HomeMy WebLinkAboutS-393914PRESSURE GAUGE, SEE
SPECIFICA
)/2" STAINLESS STEEL DIAPHRAGM SEAL
)/2" STAINLESS STEEL 450 BEND. ORIENT
SUCH THAT GAUGE FACE IS VISIBLE
FROM ACCESS HATCH ABOVE.
STAINLESS STEEL THREADED TAF
PRESSURE GAUGE o,
NOT TO SCALE
_ NIPPLE
DF 3
:EL TEE
L BALL
PROPOSED
FORCE MAIN
NOTE:
* PIPE AND CONDUIT PENETRATIONS LESS THAN 4" SHALL BE GROUTED WATER TIGHT AT BOTH SIDES.
* PRECAST OR CORED PIPE PENETRATIONS SHALL BE SEALED PER THE DETAIL BELOW.
*GRAVITY SEWER CONNECTIONS SHALL USE KOR-N-SEAL BOOTS.
HOLE IN CONCRETE WALL OVERSIZED TO FIT
NPC WATERSTOP GROUTING RING AND PIPE
PER MANUFACTURER'S RECOMMENDATIONS
PROPOSED 4" AND
LARGER PIPE
PROVIDE NPC WATERSTOP GROUTING RING OR
APPROVED EQUAL. SEAL FLUSH TO WALL FACE EACH
SIDE WITH WATERTIGHT GROUT OR EQUIVALENT
PIPE PENETRATION ("B
NOT TO SCALE M01
/ SST SAFETY CHAIN WITH 4" SST CLEVIS
HOOK & SAFETY LATCH E,
)/8" SLEEVE,
WITH END CAP, WELDED
STIFFI
211
G.
1%" Q ALUMINUM PIPE, TYP.
1'-
2'-
2"QALUMIN
NOTES:
1. LOCATE SLEEVES TO NOT INTERFERE WITH HATCH CLOSING.
2. SAFETY CHAINS SHALL COVER 2 SIDES OF HATCH OPENINGS.
ACCESS HATCH FALL PROTECTION o,
NOTES:
1. LADDERS SHALL BE ALUMINUM INSIDE OF VALVE
VAULT. LADDERS SHALL BE FRP WITH STAINLESS STEEL
HARDWARE INSIDE OF WETWELL.
2. LADDERS MUST MEET CONSTRUCTION
REQUIREMENTS OF ANSI A14.3, OSHA 1910.27 &IBC 2015
CONCRETE WALL/RISER
I- - - 18
1" DIA. RUNGS, EQUALLY SPACED
VERTICALLY @ 12" O.C.
IN.
BAR
2/2 &2" BRACKETS T
ALUMINUM LADDER SAFETY POST, BILCO
LADDER -UP OR EQUAL, INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
STRINGERS, FB Z/2"V2" LADDE
PUNCH TO RECEIVE
� ACCESS HATCH LIMITS
.4
PLAN
VALVE VAULT ACCESS LADDER
NOT TO SCALE
TYF
C
S03
ILL
IBLY FOR
i
HATCH CLEAR
OPENING
AS REQUIRED
STANDON ADJUSTABLE
PIPE SUPPORT
2"0 GALVANIZED
STEEL PIPE
(2) 5/8"0 SS DRILL AND EPDXY
ANCHOR SYSTEM EQUAL TO HILTI
"HIT C100" WITH SS NUT AND
VALVE VAULT FLOOR
VERTICAL PIPE SUPPORT
NOT TO SCALE
)/3ENTIRE LENGTH
4.25" DIA. 1/8" MIN. THICKNESS
1/8" MIN. THICKNESS
E
M01
2" SQUARE
1" DIA SOLID METAL
STOCK, LENGTH AS
REQUIRED
)/8" SET SCREW
� �v
2.25"INSIDE MEASUREMENT
2.25" DEPTH
OPERATING NUT EXTENSION rF�
�MJ02
NOT TO SCALE
HATCH CURB
OPEI
co
coo1�,
�, a
4 00 :�4
LUO
co
Q., .
000 H a
o
12°
IAX. MAX. �j 7"
0 CONCRETE
ICHOR, TYP.
BILCO STAINLESS STEEL LADDER-1
EQUAL, INSTALL PER MANUFACTUI
RECOMMENDAT
�" LX2"WXX" F B ANGLE
Y2
"Ql CONCRETE ANCHOR
BOLT (TYP. OF 2)
CONTRACTOR DESIG
FRP LAD
PROFILE
WET WELL LADDER DETAIL
NOT TO SCALE
G
S03
UC-4
zCID
r~ o _o
V � N
zo
��
w� CZ
W d cWi)
z 9!
o
z
W N W c,
=�0�
� doN
W
cc
00
o � m
0
z
m
0
0
0
o
w
c
Z
0
U
OLu
J
w
—
Z
Cn
o
of
W
Lu
Lu
J
Z
0
o
w
o
CV06
ZO
0
Cfl
CV
pC
Q
Q
W
W
Of
0
0
Q
co
co
CV
Q
o
u_
0
w
W
Ea
<1
W �
SCALE. SHOWN
�1 2
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
DWG NO.: SHEET NO.:
M03 14V34i