POF: @ HANDHOLE 259, PLACE 378' OF NEW72 COUNT FIBER WITH LRE27, 479-480 INEXISTING CONDUIT THRU HANDHOLE 235.LEAVE 50' FIBER LOOP.NOTE:@ HANDHOLES 235, PLACE 120'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 236.LEAVE 50' FIBER LOOP.NOTE:@ HANDHOLES 236, PLACE 196'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 237.LEAVE 50' FIBER LOOP.NOTE:@ HANDHOLES 237, PLACE 92' OFNEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 246.LEAVE 50' FIBER LOOP.SIDEWALKHAYES PLACE SW RENTON AVEEXTENSION6' SIDEWALK6' SIDEWALKDRIVEWAYDRIVEWAYDRIVEWAYN. AIRPORT WAYSIDEWALKSIDEWAL K S. TOBIN STREET SIDEWALK SIDEWALK 73771033274685425110040'18'27'68'56'70'3'3'3'2'5'30'44'56'79'20'30'37'0+00 POF CTL HH 259 3+78 CTL HH 2354+98 CTL HH 2366+94 CTL HH 237 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057410MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.SEE SHEET 3 SEE SHEET 5 EOP EOP EOP R/W R /W R/W R/W R /W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R /W R/W R /W R /W R/W R /W R/W R/W EOP EOP E O P EOP EOP EOP R/W R/W R /W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W RAINIER AVE S.SIDEWALK EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W DRIVEWAYDRIVEWAYDRIVEWAY EOP EOP 5' SIDEWALKNOTE:@ HANDHOLES 246, PLACE 164'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 247.LEAVE 50' FIBER LOOP. C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L NOTE:@ HANDHOLES 247, PLACE 220'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 260.LEAVE 50' FIBER LOOP.T2'3'DRIVEWAYT2'T1'125'7+86 CTL HH 2469+50 CTL HH 24711+70 CTL HH 260NOTE:@ HANDHOLES 260, PLACE 295'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 261.LEAVE 50' FIBER LOOP.92'74'69'65'NELSON PLACE NWSIDEWALKNW 3rd PLACE SIDEWALK DRIVE W A Y DRIVE W A Y DRIVEWAY14'45'22'257271 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057510MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.SEE SHEET 4 SEE SHEET 6 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T1'14+65 CTL HH 261 NOTE:@ HANDHOLES 262, PLACE 252'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 263.LEAVE 50' FIBER LOOP.55'355365401251453T2'16+17 CTL HH 262 T2'18+69 CTL HH 263 T1'21+34 CTL HH 264 DRIVEWAYDRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY57'56'2'38'22'NOTE:@ HANDHOLES 261, PLACE 152'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 262.LEAVE 50' FIBER LOOP.NOTE:@ HANDHOLES 263, PLACE 265'OF NEW 72 COUNT FIBER WITHLRE27, 479-480 IN EXISTINGCONDUIT THRU HANDHOLE 264.LEAVE 50' FIBER LOOP.NOTE:@ HANDHOLES 264,PLACE 290' OF NEW 72COUNT FIBER WITHLRE27, 479-480 INEXISTING CONDUIT THRUHANDHOLE 265. LEAVE 50'FIBER LOOP.RAINIER AVE S.SIDEWALK5' SIDEWALK59'28'30'27' NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057610MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYEDOR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITHREFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGHTS OF WAY AND/OREASEMENTS PRIOR TO CONSTRUCTION.SEE SHEET 5 SEE SHEET 7 505 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T1'24+24 CTL HH 265 EOP EOP R/W R/W C/L NW 4th PLACE(U-HAUL) EOP EOP EOP EOP R/W R/W C/L C/L NW 5th PLACE EOP EOP RAINIER AVE S.SIDEWALK5' SIDEWALK515 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C /L C/L C/L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP 30'18'NOTE:@ HANDHOLES 265, PLACE170' OF NEW 72 COUNT FIBERWITH LRE27, 479-480 INEXISTING CONDUIT THRUHANDHOLE 266. LEAVE 50'FIBER LOOP.1'T4'25+94 CTL HH 266& 4'X4' BORE PIT5'DRIVEWAY18'DRIVEWAY DRIVEWAY EOP 65'42'80'56'50'75'NOTE:@ HANDHOLE 266, LEAVE 50' FIBER LOOP.FROM 4'X4' BORE PIT, BORE 4" CONDUIT &PLACE NEW 48 COUNT FIBER TO 2'X2'RECEIVING PIT THEN TRENCH 50' TOPOLE:  A1366492.NOTE:@ POLE:  A1366492, OVERLASH NEW 72 COUNT FIBERTO EXISTING COPPER ROUTE THRU POLE: A1366495& PLACE A NEW 264TA HANDHOLE WHERE WE WILLPLACE A NEW SPLICE CASE. THEN CONTINUEAERIAL, OVERLASH NEW 72 COUNT FIBER TOEXISTING COPPER ROUTE THRU POLE: A1366496.150'NOTE:@ 2'X2' RECEIVING PIT,TRENCH 50' OF 4"CONDUIT TO POLE: A1366492.SURFACE LEVEL4" CONDUITSURFACE LEVEL36"MINTRENCH/BORE TYPICALSTATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHER127+19318209/16581727'-5"A1366492RISER UP/PLACE 20' NEW 4" RISER/OVERLASH38'-1" NEUTRAL HOA27'-5" CTL HOAW. PERIMETER ROADDRIVEWAY26+69 2 'X2 'REC. PIT NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01616 W. PERIMETER ROADRENTON, WA 98057710MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYEDOR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITHREFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGHTS OF WAY AND/OREASEMENTS PRIOR TO CONSTRUCTION.SEE SHEET 6 NOTE:@ POLE: A1366496, RISER DOWN &PLACE 200' OF NEW 24 COUNT FIBERIN EXISTING 3" CBO TO CUSTOMER'SBUILDING MPOP.THEN PLACE 294' OF NEW 72F &2-1.25" INNERDUCT IN EXISTINGCONDUIT TO HANDHOLE 207.115'125'125' EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L