HomeMy WebLinkAboutPRE_20000049_Chelan_Short_Plat_Meeting Summary_200311PREAPPLICATION MEETING FOR Chelan Street Short Plat 1051 Chelan Ave NE PRE20-000049 CITY OF RENTON Department of Community & Economic Development Planning Division March 12, 2020 Contact Information: Planner: Matt Herrera, 425.430.6593, mherrera@rentonwa.gov Development Engineering: Michael Sippo, 425.430.7298, msippo@rentonwa.gov Fire: Corey Thomas, 425.276.9582, CThomas@rentonrfa.org Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects, and contractors who work on the project. You will need to submit a copy of this packet when you apply for land use and/or environmental permits. Pre-screening: When you have the project application ready for submittal, call and schedule an appointment with the project manager to have it pre-screened before making all of the required copies. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, , Department of Community & Economic Development Administrator, Public Works Administrator and City Council). 1 M E M O R A N D U M DATE:March 4, 2020 TO:Matt Herrera, Senior Planner FROM:Corey Thomas, Lead Plans Review Inspector SUBJECT:Chelan Short Plat 1. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. Existing dead end water main limits the available fire flow. If homes exceed 3,600 square feet, approved residential fire sprinkler systems would be required. 2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is paid at building permit issuance. Credit will be granted for any existing homes that are removed or retained. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Dead end streets that exceed 150-feet in length require an approved turnaround. Dead end streets that exceed 300-feet in length, require a full 90-foot diameter cul-de-sac type turnaround. Homes on dead end streets that exceed 500- feet, require an approved residential fire sprinkler system, regardless of size. In this case this would apply to Lots 2, 3, 5 and 6. 2 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE:March 11, 2020 TO:Matt Herrera, Planning FROM:Michael Sippo, Civil Plan Reviewer SUBJECT:Utilities & Transportation Comments for Chelan Ave NE Short Plat 1051 Chelan Ave NE PRE20-000049 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non- binding and may be subject to modification and/or concurrence by official City decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel(s) 1023059133. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1. Water service is currently being provided by King County Water District #90, however, is located within the City of Renton’s water service area. The existing service is being provided by a 4” water main located within Chelan Ave NE. 2. Due to being located within the City’s water service area, the new development will be required to connect to and extend City water to serve the new homes. 3. The site is located outside of an Aquifer Protection Area. 4. The development is within the City of Renton’s water service area in the Highlands 565-hydraulic pressure zone. There is an existing 8-inch City water main (see water plan no. W-3325) in Chelan Ave NE that can deliver a maximum flowrate of 1,250 gallons per minute (gpm). The static water pressure ranges from about 67 psi at ground level elevation 410 feet to 58 psi at ground level 432 feet. 5. Based on Renton Regional Fire Authority’s review comments on the submitted information for the pre-application, the preliminary fire flow demand for the development is 1,000 gpm for dwellings up to 3,600 square feet (including garage and basements.) If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow is required. 6. A minimum one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. The existing fire hydrants are not within 300 feet of all of the proposed new lots. A minimum of 1 new hydrant will be required. 3 Chelan Ave NE Short Plat – PRE20-000049 March 10, 2020 Page 2 of 6 7. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150- feet of all points on the buildings. Dead end streets that exceed 150-feet in length require an approved turnaround. 8. The maximum capacity of the existing 8-inch water main in Chelan Ave NE is 1,250 gpm. Looped water mains are required for flows over 2,500 gpm. 9. The following water system improvements will be required as part of the development: a. Abandon and cap the existing service from Water District #90. This work shall be coordinated directly with Water District #90 to meet all of its requirements. b. Installation of approximately 150 feet of a minimum 8-inch diameter water main spanning south to north along the project frontage in Chelan Ave NE. The water main will connect to the existing water main stub located in Chelan Ave NE. c. Installation of up to 300 feet of minimum 8-inch diameter water main within the interior residential street (extending to the west extents of the property) connecting to the new 8” water main located in Chelan Ave NE along the