Loading...
HomeMy WebLinkAboutS-393910(2) #5 MIN IN GROUTED CELLS, TYP. (1) #5 EACH SIDE OF OPENING, FULL HEIGHT, TYP. #5 VERT, TYP. i iKiTri ni nnii co aoo H a c 2. 0 �.40 �� A BOND BEAM � REINF. RIDGE VENT, PROVIDE END • g" CAPS PER MANUFACTURER'S #5 CORNER BARS AT ALL SPECIFICATIONS 30" BOND BEAM LOCATIONS DOOR 3" M I N � OPENING AT WALL CORNERS AND ► ago E METAL �, ( 6 GINTERSECTIONS GREATER THAN ROOFING 24 IN EITHER r11R�rTl(1�I TYPICAL CMU OPENING 385.10' TOP OF WALL 383.10' BOND BEAM INTERIOR FACE OF ALL CMU BLOCKS TO BE SMOOTH FACE 379.10' BOND BEAM #5 VERTICAL RST @ 24" O.C. MAX. LAP RST WITH STEM WALL DOWELS, FILL ALL REINFORCED CELLS WITH GROUT. DO NOT GROUT UNREINFORCED CELLS. BOND BEAM IV U I I U 3l./'1Lt DOUBLE 2x8 PRESSURE TREATED HEADER, CONTINUOUS WITH V8"O J-BOLTS AT 32" O.C. IN GROUTED VERTICAL CELLS, BOLT LENGTH AS NECESSARY FOR 6" EMBEDMENT. BOND BEAM, TOP COURSE 8"x8"x16" SPLIT -FACE CMU BLOCK, PROVIDE WEATHERPROOF AND ANTI -GRAFFITI COATING ON EXTERIOR. PROVIDE SMOOTH FACE BLOCKS WHERE LIGHTS AND EQUIPMENT ARE PROPOSED ON WALLS •r CMU WALL INSULATION. ALL WALL CMU BLOCK TO BE GROUTED SOLID AS SPECIFIED. BOND BEAM WITH #5 CONTINUOUS, LAP JOINTS 24" MINIMUM (TYPICAL) N #5 DOWELS AT 24" O.C., TYPICAL, TO MATCH LOCATIONS OF VERTICALLY REINFORCED CELLS OF CMU WALL ABOVE. �11"/X 11"/X D D D o• p p CONCRETE FLOOR ° CONCRETE STEM WALL CMU WALL 402 NOT TO SCALE S01 CMU WALL INTERSECTION CORNER rZ3 Sol 01 BOND BEAM STANDARD BLOCK LINTEL BLOCK (2) #5 EXTENDED 24" BEYOND OPENING IN GROUTED CELLS DOOR FRAME NOTE: DOOR FRAME OF SOUND RATED DOORS SHALL BE FULLY GROUTED. TYPICAL DOOR LINTEL 404 Sol ANCHOR TRUSS TO TOP PLATE PER PLAN FULL DEPTH VENTED EAVE BLOCKING FLASHING WITH DRIP EDGE 1"x6" COMPOSITE FASCIA W/ WOOD GRAIN PATTERN OVER NAILER EQUAL TO TREXTRIM PRESSURE TREATED WITH VENT 2 x4 NAILER 1 "x2" COMPOSITE TRIM W/ 1 "x4" CEDAR TRIM, WOOD GRAIN PATTERN CONTINUOUS, TYP, CONTINUOUS, TYP. ATTACH TRUSS TO SILL PLATE WITH SIMPSON HOLD DOWN ANCHOR PER PLAN ROOFING PLYWOOD ROOF DECK 1" AIR VENTILATION BAFFLE, INSTALL TO KEEP INSULATION AWAY FROM EAVE VENTS R-30 KRAFT PAPER FACED BATT INSULATION ON ALL CEILING SURFACES, INSTALL WITH KRAFT FACED SIDE OF INSULATION FACING INTERIOR OF BUILDING. FINISH CEILING WITH ONE LAYER OF %" GYPSUM WALLBOARD, FINISH SMOOTH AND PAINT WHITE. CONTINUOUS TRIM CMU WALL/TRUSS CONNECTIONS Sa, 2X FLAT J PLYWOOD J BLOCKING, TYP DECKING RIDGE VENT DETAIL K50"O 2 NOT TO SCALE S01 ROUNDED' nn�inn�T� Tnn 6" GALVANIZED STD STEEL PIPE. FILL WITH CONCRETE. PAINT SAFETY YELLOW. CAST -IN -PLACE CONCRETE BOLLARD FOUNDATION #4 HOOPS @ 12" O.C. (6) #4 VERTS EQUALLY SPACED BOLLARD DETAIL K601 E08 NOT TO SCALE U- c� 0 CV o � U Z o U O Lu J z w U- o Cn W Lu Lu J � z 0 U rn Of o w o CV 0 0: CV w cn Q Q > w uj 0 0 rn co CV ti U- U o W W Ea z W WLu co w I UL0 z� r~ o 0 V N Zo � DO C/) W W d CO Z Z W c�i W �, �_ =�o� � mN Lu cc ml 0 U w 0 of z SCALE: SHOWN 0 1 2 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: SO4 10 173�4_j