C/L C/L C /L C /L C /L C /L C /L C/L C/L C/L C /L C /L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP 80'W. PERIMETER ROAD EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R /W R/W R/W R/W R /W R /W R /W R /W R/W NOTE:@ CUSTOMER BUILDING MPOP.PLACE NEW EQUIPMENT &TERMINATE LRE27, 479-480 IN FDP.STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHER228+69NO #29'-2"A1365171OVERLASH/TRIM TREE29'-2" CTL HOA70'25'RAINIER AVE S.SIDEWALK 5' SIDEWALK 34+34 MPOP616 W. PERIMETERRD.622 W.PERIMETERRD.608 W. PERIMETERRD.600 W. PERIMETERRD.DRIVEWAYDRIVEWAY EO P DRIVEWAYSTATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHER329+94 NO #29'-9"A1366494OVERLASH29'-9" CTL HOASTATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHER431+09NO #28A1366495OVERLASH/PLACE 2-4" RISER/SET NEW HH W/SPLICE CASE28' CTL HOASTATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHER532+34NO #26'-4"A1366496OVERLASH/RISER DOWN26'-4" CTL HOATNOTE:@ A1366495 & ADD 2-4" RISERSDOWN POLE THEN PLACE A NEW264TA HANDHOLE WHERE WE WILLPLACE A NEW SPLICE CASE.SEE SHEET 8NEW CTL HH NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01850 W. PERIMETER ROADRENTON, WA 98057810MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C C/L C/L C/L C/L C/L C/L C /L C /L C/L C /L C/L C/L C/L C/L C/L C /L C /L C /L C/L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R /W R /W R/W R /W R/W R /W R/W R/W R /W R /W R/W R/W R /W R /W R/W R/W R/W R/W R/W R/W R/W R/W R /W R /W R /W R/W R /W R/W R /W R /W R/W R /W R /W R/W R/W R /W R /W ””4' EOP9' EOP1.69'1.69'1.69'1.69' EOP EOP EOP EOP EOP EOP SEE SHEET 7 SEE SHEET 9 EOP EOP EOP EOP EOP EOP T NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01850 W. PERIMETER ROADRENTON, WA 98057910MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.SEE SHEET 8 SEE SHEET 10 C/L C/L C/L C/L C/L C /L C/L C/L C /L C/L C/L C /L C/L C/L C /L C /L C /L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP B/C B/C B/C B/C B/C B/C B/C B/C B /C B /C B/C B/C B /C B /C B/C B/C B/C B /C B /C B/C B/C B/C B /C B/C EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP B/C B/C B/C B/C B/C B/C B/C B/C B/C B/C B /C B/C B/C B/C B /C B /C B/C B/C B/C B /C B/C B/C B /C B/C C/L C/L C/L C/L C/L C/L C/L C /L C/L C/L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R /W R /W R /W R /W R /W R /W R/W R/W R/W R/W R/W R/W R/W R /W R /W R /W 50' EOP1.88'1.88' EOP EOP EOP EOP EOP EOP NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 10/08/1923N5E7N.550179W26226RNTNWA01850 W. PERIMETER ROADRENTON, WA 980571010MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.W PERIMETER RDDRIVEWAY TW PERIMETER RD850840820PARCEL 07230590074'PLACE NEW 30X60 HANDHOLEPLACE 3' SOUTH OF PED 44' FROM EOP7'PLACE 118' OFNEW 1.25" IDPED 4REPLACE WITH ABD7CMPTPLACE 140' OFNEW 1.25" ID3'PED 5REPLACE WITH ABD7CMPT25'PLACE 250' OFNEW 1.25" ID9'PED 6REPLACE WITH ABD7CMPTPED 7REPLACE WITH ABD7CMPT4' R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L EO P EOP EOP EOP EOP EOP EOP EOP SEE SHEET 9 RAINIER AVE N 23315 66th Ave S Kent, WA 98032 November 15, 2019 City of Renton, Department of Community & Economic Development 1055 South Grady Way Renton, WA 98057 RE : Variance for overhead installation of communication lines and facilities To whom it may concern, This letter is being sent as a revised application for a variance to the undergrounding requirements found in Renton Municipal Code (RMC) 4-6-090 subsection C which states that “All new electrical or communication facilities shall be required to be installed underground”. CenturyLink is applying for this aerial variance with proposed re-use of an existing aerial route due to the build costs of an underground design outweighing the general welfare consideration implicit with new underground installation : 1. Underground construction would be far more intrusive and cause a greater disturbance to local residences & businesses, when considering noise, duration of work, and pedestrian and vehicle traffic. 2. Placement and overlash of a new fiber optic cable to existing aerial facilities will not cause an adverse impact to residents. The aerial construction will be complete within a couple of days and CenturyLink will clean overlashed spans as necessary. In comparison, it can take up to a couple weeks to complete all placement and restoration with new underground construction. 3. Construction of new underground facilities poses greater risk to existing underground utilities within the work area – such as other telecommunications providers, sanitary sewer, storm sewer, water, and gas facilities. 