Minor Franchise Permit: MFP20003286
IVR Number: 20003286
Permit Information
Permit Name: Puget Sound Energy Gas Permits
Address/Location:07/28/2020Application Date:3123059022Parcel Number: 4827 TALBOT RD S
Permit Type:08/06/2020Issue Date:Franchise
Permit Work Class:08/06/2021Expiration Date:Minor Utility
Job Number: 107058838Franchise Type:Natural Gas
Description: PSE gas Tap into existing 4" MPE IP with HHVT located 3ft(East) of centerline. Trenching approx 33ft across (West)
Talbot Road South until reaching customer property line. Pothole all existing utilities. Restoration per City of Renton
standards
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031ApplicantX
INFRASOURCE SVCS B: (206) 949-5846Contractor
Business License Number: 36742Construction Contractor: INFRASL871C2
SAPPHIRE HOMES INC 16805 SE 43RD CT
BELLEVUE , WA 98006
Owner
Marita Bond
Puget Sound Energy - Billing
6905 S 228th St
Kent, WA 98032
B: (253) 395-6346Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP20003286
Scott Warlick CED 8/6/2020
Monday - Friday 8:00AM - 3:00PM
MFP20003286
TRACT A
OPEN SPACE/
TREE RETENTION/
STORMWATER
13,109 S.F.
BLDG 1
(2) UNITS
~ 2400 SQ.FT
BLDG 2
(2) UNITS
~ 2400 SQ.FT
BLDG 3
(3) UNITS
~ 2400 SQ.FT
BLDG 4
(3) UNITS
~ 2400 SQ.FT
BLDG 6
(3) UNITS
~ 2400 SQ.FT
BLDG 7
(3) UNITS
~ 2400 SQ.FT
BLDG 8
(2) UNITS
~ 2400 SQ.FT
BLDG 5
(2) UNITS
~ 2400 SQ.FT
TAX PARCEL
312305-9091
60'3MM3MM
2MM
2MM
3MM2MM 2MM
3MM 9'E15'S
69'S
133'S
137'S
26'E28'E29'E5/8" PE
1981-E4907 4" MPE IP 25'E109103106-20172" MPE IP 16'N
107021296-2004 JT4" MPE IP 3'E - 09098374-20168" STW HP 16'W - 8022548'E132'S
136'S
1903'N
20'N
19'N
5/8" MPE
1995-E
15'W5/8" PE
1981-E 4" MPE IP 3'E - 09098374-20168" STW HP 16'W - 80225449'S 48TH STTALBOT RD S(COLLECTOR ARTERIAL)53'S 48TH CT
(PUBLIC)
S 48TH ST
20'
Owner / Developer Contact Info
officeATTN:
SAPPHIRE HOME, INC
16805 SE 43RD COURT
BELLEVUE, WA 98006
ANDREW RUTTAN 206.390.8245
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
GENERAL NOTES - GAS (JOINT TRENCH):
1" = 50'105093048 107058838
Excavator to contact Utilities Underground Location Center (One-Call) 48 hours prior to construction, to two
working days prior to construction. 1-800-424-5555
Notify appropriate permitting agency prior to job start (see permit requirements).
Erosion and sediment control shall be per PSE Standard Practice 0150.3200 Techniques for Temporary Erosion
and Sediment Control and any additional local jurisdiction requirements.
Any change in route, pipe size/type, tie-in method or additional main footage must be approved by the
appropriate Engineer/Project Manager.
Complete "Exposed Pipe Condition Report" on all exposed existing Steel PSE Facilities.
Check box on report for wire box (Test Lead) installation.
Pipeline Markers and Warning Signs shall be installed and recorded by the Contractor per PSE Gas Operating
Standard 2525.2500.
To prevent accidental overpressure of adjoining systems, no two mains shall be connected, except as shown on
this design, unless approved by the appropriate Engineer/Project Manager.
