Loading...
HomeMy WebLinkAboutcopy-approved-water-plans-W-4067.pdf0+001+002+003+004+005+00T STA:0+13.31, 0.00'LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STA:1+14.64, 0.00'LT 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:1+14.63, 21.64'LT CENTER FIRE HYDRANT ASSEMBLY STA:4+04.45, 0.02'LT 1-10"x6" TEE (FLXFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLXMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:4+04.23, 19.85'LT CENTER FIRE HYDRANT ASSEMBLY STA:4+25.14, 0.01'RT 1-45° BEND 1-CONC. THRUST BLOCK STA:4+39.07, 0.03'RT 1-45° BEND 1-CONC. THRUST BLOCK STA:7+78.67, 0.04'RT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:7+94.56, 0.00'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:8+16.02, 0.01'LT 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:8+16.02, 22.98'LT CENTER FIRE HYDRANT ASSEMBLY STA:11+80.72, 0.02'RT 1-10"X6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1- FIRE HYDRANT ASSEMBLY 1-CONC THRUST BLOCK STA:11+80.73, 30.37'LT CENTER FIRE HYDRANT ASSEMLBY STA:11+47.81, 40.06'LT 1-FDC (FL) STA:0+00.00 N:166811.9796 E:1297757.2602 STA:4+99.97 N:167311.6912 E:1297773.2683 STA:3+51.78, 29.03'RT ABANDON AND CAP EXISTING 34" WATER SERVICE. (BY CITY FORCES) STA:12+38.78, 0.00'LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS WALKER MAZDA DEALERSHIP REFER TO WATER PROFILE 1 REFER TO WATER PROFILE 2 REFER TO WATER PROFILE 3 N1° 50' 05"E500.00'0+00 1+00 2+00 3+00 4+00 5+006+007+008+009+0010+0011+0012+0012+45 3 C4.2 6" DDCVA 3 C4.2 STA:3+96.95, 0.00'LT 1-10"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THURST BLOCK STA:3+96.95, 91.08'RT 1-10" CAP (MJ) 1- 2" TEMPORARY BLOW OFF ASSEMBLY PER STD PLAN NO.340.20 1- CONC. THRUST BLOCK 1" IRRIGATION METER 1" DCVA 3" RPBA TO BE INSTALLED INSIDE FIRE SPRINKLER RISER ROOM PER PLUMBING PLANS STA:11+26.19, 129.61'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK STA:12+03.59, 52.19'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK 105 LF 2" PRIVATE WATER SERVICE PIPE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 EAST VALLEY ROADMATCH LINE WATER MAIN STA: 5+75.00 MATCH LINE WATER MAIN STA: 11+00.00 1 C4.5 NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) ELEV:230.75 VERTICAL DATUM NAD 1983 WASHINGTON STATE PLANE NORTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. VERIFIED CITY OF RENTON 230 (CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE CUL DE SAC) BASIS OF BEARING WATER PLAN C4.1 20 PROVIDE PAVEMENT PATCH AS REQUIRED PER CITY OF RENTON STD. PLAN 110 PROVIDE PAVEMENT PATCH AS REQUIRED PER CITY OF RENTON STD. PLAN 110 15.00' EASEMENT 15.00' EASEMENT 21.50' EASEMENT 3 C5.3 2 C4.2 2 C4.2 2 C4.2 3 C5.3 1 C4.3 1 C4.4 1 C4.5 REFER TO FIRE SYSTEM PLAN 1 C4.2 W-406701WTR-40-4067ADJUST EXISTING HYDRANT TO FINISH GRADE OF NEW 8 FT PLANTER STRIP. INSTALL NEW HYDRANT IF HYDRANT RELOCATION IS REQUIRED TO CLEAR NEW SIDEWALK. ADJUST EXISTING HYDRANT TO FINISH GRADE OF NEW 8 FT PLANTER STRIP. INSTALL NEW HYDRANT IF HYDRANT RELOCATION IS REQUIRED TO CLEAR NEW SIDEWALK. 