4. The cost for new underground construction would be more than double the cost for overhead facility placement. With the approval of the variance, CenturyLink will commence with the coordination and implementation of overhead facility installation and traffic control as required to ensure public safety. CenturyLink and its contractors agree to follow the requirements and standards provided by the City of Renton to make certain the safe and efficient installation of the proposed facilities. If you have any further questions or concerns regarding this project, please contact Jesse Patjens at 425-429-5722 or Jesse.Patjens@CenturyLink.com. Sincerely, Jesse Patjens Local Network Engineer Field Operations & Network Implementation CenturyLink December 11, 2019 Stephen Stuart Qwest Corp d/b/a CenturyLink 23315 66th Ave S Kent, WA 98032 Via Email: stephen.stuart@centurylink.com SUBJECT: Request for Undergrounding Exemption (N.550179, MFP19006164, 616 W Perimeter Rd) Dear Mr. Stuart: The City of Renton has reviewed your request to grant CenturyLink an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. CenturyLink proposes to have North Sky Communications overlash approximately 515 lineal feet of new 72-count aerial fiber to existing Puget Sound Energy (PSE) power poles beginning at the pole on the west side W Perimeter Rd and to the southwest of the building at 600 W Perimeter Rd. Overlashing will continue North along the west side of W Perimeter Rd for 515 lineal feet before ending at the pole to the west of the building 608 W Perimeter Rd. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. City of Renton Municipal Code 5-19-2.B.1 and 2 states that “Except as otherwise provided herein, any telecommunications carriers who desire to construct, install, operate, maintain, or otherwise locate telecommunications facilities in, under, over or across any public way of the City, and to also provide telecommunications service to persons or areas in the City, shall first obtain a franchise granting the use of such public ways from the City pursuant to Section 5-19-3 of this Chapter.” CenturyLink does not have a franchise agreement with the City, as its predecessor-in-interest held a blanket grant of authority, dating back to territorial times, and therefore has unique status as compared to other telecommunications purveyors. Per Eric J. Schwalb, Senior Corporate Counsel for CenturyLink, RCW Section 35.99.030 states that a city or town may not require a “master permit” from service providers seeking access to public rights-of-way who have an existing statewide grant, as Century Link has. Furthermore, the Washington State Constitution, Article XII, Section 19, grants the right to construct and maintain lines of telegraph and telephone within this state. While we concur that VOIP is allowed per the RCW and Washington State Constitution, cable service is not a right granted without a franchise. Therefore, this analysis will focus on the overhead fiber proposed to be installed for Data/VOIP, and not the provision of future cable. CenturyLink N.571919 Page 2 of 2 December 11, 2019 In addition, staff considered RMC 4-6-090.D. which allows for exemptions due to technological difficulties; when costs outweigh the general welfare consideration implicit in underground installation; or, if the growth pattern of the area has not been sufficiently established to determine the ultimate service routes. In this instance, the portion of the route proposed for aerial installation is in an area where cost to underground one utility service will be cost prohibitive. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant for the Project Reach is approved with conditions subject to the conditions below as the request complies with exemption criteria of RMC 4-6-090(D)(1)(i) ii. Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Century Link’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Century Link shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, December 27, 2019. Sincerely, Brianne Bannwarth, PE Development Engineering Manager cc: C.E. “Chip” Vincent, CED Administrator Gregg Zimmerman, PW Administrator Jennifer Henning, Planning Director Justin Johnson, Assistant Development Engineering Manager Scott Warlick, Engineering Specialist II Holly Powers, Permit Technician Jesse Patjens, CenturyLink Jesse.Patjens@CenturyLink.com Amy Silbaugh, CenturyLink amy.silbaugh@centurylink.com Franchise Permits DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP19006164 Engineering 1 Engineering General Conditions The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Century Link’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Century Link shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City, from the first event triggering the requirement to underground the aerial lines. 2 Engineering General Conditions A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 3 Engineering General Conditions Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 4 Engineering General Conditions Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. Page 1 of 1