project’s frontage. d. A 15-foot utility easement will be required for any water main and for related appurtenances that are not located within the public right-of-way. e. Installation of additional fire hydrants as required by the Renton Regional Fire Authority. The final location and number of the hydrants shall be determined by the Fire Authority based on the final site plan. f. Installation of a separate domestic water meter and service line (minimum 1-inch in size) to each new home. The sizing of the domestic water meters shall be done in accordance with Chapter 6 of Uniform Plumbing Code. A double check valve assembly (DCVA) is required behind the domestic water meter if the buildings are 3-story or more. 10. Installation of a “Storz” adapter on the existing hydrants, if they are not already equipped with one. 11. Retaining walls, rockeries or similar structures cannot be installed over the water main unless the water main is inside a steel casing. 12. A conceptual utility plan will be required as part of the land use application for the subject development. 13. Civil plans for the water main improvements will be required and must be prepared by a registered professional engineer in the State of Washington. A civil plan showing the preliminary water main extension shall be submitted with the land use application. 14. Adequate separation between utilities is required. Minimum separation between water and all other utilities is 10-feet horizontal and 1.5-feet vertical. 15. The development is subject to applicable water system development charges (SDC’s) and meter installation fees based on the number and size of the meters for domestic uses and for fire sprinkler use. The development is also subject to fees for water connections, cut and caps, and purity tests. Current fees can be found in the 2020 Development Fees Document on the City’s website. Fees that are current will be charged at the time of construction permit issuance. a. The SDC fee for water is based on the size of the new domestic water to serve the project. The current water fee for a single 3/4 x 5/8-inch or 1-inch meter is $4,400.00 per meter. b. The SDC fee for fire service is based on the size of the fire service line to serve the project (if required). 4 Chelan Ave NE Short Plat – PRE20-000049 March 10, 2020 Page 3 of 6 c. The existing meter serving the 1051 residence will require abandonment due to being owned by Water District #90. Since the service is being provided by another district, it is not eligible for an SDC connection credit. d. Water service installation charges for each proposed domestic water service is applicable. Water Service installation for a 3/4 x 5/8-inch or 1-inch water service line is $2,875.00* per service line. This is payable at construction permit issuance. e. SDC fees are assessed and payable at construction permit issuance. SEWER 1. Sewer service is provided by City of Renton. 2. There is an 8-inch wastewater main located in Chelan Ave NE that terminates at the southeast corner of the property and does not extend along the project frontage (S-3325). 3. The existing septic drainfield located at 1051 Chelan Ave NE will need to be decommissioned and removed in accordance to Washington State Department of Health Requirements. 4. Public sanitary sewer will be required to be extended along the entirety of the project frontage to the north approximately 150 lineal feet. 5. Public sanitary sewer will be required to be extended to the west along the proposed public street to the terminus of the public street (hammerhead or turnaround) for an approximate length of 200 lineal feet or to the maximum extent feasible to serve gravity sewer. 6. Lots located on the western half of the site will either require extensive fill (10 to 15 feet) to provide gravity sanitary sewer or provide private lift stations. 7. A separate side sewer will be required for each building. All new sewer stubs shall be a minimum of 6” and shall run at a slope of at least 2% to the main. Any buildings which cannot achieve a gravity connection will need a private lift station(s). 8. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. The current sewer fee for a 1-inch meter install is $3,400.00 per meter. Since the existing home is currently being served by a private septic drainfield it is not eligible for an SDC connection credit. 9. The Honey Creek Sewer Interceptor (Residential) Special Assessment District fee (SAD) fee will be applicable to the project. The SAD fee rate when it was established in 1986. The Honey Creek Sewer Interceptor (Residential) has reached its peak assessment. The SAD Fee for the project will be $250.00/lot. Since the property does not currently front sewer main, no additional assessment for front foot will be assessed. SURFACE WATER 1. A drainage report complying with the current version of the City adopted Surface Water Design Manual (SWDM) will be required. Based on the City’s flow control map, the site falls within the Flow Control Duration Standard area matching Forested Site Conditions and is within the May Creek – Honey Creek Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. 