Loading...
HomeMy WebLinkAboutzS-4012SetN T 0 i W z LU 0 rQ V J_ rr LU G 10 5 0 10 20 SCALE IN FEET KEY NOTES: DETAIL/ KEY NOTE: SHEET 0 PROTECT EX GREASE INTERCEPTOR, MUST REMAIN IN - SERVICE DURING CONSTRUCTION OTRANSFORMER LOCATION, COORDINATE WITH PSE - ADJUST EX JBOX TO FINISHED GRADE. VAULT COVERS SHALL WITH DOWNTOWN COR STD OCOMPLY STREETSCAPE STANDARDS. SEE PLAN 102.1 VAULT COVER NOTES ON SHEET C09. EX JUNCTION BOX AND OPROTECT ADJUST TO FINISHED GRADE - UG ELECTRICAL SERVICE TO OTRANSFORMER. ROUTING IS APPROXIMATE- SEE PSE DRAWING #101113708 EX 1 1/2" WATER SERVICE HAS O6 BEEN INACTIVE FOR SEVERAL YEARS PER COR (ACCOUNT NO - 000743-000). ABANDON EX SERVICE AND SALVAGE METER TO COR 07 EX PSE VAULT TO REMAIN - LIGHTING JUNCTION BOX OSTREET 8 AND CONDUIT (TYP) E1.0-E4.0 OREMOVE CLEANOUT AND CAP EX SSS AT BACK OF CURB - STA 2+12.89, REPLACE EX SIDE SEWER FROM CLEANOUT TO BUILDING AND ANY PORTION THAT IS NOT 6" DIA PVC. SS1/C14 10 CONTRACTOR TO POTHOLE EX SSS (COR STD AND NOTIFY ENGINEER IF 2.00% PLAN 403.1) SLOPE FROM BUILDING PLUMBING CONNECTION CANNOT BE MAINTAINED 6" IE ±37.50 AT BUILDING 11 RETIRE EX GAS SERVICE AT MAIN, COORDINATE W/ PSE - REMOVE EX FIRE SERVICE VAULT AND INTERIOR PIPING INC. 1" 12 DOMESTIC SERVICE. RETURN 1" - METER TO CITY WA2/C 12 13 FIRE HYDRANT ASSEMBLY (COR STD PLAN 310.1) ADJUST EX JBOX TO FINISHED 14 GRADE 15 REMOVE EX CLEANOUT - 3" DOMESTIC SERVICE CONNECTION. REQUIRED DCVA WA1/C12, LOCATED INSIDE BUILDING. WA3/C12 16 POTHOLE EX GAS MAIN PRIOR TO (COR STD TRENCHING FOR WATER SERVICE PLAN 300.1, AND NOTIFY ENGINEER IF THERE IS 320.4) A CONFLICT WITH METER VAULT A5 17 6" FIRE SERVICE CONNECTION. STD (C STD DDCVA LOCATED INSIDE BUILDING PLAN STANDPIPE FIRE DEPARTMENT 18 CONNECTION. 3.0' CLEAR (MIN) - REQUIRED IN ALL DIRECTIONS WA5/C 13 19 FIRE LINE POST INDICATOR VALVE (COR STD PLAN 360.5) LEGEND: CONCRETE SIDEWALK ASPHALT PAVEMENT 1 2" IRRIGATION SERVICE TO BE INSTALLED BY CITY FORCES. CONTRACTOR SHALL PROVIDE ALL EXCAVATION AND EXPOSE THE 20 WATER MAIN AND ALSO DIG THE TRENCH FOR THE NEW SERVICE WA7/C18 (COR STD LINE FROM THE MAIN TO THE PLAN 320.2) METER. DCVA TO BE LOCATED IN WATER/FIRE ROOM. IRRIGATION SERVICES WILL IRRIGATE PRIVATE PROPERTY AND STREET TREES 21 EX STREET LIGHT TO BE REMOVED EC1.0-EC4.0 AND REPLACED 22 PROTECT EX WATER SERVICE - 23 STA 2+34.71 NEW GAS SERVICE AND METER, - COORDINATE WITH PSE SS2/C14, STA 1+28.18 24 NEW 6" SSS @ 2.00% MIN SLOPE, STD (COR STD W/ NEW CONNECTION TO MAIN PLAN 6" IE ±37.50 AT BUILDING 406.0 0 NEW SSCO #1 STD (COR STD RIM TO FINISHED GRADE PLAN 26 STREET LIGHTING CONDUIT (TYP) E1.0 - E4.0 27 NEW SSCO #2 STD STD (COR RIM TO FINISHED GRADE PLAN 28 ±25 LF 6" DI PIPE - STA 2+20.40, 9.45' LT WA1/C12, 29 12" X 6" TAPPING TEE (MJxFL) 6" TAPPING VALVE (FLxMJ) WA4/C13 (COR STD W/ CONIC THRUST BLOCK PLAN 300.1, ±25 