HomeMy WebLinkAboutEx03_Plan_DrawingsREMOVE EXISTING CURB AND GUTTER. EXISTING CONCRETE SIDEWALK TO REMAIN. EXISTING CONCRETE PAVEMENT TO REMAIN. EXISTING ASPHALT TO REMAIN. EXISTING CURB AND GUTTER TO REMAIN. EXISTING LIGHT POLE TO REMAIN AND TO BE PROTECTED IN PLACE THROUGHOUT CONSTRUCTION. SHORING MAY BE REQUIRED DURING CONSTRUCTION. EXISTING FIRE HYDRANT TO REMAIN AND TO BE PROTECTED IN PLACE THROUGHOUT CONSTRUCTION. EXISTING STORM VAULT TO REMAIN AND TO BE PROTECTED IN PLACE THROUGHOUT CONSTRUCTION. REMOVE EXISTING LANDSCAPING. EXISTING LANDSCAPING TO REMAIN AND TO BE PROTECTED IN PLACE THROUGHOUT CONSTRUCTION. CONTRACTOR TO REPLACE ANY DAMAGED LANDSCAPING. EXISTING FIRE HYDRANT TO BE RELOCATED. (SEE UTILITY PLAN) EXISTING LIGHT POLE TO BE REMOVED AND RELOCATED. EXISTING CONCRETE SIDEWALK TO BE REMOVED. SAWCUT EXISTING PAVEMENT TO CLEAN EDGE AND REMOVE PAVEMENT WITHIN SAWCUT BOUNDARY, BOTH ASPHALT AND CONCRETE. EXISTING STORM SEWER INLET TO REMAIN AND TO BE PROTECTED THROUGHOUT CONSTRUCTION. EXISTING STOP SIGN TO REMAIN. EXISTING PAVEMENT MARKINGS TO REMAIN. EXISTING PAVEMENT MARKINGS TO BE REMOVED. EXISTING PARKING STRIPING TO REMAIN. EXISTING PARKING STRIPING TO BE REMOVED. PROPOSED ASPHALT PAVEMENT (SEE SITE DETAILS). PROPOSED OGP PICKUP STALL STRIPING (SEE SITE DETAILS). PROPOSED OGP PICKUP STALL SIGNAGE ANGLED AT 45° AS SHOWN ON PLAN ON BOLLARD OR ATTACHED TO CANOPY COLUMN AS SHOWN. (SEE SITE DETAILS). PROPOSED CURB AND GUTTER (SEE SITE DETAILS). PROPOSED OVERHEAD OGP CANOPY (SEE ARCHITECTURAL PLANS). PROPOSED CANOPY COLUMN AND FOOTING (SEE ARCHITECTURAL PLANS). PROPOSED SAFETY YELLOW 42" FLEXIBLE PLASTIC BOLLARD. GC TO ORDER FROM IMPACT RECOVERY SYSTEMS, INC. AT 210-736-4477 OR SIMILAR. BORING FOR CONDUIT THROUGH ASPHALT. PROPOSED 2' O.C. YELLOW STRIPING AT 45°. PROPOSED LOCATION FOR EXISTING LIGHT POLE AND FIXTURE TO BE RELOCATED. (SEE UTILITY PLAN) PROPOSED PAVEMENT MARKING. (SEE SITE DETAILS) PROPOSED BUILDING ADDITION. (SEE ARCHITECTURAL PLANS) PROPOSED CONCRETE PAVEMENT. (SEE SITE DETAILS) PROPOSED ASSOCIATE CROSSWALK. (SEE SITE DETAILS) PROPOSED BOLLARD WITH MOUNTED PEDESTRIAN CROSSING SIGN (SEE SITE DETAILS) PROPOSED CANOPY COLUMN FOR ELECTRICAL CONNECTION (SEE UTILITY PLAN) EXISTING BUILDING TO REMAIN EXISTING BOLLARD TO REMAIN EXISTING FENCE TO REMAIN EXISTING CURB & GUTTER TO REMAIN EXISTING STORM INLET TO REMAIN EXISTING SIGN TO REMAIN EXISTING SITE LIGHTING TO REMAIN EXISTING SITE LIGHTING TO BE RELOCATED EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING FIRE HYDRANT TO BE RELOCATED PROPOSED FIRE HYDRANT EXISTING CONCRETE PAVEMENT EXISTING ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT PROPOSED ASPHALT PAVEMENT SEAL COAT TO REMOVE EXISTING STRIPING FOR NEW PICKUP STALLS AND ASSOCIATED PARKING STALL MODIFICATIONS. PROPOSED PICK-UP SIGN PROPOSED CURB AND GUTTER PROPOSED SAWCUT LINE AND LIMITS OF REMOVAL PROPOSED OGP CANOPY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 X X 1 inch = 30 ft. ( IN FEET ) GRAPHIC SCALE 030 30 60 12015 Y KEY MAP NOT TO SCALE SITE 30 31 NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK. NOTE: CONTRACTOR RESPONSIBLE FOR AS-BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION AT THEIR COST. GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY REGULATIONS AND CODES AND O.S.H.A. STANDARDS. 2. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 3. ALL CURBED RADII ARE TO BE 2' OR 10' UNLESS OTHERWISE NOTED. 4. ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 5. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, (UNLESS OTHERWISE NOTED ON PLANS) INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. 7. SITE BOUNDARY, TOPOGRAPHY, UTILITY AND ROAD INFORMATION TAKEN FROM A SURVEY BY A LAND SURVEYOR. 