2. The site contains regulated slopes near the west property line. The site topography slopes from slight to moderate from east to west. There is a 12-inch stormwater main (R-3325) in Chelan Ave NE south of the subject property frontage located along the west side of the existing roadway. The stormwater main drains to a private water quality facility located on the 102305-9129 and 9468 parcels. The Applicant will need to ensure that this conveyance and water quality system is protected. 5 Chelan Ave NE Short Plat – PRE20-000049 March 10, 2020 Page 4 of 6 3. There is a City-owned storm drainage pond located on the adjacent parcel to the site’s western south half (Facility ID No. 111336 – D-3645). The applicant will need to ensure that the stormwater pond and associated appurtenances and property are protected. 4. Per the September 30, 2019 Wetland Delineation Report prepared by the Watershed Company, there is an existing Category 3 wetland (Wetland C) located on the adjacent parcel to the north near the site’s northwest corner. The wetland buffer is 100’ with an additional 15’ building setback line (BSBL). Any modification or development on or within the wetland buffer will be required to meet the 2017 Renton Surface Water Design Manual requirements and chapter 4-3- 050, Critical Areas Regulations, of the City of Renton Municipal Code. 5. Detailed plans for any proposed cut and fill operations shall be submitted. These plans shall include the angle of slope, contours, compaction and retaining walls. 6. Maximum retaining wall height is 6-ft from finished grade. Based on the site topography, terraced retaining walls may be needed for the development. Retaining walls over 4-feet in height from footing require a separate building permit. 7. Maintenance access is required for any proposed stormwater tract and shall be designed and installed in accordance with the City adopted SWDM. 8. Storm drainage improvements along all public street frontages are required to conform to the City’s street and stormwater conveyance standards. Any new storm drain installed on or off-site shall be designed and sized in accordance with standards found in Chapter 4 of the 2017 RSWDM and shall account for the total upstream tributary area, assuming developed conditions for onsite tributary areas and existing conditions for any offsite tributary areas. 9. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide basic water quality treatment. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 10. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2017 RSWDM. A preliminary drainage plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. 11. A Construction Stormwater Permit from Department of Ecology is required since clearing and grading of the site will exceed one acre. 12. A geotechnical soils report for the site is required per the 2017 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 13. Erosion control measures to meet the City requirements shall be provided. 14.The current City of Renton Surface Water Standard Plans that shall be used in all drainage submittals are available online at the City of Renton website. https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton. 6 Chelan Ave NE Short Plat – PRE20-000049 March 10, 2020 Page 5 of 6 15. The 2020 Surface water system development fee is $0.76 per square foot of new impervious surface, but no less than $1,900.00 for each new lot. This is payable prior to issuance of the construction permit. This fee is subject to change based on the calendar year the construction permit is issued. TRANSPORTATION 1. The proposed development fronts Chelan Ave NE along the east property line. Chelan Ave NE is currently underdeveloped along the property frontage and contains only a private 18’ wide joint use driveway/private street spanning from the south property line and to the north and onto adjacent northern properties. 2. South of the proposed development, Chelan Ave NE is developed to the intersection with NE 10 th Street. The street was developed under previous road standards and does not meet current requirements. The street consists of a pavement width of approximately 30’ with curb, gutter and 5’ sidewalks on both sides and a right-of-way width of 42’. 3. Chelan Ave NE is classified as a Residential Access Street. The existing ROW width is approximately 12 feet. To meet the City’s complete street standards for residential streets, minimum ROW is 53 feet. The project will be required to construct the following frontage improvements along the entire Chelan Ave NE frontage: a. 35.5 feet of ROW dedication. b. The half street section will include (2) 10’ travel lanes, 0.5’ curb, 8’ planter, and 5’ sidewalk. 