LF 6" DI PIPE TO HYDRANT 330.2) STA 2+26.82, 9.45' LT WA1/C12, 12" X 4" TAPPING TEE (MJxFL) WA4/C13 30 4" TAPPING VALVE (FLxMJ) (COR STD W/ CONIC THRUST BLOCK PLAN 300.1, +27 LF DI PIPE TO METER 330.2) STA 2+30.29, 9.45' LT WA1/C12, 31 12" X 6" TAPPING TEE (MJxFL) 6" TAPPING VALVE (FLxMJ) WA4/C13 (COR STD W/ CONIC THRUST BLOCK PLAN 300.1, ±40 LF 6" DI PIPE TO PIV 330.2) PLUG EX 6" VALVE WITH 6" PLUG 32 (MJ) BY CITY FORCES. CONTRACTOR TO EXCAVATE AND - RESTORE ROADWAY. CAP EX 6" SERVICE DOWNSTREAM OF VALVE 22.5 OR 45 DEG BEND W/ CONIC WA4/C13 BLOCKING PER COR STD PLAN WA6/C13 33 330.2. BEND LOCATION AND ANGLE (COR STD TO BE FIELD DETERMINED IN PLAN 330.2, ORDER TO ACHIEVE CLEARANCE 330.3) FROM EX UTILITIES 22.5 OR 45 DEG BEND W/ CONIC WA4/C13 BLOCKING PER COR STD PLAN WA6/C13 34 330.3. BEND LOCATION AND ANGLE (COR STD TO BE FIELD DETERMINED IN PLAN 330.2, ORDER TO ACHIEVE CLEARANCE 330.3) FROM EX UTILITIES ELECTRICAL DUCT BANK (NOT 35 SURVEYED- LOCATION IS - APPROXIMATE) CENTURYLINK DUCT BANK (NOT 36 SURVEYED- LOCATION IS - APPROXIMATE) CONIC THRUST BLOCK FOR 4", 90 37 DEG BEND DOMESTIC METER BYPASS POST 38 INDICATOR VALVE UTILITY AND RESTORATION NOTES: WATER METER VAULT 1. PAVEMENT RESTORATION SHALL MEET THE CITY OF RENTON STANDARD TRENCH AND STREET OVERLAY STANDARDS. 2. UNDERGROUNDING OF ALL UTILITIES IS APPLICABLE. 3. MINIMUM VERTICAL SEPARATION BETWEEN UTILITIES AT CROSSING IS 12 ` ' LANDSCAPE INCHES. CROSSINGS LESS THAN 12 INCHES REQUIRE ETHAFOAM BLOCKING. 4. CONTRACTOR TO POTHOLE EX GAS MAINS AT LOCATION OF PROPOSED UTILITY CROSSING # STORM DRAIN, SIDE SEWER AND WATER SERVICE CROSSINGS AND SEE TABLE THIS SHEET REPORT TO ENGINEER IF CROSSINGS AS SHOWN ARE NOT FEASIBLE. BASE MAP/TOPOGRAPHY PROVIDED BY Gqe OTHERS. DCG CANNOT BE HELD LIABLE 9706 4th Ave NE Suite Seattle, WAA 98115 o�NoFW \� f'ga ne C9 �Ison Ti - belei FOR ACCURACY. CONTRACTOR SHALL FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & P: 206.523.0024 F: 206.523.1012 www.dcgengr.com e: Q:� �0� RFoiaT6�0 8 �`SS/ONAL ' CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT DCG PRIOR TO CONSTRUCTION. 2 C❑NSTRUCTI❑N RECORD DRAWINGS CT 01/08/20 1 P❑ST-PERMIT REVISI❑N- UTILITY C❑NFLICT CT 01/25/19 NO. REVISION BY DATE CONSTRUCTION RECORD DRAWING: THIS SHEET CONTAINS AS -BUILT INFORMATION. MINOR REVISIONS ARE SHOWN BY STRIKING THROUGH THE ORIGINAL TEXT AND DENOTING THE AS -BUILT INFORMATION ADJACENT. OTHER REVISIONS ARE DENOTED BY REVISION CLOUDS. AS -BUILT INFORMATION WAS SURVEYED BY D.R. STRONG AND SUPPORTING PHOTOS AND DOCUMENTATION WAS PROVIDED BY SRM (CONTRACTOR). DCG IS REPONSIBLE FOR NOTATING THE AS -BUILT INFORMATION ON THE DRAWINGS BUT IS NOT RESPONSIBLE FOR THE ORIGINAL AS -BUILT DATA PROVIDED TO DCG. SURVEYED: SCALE: AS NOTED VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M DESIGNED: CT DRAWN: RB/CT ONE INCH CHECKED: TG AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY P P R APPROVED: TG CB, SOLID LID TOP=39.52 I.E. 8"PVC(N)=36. I.E. 8"PVC(S)=36. 