HomeMy WebLinkAboutEx06_Drainage_Report6162 S. Willow Drive, Suite 320
Greenwood Village, CO 80111
303.770.8884 •GallowayUS.com
May 11th, 2020
Mr. Justin Johnson
Community & Economic Development
Civil Construction
1055 South Grady Way
Renton, WA 98057
RE: Drainage Conformance Letter for Technical Information Report – Retail Expansion –
Walmart Store #2516-240
Dear Mr. Johnson,
The purpose of this letter is to demonstrate that the drainage characteristics of the Online Grocery
Pickup (OGP) expansion improvements for the Walmart Supercenter, Store #2516 in Renton, WA is in
conformance with the Technical Information Report – Retail Expansion dated February 25th, 2010
(per stamp date) by Pac Land.
SUMMARY
The subject property is located at 743 Rainier Ave S, Renton, WA 98057, a previously developed lot
(part of the previous Walmart expansion) that consists of an existing Walmart with associated paved
parking, totaling an area of 13.65 Acres. It is bound to the north by SW 7th Street, east by Rainier Ave
S, and south & west by adjacent businesses.
The project area consists of approximately 0.33 Acres. The existing area is comprised of paved
parking lot, sidewalk, and landscape islands. Improvements to the site include the addition of an OGP
building expansion (1,350 SF), conversion of landscape islands to pavement (1,425 SF), installation of
an OGP canopy, re-striping of existing parking lot, and relocation of existing waterline and hydrant.
DRAINAGE BASIN PATTERNS
Improvements to the site will not change the existing drainage basin areas and drainage shall follow
the existing drainage patterns for basins 2a and 2b outlined in the Technical Information Report –
Retail Expansion report (Note: these areas are indicated as proposed conditions within the existing
report). Landscape areas in proposed drainage basins 2a and 2b are being modified as part of this
project and will become impervious pavement. Total additional areas for basins 2a and 2b are 949 SF
and 476 SF respectively. In addition to the changes illustrated above, 1,350 SF of existing impervious
area (sidewalk and pavement) will be removed and replaced by the proposed building expansion
within basin 2a. Roof drains from the proposed building expansion will splash to surface and follow the
existing drainage patterns.
Existing basin and Proposed Basin areas are shown in the tables on the following page.
RECEIVED
06/09/2020
amorganroth
PLANNING DIVISION
EXHIBIT 6
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Wal-Mart Stores Inc.
Walmart #2516 OGP Expansion
05-11-2020
Galloway & Company, Inc.Page 2 of 4
Existing basin areas per Technical Information Report – Retail Expansion report.
(Note: These are listed as Proposed Sub-Basins areas in Table 2 of the above-mentioned report.)
Proposed basin areas based on new construction.
SITE HYDROLOGY
Existing drainage patterns outlined in the Technical Information Report – Retail Expansion shall
remain unchanged with the current improvements.Existing basins 2a and 2b were broken down from
the existing report and runoff rates can be found below.
Proposed drainage patterns will follow the existing drainage patterns. Drainage basin 2a will maintain
the same area as noted previously, however, pervious areas (landscape island areas) will be
exchanged for impervious pavement areas and building roof area in exchange for pavement areas.
Drainage basin 2b will also maintain the same area, however, pervious area (landscape island area)
1 2a 2b 3
Roof 150,244 0 0 0
Garden
Center 0 4,701 0 0
Landscaping 0 51,795 8,783 5,112
Pavement
(PGIS)2,548 276,524 27,496 37,433
Sidewalk 0 24,430 3,560 1,927
Gravel 0 0 0 0
Total 152,792 357,450 39,839 44,472
Surface Existing Sub-Basins
1 2a 2b 3
Roof 150,244 1,350 0 0
Garden
Center 0 4,701 0 0
Landscaping 0 50,846 8,307 5,112
Pavement
(PGIS)2,548 276,333 27,972 37,433
Sidewalk 0 24,220 3,560 1,927
Gravel 0 0 0 0
Total 152,792 357,450 39,839 44,472
Surface Proposed Sub-Basins
Event Peak Q Rate (CFS)
2-year - 24 Hr 3.3167
10-year 5.113
100-year 7.0847
Ex. Basin 2a Runoff Rates
SBUH Method
Event Peak Q Rate (CFS)
2-year - 24 Hr 0.3479
10-year 0.5482
100-year 0.7686
Ex. Basin 2b Runoff Rates
SBUH Method
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Wal-Mart Stores Inc.