4. Per RMC 4-6-060 (J) shared driveways are only allowed to serve a maximum of 4-lots. Since the project is proposing 6 lots, a public residential street meeting RMC 4-6-060 (F) is required. The project will be required to construct a residential street meeting the following requirements: a. 53 feet of ROW dedication along the interior portion of the site running from east to west where the street terminates in a public cul-de-sac or hammer-head turn-around. b. The full street section consists of: 26’ of pavement (2-10’ travel lanes and 1-6’ parking lane), (2) 0.5’ curbs, (2) 8’ planter strips, and (2) 5’ sidewalks. c. Per RMC 4-6-060, Cul-de-sacs shall have a minimum paved and landscaped radius of forty five feet (45') with a right-of-way radius of fifty five feet (55') for the turnaround. A landscaped center island with a radius of twenty feet (20') delineated by curbing shall be provided in the cul-de-sac. d. Dead-end streets measured between 150 and 300-feet may utilize a hammerhead turnaround meeting the requirements for emergency services access, including a 25- foot radius and a length of 45’. Reference RMC 4-6-060H. The hammerhead shall have a design approved by the Administrator and Fire and Emergency Services. 5. Street grades shall not exceed 15 percent. 6. ADA access ramps shall be installed at all street crossings. Ramps shall be shown at each intersection. Ramps shall be oriented to provide direct pedestrian crossings. 7. Refer to City code 4-4-080 regarding driveway regulations: a. Driveways shall be designed in accordance with City standard plans 104.1 and 104.2. b. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage. c. The maximum width of a single loaded garage driveway is 9-feet and the maximum width of a double loaded garage driveway is 16-feet. If a garage is not present, the maximum driveway width is 16-feet. 7 Chelan Ave NE Short Plat – PRE20-000049 March 10, 2020 Page 6 of 6 d. Driveways shall not be closer than 5-feet to any property line. 8. Street lighting and street trees are required to meet current city standards. Lighting plans are required to be submitted with the land use application and will be reviewed during the construction utility permit review. 9. A traffic impact analysis is required when the estimated vehicular traffic generated from a proposed development exceeds 20 vehicles per hour in either the AM (6:00 – 9:00) or PM (3:00 – 6:00) peak periods. The analysis must include a discussion on traffic circulation to and from the site and onsite traffic circulation. The study shall include trip generation and trip distribution for the project for both AM and PM peak hours. 10. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 11. The transportation impact fee is based on the type of land use. For a single family dwelling, the 2020 transportation impact fee is $7,820.42. Transportation impact fees are subject to change based on the year the building permit is applied for. GENERAL COMMENTS 1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property frontage or within the site must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls. 3. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements: a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 4. All civil construction permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 5. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on separate sheets. 6. A demo permit is required for the demolition of any existing building(s). The demo permit shall be acquired through the building department. 7. Fees quoted in this document reflect the fees applicable in the year 2020 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. 8 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE:March 12, 2020 TO:Pre-Application File No. PRE20-000049 FROM:Matt Herrera, Senior Planner SUBJECT:Chelan Street Short Plat 1051 Chelan Ave NE General: We have completed a preliminary review of the pre-application for the above- referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision- makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are linked here and available online at www.rentonwa.gov Project Proposal: The project site (APN 102305-9133) is located at 1051 Chelan Ave NE and totals approximately 46,609 square feet (1.07 acres) in area and is zoned Residential-8 (R-8). The applicant proposes is to subdivide the existing parcel into six (6) single-family lots. The narrative indicates lot size ranges from 5,000 to 6,000 square feet. Access to the proposed lots would be provided via a two (2) abutting shared driveway tracts extending from Chelan Ave NE. Previous wetland studies indicate a Category III wetland is located on the abutting northern property Current Use: The property is developed with an existing single family home. It appears from the short plat drawing that the existing single family home would be removed. Zoning/Density Requirements: The subject property is zoned Residential-8 (R-8). The minimum density in the R-8 zone