30LID LID =39.43 r'PVC(N)=35.8 r'PVC(S)=35.8 3"PVC(W)=35.18 IH, TOP=39.34 S"PVC(E)=35.2 3"PVC(S)=35.1 3"PVC(N)=35.1 OR TOP=39.89 _L OF WATER, ES NOT VISIBLE R. CHNL.(N-S)=35.4 {, TOP=38.84 . 8"CONC(W)=37.3 1, TOP=39.36 CONC(E)=37.4 PVC(W)=36.9 >."CONC(S)=35.3 2"CONC(N)=35.1 11-1FU 1 LU I IN COMPLIANCE WITH CITY OF RENTON STANDARDS CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) Aomttk C TY OF MERRILL GARDENS AT RENTON CENTER- ADDITION %R1waoR E N TO N 104 BURNETT AVE S, RENTON, WA 98057 Planning/Building/Public Works Dept. COMPOSITE UTILITY PLAN 1 /8/20 PAGE: DRAWING NO: C06 SHEET: 6 OF: 34 CU z LU 0 Q 0 J_ LU G N T C) I W I— U) Z LU 0 rr Q J_ Ir LU 2 RECESSED LIFT POCKET O-1/2" 11" —� 12-1 f4"� CAST IRON RINQ AND Not to Scale FRAME 91-nrI nw>Lrrro 1��1,1 1 NOTLSi_ 1. 8" AND 6" CLEAN -OUT RINGS AND COWERS ON SEWER MAINS SHALL BE EAST JDRDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) DR APPROVED EQUAL, CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-D" SQUARE CONCRETE, CLASS 30120, PAD AROUND THE RING AND COVER. OR DABLE CLEANOUT STD_ PLAIN - 403.1 ~ PUBLIC WORKS 8" OR f" CLEANOUT APPROVED; DEPARTMENT FOR SANITARY SEWER MAIN YA Gn!A it n ti 0"hnc 4Y9 H n n� � 8" OR 6" CLEANOUT FOR SANITARY SEWER MAIN SS1 NOT TO SCALE C06 ,4 W. G 9706 4th Ave NE O of WAsf Suite 300 �/1 Digi Seattle, WA 98115 C) P: 206.523.0024 r F:206.523.1012 �0 47202 www.dcgengr.com AONAL BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE ed FOR ACCURACY. CONTRACTOR SHALL y FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & in CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE 8'00 CONSTRUCTED AS SHOWN, CONTACT DCG PRIOR TO CONSTRUCTION. 47 BEND AS REQUIRED (NCI MARE THAN 45• BEND.). EVERY RND CHANGE IN DIRECTION OR GRADE WILL REQUIRE A SURFACIE CLEANOUT WYE. (SEE NOTE 11) H-OUSE 4" CLEANDU T WYE WITH 45' BEND AND PLUG. (SEE NOTE 11) w w J � HOUSE q a d SURFACE CLEANOUT 6"x 6"x6" WYE CSEE STD PLAN -- 407) PRQPERTY LIME -Z I z MAIN SEWER LINE iiiiiihi 4" SURFACE 1 CLEANDUT WYE 4" WYE WITH CLEANGUT UP ALL 9Q' TURNS SHALL BE ACCOMPLISHED - BY MEANS 9F A VVYE MTH CLEANOUT AND 45' BEND. TWO 45' BENDS SHALL NOT BE ACCEPTABLE_ (SEE NOTE 11) 1 Lo 2 HOUSE a_ 3LD" WIN. 4" SEWER PIPE {T'�IOAL} 4" TEST TEE WITH PLUG FACE UP (TYPICAL) j 6"x 4 REDUCER � (TYPICAL) HOUSE 4" SEWER PIPE, SEE NOTES 2 AND 3. MINIMUM LIN£ SIZE FOR OTHER THAN SINGLE FAMILY IS B" PROPERTY ONE NOTES - IF THE BUILDING 5EWER SERVES ANY FIXTURE HAVfNC 1. Pr1ar to lnstallat'on of a sanitary sewer connection, o sfde-sewer x FLOOD LEVEL R1M5 LOCATED BELOW THE ELEVATION psrmlt must tre purchased from the City Qf Rentprl Public Works M M(4" OF THE NEXT UPSTREAM MANHOLE