Walmart #2516 OGP Expansion
05-11-2020
Galloway & Company, Inc.Page 3 of 4
will be exchanged for impervious pavement areas. The changes in the proposed drainage basins
produced the following flow information.
Detailed calculations can be found in Appendix B of this Report.
RETENTION/DETENTION ANALYSIS
As dictated in the Retention/Detention System section of the Technical Information Report – Retail
Expansion, unless the 24-hour storm increases by more than 0.50 cfs from the pre-developed peak
runoff rate, the project is exempt from runoff control. Given that basin 2a only increases by 0.0056 cfs
and basin 2b only increases by 0.0029 cfs, this project is exempt under the provision.
BIOSWALE TREATMENT
The existing biofiltration swale in the northwestern portion of the site will still maintain the treatment of
the basin 2a area. As noted in the Technical Information Report – Retail Expansion report,
additional water quality was provided for the additional pavement area. This bioswale outlined in the
New PGIS section of the Technical Information Report – Retail Expansion report, shall facilitate in
providing the additional water quality. Per the existing report, the bioswale for basin 2b was
overdesigned for the required conditions and given the minimal increase in flow rates, the existing
bioswale will suffice in providing the required water quality for the proposed development.
The existing bioswale design was verified using the following parameters:
The resultant swale design requires a minimum bottom width of 7.63 feet and a minimum treatment
length of 91 feet. Given that the swale was designed with an 8 foot bottom width and a 115 foot
treatment length, with a 1.0% longitudinal slope, the swale design fits into the parameters.
Calculations showing the existing bioswale characteristics accommodating the additional flows can be
found in Appendix C.
CONCLUSIONS
Given the minor increase in flows, 0.0056 cfs for basin 2a and 0.0029 cfs for 2b, and the fact that the
bioswale can accommodate the additional flow rates as designed. The improvements outlined in this
conformance letter comply with the existing drainage report and therefore no additional modifications
are necessary.
Event Peak Q Rate (CFS)
2-year - 24 Hr 3.3223
10-year 5.1181
100-year 7.0893
Prop. Basin 2a Runoff Rates
SBUH Method
Event Peak Q Rate (CFS)
2-year - 24 Hr 0.3508
10-year 0.551
100-year 0.7712
Prop. Basin 2b Runoff Rates
SBUH Method
Criteria Value
2-yr, 24-hr flow 0.3508 cfs
Design Flow Depth 0.25 feet
Mannings Coeff 0.35
Residence Time 9 minutes
Side Slope 3.0 H:V
Bioswale Design Criteria - Single Event
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Wal-Mart Stores Inc.
Walmart #2516 OGP Expansion
05-11-2020
Galloway & Company, Inc.Page 4 of 4
Sincerely,
GALLOWAY
Brandon D. Alley, PE
Principal - Galloway US
BrandonAlley@gallowayUS.com
NOTE:
See attached documents for further drainage information:
Addendum A: Drainage Map
Addendum B: Drainage Detention Calculations
Addendum C: Bioswale Calculations
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
APPENDIX A
PROPOSED DRAINAGE MAP
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
1 inch = 60 ft.
( IN FEET )
GRAPHIC SCALE
060 60 120 24030
SHEET
JOB No.
SCALE
DATE
CHECKED
DRAWN
REVISIONS BY
RHA002516.20
05/11/20
AS NOTED
JES
DMPNOTFORCONS TRUCTIONH:\RHA\WA, Renton - RHA002516.20 - 743 Rainier Ave. S\3 Permit CDs\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\RHA2516_Drainage Map - 2019-02-11 - Ryan James
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
APPENDIX B
DRAINAGE DETENTION CALCULATIONS
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Appended on: Wednesday, May 29, 2019 8:29:09 PM
Ex Basin 2a Event Summary
Record Id: Ex Basin 2a
Licensed to: Engenious Systems, Inc.
