Loading...
HomeMy WebLinkAboutC_Cover Letter 711 Renton_200114_v1 January 14, 2019 Electronic Submittal City of Renton Department of Community and Economic Development Planning Division 1055 South Grady Way Renton WA 98057 RE: Application for SEPA Environmental Review 7-Eleven UST Replacement 1105 SE 168th Street, Renton, W ashington 98055 APN: 289260-0051 7-Eleven No. 14441 / Our Job No. 20224 On behalf of our client, 7-Eleven Inc., Barghausen Consulting Engineers, Inc. (Barghausen) is pleased to submit the required application forms, plans, and supporting documentation necessary to initiate SEPA Environmental Review for the tenant improvement affecting the facility referenced above. Scope of Project The Applicant's proposal will require the removal of three (3) 12,000-gallon underground storage tanks (USTs) currently on site and the installation of two (2) replacement USTs, one (1) 15,000-gallon UST for the storage of regular unleaded fuel and one (1) 15,000-gallon split/dual UST for the storage of diesel fuel (8,000 gallons) and premium unleaded (7,000 gallons). Project elements related to these improvements include the following:  Removal of the concrete slabs covering the existing tanks and the drive slab beneath the fuel canopy  Excavation and removal of the existing USTs  Removal of the dispensers, including the existing fuel pump islands  Removal of the existing fuel distribution system. Sawcutting and trenching to accommodate the installation of new piping and conduits  Install new USTs, turbines, and vent box/risers  Install new dispensers  Install new sensors, electrical panel, breakers, wiring and intercom system City of Renton Department of Community and Economic Development Planning Division -2- January 14, 2020  Install air/water unit  Replace concrete slabs and patch asphalt to match existing pavement Submittal Package After consultation with Renton staff and In accordance with published submittal requirements for the Environmental Review Process, Barghausen has prepared a submittal package including the following: 1. One (1) copy of the Environmental Review Submittal Requirements Checklist 2. One (1) copy of the Pre-Application Meeting Summary 3. One (1) copy of the Waiver Form provided by city of Renton staff 4. One (1) copy of the Master Land Use Permit Master Application Form, completed, signed, and dated 5. One (1) copy of the Comprehensive Project Narrative 6. One (1) copy of the SEPA Environmental Checklist prepared by Barghausen Consulting Engineers, Inc. dated December 24, 2019 7. One (1) copy of the Construction Mitigation Narrative addressing various construction activities, operational issues, and noise abatement 8. One (1) copy of the Neighborhood Detail Map 9. One (1) copy of Sheet C2.0 of the Civil Site Plan prepared by Barghausen Consulting Engineers, Inc. 10. One (1) copy of the Survey 11. One (1) copy of the Geotechnical Report prepared by Stantec Consulting Services, Inc. dated September 18, 2019 12. One (1) set of the Civil Plans prepared by Barghausen Consulting Engineers, Inc. 13. One (1) copy of the Stormwater Pollution Prevention Plan (SWPPP) 14. One (1) copy of the Technical Information Report (TIR) 15. One (1) copy of each of the following Colored Maps for Display: Neighborhood Detail Map (see Item 10, above) and Site Plan 16. One (1) copy of Documentation provided from Soos Creek Water and Sewer District confirming the project site is connected to water and sewer service City of Renton Department of Community and Economic Development Planning Division -3- January 14, 2020 Please contact me at (425) 251-6222 or at phopper@barghausen.com if you have any questions or need additional information. Thank you. Sincerely, Pat Hopper Project Planner PH/lb 20224c.docx enc: As Noted cc: Georgina Davila, 7-Eleven, Inc. Stephanie Wood, Imagine Commercial Solutions, Inc. Chris Jensen, Barghausen Consulting Engineers, Inc. Nick Wecker, Barghausen Consulting Engineers, Inc.