8. THE SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED "THE SITE SPECIFIC SPECIFICATIONS". SWPPP NOTES CONTRACTOR SHALL PREVENT ANY EROSION AND/OR SEDIMENTATION TRANSPORT FROM BEING RELEASED FROM THE REPAIR AREAS THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL UTILIZE BMP'S (STRAW WATTLES, SILT DIKE ON PAVEMENT, ETC.) AS NECESSARY TO PREVENT RUNOFF FROM THE REPAIR AREAS. DEMOLITION NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR THE DEMOLITION, REMOVAL, AND DISPOSAL (IN A LOCATION APPROVED BY ALL GOVERNING AUTHORITIES) ALL STRUCTURES, PADS, WALLS, FLUMES, FOUNDATIONS, PARKING, DRIVES, DRAINAGE STRUCTURES, UTILITIES, ETC., SUCH THAT THE IMPROVEMENTS SHOWN ON THE PROPOSED PLANS CAN BE CONSTRUCTED. ALL FACILITIES TO BE REMOVED SHALL BE UNDERCUT TO SUITABLE MATERIAL AND BROUGHT TO GRADE WITH SUITABLE COMPACTED FILL MATERIAL PER THE SPECIFICATIONS. PRIOR TO DEMOLITION OCCURRING, ALL EROSION CONTROL DEVICES ARE TO BE INSTALLED. 2. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL DEBRIS FROM THE SITE AND DISPOSING THE DEBRIS IN A LAWFUL MANNER. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED FOR DEMOLITION AND DISPOSAL. 3. THE CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY COMPANIES PRIOR TO THE REMOVAL AND/OR RELOCATION OF UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNING PORTIONS OF WORK WHICH MAY BE PERFORMED BY THE UTILITY COMPANY THEMSELVES AND ANY FEES WHICH ARE TO BE PAID TO THE UTILITY COMPANY FOR THEIR SERVICES. THE CONTRACTOR IS RESPONSIBLE FOR PAYING ALL FEES AND CHARGES. 4. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN ON THIS PLAN HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY DEMOLITION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES FOR MARKING ONSITE LOCATIONS OF EXISTING UTILITIES. 5. ALL EXISTING SEWERS, PIPING AND UTILITIES SHOWN ARE NOT TO BE INTERPRETED AS THE EXACT LOCATION, OR AS THE ONLY OBSTACLES THAT MAY OCCUR ON THE SITE. VERIFY EXISTING CONDITIONS AND PROCEED WITH CAUTION AROUND ANY ANTICIPATED FEATURES. GIVE NOTICE TO ALL UTILITY COMPANIES REGARDING DESTRUCTION AND REMOVAL OF ALL SERVICE LINES AND CAP ALL LINES BEFORE PROCEEDING WITH THE WORK. UTILITIES DETERMINED TO BE ABANDONED AND LEFT IN PLACE SHALL BE GROUTED IF UNDER BUILDING. 6. ELECTRICAL, TELEPHONE, CABLE, WATER, FIBER OPTIC CABLE AND/OR GAS LINES NEEDING TO BE REMOVED OR RELOCATED SHALL BE COORDINATED WITH THE AFFECTED UTILITY COMPANY. ADEQUATE TIME SHALL BE PROVIDED FOR RELOCATION AND CLOSE COORDINATION WITH THE UTILITY COMPANY IS NECESSARY TO PROVIDE A SMOOTH TRANSITION IN UTILITY SERVICE. CONTRACTOR SHALL PAY CLOSE ATTENTION TO EXISTING UTILITIES WITHIN THE ANY ROAD RIGHT OF WAY DURING CONSTRUCTION. 7. CONTRACTOR MUST PROTECT THE PUBLIC AT ALL TIMES WITH FENCING, BARRICADES, ENCLOSURES, ETC., (AND OTHER APPROPRIATE BEST MANAGEMENT PRACTICES) AS APPROVED BY CITY AND OWNER. SHOULD REMOVAL AND/OR RELOCATION ACTIVITIES DAMAGE EXISTING FACILITIES TO REMAIN, THE CONTRACTOR SHALL PROVIDE NEW MATERIALS/ STRUCTURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. EXCEPT FOR MATERIALS DESIGNED TO BE RELOCATED ON THIS PLAN, ALL OTHER CONSTRUCTION MATERIALS SHALL BE NEW.DAMAGE TO ALL EXISTING CONDITIONS TO REMAIN WILL BE REPLACED AT CONTRACTOR'S EXPENSE. 8. CONTRACTOR SHALL LIMIT SAW-CUT & PAVEMENT REMOVAL TO ONLY THOSE AREAS WHERE IT IS REQUIRED AS SHOWN ON THESE CONSTRUCTION PLANS, BUT IF ANY DAMAGE IS INCURRED ON ANY OF THE SURROUNDING PAVEMENT, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR IT'S REMOVAL AND REPAIR. 9. IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT THE VARIOUS UTILITY COMPANIES WHICH MAY HAVE BURIED OR AERIAL UTILITIES WITHIN OR NEAR THE CONSTRUCTION AREA BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PROVIDE 72 HOURS MINIMUM NOTICE TO ALL UTILITY COMPANIES PRIOR TO BEGINNING CONSTRUCTION. 10. ALL EXISTING UTILITIES SHOWN ARE LOCATED ACCORDING TO THE INFORMATION AVAILABLE TO THE ENGINEER AT THE TIME THE DRAWINGS WERE PREPARED AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER. GUARANTEE IS NOT MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN OR THAT THE LOCATION OF THOSE SHOWN ARE ACCURATE. FINDING THE ACTUAL LOCATION OF ANY EXISTING UTILITIES IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE DONE BEFORE HE COMMENCES ANY WORK IN THE VICINITY. FURTHERMORE, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY AND ALL DAMAGE DUE TO THE CONTRACTORS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. THE OWNER OR ENGINEER WILL ASSUME NO LIABILITY FOR ANY DAMAGES SUSTAINED OR COST INCURRED BECAUSE OF THE OPERATIONS IN THE VICINITY OF EXISTING UTILITIES OR STRUCTURES, NOR FOR TEMPORARY BRACING AND SHORING OF SAME. IF IT IS NECESSARY TO SHORE, BRACE, SWING OR RELOCATE A UTILITY, THE UTILITY COMPANY OR DEPARTMENT AFFECTED SHALL BE CONTACTED BY THE CONTRACTOR AND THEIR PERMISSION OBTAINED REGARDING THE METHOD TO USE FOR SUCH WORK. 11. THE CONTRACTOR SHALL HAVE AVAILABLE AT THE JOB SITE AT ALL TIMES ONE COPY OF THE CONTRACT DOCUMENTS INCLUDING PLANS, SPECIFICATIONS, COPIES OF ANY REQUIRED CONSTRUCTION PERMITS, AND EROSION CONTROL PLANS AND INSPECTION REPORTS (SWPPP). 12. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER/ENGINEER BEFORE COMMENCING WORK. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN ARE TO BE MADE WITHOUT PRIOR APPROVAL OF THE OWNER AND NOTIFICATION TO THE ENGINEER. NO CONSIDERATION WILL BE GIVEN TO CHANGE ORDERS FOR WHICH THE OWNER AND ENGINEER WERE NOT CONTACTED PRIOR TO CONSTRUCTION OF THE AFFECTED ITEM. 13. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH THE LATEST OSHA STANDARDS FOR EXCAVATION AND TRENCHING PROCEDURES. CONTRACTOR SHALL USE SUPPORT SYSTEMS, SLOPING, BENCHING, ETC. AS NECESSARY FOR THESE OPERATIONS, AND SHALL COMPLY WITH ALL OSHA PERFORMANCE CRITERIA. 14. DO NOT INTERRUPT EXISTING UTILITIES SERVICING FACILITIES OCCUPIED AND USED BY THE OWNER OR OTHERS DURING OCCUPIED HOURS EXCEPT WHEN SUCH INTERRUPTIONS HAVE BEEN AUTHORIZED IN WRITING BY THE OWNER AND THE LOCAL MUNICIPALITIES. INTERRUPTIONS SHALL ONLY OCCUR AFTER ACCEPTABLE TEMPORARY SERVICE HAS BEEN PROVIDED. 15. ANY RECYCLED MATERIAL TO BE STOCKPILED ON THE SITE SHALL BE STORED IN AS SMALL AN AREA AS PRACTICAL AND THE LOCATION OF ANY STOCKPILE SHALL BE WELL CLEAR OF THE BUILDING PAD AREA AND THE LOCATION MUST BE PRE-APPROVED BY THE ENGINEER AND OWNER PRIOR TO STOCKPILING. 16. QUANTITIES SHOWN HERE ARE APPROXIMATE AND ARE PROVIDED FOR CONVENIENCE ONLY AND NOT FOR BID PURPOSES. CONTRACTOR SHALL VERIFY QUANTITIES NECESSARY TO DEMO FACILITIES SHOWN. 17. ASBESTOS OR HAZARDOUS MATERIAL, IF FOUND ON SITE, SHALL BE REMOVED BY A LICENSED HAZARDOUS MATERIAL CONTRACTOR. REFERENCE ARCHITECTURAL PLANS FOR LIMITS OF BUILDING DEMOLITION. PARKING INFORMATION **TOTAL PARKING PROVIDED TOTAL PARKING RATIO BUILDING SQ. FT.SPACES SPACES APPROX. 143,523 SF (EXISTING)837 SPACES (EXISTING)5.83/1,000 SF OF BUILDING AREA APPROX. 144,877 SF (PROPOSED)822 SPACES (PROPOSED)5.67/1,000 SF OF BUILDING AREA PROPOSED PARKING INCLUDES 10 PICKUP STALLS *EXISTING BUILDING SQUARE FOOTAGE FROM WALMART'S ELECTRONIC OWNER'S MANUAL **PARKING COUNT IS FROM WALMART'S ELECTRONIC OWNER'S MANUAL AND DOES NOT INCLUDE CART CORRALS *** ALL OGP PARKING STALLS TO BE A MINIMUM OF 10'X20' (12' O.C.). PICKUP STALLS TO MATCH TYPICAL DIMENSIONS SHOWN ON PLAN. SITE PLAN SCHEDULE NOTES SITE LEGEND SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C1 - Demo and Site Plan - 2019-02-11 - Ryan James 31 32 SD 33 34 35 36 RECEIVED 06/09/2020 amorganroth PLANNING DIVISION EXHIBIT 3 DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 1 2 2 1 1 1 inch = 60 ft. ( IN FEET ) GRAPHIC SCALE 060 60 120 24030 PROPOSED OGP PICK-UP SIGNAGE, RIGHT. SEE DETAIL SHEET C3. PROPOSED OGP PICK-UP SIGNAGE, LEFT. SEE DETAIL SHEET C3. SIGNAGE & STRIPING SCHEDULE NOTES SITE SIGNAGE NOTES 1. THIS PLAN WAS PREPARED BASED ON THE ORIGINAL CONSTRUCTION PLANS PREPARED BY PACLAND, DATED 05/09/2014. THIS PLAN IS FOR ILLUSTRATIVE PURPOSES ONLY. ACTUAL FIELD CONDITIONS MAY VARY SIGNIFICANTLY FROM THIS DRAWING. 2. REFERENCE SITE DETAILS FOR SIGN LOCATION & VESTIBULE CROSSWALK DETAILS FOR SITE SIGNAGE OFFSETS. SITE SIGNAGE LEGEND PROPERTY LINE PROPOSED PATH OF TRAVEL FOR PICKUP CUSTOMER. PROPOSED PICKUP AREA 1 2 H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C2 - Site Signage Plan - 2019-02-11 - Ryan James SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMPNOTFORCONS TRUCTIONDocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 FINISH LEGEND P76 WALMART BLUE P5E SAFETY YELLOW SIGNS FURNISHED BY WALMART ATTACH TO WALL OR BOLLARD BY G.C. Stall Designation Signs 18" x 18" Logo Signs (Small) 18" x 8" Call In Sign 18" x 8" Logo Signs (Large) 36" x 18" Directional Signs (Left / Straight / Right) 18" x 24" Also Pickup Hours sign size NTD: Use if AHJ does not allow Spark 3.00 SF 1.00 SF 4.50 SF 1.00 SF 3.00 SF Parking Stall Placard SEE REMOVABLE SQUARE TUBE POST 3000 P.S.I. P.C. CONCRETE BASE SLOPE TOP OF CONCRETE GALVANIZED SQUARE TUBE GROUND SURFACE TYPICAL DIRECTIONAL SIGNAGE IN CURBED ISLAND USE 4" SCH. 40 STEEL PIPE FILLED W/ CONCRETE WITH TOP ROUNDED AND PAINTED TRAFFIC YELLOW TYPICAL DIRECTIONAL SIGNAGE IN PAVEMENT 3000 P.S.I. P.C. CONCRETE BASE SLOPE TOP OF CONCRETE GALVANIZED SQUARE TUBE GROUND SURFACE 2'-0"1'-0"1'-0"2'-0"4'-0"MAXNOTES: 1. ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES", LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. SIGN LOCATIONS - 90° PARKING CURBED ISLAND - 90° POST WITH SIGN(S) LAYOUT PER STRIPING DETAIL/SITE PLAN EQ EQ 4'-0"SIGN LOCATIONS - 90° PARKING PAINTED ENDCAP - 90° POST WITH SIGN(S) LAYOUT PER STRIPING DETAIL/SITE PLAN NEVER LESS THAN 9' (UNLESS STOP SIGN IS USED) EQ EQ 4'-0"DRIVEN DIRECTLY INTO GROUND GROUND SURFACE TYPICAL DIRECTIONAL SIGNAGE DRIVEN DIRECTLY INTO GROUND4'-0"MAX2'-0"2'-6"4'-0"MAXTYPICAL PARKING SIGNAGE IN PAVEMENT 3000 P.S.I. P.C. CONCRETE BASE SLOPE TOP OF CONCRETE GROUND SURFACE U-BOLT NUT LOCATIONS ADDITIONAL SPARK PICKUP SIGN ON BACK WHEN BACK FACES PUBLIC STREET. ALIGN TO TOP. BOLT LOCATIONS PER STANDARD WITH SPACER AS FOR LEVEL SIGN MOUNTING 1'-0"2'-6"1'-0" BEGIN NUMBERING AT STALL CLOSEST TO THE PICKUP DOOR.2'-0"6'-2"1'-0"1'-0" 3000 P.S.I. P.C. CONCRETE BASE SLOPE TOP OF CONCRETE GROUND SURFACE U-BOLT 2'-0"6'-2"FRONT VIEW SIDE VIEW USE 4" SCH. 40 STEEL PIPE FILLED W/ CONCRETE WITH TOP ROUNDED AND PAINTED TRAFFIC YELLOW "K" SIGN HOSE CLAMP PLAN VIEW PARTIAL ELEVATION GROUND SURFACE 5/16" GR. 5 FLANGED BOLT 5/16" GR. 5 SERRATED FLANGED NUT REMOVABLE SQUARE TUBE POST NOTES: 1. ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES", LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. GALVANIZED SQUARE TUBE POST TUBES - 2"x2"x3/16" 12ga POST TUBE GALVANIZED AS PER ASTM A653 GRADE 90. ANCHOR TUBE - 2-1/4"x2-1/4"x3/16" 12ga HEAVY DUTY ANCHOR TUBE SHALL MEET ASTM A500 GRADE B. STRUCTURAL TUBE AND STEEL SHALL BE HOT DIP GALVANIZED PER ASTM A123. THE UPPER SIGN POST SHALL TELESCOPE INSIDE THE ANCHOR TUBE A MINIMUM OF 12". THE ANCHOR TUBE SHALL BE A MINIMUM 27" DEEP WITH 3" MIN. 4" MAX. EXPOSED ABOVE FINISH GRADE. P.C.CONC. 12" SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C3-C4 - City Standard Details - 2019-02-11 - Ryan James PAINTED TRAFFIC WHITE 6" TYP 2'-0" TYP SINGLE POST WITH BOLLARD SIGN LOCATIONS - 60° PARKING PAINTED ENDCAP - 60° SIGN LOCATIONS - 90° PARKING PAINTED ENDCAP - 90° SQUARE TUBE BREAK AWAY POST PLAN VIEW PARTIAL ELEVATION SURFACE SINGLE POST WITH BREAK AWAY POST SIGN LOCATIONS - 60° PARKING CURBED ISLAND - 60° SIGN LOCATIONS - 90° PARKING CURBED ISLAND - 90° N.T.S. SIGN MOUNTING AND BASE OR OR NO SIGNS SHALL BE LOCATED WITHIN SHADED AREAS SHOWN IN DETAILS NOTE: ALL SIGNS LOCATED ON THE BUILDING SIDE OF THE BFR ARE TO BE INSTALLED ON A SINGLE POST WITH BOLLARD. NOTE: SIGNS SHALL HAVE DIAMOND GRADE, ASTM TYPE XI, SHEETING. NOTES FOR SINGLE POST WITH BOLLARD: 1.ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES", LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2.GALVANIZED SQUARE TUBE POST TUBES - 2"X2" 12ga POST TUBE SHALL MEET ASTM A1011 GRADE 50. POST TUBE GALVANIZED AS PER ASTM A653 GRADE 90.EDGEOFTRAVELWAYPAVED SURFACE NOTES FOR SINGLE POST WITH BREAK AWAY POST: 1.ALL SIGNS SHALL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION'S "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES", LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2.GALVANIZED SQUARE TUBE POST TUBES - 2"X2" 12ga POST TUBE SHALL MEET ASTM A1011 GRADE 50. POST TUBE GALVANIZED AS PER ASTM A653 GRADE 90. ANCHOR TUBE - 2-1/4"x2-1/4" 12ga HEAVY DUTY ANCHOR TUBE SHALL MEET ASTM A500 GRADE B. STRUCTURAL TUBE AND STEEL SHALL BE HOT DIP GALVANIZED PER ASTM A123. THE UPPER SIGN POST SHALL TELESCOPE INSIDE THE ANCHOR TUBE A MINIMUM OF 12". THE ANCHOR TUBE SHALL BE A MINIMUM 27" DEEP WITH 3" MIN. 4" MAX. EXPOSED ABOVE FINISH GRADE. 