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 3.3167 8.00 1.0941 8.21 SBUH
10 year 5.113 8.00 1.6972 8.21 SBUH
100 year 7.0847 8.00 2.3738 8.21 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 8.21 ac DCIA 0.00 ac
Pervious CN 96.26 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)7.02 ac 98.00
Open spaces, lawns,parks (>75% grass)1.19 ac 86.00
Pervious Composited CN (AMC 2)96.2607
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces.30.00 ft 2.0%0.011 0.00 in 0.585 min
Int Channel CMP pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.8052 min
Page 1 of 1
5/29/2019file:///C:/Users/sid_biddle/Stormshed/StormShed3G/Basin%202a.html
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Appended on: Wednesday, May 29, 2019 8:33:27 PM
Ex Basin 2b Event Summary
Record Id: Ex Basin 2b
Licensed to: Engenious Systems, Inc.
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 0.3479 8.00 0.1149 0.91 SBUH
10 year 0.5482 8.00 0.1811 0.91 SBUH
100 year 0.7686 8.00 0.2557 0.91 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 0.91 ac DCIA 0.00 ac
Pervious CN 95.36 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)0.71 ac 98.00
Open spaces, lawns,parks (>75% grass)0.20 ac 86.00
Pervious Composited CN (AMC 2)95.3626
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces.30.00 ft 2.0%0.011 0.00 in 0.585 min
Int Channel CMP pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.8052 min
Page 1 of 1
5/29/2019file:///C:/Users/sid_biddle/Stormshed/StormShed3G/Basin%202a.html
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Appended on: Wednesday, May 29, 2019 8:35:46 PM
Pro Basin 2b Event Summary
Record Id: Pro Basin 2b
Licensed to: Engenious Systems, Inc.
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 3.3223 8.00 1.096 8.21 SBUH
10 year 5.1181 8.00 1.6993 8.21 SBUH
100 year 7.0893 8.00 2.376 8.21 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 8.21 ac DCIA 0.00 ac
Pervious CN 96.29 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)7.04 ac 98.00
Open spaces, lawns,parks (>75% grass)1.17 ac 86.00
Pervious Composited CN (AMC 2)96.2899
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces.30.00 ft 2.0%0.011 0.00 in 0.585 min
Int Channel CMP pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.8052 min
Page 1 of 1
5/29/2019file:///C:/Users/sid_biddle/Stormshed/StormShed3G/Basin%202a.html
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
Appended on: Wednesday, May 29, 2019 8:37:33 PM
Prop Basin 2a Event Summary
Record Id: Prop Basin 2a
Licensed to: Engenious Systems, Inc.
Event Peak Q (cfs)Peak T (hrs)Hyd Vol (acft)Area (ac)Method
2 yr 24 hr 0.3508 8.00 0.1158 0.91 SBUH
10 year 0.551 8.00 0.1821 0.91 SBUH
100 year 0.7712 8.00 0.2568 0.91 SBUH
All results based on storm duration of 24.0 hours. This is ok if all precipitations are appropriate for the
storm duration. If some design event precipitations are for different duration storms, those results are
incorrect
Design Method SBUH Rainfall type TYPE1A.RAC
Hyd Intv 10.00 min Peaking Factor 484.00
Storm Duration 24.00 hrs Abstraction Coeff 0.20