is 4.0 dwelling units per net acre (du/ac) and the maximum density is 8.0 du/ac. Private access easements, critical areas (except buffers), and public right-of-way are excluded from the total area to determine net density. Alleys (public or private) are not excluded. The applicant would be required to demonstrate compliance with the net density requirements of the zone at the time of prior to the City accepting the short plat application for review. A completed Density Worksheet will be required with the master application. Development Standards: The project would be subject to RMC 4-2-110A, “Development Standards for Residential Zoning Designations (Primary Structures)” effective at the time of complete application. Please refer to this code section in its entirety when preparing application submittal materials. The following are some of the standards that would apply to your proposal: 9 Chelan Street Short Plat Preapplication Meeting March 12, 2020 R-8 Development Standards Minimum Lot Size 5,000 square feet Minimum Lot Width 50-feet Minimum Lot Width (Corner Lots)60-feet Minimum Lot Depth 80-feet Minimum Front Yard 20-feet or 15-feet with alley access Minimum Secondary Front Yard (Corner Lots)15-feet Minimum Rear Yard 20-feet (corner lots utilize the side yard setback in place of the rear yard) Minimum Side Yard 5-feet Maximum Building Coverage 50-percent Maximum Impervious Surface Area 65-percent Maximum Height Two stories and maximum wall plate height of 24-feet. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height. Minimum Tree Density 2 significant trees per 5,000 sf. of lot area Lots do not appear to meet width or depth requirements. Proposed building footprints do not appear to meet setbacks. Front yard setbacks for Lots 1, 2, 4, and 5 appear to be 10-feet. Setback compliance would be verified at the time of single family building permit review. Building coverage, impervious surface, height requirements would be verified at the time of single family building permit review. Residential Design Standards: New homes within the subdivision would be subject to the Residential Design Standards outlined in RMC 4-2-115. Key characteristics of the design standards include a variety of housing architectural styles, enhanced by attention to selection of exterior materials, colors, architectural detailing, and ensuring that garages do not visually dominate the streetscape. The proposal’s compliance with the residential design standards would be verified at the time of building permit review. Landscaping: Except for critical areas, all portions of the development area not covered by structures, required parking, access, circulation or service areas, must be landscaped with native, drought-resistant vegetative cover. The minimum on-site landscape width required along street frontages (private side) is 10 feet and shall contain trees, shrubs, and landscaping. The applicant would also be required to provide planting in the 8-foot wide landscape strip between the curb and sidewalk with groundcover and a minimum of one (1) street tree per new lot along the newly constructed Chelan Ave NE frontage. A 15-foot perimeter landscaping screen is required around any storm drainage facility. A conceptual landscape plan would be required to be submitted with the land use application. 10 Chelan Street Short Plat Preapplication Meeting March 12, 2020 Significant Tree Retention: If significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are proposed to be removed, a Tree Retention/ Land Clearing (Tree Inventory) Plan, arborist report, and tree retention worksheet shall be provided with the master application. The tree retention plan must show preservation of at least 30 percent (30%) of significant trees, and indicate how proposed building footprints would be sited to accommodate preservation of significant trees that would be retained. Tree retention standards shall be applied to the developable area of a property (i.e., land within critical areas and their buffers, public rights-of-way, private PUD streets, shared driveways, and public trails shall be excluded). If the number to be retained includes a fraction of a tree, any amount equal to or greater than one-half (1/2) tree shall be rounded up. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that an insufficient number of trees can be retained. In addition to retaining 30% of existing significant trees, each newly created lot would be required to provide a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected trees that do not contribute to a lot's required minimum tree density shall be held in perpetuity within a tree protection tract. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; Other significant native evergreen or deciduous trees; and Other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. The Administrator may require independent review of any land use application that involves tree removal and land clearing at the City's discretion. If staff determines that the trees cannot be retained, replacement trees, with at least a 2-inch caliper or an evergreen at least 6 feet tall, shall be planted at a rate of 12 caliper inches of new trees to replace each protected tree removed. A tree retention plan prepared by an arborist or landscape architect would be reviewed at the time of land use application. Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project, the location must be designated on the landscape plan and grading plan. A fence and/or wall detail should also be included on the plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the bottom of the footing to the finish grade at the top of the wall requires a building permit. A fence shall not be constructed on top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the allowed height of a standalone fence. For more information about fences and retaining walls refer to RMC 4-4-040. Retaining wall heights for residential development are limited to 6-feet in height for interior side yards and rear yards and 4-feet in height front yards and side or rear yards along a street. Terrace widths must be equal to the wall height and landscaped. Retaining walls shall be 11 Chelan Street Short Plat Preapplication Meeting March 12, 2020 composed of brick, rock, textured or patterned concrete, or other masonry product that compliments the proposed building and site development. Access: Access to the proposed lots is shown as two (2) abutting shared driveway tracts each serving three (3) lots with no turnaround. The City would not permit to abutting shared driveway tracts and a public street would be required to serve six (6) lots. Shared driveways may be considered by the City for access to four (4) or fewer lots, provided: At least one of the four (4) lots abuts a public right-of-way and the street frontage of the lot is equal to or greater than the lot width requirement of the zone; The subject lots are not created by a subdivision of ten (10) or more lots; A public street is not anticipated by the City of Renton to be necessary for existing or future traffic and/or pedestrian circulation through the short subdivision or to serve adjacent property; The shared driveway would not adversely affect future circulation to neighboring properties; The shared driveway is no more than three hundred feet (300') in length; and The shared driveway poses no safety risk and provides sufficient access for emergency vehicles and personnel. Shared Driveway Standards: Shared driveways shall be within a tract; the width of the tract and paved surface shall be a minimum of sixteen feet (16'); the Fire Department may require the tract and paved surface to be up to twenty feet (20') wide. If a shared driveway abuts properties that are not part of the subdivision, an eight foot (8') wide landscaped strip shall be provided between the shared driveway and neighboring properties. The landscape strip shall be within a tract and planted with a mixture of trees, shrubs, and groundcover, as required in RMC 4-4-070. The shared driveway may be required to include a turnaround. No sidewalks are required for shared driveways; however, drainage improvements pursuant to City Code are required (i.e., collection and treatment of stormwater), as well as an approved pavement thickness. The maximum grade for the shared driveway shall not exceed fifteen percent (15%), except for within approved hillside subdivisions. Dead End Streets: Be advised that dead-end streets between 150-feet to 300-feet in length require a dedicated hammerhead turnaround and dead end streets between 300-feet to 500-feet require a cul-de-sac. Alley Access - Alley access is the preferred street pattern for all new residential development in the R-8 zone. If the developer or property owner demonstrates that alley access is not practical, the use of alleys may not be required. For parcels in the R-8 zone, the maximum density shall be six (6) dwelling units per net acre when alleys are not part of the proposed or existing street configuration, and alleys are considered practical. Driveways and Parking: The maximum width of single loaded garage driveways shall not exceed nine feet (9') and double loaded garage driveways shall not exceed sixteen feet (16'). Except for joint use driveways, driveways shall not be closer than five feet (5') to any property line. Maximum driveway slopes shall not exceed fifteen percent (15%); provided, that driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage/residence or crossing any public sidewalk. To exceed fifteen percent (15%), a variance is required. Each lot would be required to provide a minimum of 12 Chelan Street Short Plat Preapplication Meeting March 12, 2020 two (2) parking spaces. A maximum of 4 vehicles may be parked on a lot, including those vehicles under repair and restoration, unless kept within an enclosed building. Compliance with the driveway