1 C4.7 2 C4.5 2" DOMESTIC WATER METER 3 C4.5 2 C4.6 2 C4.6 ENVIRONMENTAL NOTES BILL KANE WITH ECO COMPLIANCE CORPORATION SHALL BE AVAILABLE DURING ONSITE WATER LINE EXCAVATIONS TO ENSURE THE TRENCH IS FREE FROM CONTAMINATED SOILS. ANY CONTAMINATION THAT EXCEEDS CLEAN-UP LEVELS SHALL BE REMOVED AND HAULED TO AN APPROVED OFFSITE DISPOSAL FACILITY. SOILS SHALL BE REPLACED WITH CLEAN BEDDING AND BACKFILL FOR WATER LINE TRENCHES. CLEAN BACKFILL MATERIALS FROM AN APPROVED SOURCE SHALL BE USED FOR ALL TRENCH BACKFILL AROUND WATERMAINS. WHERE WATER MAIN UTILITY EXCAVATIONS EXTEND BELOW THE EXISTING FILTER FABRIC LAYER SEPARATING STRUCTURAL FILL FROM NATIVE SOILS A NEW FILTER FABRIC SHALL BE LAID ALONG THE TRENCH BOTTOM AND SIDES PRIOR TO PLACEMENT OF BEDDING AND BACKFILL MATERIAL. BILL KANE CONTACT: 206-715-1396 BILL@ECOCOMPLIANCE.BIZ 07/30/2019 STA:12+03.59, 0.02'RT 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLx MJ) 1- DOUBLE CHECK DETECTOR ASSEMBLY 1-POST INDICATOR VALVE 1-CONC. THRUST BLOCK STA:11+80.72, 0.02'RT 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA:11+80.73, 30.37'LT CENTER FIRE HYDRANT ASSEMBLY STA:12+03.60, 44.69'LT CENTER POST INDICATOR VALVE STA:4+22.96, 105.20'RT CENTER FIRE DEPARTMENT CONNECTION STA:12+38.78, 0.00'RT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STA:12+03.59, 52.19'LT 1-45° BEND (MJ) 1-CONC. THRUST BLOCK25 LF 6"Ø DI PIPE25 LF 6"Ø DI PIPE30 LF 2"Ø PVC PIPE23 LF 10"Ø DI PIPE 20 LF 10" DI PIPE 10 LF 10" DI PIPE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 FIRE SYSTEM PLAN C4.2 21 N FIRE PROTECTION NOTES THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM, INCLUDING HYDRANT LOCATIONS, MAY DEVIATE FROM THE SYSTEM SHOWN. THE FINAL DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHALL. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 2 NOT TO SCALE FIRE HYDRANT ASSEMBLY 3 NOT TO SCALE DDCVA WITH STANDPIPE1SCALE: 1' = 10" FIRE SYSTEM ENLARGEMENT 6" DDCVA SEE DETAIL FOR INTERNAL PLUMBING 1" IRRIGATION METER 44' EASEMENT 21.50' EASEMENT 3 C4.2 3 C4.2 2 C4.2 W-406702WTR-40-40671" DCVA2 C4.5 4 C4.5 07/30/2019 10 15 20 25 20.120+5020.9321.131+0020.8620.921+5020.9921.042+0021.0421.042+5021.1221.123+0021.0120.993+5021.1621.184+0021.0820.774+5020.7920.845+0020.8720.775+5020.7320.763.0' COVER STA 1+14.64, 0.00'LT 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA: 4+04.45, 0.00'LT 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA: 4+25.14, 0.00'LT 1-45° BEND 1-CONC. THRUST BLOCK STA:4+39.07, 0.00'LT 1-45° BEND 1-CONC. THRUST BLOCK STA: 0+13.31, 0.00' LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STORM CROSSING STA: 1+69.76 IE: 15.05STORM CROSSING STA: 0+61.60 IE : 14.15 3.4' COVER 1.50' 1.5' 3.0' COVER FILL AND COMPACT PARKING LOT TO FINISH SUBGRADE PRIOR TO EXCAVATION FRO INSTALLATION OF NEW WATER MAIN STA: 3+96.95, 0.00'LT 1-10"x10" (MJxFL) 1- 10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK 23 LF 10" DI CL52 @ 0.00% 36 LF 1 0 " DI C L 5 2 @ 5. 