COVER OF THE Depairtment, UPU2LIC SEWER SYSTEM, A BACKFLOW PREVENTION "t7 zDEVICE SUCH AS CLEAN CHECK EXTENDABLE 1 51BACKWATER VALVE Off APPROVED EQUAL S4A�LL G1 2. Types of pipe and fittings that can be used For sanitary sewers INSTALLED. sh❑II be approved l y the Department of Pudic Works. Rubber of neoprene gcskets as specffled by the manufacturer, shall be 4" FLEXIBLE COUPLING (1=ERNCO OR EQUAL) used r�rr joints. J A minimum grade of 29 (1/4"' per toot) must be mcintolned SURFACE CLCLEANOUT3. 4"x 4"x4" WaE with 4" pipe_ In the evient a 27 grade cannot be maintained, the PIPINC owner must sign a City of Renton grade release form and then can install 6` pips of ❑ grade of 1%. PLAN BUILDING DRAIN FOR 4, For inspection of side sewer, call 24 hours in advance_ The LOW ELEVATION HOUSE inspection prone number is on the sfde sewer permik. Site must be ready for inspection on-i representative on sit* when inspector arrives of appointed time. Side sewer an.d stub shall be tested p-er Cfty speefileo#lords. Make the connection at the h D t b kf;ll th 1*;t 11 M1' b th MAIN TO PROPERTY LINE V-0" 5-0 ruse, " no ac I +v I c "INapprorva IS giver. y B PROPERTY LIME FROM THE HOUSE BUILDING DRAIN . inspector. Final approval will be granted after the existing septic SIDE SEWER BUILf]INC SE JFR 2._B., tank has been pumped out ❑nd filled with sand. L TO 3.�0., r 3'-0"MIN. 5. Install side 5uwcr with 2' minimum cover. 18" Gover iz allowed { at the douse if outlet is shallow. 5. It side sewer stub Is not ovoiloble. The owner shall be C"' mrn Ln 41 L r, 1# � responsible for 'its instollat;on per standard drowrnq 405_1. All LJ 1-`,a1 W Z m °' x o x � rn work within street right-af-way sh-all be done by a licensed and oa 0- ^> � C n z nF- 0 4 � m m" z � " - -� 1Ex r1., n rn bonded contractor. rrI Q-Z ran 0 � rn r rn r O C � W C m � x. II Z C)* m 0 ?C r P, 0 z n m � 7. All work shall be accomplished in accordance with the Washington cn-4 r- 0;� LA n r m C -q x. z 0 > n F rrn � rn rn Industrial Safety and Health Att. (VASNA) Z rrcl w 3 rrrl rQ cn0Q = — n, Q b Iti a z 0 I� Va Q S. All french rentoratlon for side sewers in [he puhflc rlqht nt- war 3q. v m a .r. r small conform to the most current trench restarcution C31 a, D - rr1 0 requirement€ as in the Rentoul Skandafd Drawings. �. x to rn - Z Q 0. z n 0 9. All building sewer and side sewers shall have bedding in x" Lao urcordonce with standard druwin.g 405. COCA g Cq -ate rri 10. There shall be n rninfrnurn 10 foot horizontal sepflratibn between rn v O. TI -u sanitrory side sewers and water services and a rnininnurn 5 foot _ horizontal separation between sanitary side sewers and all other rn utlli#ies. 11. Thee cleonoul at the Right -of -Way shall be installed per CALL FOR LOCATIONS KrORE YOU DIG Standard Plan 07. The cleanout of the building shall be 