System MAOP denoted by System MAOP = 60 PSIG
Install Main Valves out of traffic where possible.
Gauge (use Manometer for LP Systems) and monitor use of all stoppers and squeezes to insure adequate feed.
Install one pound Anode for every 1000' of locating wire. Install Anode and Test Lead Wires per PSE Gas
Operating Standards 2525.1200 and 2525.2300.
If STW pipe involved, coordinate installation with CP Tech. ____________ Cell # ___________ .
Purge Points and Pressure Taps shall be installed per PSE Gas Operating Standards 2525.3400 and PSE Gas
Field Procedures Manual 0812 and 0813.
Mains and services shall be tested and purged per PSE Gas Operating Standards 2525.3300 and 2525.3400.
Unless otherwise noted:
All pipes installed in plat to be 2" MPE-7.
All crossings to be Yellow 4" PVC.
All Services to be 1-1/8" PE.
/ denotes service stub location.
(________') denotes footage between fittings.
Customer to dig and backfill on private property or easement only. Trenches must conform to PSE Gas
Operating Standards 2525.1500, 2525.1600 and 2525.1700.
Note all recordable footages, locations and material changes on the as-built in red.
Upon completion of the project send the print copy, along with the completed work order, listing crew & actual
materials used to the appropriate design group.
On site pre-con required before start of job.
At symbol:install natural gas main piping and fixtures. Size as indicated on tables and
work sketch (gas main is to parallel power system unless otherwise shown on work sketch).
Inclement weather conditions may cause delays in construction times and dates.
19.
20.
18.
16.
17.
15.
14.
13.
6.
9.
11.
12.
10.
8.
7.
3.
5.
4.
2.
1.
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
ELEC Order Number
SAP Sup Order Nbr
PC APPROVAL
R. BLACKIE 253.395.6850 .
E. PASAYE . 9.27.19
E. PASAYE . 9.27.19
REDT # (RW-115549 )CITY OF RENTON
SAPPHIRE ON TALBOT
2" MPE-7 GAS MAIN EXTENSION - 8 M/F BLDGS, 20 UNITS
4827 TALBOT RD S, RENTON, WA 98056
PUGET SOUND ENERGY
107058838
105093048
1" = 50' 1 OF 2
KING 32 CIKNC
31SE-T23N-R05E 212.080 215.081
COMCAST
BILL WALKER
253.288.7538
CENTURYLINK
KENNETH LUU
206.346.0144
RIGHT OF WAY
VAL CONNELL
425.462.3515
.
.
.
N/A N/A N/A
...
21.
Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: __________________Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
508210586 107058838
N/A 106359373
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
GAS
PROJECT PHASE Notification #Order #
Retirement
Relocate
SAP Superior
Service Stubs
Service/Meter
HP Svc/MSA
Dis. Reg. / FT
Ind. MSA
Ind. Service
Service/Meter
Service/Meter
4680 06/11
STOP TIME
START TIME
GAS MAIN PRESSURE & TESTING
TESTED BY
GAS MAIN INSTALLATION/RETIREMENT
SOAP AIR NITROGEN WATER
SOAP AIR NITROGEN WATER
STOP TIME
START TIME TESTED BY
TEST RESULTS P F
TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928
P F
Type/Work ManufacturerPipe Size Type Est Length Act Lgth
TYPE TEST
/ /
DATE OFF
PRESSURE
DATE ON
DATE OFF
TYPE TEST
PRESSURE
SYS MAOPDESIGN PRESS
DATE ON
2023 02/18
TEST RESULTS
/ /
/ /
/ /
Verify Testing Requirements, Chart vs Gauge
GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5
INSTALL 2" MPE-7 33 FT
JOINT 2" MPE-7 341 FT
.. ..
.. ..
.. ..
.. ..