2 0 % 293 LF 10" DI CL52 @ 0.00% 26 LF 10" DI CL52 @ 2.20% 339 LF 10" DI CL52 @ 0.00% 50 LF 10" DI CL52 @ 0.00% 13 LF 10" DI CL52 @ 0.00% 10 15 20 25 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 FINISHED GRADE AT PIPE CENTERLINE EXISTING GRADE AT PIPE CENTERLINE EXISTING GRADE ELEVATION FINISHED GRADE ELEVATION WATER PROFILE C4.3 22 1 SCALE: 1"=20' HORIZONTAL 1"=2' VERTICAL WATER MAIN PROFILE STA 0+00 TO 5+75 W-406703WTR-40-406707/30/2019 5+5020.7320.766+0020.8220.896+5020.7820.657+0020.6420.507+5020.4320.628+0020.9321.068+5021.2821.479+0021.6621.799+5021.7121.7110+0021.7121.7710+5021.7121.7111+0021.71STA: 7+78.67, 0.00'LT 1-45°BEND 1-CONC. THRUST BLOCK STA: 7+94.56, 0.00'LT 1-45° BEND 1-CONC. THRUST BLOCK STA: 8+16.02, 0.02'LT 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK 1-FIRE HYDRANT ASSEMBLY STA: 10+20.27, 0.00'LT 2" COMMERCIAL WATER SERVICE 3.0' COVER 3.6' COVER FILL AND COMPACT PARKING LOT TO FINISH SUBGRADE PRIOR TO EXCAVATION FRO INSTALLATION OF NEW WATER MAIN FILL AND COMPACT PARKING LOT TO FINISH SUBGRADE PRIOR TO EXCAVATION FOR INSTALLATION OF NEW WATER MAIN 339 LF 10" DI CL52 @ 0.00%339 LF 10" DI CL52 @ 0.00% 16 LF 10" DI CL52 @ 0.00% 3 LF 10" DI CL52 @ 0.00% 28 LF 10" DI CL52 @ 2.00% 293 LF 10" DI CL52 @ 0.00% 293 LF 10" DI CL52 @ 0.00% 10 15 20 25 10 15 20 25 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 FINISHED GRADE AT PIPE CENTERLINE EXISTING GRADE AT PIPE CENTERLINE WATER PROFILE C4.4 23 1 SCALE: 1"=20' HORIZONTAL 1"=2' VERTICAL WATER MAIN PROFILE STA 5+75 TO 11+00 W-406704WTR-40-406707/30/2019 10 15 20 25 11+0021.7121.7111+5021.8421.1912+0020.5419.53STA: 11+80.72, 0.01'LT 1-10"x6" TEE (FLxFL) 1-6" GATE VALVE (FLxMJ) 1-10" ADAPTER (FLxMJ) 1-10" GATE VALVE (FLxMJ) 1-FIRE HYDRANT ASSEMBLY 1-CONC. THRUST BLOCK STA: 12+38.76, 0.00'LT CUT IN: (BY CITY FORCES) 1-12"x10" TEE (FLxFL) 2-12" GATE VALVES (FLxMJ) 1-10" GATE VALVE (FLxMJ) 2-12" SLEEVES (MJxMJ) 1-10" SLEEVE (MJxMJ) 1-CONC. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-IN OF VALVES AND FINAL CONNECTION WITH THE CITY OF RENTON SEE CITY STD PLAN NO. 300.4 FOR CONNECTION DETAILS STA: 12+13.32, 0.00'LT 2" IRRIGATION SERVICE STA: 12+03.65, 0.00'LT 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-DOUBLE DETECTOR CHECK VALVE ASSEMBLY(FL) 1-POST INDICATOR VALVE (FL) 1-CONC. THRUST BLOCK 3.0' COVER FILL AND COMPACT PARKING LOT TO FINISH SUBGRADE PRIOR TO EXCAVATION FOR INSTALLATION OF NEW WATER MAIN 293 LF 10" DI CL52 @ 0.00% 107 LF 1 0 " D I C L 5 2 @ 2 . 1 0 % 293 LF 10" DI CL52 @ 0.00% 10 15 20 25 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 FINISHED GRADE AT PIPE CENTERLINE EXISTING GRADE AT PIPE CENTERLINE WATER PROFILE C4.5 24 2 NOT TO SCALE DOUBLE CHECK VALVE ASSEMBLY 3 NOT TO SCALE REDUCED PRESSURE BACKFLOW ASSEMBLY 1 SCALE: 1"=20' HORIZONTAL 1"=2' VERTICAL WATER MAIN PROFILE STA 11+00 TO 12+50 W-406705WTR-40-40674 NOT TO SCALE 1 INCH WATER SERVICE Know what's below. before you dig.Call R 07/30/2019 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 WATER NOTES AND DETAILS C4.6 25 1 NOT TO SCALE WATER PLAN GENERAL NOTES 3 NOT TO SCALE POLY PIG STATION W-406706WTR-40-40672 NOT TO SCALE WATER MAIN CUT IN CONNECTION 07/30/2019 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 WATER NOTES AND DETAILS C4.7 26 1 NOT TO SCALE 1.5 AND 2 INCH WATER SERVICE 2 NOT TO SCALE VALVE BOX DETAIL 3 NOT TO SCALE THRUST BLOCKING W-406707WTR-40-406707/30/2019 TEAST VALLEY ROADSW 34TH ST0+00 1+00 2+00 3+00 4+00 5+00 STA:0+17.42 BEGIN FRONTAGE IMPROVEMENTS STA:4+75.47 END FRONTAGE IMPROVEMENTS T0+00 1+00 2+00 3+00 4+00 5+00 STA:0+17.42 BEGIN FRONTAGE IMPROVEMENTS STA:4+75.47 END FRONTAGE