18"Ø4'-0"4'-0"3'-0"7'-0"(MIN.)GALVANIZED SQUARE TUBE USE 4" SCH. 40 STEEL PIPE FILLED W/ CONCRETE WITH TOP ROUNDED AND PAINTED TRAFFIC YELLOW SLOPE TOP OF CONCRETE 3500 P.S.I. P.C. CONCRETE BASE EDGEOFTRAVELWAY4'-0"7'-0"(MIN.)NOTE: THE MIN. HEIGHT OF THE BOTTOM OF THE LOWEST SIGN SHALL BE 7'-0" GALVANIZED SQUARE TUBE SLOPE TOP OF CONCRETE 3500 P.S.I. P.C. CONCRETE BASE SEE BREAK AWAY TUBE POST 12"Ø27"GROUND SURFACE 3"MIN.-4"MAX.5/16" GR. 5 SERRATED FLANGED NUT 5/16" GR. 5 FLANGED BOLT 4'-0" NEVER LESS THAN 9' (UNLESS STOP SIGN IS USED)4'-0"VARIESDEPENDINGONCURBRADIUS4'-0" NEVER LESS THAN 9' (UNLESS STOP SIGN IS USED)4'-0"VARIESDEPENDINGONCURBRADIUSLAYOUT PER STRIPING DETAIL/SITE PLANLAYOUT PER STRIPING DETAIL/SITE PLAN 30" "STOP" SIGN MOUNTED TO POST WITH BREAK AWAY POST 36" "STOP" SIGN SHALL BE INSTALLED ON POST WITH BOLLARD 30" "STOP" SIGN MOUNTED TO POST WITH BREAK AWAY POST 36" "STOP" SIGN SHALL BE INSTALLED ON POST WITH BOLLARD "STOP FOR PEDESTRIAN" SIGN ON POST (ALL SIGNS EQUAL TO OR GREATER THAN 36" IN WIDTH SHALL BE MOUNTED ON POST WITH BOLLARD) "STOP FOR PEDESTRIAN" SIGN ON POST (ALL SIGNS EQUAL TO OR GREATER THAN 36" IN WIDTH SHALL BE MOUNTED ON POST WITH BOLLARD) NEVER LESS THAN 9' (UNLESS STOP SIGN IS USED) NEVER LESS THAN 9' (UNLESS STOP SIGN IS USED) LAYOUT PER STRIPING DETAIL/SITE PLAN LAYOUT PER STRIPING DETAIL/SITE PLAN 4'-0"4'-0""STOP" SIGN ONLY - ON POST WITH BOLLARD 4'-0"4'-0"4'-0"4'-0""STOP FOR PEDESTRIAN" SIGN ON POST WITH BOLLARD "STOP FOR PEDESTRIAN" SIGN ON POST WITH BOLLARD "STOP" SIGN ONLY - ON POST WITH BOLLARD NOTE: THE MIN. HEIGHT OF THE BOTTOM OF THE LOWEST SIGN SHALL BE 7'-0" NO SIGNS SHALL BE LOCATED WITHIN SHADED AREAS SHOWN IN DETAILS NO SIGNS SHALL BE LOCATED WITHIN SHADED AREAS SHOWN IN DETAILS NO SIGNS SHALL BE LOCATED WITHIN SHADED AREAS SHOWN IN DETAILS GROUND NOTE: SIGNS SHALL HAVE DIAMOND GRADE, ASTM TYPE XI, SHEETING. 10'-0" TYP G.C. TO SEAL COAT STRIPING PER SPEC SECTION 02787 ℄℄ 2'-0" TYP 12'-0" TYP N.T.S. STOP FOR PEDESTRIANS LEGEND, BORDER - BLACK BACKGROUND - WHITE (RETROREFLECTIVE) STOP SYMBOL - RED (RETROREFLECTIVE) R1-5b NOTE: SIGNS SHALL HAVE DIAMOND GRADE, ASTM TYPE XI, SHEETING. DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 ARROWS SHALL BE PAINTED , TYPSEE SITE PLAN FOR TYPE OF ARROW (RIGHT, LEFT OR AHEAD) P126 NOTE: PAVEMENT MARKING SHALL MEET UNISPEC SECTION 02765 - PAVEMENT MARKING G.C. TO ORDER SIGN STENCILS FROM JONATHON THOMPSON AT OUTLINE INDUSTRIES OR CALL 1.800.STENCILS SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C3-C4 - City Standard Details - 2019-02-11 - Ryan James UTILITY TRENCH DETAIL NTS PLAN VIEW SECTION A-A A CONCRETE SIDEWALK B B A SECTION B-B DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 27.05 26.97 TBC27.47 FL26.97 FFE27.55 TBC27.47 FL26.978.33%3.01%2.62%3.60%27 FFE27.55 27.55 2.00% FFE27.55 SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP KEY MAP NOT TO SCALE ME 30.00 25 27 29 FL TBC FFE 1 inch = 20 ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 8010 SITE GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. NOTE: CONTRACTOR RESPONSIBLE FOR AS-BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION AT THEIR COST. GRADING NOTES 1. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 2. REQUIREMENTS SHOWN ON SITE PLAN SHALL GOVERN. DRAWINGS AND SPECIFICATIONS SHOWING OTHERWISE NOTWITHSTANDING. CONTRACTOR TO POINT OUT ANY DISCREPANCIES TO THE OWNERS REPRESENTATIVE PRIOR TO BID. 3. CONTRACTOR MUST OBTAIN ALL STATE AND CITY STORM WATER DISCHARGE AND EROSION CONTROL PERMITS PRIOR TO ANY DISTURBANCE AND/OR GRADING ACTIVITY. 4. ALL CUT OR FILL SLOPES SHALL BE 4:1 OR FLATTER UNLESS OTHERWISE NOTED. 5. EXISTING GRADE CONTOURS SHOWN AT 1 FOOT INTERVALS. 6. PROPOSED GRADE CONTOURS SHOWN AT 1 FOOT INTERVALS. 7. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR AND//OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 8. THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL NPDES PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE WALMART SPECIAL CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION. THIS APPLIES TO WALMART BUILT PROJECTS ONLY. 9. CONTRACTORS SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. 10. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS. 11. TOPOGRAPHIC INFORMATION IS TAKEN FROM A TOPOGRAPHIC SURVEY BY LAND SURVEYORS. IF THE CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER FOR REVIEW. 12. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED. 13. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME. 14. GC TO MAINTAIN EGRESS PATH AND FIRE LANE DURING CONSTRUCTION WHEN WORK IS NOT BEING CONDUCTED. LIMIT DISRUPTION OF EXIT AND FIRE LANE DURING CONSTRUCTION. IF WORK REQUIRES THE BLOCKAGE OF THE DOOR OR FIRE LANE, NOTIFY THE STORE MANAGER AND COORDINATE WITH THE FIRE DEPARTMENT. 15. THIS DESIGN IS BASED ON A PREVIOUS SOIL AND FOUNDATION INVESTIGATION. A COPY OF THIS REPORT IS AVAILABLE FOR INSPECTION BY THE CONTRACTORS. 16. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MINIMIZING DEPOSITION OF ONSITE SEDIMENTS ONTO SURROUNDING PUBLIC STREETS DURING CONSTRUCTION. 17. GENERAL CONTRACTOR TO PROVIDE BARRICADE PROTECTION WITH FLASHING LIGHTS AROUND ALL FOOTINGS, EXCAVATIONS AND ALL OFFSITE WORK. 18. CONTRACTOR RESPONSIBLE FOR ALL WORK NECESSARY FOR FINAL ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY, INCLUDING BUT NOT LIMITED TO AS-BUILT DRAWINGS, INSPECTIONS, TESTING REPORTS AND CERTIFICATIONS. 19. ELEVATIONS FOR THE SITE WERE ESTABLISHED USING NAVD88 VERTICAL DATUM. GRADING LEGEND OGP ENTRANCE/EXIT ENLARGMENT SCALE: 1" = 5' H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C5 - Grading Plan - 2019-02-11 - Ryan James EXISTING BUILDING TO REMAIN EXISTING BOLLARD TO REMAIN EXISTING FENCE TO REMAIN EXISTING CURB & GUTTER TO REMAIN EXISTING STORM INLET TO REMAIN EXISTING SIGN TO REMAIN EXISTING SITE LIGHTING TO REMAIN EXISTING SITE LIGHTING TO BE RELOCATED EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING FIRE HYDRANT TO BE RELOCATED PROPOSED PICK-UP SIGN PROPOSED CURB AND GUTTER PROPOSED SAWCUT LINE PROPOSED OGP CANOPY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED CONTOUR PROPOSED SPOT ELEVATION MATCH EXISTING FLOWLINE TOP BACK OF CURB FINISHED FLOOR ELEVATION X X Y SD DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP KEY MAP NOT TO SCALE 1 inch = 20 ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 8010 SITE LEGEND SITE GENERAL CONTRACTOR'S SURVEYOR SHALL VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. NOTE: CONTRACTOR RESPONSIBLE FOR AS-BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION AT THEIR COST. EXISTING 12" WATER MAIN SECTION TO BE REMOVED. EXISTING 6" WATER PIPE SECTION TO BE REMOVED. EXISTING LIGHT POLE TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION. EXISTING FIRE HYDRANT ASSEMBLY TO BE RELOCATED. SALVAGE EXISTING HYDRANT AND REUSE. PROPOSED 45° BEND W/ THRUST BLOCK PER CITY OF RENTON STANDARDS AND DETAILS. PROPOSED 12"x12"x6" TEE W/ THRUST BLOCK PER CITY OF RENTON STANDARDS AND DETAILS. PROPOSED FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STANDARDS AND DETAILS. REUSE EXISTING HYDRANT. PROPOSED 12" WATER MAIN PER CITY OF RENTON STANDARDS AND DETAILS. PROPOSED LOCATION OF RELOCATED SITE LIGHT. PROPOSED UNDERGROUND ELECTRICAL LINE. CONTRACTOR TO BORE NEW LINE FROM EXISTING LIGHT POLE LOCATION TO PROPOSED NEW LIGHT POLE. CONDUIT TO CANOPY. SEE ELECTRICAL PLAN. EXISTING 15' UTILITY EASEMENT (REC NO. 9704011446) PROPOSED 15' UTILITY EASEMENT PROPOSED 10' UTILITY EASEMENT EXISTING 15' UTILITY EASEMENT TO BE VACATED EXISTING STORM SEWER TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING STORM INLET TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING STORM VAULT TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING WATER MAIN TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING WATER MANHOLE TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING GAS LINE TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION EXISTING WATER VALVE TO BE REMOVED PROPOSED CONNECTION TO EXISTING 12" WATER MAIN EXISTING STORM SEWER TO BE REMOVED PROPOSED STORM SEWER PIPE, MATCH EXISTING ROOF DRAIN DIA. EXISTING FOUNDATION DRAIN TO REMAIN EXISTING FOUNDATION DRAIN TO BE REMOVED PROPOSED FOUNDATION DRAIN CONNECT PROPOSED FOUNDATION DRAIN INTO EXISTING STORM DRAIN. PROPOSED 4' DIA. MANHOLE. 1 UTILITY PLAN SCHEDULE NOTES 2 3 4 5 6 7 8 UTILITY NOTES 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH-ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 3. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 4. GATE VALVES SHALL BE IRON BODY, BRONZED-MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 5. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 6. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 7. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 8. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 9. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 10. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 11. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 12. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING PIGS PRIOR TO DISINFECTION. THE POLY PIGS SHALL BE GIRARD INDUSTRIES AQUA SWAB-AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF PIG ONLY. 13. PIGS SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 14. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 15. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 16. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS-BUILT DRAWINGS. 17. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 18. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_C6 - Utility Plan - 2019-02-11 - Ryan James 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 EXISTING BUILDING TO REMAIN EXISTING BOLLARD TO REMAIN EXISTING FENCE TO REMAIN EXISTING CURB & GUTTER TO REMAIN EXISTING STORM INLET TO REMAIN EXISTING SIGN TO REMAIN EXISTING SITE LIGHTING TO REMAIN EXISTING SITE LIGHTING TO BE RELOCATED EXISTING STORM SEWER MANHOLE TO REMAIN EXISTING FIRE HYDRANT TO BE RELOCATED PROPOSED FIRE HYDRANT EXISTING CONCRETE PAVEMENT EXISTING ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT PROPOSED ASPHALT PAVEMENT PROPOSED PICK-UP SIGN PROPOSED CURB AND GUTTER PROPOSED SAWCUT LINE PROPOSED OGP CANOPY X X Y SD 24 25 26 27 28 SS W STS G SS EXISTING SANITARY SEWER PROPOSED STORM SEWER PROPOSED SANITARY SEWER EXISTING GAS LINE EXISTING WATER LINE TO REMAIN UTILITY LEGEND W EXISTING WATER LINE TO REMAIN W PROPOSED WATER LINE STS PROPOSED STORM SEWER TO BE REMOVED STS PROPOSED STORM SEWER TO REMAIN 29 30 DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25 SHEET JOB No. SCALE DATE CHECKED DRAWN REVISIONS BY RHA002516.20 05/11/20 AS NOTED JES DMP 1 inch = 50 ft. ( IN FEET ) GRAPHIC SCALE 050 50 100 20025 H:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\CADD\3 CD\RHA2516_L1.0 - Landscape - 2019-02-11 - Ryan James EXISTING PLANT LEGEND EXISTING DECIDUOUS TREES TO BE REMOVED EXISTING DECIDUOUS TREES TO REMAIN TO REMAIN TO REMOVE =5=115 TREE REMOVAL LEGEND 1 COMMON NAMESCIENTIFIC NAMETREE NUMBER CONDITION GOOD 2 GOOD 3 4 5 LIQUIDAMBER STYRACIFLUA 'PALO ALTO"PALO ALTO SWEETGUM CALIPER INCHES 7"-8" 6"-7" 3"-4" 6"-7" OTHER COMMENTSACTION REMOVE REMOVE REMOVE LOCATION AND SIZE TO BE VERIFIED 1. USE RENTON, WASHINGTON TREE PROTECTION CODE (IF AVAILABLE). TREE PROTECTION NOTES BELOW SHALL BE USED FOR FURTHER INTEGRATION. 2. "PROTECTED ZONE" FOR EXISTING TREES: BEFORE BEGINNING ANY DEMOTION OR CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND ALL EXISTING TREES WITHIN THE CONSTRUCTION ZONE THAT ARE TO BE SAVED. THE FENCE SHALL BE INSTALLED NO CLOSER TO THE TREE THAN THE EDGE OF THE TREE'S PROTECTED ZONE, GENERALLY DEFINED AS THE AREA BEGINNING FIVE FEET OUTSIDE OF THE TREE'S DRIPLINE AND EXTENDING TOWARDS THE TREE (OR AS FAR AWAY FROM THE TRUNK AS PRACTICABLE). THE FENCING SHALL BE OF A MATERIAL AND HEIGHT ACCEPTABLE TO THE LANDSCAPE ARCHITECT. ALL CONTRACTORS AND THEIR CREWS SHALL NOT BE ALLOWED INSIDE THIS "PROTECTED ZONE" NOR SHALL THEY BE ALLOWED TO STORE OR DUMP FOREIGN MATERIALS WITHIN THIS AREA. NO WORK OF ANY KIND, INCLUDING TRENCHING, SHALL BE ALLOWED WITHIN THE PROTECTED ZONE EXCEPT AS DESCRIBED BELOW. THE FENCING SHALL REMAIN AROUND EACH TREE TO BE SAVED UNTIL THE COMPLETION OF CONSTRUCTION OPERATIONS. 3. TEMPORARY MULCH: TO ALLEVIATE SOIL COMPACTION IN ANTICIPATED AREAS OF HIGH CONSTRUCTION TRAFFIC, AND ONLY WHERE FENCING CANNOT BE SET FIVE FEET OUTSIDE OF THE DRIPLINE, THE CONTRACTOR SHALL INSTALL A LAYER OF MULCH, 9"-12" THICK, OVER ALL EXPOSED EARTH FROM THE TREE TRUNK TO 5' OUTSIDE OF THE DRIPLINE. THIS LAYER SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. WHEN PLANTING OPERATIONS ARE COMPLETED, THE MULCH SHALL BE REDISTRIBUTED THROUGHOUT ALL PLANTING AREAS IN A 3" THICK "PERMANENT" MULCH LAYER. 