Cell Phone:
Project Manager Contact Information:
"Locates Required"
"Flagging Required"
Yes No
Yes No
E-Mail:
Manager:RANDY BLACKIE
253.395.6850
randy.blackie@pse.com
60 IP 132-60
N/A N/A
SITE PLAN
xx
INSTALL 2" = 33 FT
JOINT 2" = 341 FT
...
...
...
JOINT TRENCH DETAIL
NOTES:
1. If the final backfill contains rocks greater than 8 inches in diameter, install 12 inches compacted sand shading across the full width of the trench. *
If the final backfill contains rocks 8 inches in diameter or smaller, install 6 inches compacted sand shading across the full width of the trench. *
2.Rocks greater than 10 inches diameter are not permitted in the final backfill.
3.Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the
side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line.
4. Utilities shall not be stacked over the gas line in the trench.
5.If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements.
6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies.
* Alternatives to full-width trench shading require PSE approval.
Primary & Secondary-Mainline Gas & Communications (NTS)
Primary
Dirt Pile
Final Grade
24" Min
36"
Min Cover
Over Power 48"
Max
Depth
Final Backfill
Gas
4" Sand Bedding
Property Line
intercept (depth varies).
SidewalkCurb
Location of roof drain
48" Typical
Width may vary per
Number of Utilities
and Conduits
6" or 12" Min Sand Shading
Over Gas after Compaction
12" Min
R/W or
Excavated
12" Typical
Power
Secondary
Power
TV & TEL
12" Min
12" Min
Separation
4,5
1,2
1
3
6
6" or 12" Min Sand Shading
Over Power after Compaction1
ANDREWRUTTAN@GMAIL.COM
N
Vicinity Map
47.4360, -122.2130
SITEProperty LineRoad Side
Top View of Mainline Trench for
Single Stubout Location Property LineRoad Side
Top View of Mainline Trench for Pedestal
or Double Stubout Location
STUBOUT EXCAVATION DIMENSIONS
NOT TO SCALE
2" CAP EOM/WIREBOX
29' SC/L & 268' WC/L
______' SC/L & _____' WC/L
2" INLINE TEE
96' WC/L & 28' SC/L
______' WC/L & _____' SC/L
4" x 2" HVTT TIE-IN
28' SC/L & 3' EC/L
______' SC/L & _____' EC/L
JOINT 2" MPE-7
73' @ 96' WC/L
(______)' @ _____'WC/L
INSTALL 2" MPE-7
33' @ 28' SC/L
(______)' @ _____' SC/L
BEGIN JOINT MAIN
2" POLYVALVE/OPEN
30' WC/L & 28' SC/L
______' WC/L & _____' SC/L
JOINT 2" MPE-7
68' @ 28' SC/L
(______)' @ _____' SC/L
2" CAP EOM/WIREBOX
96' WC/L & 101' SC/L
______' WC/L & _____' SC/L
JOINT 2" MPE-7
200' @ 28' SC/L & 29' S/CL
(______)' @ _____' SC/L & _____' S/CL
GAS SERVICE PIPE TABLE
DESCRIPTION
OF
ACTIVITIES
LOCATION PIPE DESIGN AS-BUILT
FROM TO LOT
SIZE
(IN)TYPE
LENGTH
(FT)LOCATION
LENGTH
(FT)
EFV
SIZE LOCATION REMARKS
LS SINGLE 2" MAIN BLDG 1 1 1/8 MPE-7 60 ( ')WCL 2600
SS SINGLE 2" MAIN BLDG 2 1 1/8 MPE-7 10 ( ')WCL 2600