48HR LOCATORS 1-800-424-5555 installed to surface grade. All other cieonouts shall he installed to within 12" of the sur#dce. y TYPICAL BUIL13ING SEWER STD. PLAN— 406.2 `1 PUBLIC AR WORKS FROM LINE TO DEPARTMENT ,# BUILDING CONNECTION AUGUST 2DI3 TYPICAL BUILDING SEWER FROM PROPERTY LINE TO BOLDING CONNECTION rS S 2 NOT TO SCALE C06 EX. SEWER MAIN PROPERTY LINE SPOOL (LENGTH AS INEEOED) Z` � I I 6" 5E11'!ER STUBE FUTURE 4" SIPE SEWER • I 2"x 4" STUD MARKING POST PAINTED SEi' FR MAIN TEE X 5" TEE a" CAMP V41 WA Tl TH THE WORD W SEWER STENCILED IN 3" HIGH ULACK LETTERS AND #6 WIRE z I WRAPPED AROUND THE STUD AND E)(TENDED TO THE TOP OF THE STUD. I i COUPLING (TYP.) t i4 a __T_- ___,-__-_- -- ------,_ r- ----.� L __ _J BEND AS y REQUIRED 6"X,5'X5' SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO, 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID). (SEE STD. PLAN 403.1 FOR INSTALLAT ON) Jib EAGLE THREADED CLEAN --CUB' ADAPTER HUE1 & PLUG (OR APPROVED EQUAL) -LXIST1NG SAAJITARY SEWlER MAIN---2.07- MIN. SLOPE FUTURE 4" SIDE SEWER �B" SEWER 5TLJO 5"K5']t6' WYE FUTURE Vx 4" REDUCER SEWER MAIN SIZE ?(6•, TEE F I A. 'ATRIFIED CLAY MAW - CUT IN A NEW PVC "TEE' USING 'STRONG -BACK' FLEXIBLE COUPLINGS (FERNC❑ OR AIPPROYED EQUAL). B. CONCRETE MAIN - GUT IN A NEW PVC 'TEE" USING "STRONG -BACK- FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC dr C9C0 PVC MAIN - CUT IN NEW TEE: US= RIGID COUPLINGS OR OCRE-()BILLED WTH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPRGVED EQUAL) E. MANHOLE CONNECTION - ALt, CONNILOT1ONS TO MANH%C-S SHALL RE AT MANUFACTURED KNocx-a41T i OR THE STRUCTURE SHALL IBE CORE -DRILLED. 3000 PS mix R CONCRETE +• -�CtiCk low.G 2% M11"_IDPE HORIZONTAL TEE t5" MIN. SEWER SEWER AGAIN VAIN CONCRETE BLOCKING ANGLE NOTE: JISL.ESS OTHERVOSE SHOWN ON PLAN, 51DE SEWER SHALL HAVE A MININfUhI 2.5' CCVER AT PROPEIRT1' UNE OR ]-5' LOWER THAN THE LOWLSt HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER STD. PLAN ,406.1 PUBLIC WORKS�t DEPARTIVIENT INSTALLATIONpw m 41)-c (SEINER MAIN TO PROPERTY LINE) � o�n 0 •ykYc rih�711 STANDARD SIDE SEWER INSTALLATION SS3 NOT TO SCALE �O6 R-401201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W, CALL 811 (2) BUSINESS DAYS W BEFORE YOU DIG LU (UNDERGROUND UTILITY 12� LOCATIONS ARE APPROXIMATE) < SURVEYED: SCALE: DATE: VERTICAL: NAVD 1988 DESIGNED: 1 /8/20 AS NOTED HORIZONTAL: NAD 1983/1991 C TY OF MERRILL GARDENS AT RENTON CENTER- ADDITION CT C - C FIELDBOOK: DRAWN: RENTON 104 BURNETT AVE S, RENTON, WA 98057 PAGE: Ir 2 C❑NSTRUCTI❑N RECORD DRAWINGS CT 01/08/20 RB/CT • DRAWING No: 1 P❑AT FULL SCALE PanninST-PERMIT REVISION- UTILITY CONFLICT CT 01/25/19 CHECKED: ONE INCH DATUM g/Buidin g/Public Works Dept. CITY DETAILS- SEWER C14 LU TG IF NOT ONE INCH N 0. REVISION BY DATE APPF APPROVED: TG SCALE ACCORDINGLY SHEET: 14 OF 34