regulations would be verified at the time of formal land use review. Critical Areas: A wetland delineation report was prepared by The Watershed Company dated September 30, 2019 indicates that a Category III wetland is located just north of the subject property. Category III wetlands require a 100-foot buffer and 15-foot building setback from that buffer. The buffer and setback will affect the western portion of the subject property. A native growth protection area would be required to be instituted to protect the critical area from development. This area would be required to be placed within a tract via the short plat with a covenant and deed restriction that prohibits any development, alteration, or disturbance within the native growth protection area. The short plat will be required to provide a tract for the delineated wetland buffer. It is the applicant’s responsibility to ascertain whether any additional critical areas or environmental concerns are present on the subject property prior to site development or building construction. Environmental Review: Typically short plats are exempt from State Environmental Policy Act (SEPA) review, however due to the wetland buffer located on the subject property an environmental checklist must be submitted with the short plat application. A threshold determination will be issued prior to or concurrently with the short plat decision. Permit Requirements: The proposal would require administrative short plat approval. The application would be reviewed within an estimated time frame of six to eight weeks. The 2020 administrative short plat application fee is $5,544.00 ($5,280.00 plus a 5% Technology Surcharge Fee) and the environmental checklist fee is $1,659.00 ($1,580.00 plus 5% Technology Surcharge Fee). All fees are subject to change. Detailed information regarding the land use application submittal can be found in CED Forms on the City’s Digital Records Library under the Community and Economic Development tab on the City’s website at www.rentonwa.gov. The City requires electronic plan submittal for all applications. Once Preliminary Short Plat approval is obtained, the applicant must obtain a civil construction permit to complete the required improvements and dedications, as well as satisfy any conditions of the preliminary approval before submitting for Final Short Plat review. Once final approval is received, the plat may be recorded. The newly created lots may only be sold after the plat has been recorded. Single family building permits will be required for the future homes. Public Notice: The applicant is required to install a proposed land use action sign on the subject property per the specifications provided in the public information sign handout. The applicant is solely responsible for the construction, installation, maintenance, removal, and any costs associated with the sign. See the Public Information Sign handout on the City’s website for more information and specifications. Fees: In addition to the applicable building and construction fees, impact fees would be required. Such fees would apply to all projects and would be calculated at the time of building permit application and payable prior to building permit issuance. The 2020 impact fees are as follows: A Transportation Impact Fee based on $7,820.42 per each new detached dwelling unit. A Parks Impact Fee based on $3,945.70 per each new detached dwelling unit. A Fire Impact fee of $829.77 per each new detached dwelling unit. Renton School District Impact Fee is $6,862.00 per each new detached dwelling unit. 13 Chelan Street Short Plat Preapplication Meeting March 12, 2020 The City of Renton Fee Schedule that includes development related fees is available on the City of Renton website for your review. Next Steps: When the formal application materials are complete, the applicant shall have the materials pre-screened prior to submitting the complete application package. Please contact Matt Herrera, Senior Planner at 425-430-6593 or mherrera@rentonwa.gov to schedule a prescreen appointment. Expiration: The preliminary short plat approval is valid for five years with a possible one year extension (RMC 4-7-070M). It is the responsibility of the owner to monitor the expiration date. 14 1,128 94 Chelan Short Plat Utilities This map is a user generated static output from an Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. None 3/11/2020 Legend 64032 THIS MAP IS NOT TO BE USED FOR NAVIGATION Feet Notes 64 WGS_1984_Web_Mercator_Auxiliary_Sphere Information Technology - GIS RentonMapSupport@Rentonwa.gov City and County Labels City and County Boundary Addresses Parcels Renton Fire Hydrants Hydrants - Other System System Valves Opened Closed Control Valves Water Fittings Water Gravity Pipes Water Mains Mains - Other System Lateral Lines Domestic Fire Hydrant Irrigation Lift Stations Clean Outs Manholes Service Connections Wasterwater Taps Sanitary Sewer Fittings Lateral Lines15