SS SINGLE 2" MAIN BLDG 3 1 1/8 MPE-7 10 ( ')SCL 2600
LS SINGLE 2" MAIN BLDG 4 1 1/8 MPE-7 40 ( ')SCL 2600
SS SINGLE 2" MAIN BLDG 5 1 1/8 MPE-7 10 ( ')WCL 2600
SS SINGLE 2" MAIN BLDG 6 1 1/8 MPE-7 10 ( ')WCL 2600
LS SINGLE 2" MAIN BLDG 7 1 1/8 MPE-7 60 ( ')WCL 2600
LS SINGLE 2" MAIN BLDG 8 1 1/8 MPE-7 60 ( ')WCL 2600
SS SINGLES = 4 260 FT 1 1/8" PE PIPE
LS SINGLES = 4
EX PLAT MAP 215.081
NOT TO SCALE
SITE
CROSSING CONDUIT TABLE
X-ING
#
LOCATION GAS POWER
XING
LENGTH
TYPE OF CROSSING
(Feeder, Primary, Secondary, etc.)FROM TO
SIZE
(IN)TYPE QTY LOCATION
SIZE
(IN)TYPE QTY
X01 bldg 2 bldg 5 4 40 1 N 3 SCH80 1 30 GAS MAIN, SECONDARY
X02 bldg 5 bldg 8 2 40 1 E 3 SCH80 1 60 GAS SVC, SECONDARY
X03 bldg 2 bldg 1 2 40 1 W GAS ONLY 50 GAS SVC
X04 bldg 3 bldg 4 2 40 1 S GAS ONLY 30 GAS SVC
X05 bldg 6 bldg 7 2 40 1 W GAS ONLY 60 GAS SVC
2" PVC PLUG /CAPS = 8 2" YELLOW SCH 40 PVC = 200 FT
4" PVC PLUG /CAPS = 2 4" YELLOW SCH 40 PVC = 30 FT 3" SCH80 GREY PVC = 90 FT 3" PVC PLUG /CAPS = 4
pothole all existing utilities
restoration per city of renton
standards
MFP20003286
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC OP MAP
Emer Sect GAS WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
CP APPROVAL
MAPPING
SCALE PAGE
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY CONTACT PHONE NO DATE
ELEC Order Number
SAP Sup Order Nbr
PC APPROVAL
R. BLACKIE 253.395.6850 .
E. PASAYE . 9.27.19
E. PASAYE . 9.27.19
REDT # (RW-115549 )CITY OF RENTON
SAPPHIRE ON TALBOT
2" MPE-7 GAS MAIN EXTENSION - 8 M/F BLDGS, 20 UNITS
4827 TALBOT RD S, RENTON, WA 98056
PUGET SOUND ENERGY
107058838
105093048
AS SHOWN 2 OF 2
KING 32 CIKNC
31SE-T23N-R05E 212.080 215.081
COMCAST
BILL WALKER
253.288.7538
CENTURYLINK
KENNETH LUU
206.346.0144
RIGHT OF WAY
VAL CONNELL
425.462.3515
.
.
.
N/A N/A N/A
...
...
...
...
Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500
Reviewed and complied with all construction notes.
Recorded all required information on the as-built per GOS 2500.1700.
Completed post installation inspection per GOS 2525.1200 and 2525.2700.
Left the work area in a clean and safe condition.
FITTER'S CHECKLIST
Foreman's Name (printed) ___________________________________
Foreman's Signature________________________________________
Company: __________________ Date ______________
(CHECK BOX TO CONFIRM COMPLETION)
LOOKING NORTH
G
TALBOT ROAD SOUTH SECTION
NOT TO SCALE
4" MPE IP 3'E -
09098374-2016
W E
G 8" STW HP 16'W
- 802254
LOOKING NORTH
(PRIVATE ALLEY) TRACT C
NOT TO SCALE
LOOKING WEST
SOUTH 48TH COURT (PUBLIC)
NOT TO SCALE
PROP. 2" MPE IP - 28' SC/L & 29' S/CLG
PROP. 2" MPE IP - 28' SC/LG
LOOKING WEST
SOUTH 48TH COURT (PUBLIC)
NOT TO SCALE
PROP. 2" MPE IP - 96' WC/L G
W E
NS NS
MFP20003286