4. NECESSARY WORK: WHEN IT BECOMES NECESSARY TO ENTER THE "PROTECTED ZONE", SUCH AS FOR FINE GRADING, IRRIGATION INSTALLATION, AND PLANTING OPERATIONS, THE CONTRACTOR SHALL STRICTLY ADHERE TO THE FOLLOWING RULES: A. EVERY EFFORT SHALL BE MADE TO PRESERVE THE EXISTING GRADE AROUND PROTECTED TREES IN AS WIDE AN AREA AS POSSIBLE. B. TRENCHING WITHIN THE PROTECTED ZONE OF EXISTING TREES SHALL BE PERFORMED BY HAND, AND WITH EXTREME CARE NOT TO SEVER ROOTS 1-1/2" IN DIAMETER AND LARGER. WHERE ROOTS 1-1/2" IN DIAMETER AND LARGER ARE ENCOUNTERED, THE CONTRACTOR SHALL TUNNEL UNDER SAID ROOTS. EXPOSED ROOTS THAT HAVE BEEN TUNNELED UNDER SHALL BE WRAPPED IN WET BURLAP AND KEPT MOIST WHILE THE TRENCH IS OPEN. C. WHERE ROOTS 1-1/2" IN DIAMETER OR LARGER MUST BE CUT DUE TO EXTENSIVE GRADE CHANGES, THOSE ROOTS MUST BE EXPOSED BY HAND DIGGING AND CUT CLEANLY. RAGGED CUTS GENERALLY DO NOT HEAL PROPERLY, AND MAY LEAVE THE TREE OPEN TO PESTS AND PATHOGENS. D. WHERE TRENCHING NEAR TREES HAS ALREADY OCCURRED FROM PREVIOUS CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL MAKE EVERY EFFORT TO CONFINE HIS TRENCHING OPERATIONS TO THE PREVIOUSLY-CREATED TRENCHES, WHILE ADHERING TO THE CONDITIONS SET FORTH IN 3B. 4. POTENTIAL CONFLICTS: THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARBORIST SHOULD ANY POTENTIAL CONFLICTS ARISE BETWEEN THESE SPECIFICATIONS AND/OR LARGE ROOTS ENCOUNTERED IN THE FIELD, AND CONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL NOT TAKE ANY ACTION IN SUCH CONFLICTS WITHOUT THE ARBORIST'S WRITTEN APPROVAL. THE ARBORIST SHALL HAVE FINAL AUTHORITY OVER ALL METHODS NECESSARY TO HELP ENSURE THE PROTECTION AND SURVIVAL OF EXISTING TREES. 5. PRUNING: PRUNE ONLY THE TREES THAT ARE INDICATED ON THE PLANS AS REQUIRING PRUNING. PRUNE TREES ACCORDING TO INTERNATIONAL SOCIETY OF ARBORICULTURE / ANSI A300 STANDARDS: A. REMOVE ALL DEAD WOOD. B. PRUNE LIVE WOOD FOR HEALTH OR STRUCTURAL REASONS ONLY, INCLUDING THE NEED TO ELIMINATE DISEASED OR DAMAGED GROWTH, ELIMINATE STRUCTURALLY UNSOUND GROWTH, REDUCE THE POTENTIAL FOR WIND TOPPLING OR WIND DAMAGE, OR TO MAINTAIN GROWTH WITHIN LIMITED SPACE. DO NOT REMOVE MORE THAN 25% OF ANY TREE'S LIVE FOLIAGE IN ANY ONE GROWING SEASON. PRUNE ONLY TO INTERNATIONAL SOCIETY OF ARBORICULTURE/ANSI A300 STANDARDS, AND ONLY UNDER THE DIRECT SUPERVISION OF A CERTIFIED ARBORIST. C. FINAL CUTS SHALL BE MADE JUST OUTSIDE THE SHOULDER RING AREA. EXTREMELY FLUSHED CUTS WHICH PRODUCE LARGE WOUNDS SHALL NOT BE MADE. D. ALL TRIMMING CUTS SHALL BE PERFORMED IN SUCH A MANNER AS TO PROMOTE THE NATURAL GROWTH AND SHAPE OF EACH TREE SPECIES. E. IMPROPER PRUNING METHODS INCLUDING, BUT NOT LIMITED TO, "TOPPING", "TIPPING", "HEADING BACK", "DEHORNING", AND "LIONTAILING" WILL NOT BE ALLOWED. THE CONTRACTOR SHALL PAY FOR ALL WORK NECESSARY TO CORRECT SUCH PRUNING WHEN PERFORMED BY HIS CREWS OR SUBCONTRACTORS. F. SHOULD THE CONTRACTOR REQUIRE MORE INFORMATION, THE CONTRACTOR SHALL CONTACT THE ISA AT (217) 355-9411 FOR A COPY OF THE ANSI A300 PRUNING STANDARDS. CONTRACTOR SHALL ADHERE TO THE METHODS AND PRACTICES SET FORTH IN THIS DOCUMENT. 6. LANDSCAPE AND IRRIGATION (NATIVE TREES ONLY): ANY FUTURE LANDSCAPE AND IRRIGATION SHOULD ADHERE TO THE FOLLOWING GUIDELINES: A. NO IRRIGATION OR PLANTING SHOULD OCCUR CLOSER THAN 8'-10' FROM THE TRUNK. B. WHERE IRRIGATION DOES OCCUR WITHIN THE PROTECTED ZONE, DRIP IRRIGATION SHOULD BE USED WHEREVER POSSIBLE. ADDITIONALLY, ONLY PLANTS WITH LOW WATER NEEDS SHOULD BE PLANTED WITHIN THE PROTECTED ZONE, SPACED FAR APART WHERE CLOSE TO THE TREE. PLANTS MAY BE SPACED CLOSER TOGETHER NEAR THE EDGE OF THE PROTECTED ZONE. TREE PROTECTION NOTES: REMOVE REMOVE LOCATION AND SIZE TO BE VERIFIED LOCATION AND SIZE TO BE VERIFIED LOCATION AND SIZE TO BE VERIFIED LOCATION AND SIZE TO BE VERIFIED LIQUIDAMBER STYRACIFLUA 'PALO ALTO"PALO ALTO SWEETGUM LIQUIDAMBER STYRACIFLUA 'PALO ALTO"PALO ALTO SWEETGUM LIQUIDAMBER STYRACIFLUA 'PALO ALTO"PALO ALTO SWEETGUM LIQUIDAMBER STYRACIFLUA 'PALO ALTO"PALO ALTO SWEETGUM 6"-7"GOOD GOOD GOOD DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25