Pervious Area 0.91 ac DCIA 0.00 ac
Pervious CN 95.49 DC CN 0.00
Pervious TC 5.00 min DC TC 0.00 min
Pervious CN Calc
Description SubArea Sub cn
Impervious surfaces (pavements, roofs, etc)0.72 ac 98.00
Open spaces, lawns,parks (>75% grass)0.19 ac 86.00
Pervious Composited CN (AMC 2)95.4945
Pervious TC Calc
Type Description Length Slope Coeff Misc TT
Sheet Smooth Surfaces.30.00 ft 2.0%0.011 0.00 in 0.585 min
Int Channel CMP pipe (n=0.024)200.00 ft 0.5%0.024 2.2202 min
Pervious TC 2.8052 min
Page 1 of 1
5/29/2019file:///C:/Users/sid_biddle/Stormshed/StormShed3G/Basin%202a.html
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
APPENDIX C
BIOSWALE CALCULATIONS
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
5/29/2019
JSB
RCJ
Step#
P-1 0.3508 cfs Water Quality Design Flow
P-2 0.01 ft/ft Swale Slope < 2%, underdrains required
P-3
D-1 0.25 ft
D-2 0.35
D-3 3 H:V
D-4a 7.62 ft
D-4b 9.12 ft
D-5 2.09 sf
90.6 = Length (Feet) Required
D-6 0.17 fps 90.9 = Length (Feet) w/ 9 min rest time
(this is still long enough)
D-7 Yes Okay - V<1.5 fps proceed to SC-1
D-8 D Table III-6.2 (D or E)
D-9 1.70 Table III - 6.6, n =nwq from step D-2
D-10 -ft
D-11 -
D-12 -%
D-13 -fps
D-14 -sf
D-15a -ft
D-15b -ft
D-16 If biofiltration swale is still to wide, see DOE page III-6-17 for more info and options
Step#
SC-1 0.77 cfs
BIOSWALE DESIGN
Date
Designer
Project Manager
WMT OGP Expansion #2516
RHA002516.20
On-Site (Redev)
Project Name
Project Number
Swale Title
Channel Width
T=b+2*y*z
Qwq (100-yr - 24-Hr)
Actual V
V=(VR/R)
Channel X-Sec Area
A=Q/A
New Swale Bottom Width (b)
b=(A/y)-Z*y
First Approx for VR
Hydraulic Radius
R=(V*R)/Vmax
Actual VR
VR=(1.486*(R1.6668)*S0.5)/n
% Difference
A=(b*y)+(Z*y2)
Flow Velocity
v=Q/A
Is Design Adequate
Degree of retardence
Design Steps (D)
Stability Check Steps (SC)
Design Flow Depth (y)
Mannings Roughness Coeff (ᶯwq)
Side Slope (Z)
Swale bottom width (b)
b=(Q*n)/(1.486*y1.667*s0.5)-(Z*y)
Top width (T)
T=b+2*y*z
Area (A)
Qwq (2-yr, 24-Hr)
Slope of Swale (s)
Select Vegetation to be used Grass Legume Mix
Preliminary Steps (P)
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25
SC-2a Good (Good or Fair)
SC-2b 0.25 ft
SC-3 D Table III-6.2 (D or E)
SC-4 3.00 fps Table III-6.3
SC-5 0.043 (Good initial choice 0.04)
SC-6 2.70 Table III - 6.6
SC-7 0.9 ft
SC-8 2.90
SC-9 7.38%%
SC-10 3.22 fps
SC-11 0.24 sf
SC-12 Yes Swale is Stable
1.2 ft
8.00 ft
15.2 ft
SC-13 1.2 ft 115
SC-14 2.2 ft
SC-15 1.16 ft
SC-16a 32.12 sf
SC-16b 15.06 cfs Okay, Capacity > 100-yr, 24-Hr Storm
R=((b*y*t)+(Z*y*t2))/(b+2yt*(Z2+1)0.5)
Channel X-Sec Area
Channel Capacity
Q=(1.486*A*R0.677*s0.5)/n
T=b+2*y*z
Depth of Flow
y=(t-b)/2z
Total Swale Depth
yt = y+1
Hydraulic Radius
A=Q/V
Compare A with Orig
New y =
New b =
b=(Q*n)/(1.486*y1.667*s0.5)-(Z*y)
New T =
Actual VR
VR=(1.486*R1.667*s0.5)/n
% difference
Actual V
V=VR/R
X-Sec Area
Degree of Retardance
Max allowed Velocity
Trial Mannings n
First Approx for VR
Hydraulic Radius
R=(V*R)/Vmax
Condition of vegetation
Height of grass @ first storm
DocuSign Envelope ID: 1C3D0486-3D78-416B-94DE-E64EA6106C25