HomeMy WebLinkAboutT-4006030
C)
O
(5
z
m
O
W
w
IL
V)
W
0-
0-
zz
J
L,
0
C)
O
0
W
N M
I �
0
N z J
1 Y
to 0
9 3 W
o a o W
BETHANY CORNER
A PORTION OF THE NE 1/4 OF SECTION 29, T. 29 N., R. 05 E., W.M.
CITY OF RENTON, STATE OF WASHINGTON
Z f1 °
0
aLj-
z
m J j
1.9..S.•.
4.C.. I 4
I ---------- I I I I L— I ;..........
O --� L---- \. . . . . . . . . .
- - - - - _ 1 o J_OIN T U TILI TY - -------�-: I I ; ......... I I
o EASEMENT ~ . .4----------� - ; ....... .
I T — T TYP.
O
I
50' RT
[-4 X �...
'ORNER
®... g --- ---- --
:1 ;. 6 _ .
m
2 O--------------
--F� ,� 1 22+ 00
r)E AND — - �x X 1 21 + 00 1 -- -- --- _---- _-- _1 __ ..^..
�I SLOPE I =_--- -_- ---- - — 1-� —X— - -- --
�FETY I 1 STRIP (TYP. E 765TH S 1 N c
-------I------- ST 1
m
�z g
s R 'A/L- ---- - --
T —
w= OF I
o _
20 ASPHALT — —
I PA VING 1 008800-0560 1 1 —
N zo I I F - - - --, ,--------- ---- SHED +' I
I-
11 W 1 101' JOINT UTILITY i i x — 1 :.a : .......:... I
1 I EASEMENT I
0 40< L -
-I _ � 5 / ff
I TYP. I I P R STD LAN 102 I I a I..
V..........
LUMINAIRE SCHEDULE ...........I
W
W
0
o
3
qa
0
w
a
N
0
0
U
Q
a_
a_
Q
N
rn
i.
r
ONO
't
r
N
Q
000o
m
C/) U) U)
f_ z z z
z 00 0
�»
12 w w 0 w
[If [If
U
J —i
U d d
w
a- U5
11 IN -1 0
LUM.
N0.
POLE
ID. NO.*
CIRCUIT
NO.
LOCATION
COORD.
OFFSET
(FEET)
LED LAMP
WATTAGE
MAST ARM
(FEET)
MOUNTING
HGT. (FT.)
STANDARD
PLAN #
LAT.
LONG.
1
A
111 TH AVE SE 8+99
17.5' LT
44 LED
NA
14'
116.1
2
A
111 TH AVE SE 9+51
17.5' LT
44 LED
NA
14'
116.1
3
A
111 TH AVE SE 10+06
17.5' LT
44 LED
NA
14'
116.1
4
A
111 TH AVE SE 11 +16
17.5' LT
44 LED
NA
14'
116.1
5
A
111 TH AVE SE 11 +71
17.5' LT
44 LED
NA
14'
116.1
6
A
SE 165TH ST 20+50
17.5' RT
44 LED
NA
14'
116.1
7
A
SE 165TH ST 20+97
17.5' LT
44 LED
NA
14'
116.1
8
A
SE 165TH ST 21+27
17.5' RT
44 LED
NA
14'
116.1
9
A
SE 165TH ST 21+91.5
17.5' LT
44 LED
NA
14'
116.1
10
A
SE 165TH ST 22+22.5
17.5' RT
44 LED
NA
14'
116.1
* NOTE: POLE ID NOS. ARE TO BE PROVIDED BY THE CITY AT TIME OF CONSTRUCTION.
COORDINATES SHALL BE PROVIDED IN THE AS -BUILT PLANS.
20 0 20 40
scale feet
CALJT/DN:
LOCATION OF EXISTING UTILITIES SHOWN IS
APPROXIMATE AND MAY NOT BE ACCURATE
OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO POTHOLE AS REQUIRED
AND FIELD VERIFY LOCATION OF UTILITIES
PRIOR TO PROCEEDING WITH CONSTRUCTION.
UNDERGROUND UTILITY NOTE:
YOU MUST CALL 811 NOT LESS THAN 72 HOURS
BEFORE BEGINNING EXCA VA TION WHERE ANY UNDERGROUND
UTILITIES MAYBE LOCATED. FAILURE TO DO SO COULD MEAN
BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE
COST OF REPAIRS TO THE SERVICE).
1
' OP
TRANSFOR
a
13
008800-C
0
a
0
0
FUTURE
LUMINAIRE
BY OTHERS
I a
o
-- TRANSFORM
❑P
008800-0�
008800-0:
BOLLARD(TYP
o '
o
7 1
008800-0-
I
SSI
RIN
CONSTRUCTION NOTES
Di
INSTALL
NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE FIXTURE AND PULE PER STANDARD PLAN 116.1,
CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 2 AND 3, AND
LUMINAIRE POLE
SCHEDULE.
2O
INSTALL
ELECTRICAL SERVICE CABINET # XXX PER DETAILS ON SHEET 3, LOCATED ON ROAD A
AT APPROXIMATE
STATION
9+31, 29' LT, COORDINATE WITH C.O.R, ERIC CUTSHALL, TRANSPORTATION MAINTENANCE
MANAGER,
425-430-7423,
FOR SERVICE CONNECTION. LABEL STREET FACING SIDE OF CONTACTOR CABINET
WITH ADDRESS
LOCATION
FOLLOWING COR STANDARD PLAN 122.1.
O3
INSTALL
TYPE 1 JUNCTION BOX WITH CONCRETE PAD PER COR STANDARD PLAN 120,
WIRING SCHEDULE
CONDUIT
RUN
ZL
CONDUIT
SIZE
CONDUCTORS
NOTES
1
2.0"
PVC
(SCHEDULE
40)
2-#8,
1-#8 GREEN
2
2.0"
PVC
SCHEDULE
80
2- 8,
1- 8 GREEN
3
2.0"
PVC
(SCHEDULE
40)
2-#8,
3-#14
1-#8 GREEN
PHOTOCELL
4
2.0"
PVC
SCHEDULE
40
PSE
POWER
5
2.0"
PVC
(SCHEDULE
40)
PULL
STRING -
LEGEND.
LED PEDESTRIAN LUMINAIRE
AND DECORATIVE POLE
— — — — — — —
PVC CONDUIT (SEE WIRING SCHEDULE)
TYPE 1 JUNCTION BOX WITH
®
CONCRETE PAD
®
SERVICE CABINET
AWIRE
NOTE
O
CONSTRUCTION NOTE
T-400603
R-400622
RECOMMENDED
FOR APPROVAL
BY
BY
BY
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
DATE
DATE
DATE
Traff
NORTHWEST Ex
TRA FT -IC EXPERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone:425.522.4118 Fax:425.522.4311
NAL
5-28-21