Loading...
HomeMy WebLinkAboutMFP20003286.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20003286 IVR Number: 20003286 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:07/28/2020Application Date:3123059022Parcel Number: 4827 TALBOT RD S Permit Type:08/06/2020Issue Date:Franchise Permit Work Class:08/06/2021Expiration Date:Minor Utility Job Number: 107058838Franchise Type:Natural Gas Description: PSE gas Tap into existing 4" MPE IP with HHVT located 3ft(East) of centerline. Trenching approx 33ft across (West) Talbot Road South until reaching customer property line. Pothole all existing utilities. Restoration per City of Renton standards Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX INFRASOURCE SVCS B: (206) 949-5846Contractor Business License Number: 36742Construction Contractor: INFRASL871C2 SAPPHIRE HOMES INC 16805 SE 43RD CT BELLEVUE , WA 98006 Owner Marita Bond Puget Sound Energy - Billing 6905 S 228th St Kent, WA 98032 B: (253) 395-6346Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP20003286 Scott Warlick CED 8/6/2020 Monday - Friday 8:00AM - 3:00PM MFP20003286 TRACT A OPEN SPACE/ TREE RETENTION/ STORMWATER 13,109 S.F. BLDG 1 (2) UNITS ~ 2400 SQ.FT BLDG 2 (2) UNITS ~ 2400 SQ.FT BLDG 3 (3) UNITS ~ 2400 SQ.FT BLDG 4 (3) UNITS ~ 2400 SQ.FT BLDG 6 (3) UNITS ~ 2400 SQ.FT BLDG 7 (3) UNITS ~ 2400 SQ.FT BLDG 8 (2) UNITS ~ 2400 SQ.FT BLDG 5 (2) UNITS ~ 2400 SQ.FT TAX PARCEL 312305-9091 60'3MM3MM 2MM 2MM 3MM2MM 2MM 3MM 9'E15'S 69'S 133'S 137'S 26'E28'E29'E5/8" PE 1981-E4907 4" MPE IP 25'E109103106-20172" MPE IP 16'N 107021296-2004 JT4" MPE IP 3'E - 09098374-20168" STW HP 16'W - 8022548'E132'S 136'S 1903'N 20'N 19'N 5/8" MPE 1995-E 15'W5/8" PE 1981-E 4" MPE IP 3'E - 09098374-20168" STW HP 16'W - 80225449'S 48TH STTALBOT RD S(COLLECTOR ARTERIAL)53'S 48TH CT (PUBLIC) S 48TH ST 20' Owner / Developer Contact Info officeATTN: SAPPHIRE HOME, INC 16805 SE 43RD COURT BELLEVUE, WA 98006 ANDREW RUTTAN 206.390.8245 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) GENERAL NOTES - GAS (JOINT TRENCH): 1" = 50'105093048 107058838 Excavator to contact Utilities Underground Location Center (One-Call) 48 hours prior to construction, to two working days prior to construction. 1-800-424-5555 Notify appropriate permitting agency prior to job start (see permit requirements). Erosion and sediment control shall be per PSE Standard Practice 0150.3200 Techniques for Temporary Erosion and Sediment Control and any additional local jurisdiction requirements. Any change in route, pipe size/type, tie-in method or additional main footage must be approved by the appropriate Engineer/Project Manager. Complete "Exposed Pipe Condition Report" on all exposed existing Steel PSE Facilities. Check box on report for wire box (Test Lead) installation. Pipeline Markers and Warning Signs shall be installed and recorded by the Contractor per PSE Gas Operating Standard 2525.2500. To prevent accidental overpressure of adjoining systems, no two mains shall be connected, except as shown on this design, unless approved by the appropriate Engineer/Project Manager. System MAOP denoted by System MAOP = 60 PSIG Install Main Valves out of traffic where possible. Gauge (use Manometer for LP Systems) and monitor use of