IMPROVEMENTS 0+00 1+00 2+00 3+00 4+00 5+00 STA:3+04.19, 26.35'RT STA:3+11.21, 25.11'RT STA:3+13.51, 24.36'RT STA:3+21.31, 23.10'RT STA:3+23.43, 23.10'RT STA:3+31.19, 24.33'RT STA:3+33.63, 25.13'RT STA:3+41.38, 26.36'RT CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 37 Know what's below. before you dig.Call RTED-40-4067C:19-002207LUA:18-000305PR:18000212R-4067 NPDES PERMIT# WAR306639 PUBLIC FRONTAGE IMPROVEMENT PLAN C5.1 27 PROTECT STORM DRAIN NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 RELOCATE FIRE HYDRANT TO PLANTER STRIPS RELOCATE HYDRANT TO PLANTER STRIP REMOVE EXISTING SIDEWALK RELOCATE GAS OUTSIDE OF SIDEWALK DEMOLITION NOTES 1.CONTRACTOR IS TO VERIFY LOCATION AND DEPTH OF ALL UTILITIES SHOWN. THE CONTRACTOR IS TO PROTECT UNDERGROUND UTILITIES DURING CONSTRUCTION. 2.CONTRACTOR TO PROTECT EXISTING STORM SYSTEM LOCATED IN FRONTAGE ALONG EAST VALLEY ROAD. 3.CONTRACTOR TO PROTECT EXISTING CURB AND GUTTER LOCATED IN FRONTAGE ALONG EAST VALLEY ROAD. DEMOLITION LEGEND PROPERTY BOUNDARY ROAD CENTERLINE RIGHT OF WAY BOUNDARY FUTURE ONSITE IMPROVEMENTS SIDEWALK EXISTING TREE EXISTING POWER EXISTING UTILITY POWER POLE EXISTING GAS LINE EXISTING COMMUNICATION LINE EXISTING WATER LINE EXISTING SEWER LINE FRONTAGE IMPROVEMENT LEGEND PROPERTY BOUNDARY ROAD CENTERLINE RIGHT OF WAY BOUNDARY ASPHALT PAVING PROPOSED SIDEWALK EXISTING SIDEWALK EXISTING TREE EXISTING GAS LINE EXISTING COMMUNITCATION LINE EXISTING WATER LINE EXISTING SEWER LINE EXISTING OVERHEAD POWER REMOVE WATER METER AND SERVICE LINE. REMOVAL TO BE PREFORMED BY CITY FORCES FUTURE PAVING LIMITSFUTURE SIDEWALK LIMITS RELOCATE VAULT OUTSIDE OF SIDEWALK SAWCUT LIMITS (TYP) PROTECT STORM DRAIN PROTECT EXISTING CURB AND GUTTER FRONTAGE IMPROVEMENT NOTESN GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 1.ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS AND SPECIFICATIONS. 2.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION AND DEPTH OF ALL UTILITIES SHOWN. 3.CONTRACTOR IS TO RAISE ALL REMAINING STRUCTURE LIDS TO BE FLUSH WITH FINISHED GRADE. REFER TO PLAN FOR REMAINING STRUCTURES. 4.ALL IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY SHALL CONFORM TO CITY OF RENTON CONSTRUCTION STANDARDS. PROVIDE PAVEMENT PATCH PER CITY OF RENTON STD. PLAN 110 PROVIDE PAVEMENT PATCH PER CITY OF RENTON STD. PLAN 110 PROVIDE CONCRETE DRIVEWAY PROVIDE CONCRETE DRIVEWAY RELOCATE HYDRANT TO PLANTER STRIP DEMOLITION PLAN IMPROVEMENTS PLAN RELOCATE GAS OUTSIDE OF SIDEWALK RELOCATE VAULT OUTSIDE OF SIDEWALK PROPOSED PARKING AREA PROVIDE 6' SIDEWALK 14' 30' 47'6.00' PROVIDE CURB RAMP PROVIDE CURB RAMP 3 C5.2 3 C5.2 PROVIDE FLUSH CURB AND GUTTER PROVIDE FLUSH CURB AND GUTTER 2 C5.2 2 C5.2 3 C5.3 PROVIDE 3.25' SIDEWALK WIDENING PROTECT TRANSMISSION POLE PROTECT TRANSMISSION POLE PROTECT TRANSMISSION POLE PROTECT TRANSMISSION POLE OVERHEAD POWER - USE CAUTION EXISTING OVERHEAD POWER IS HIGH VOLTAGE TRANSMISSION LINE R-406717 6' 2 C5.3 R25' R25' R25' R25' 9.25' RELOCATE SIGN TO PLANTER STRIP RELOCATE SIGN TO PLANTER STRIP 5' RELOCATE HYDRANT TO PLANTER STRIP RAISE VAULT TO FINISHED GRADE PROVIDE STREET LIGHTS PER PLAN. SEE SHEETS IL-01, 02, 03, AND PC-01 FOR MORE INFORMATION EAST VALLEY ROAD 08/07/2019