all stoppers and squeezes to insure adequate feed. Install one pound Anode for every 1000' of locating wire. Install Anode and Test Lead Wires per PSE Gas Operating Standards 2525.1200 and 2525.2300. If STW pipe involved, coordinate installation with CP Tech. ____________ Cell # ___________ . Purge Points and Pressure Taps shall be installed per PSE Gas Operating Standards 2525.3400 and PSE Gas Field Procedures Manual 0812 and 0813. Mains and services shall be tested and purged per PSE Gas Operating Standards 2525.3300 and 2525.3400. Unless otherwise noted: All pipes installed in plat to be 2" MPE-7. All crossings to be Yellow 4" PVC. All Services to be 1-1/8" PE. / denotes service stub location. (________') denotes footage between fittings. Customer to dig and backfill on private property or easement only. Trenches must conform to PSE Gas Operating Standards 2525.1500, 2525.1600 and 2525.1700. Note all recordable footages, locations and material changes on the as-built in red. Upon completion of the project send the print copy, along with the completed work order, listing crew & actual materials used to the appropriate design group. On site pre-con required before start of job. At symbol:install natural gas main piping and fixtures. Size as indicated on tables and work sketch (gas main is to parallel power system unless otherwise shown on work sketch). Inclement weather conditions may cause delays in construction times and dates. 19. 20. 18. 16. 17. 15. 14. 13. 6. 9. 11. 12. 10. 8. 7. 3. 5. 4. 2. 1. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE ELEC Order Number SAP Sup Order Nbr PC APPROVAL R. BLACKIE 253.395.6850 . E. PASAYE . 9.27.19 E. PASAYE . 9.27.19 REDT # (RW-115549 )CITY OF RENTON SAPPHIRE ON TALBOT 2" MPE-7 GAS MAIN EXTENSION - 8 M/F BLDGS, 20 UNITS 4827 TALBOT RD S, RENTON, WA 98056 PUGET SOUND ENERGY 107058838 105093048 1" = 50' 1 OF 2 KING 32 CIKNC 31SE-T23N-R05E 212.080 215.081 COMCAST BILL WALKER 253.288.7538 CENTURYLINK KENNETH LUU 206.346.0144 RIGHT OF WAY VAL CONNELL 425.462.3515 . . . N/A N/A N/A ... 21. Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 508210586 107058838 N/A 106359373 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS PROJECT PHASE Notification #Order # Retirement Relocate SAP Superior Service Stubs Service/Meter HP Svc/MSA Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter Service/Meter 4680 06/11 STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 INSTALL 2" MPE-7 33 FT JOINT 2" MPE-7 341 FT .. .. .. .. .. .. .. .. Cell Phone: Project Manager Contact Information: "Locates Required" "Flagging Required" Yes No Yes No E-Mail: Manager:RANDY BLACKIE 253.395.6850 randy.blackie@pse.com 60 IP 132-60 N/A N/A SITE PLAN xx INSTALL 2" = 33 FT JOINT 2" = 341 FT ... ... ... JOINT TRENCH DETAIL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter, install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller, install 6 inches compacted sand shading across the full width of the trench. * 2.Rocks greater than 10 inches diameter are not permitted in the final backfill. 3.Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5.If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. Primary & Secondary-Mainline Gas & Communications (NTS) Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 ANDREWRUTTAN@GMAIL.COM N Vicinity Map 47.4360, -122.2130 SITEProperty LineRoad Side Top View of Mainline Trench for Single Stubout Location Property LineRoad Side Top View of Mainline Trench for Pedestal or Double Stubout Location STUBOUT EXCAVATION DIMENSIONS NOT TO SCALE 2" CAP EOM/WIREBOX 29' SC/L & 268' WC/L ______' SC/L & _____' WC/L 2" INLINE TEE 96' WC/L & 28' SC/L ______' WC/L & _____' SC/L 4" x 2" HVTT TIE-IN 28' SC/L & 3' EC/L ______' SC/L & _____' EC/L JOINT 2" MPE-7 73' @ 96' WC/L (______)' @ _____'WC/L INSTALL 2" MPE-7 33' @ 28' SC/L (______)' @ _____' SC/L BEGIN JOINT MAIN 2" POLYVALVE/OPEN 30' WC/L & 28' SC/L ______' WC/L & _____' SC/L JOINT 2" MPE-7 68' @ 28' SC/L (______)' @ _____' SC/L 2" CAP EOM/WIREBOX 96' WC/L & 101' SC/L ______' WC/L & _____' SC/L JOINT 2" MPE-7 200' @ 28' SC/L & 29' S/CL (______)' @ _____' SC/L & _____' S/CL GAS SERVICE PIPE TABLE DESCRIPTION OF ACTIVITIES LOCATION PIPE DESIGN AS-BUILT FROM TO LOT SIZE (IN)TYPE LENGTH (FT)LOCATION LENGTH (FT) EFV SIZE LOCATION REMARKS LS SINGLE 2" MAIN BLDG 1 1 1/8 MPE-7 60 ( ')WCL 2600 SS SINGLE 2" MAIN BLDG 2 1 1/8 MPE-7 10 ( ')WCL 2600 SS SINGLE 2" MAIN BLDG 3 1 1/8 MPE-7 10 ( ')SCL 2600 LS SINGLE 2" MAIN BLDG 4 1 1/8 MPE-7 40 ( ')SCL 2600 SS SINGLE 2" MAIN BLDG 5 1 1/8 MPE-7 10 ( ')WCL 2600 SS SINGLE 2" MAIN BLDG 6 1 1/8 MPE-7 10 ( ')WCL 2600 LS SINGLE 2" MAIN BLDG 7 1 1/8 MPE-7 60 ( ')WCL 2600 LS SINGLE 2" MAIN BLDG 8 1 1/8 MPE-7 60 ( ')WCL 2600 SS SINGLES = 4 260 FT 1 1/8" PE PIPE LS SINGLES = 4 EX PLAT MAP 215.081 NOT TO SCALE SITE CROSSING CONDUIT TABLE X-ING # LOCATION GAS POWER XING LENGTH TYPE OF CROSSING (Feeder, Primary, Secondary, etc.)FROM TO SIZE (IN)TYPE QTY LOCATION SIZE (IN)TYPE QTY X01 bldg 2 bldg 5 4 40 1 N 3 SCH80 1 30 GAS MAIN, SECONDARY X02 bldg 5 bldg 8 2 40 1 E 3 SCH80 1 60 GAS SVC, SECONDARY X03 bldg 2 bldg 1 2 40 1 W GAS ONLY 50 GAS SVC X04 bldg 3 bldg 4 2 40 1 S GAS ONLY 30 GAS SVC X05 bldg 6 bldg 7 2 40 1 W GAS ONLY 60 GAS SVC 2" PVC PLUG /CAPS = 8 2" YELLOW SCH 40 PVC = 200 FT 4" PVC PLUG /CAPS = 2 4" YELLOW SCH 40 PVC = 30 FT 3" SCH80 GREY PVC = 90 FT 3" PVC PLUG /CAPS = 4 pothole all existing utilities restoration per city of renton standards MFP20003286 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE ELEC Order Number SAP Sup Order Nbr PC APPROVAL R. BLACKIE 253.395.6850 . E. PASAYE . 9.27.19 E. PASAYE . 9.27.19 REDT # (RW-115549 )CITY OF RENTON SAPPHIRE ON TALBOT 2" MPE-7 GAS MAIN EXTENSION - 8 M/F BLDGS, 20 UNITS 4827 TALBOT RD S, RENTON, WA 98056 PUGET SOUND ENERGY 107058838 105093048 AS SHOWN 2 OF 2 KING 32 CIKNC 31SE-T23N-R05E 212.080 215.081 COMCAST BILL WALKER 253.288.7538 CENTURYLINK KENNETH LUU 206.346.0144 RIGHT OF WAY VAL CONNELL 425.462.3515 . . . N/A N/A N/A ... ... ... ... Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) LOOKING NORTH G TALBOT ROAD SOUTH SECTION NOT TO SCALE 4" MPE IP 3'E - 09098374-2016 W E G 8" STW HP 16'W - 802254 LOOKING NORTH (PRIVATE ALLEY) TRACT C NOT TO SCALE LOOKING WEST SOUTH 48TH COURT (PUBLIC) NOT TO SCALE PROP. 2" MPE IP - 28' SC/L & 29' S/CLG PROP. 2" MPE IP - 28' SC/LG LOOKING WEST SOUTH 48TH COURT (PUBLIC) NOT TO SCALE PROP. 2" MPE IP - 96' WC/L G W E NS NS MFP20003286