Loading...
HomeMy WebLinkAboutCedars CAD.zip RD_14-3SD16041 - DRS2000.zip RD_14-3SD16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:20 PM. Drawing: This is a transmittal based on RD_14-3SD16041.dwg. Files: Root Drawing: Engineering\RD_14-3SD16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3DEMO16041.dwg Base\RD_3LT16041.dwg Base\RD_3LAND16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Base\2tp_16041_C3D.dwg Fonts\dim.shx PlotCfgs\NDRS-MONO-H.ctb Base\2tp_14069.dwg Drawings\TM-BNDY.dwg Drawings\TM-BNDY-UPDATE.dwg Base\2cl_14069.dwg Base\3RD14069.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Base\2tp_13117.dwg DOTFONT.(shx,ttf) Base\3FE14069.dwg PlotCfgs\24x36 W3600.pc3 Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_14-3SD16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3DEMO16041.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_14-3SD16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_14-3SD16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:20 PM. Drawing: This is a transmittal based on RD_14-3SD16041.dwg. Files: Root Drawing: Engineering\RD_14-3SD16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3DEMO16041.dwg Base\RD_3LT16041.dwg Base\RD_3LAND16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Base\2tp_16041_C3D.dwg Fonts\dim.shx PlotCfgs\NDRS-MONO-H.ctb Base\2tp_14069.dwg Drawings\TM-BNDY.dwg Drawings\TM-BNDY-UPDATE.dwg Base\2cl_14069.dwg Base\3RD14069.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Base\2tp_13117.dwg DOTFONT.(shx,ttf) Base\3FE14069.dwg PlotCfgs\24x36 W3600.pc3 Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_14-3SD16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3DEMO16041.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_14-3SD16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_23-3SS16041 - DRS2000.zip RD_23-3SS16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:29 PM. Drawing: This is a transmittal based on RD_23-3SS16041.dwg. Files: Root Drawing: Engineering\RD_23-3SS16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx Base\2stk_16041_C3D.dwg PSE-preliminary\PRELIM 105092294 CEDARS AT THE HIGHLANDS .pdf PlotCfgs\NDRS-MONO-H.ctb Base\3TRE16041.dwg Base\3SS16041.dwg Base\3SD16041.dwg Base\3WA16041.dwg Base\3RD16041.dwg Engineering\10-3RAMP16041.dwg Base\3FG16041.dwg King County Water\03_04-3WAPR_16041.dwg Base\3LT16041.dwg Engineering\28-3COMPUT16041.dwg Mindy's Place\MINDY-1.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) PlotCfgs\TraffEx.ctb PlotCfgs\DMP-STANDARD-BLACK.ctb Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_23-3SS16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_23-3SS16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_23-3SS16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:29 PM. Drawing: This is a transmittal based on RD_23-3SS16041.dwg. Files: Root Drawing: Engineering\RD_23-3SS16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx Base\2stk_16041_C3D.dwg PSE-preliminary\PRELIM 105092294 CEDARS AT THE HIGHLANDS .pdf PlotCfgs\NDRS-MONO-H.ctb Base\3TRE16041.dwg Base\3SS16041.dwg Base\3SD16041.dwg Base\3WA16041.dwg Base\3RD16041.dwg Engineering\10-3RAMP16041.dwg Base\3FG16041.dwg King County Water\03_04-3WAPR_16041.dwg Base\3LT16041.dwg Engineering\28-3COMPUT16041.dwg Mindy's Place\MINDY-1.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) PlotCfgs\TraffEx.ctb PlotCfgs\DMP-STANDARD-BLACK.ctb Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_23-3SS16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_23-3SS16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_03-3HCP16041 - DRS2000.zip RD_03-3HCP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:13 PM. Drawing: This is a transmittal based on RD_03-3HCP16041.dwg. Files: Root Drawing: Engineering\RD_03-3HCP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\3RD16041.dwg Base\3HCH16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_03-3HCP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/3HCH16041.dwg Base/3RD16041.dwg Engineering/RD_03-3HCP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_03-3HCP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:13 PM. Drawing: This is a transmittal based on RD_03-3HCP16041.dwg. Files: Root Drawing: Engineering\RD_03-3HCP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\3RD16041.dwg Base\3HCH16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_03-3HCP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/3HCH16041.dwg Base/3RD16041.dwg Engineering/RD_03-3HCP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_02-3EXC16041 - DRS2000.zip RD_02-3EXC16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:13 PM. Drawing: This is a transmittal based on RD_02-3EXC16041.dwg. Files: Root Drawing: Engineering\RD_02-3EXC16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_02-3EXC16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Engineering/RD_02-3EXC16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_02-3EXC16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:13 PM. Drawing: This is a transmittal based on RD_02-3EXC16041.dwg. Files: Root Drawing: Engineering\RD_02-3EXC16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_02-3EXC16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Engineering/RD_02-3EXC16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_19-3VLT16041 - DRS2000.zip RD_19-3VLT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:27 PM. Drawing: This is a transmittal based on RD_19-3VLT16041.dwg. Files: Root Drawing: Engineering\RD_19-3VLT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\RD_3RD16041.dwg Base\RD_3SD16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\stone-two.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_19-3VLT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Engineering/RD_19-3VLT16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_19-3VLT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:27 PM. Drawing: This is a transmittal based on RD_19-3VLT16041.dwg. Files: Root Drawing: Engineering\RD_19-3VLT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\RD_3RD16041.dwg Base\RD_3SD16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\stone-two.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_19-3VLT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Engineering/RD_19-3VLT16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_01-3CVR16041 - DRS2000.zip RD_01-3CVR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:12 PM. Drawing: This is a transmittal based on RD_01-3CVR16041.dwg. Files: Root Drawing: Engineering\RD_01-3CVR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_01-3CVR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3RD16041.dwg Engineering/RD_01-3CVR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_01-3CVR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:12 PM. Drawing: This is a transmittal based on RD_01-3CVR16041.dwg. Files: Root Drawing: Engineering\RD_01-3CVR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_01-3CVR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3RD16041.dwg Engineering/RD_01-3CVR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_25-3SSPR16041 - DRS2000.zip RD_25-3SSPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:31 PM. Drawing: This is a transmittal based on RD_25-3SSPR16041.dwg. Files: Root Drawing: Engineering\RD_25-3SSPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_25-3SSPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_25-3SSPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_25-3SSPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:31 PM. Drawing: This is a transmittal based on RD_25-3SSPR16041.dwg. Files: Root Drawing: Engineering\RD_25-3SSPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_25-3SSPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_25-3SSPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_09-3RDFG16041 - DRS2000.zip RD_09-3RDFG16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:17 PM. Drawing: This is a transmittal based on RD_09-3RDFG16041.dwg. Files: Root Drawing: Engineering\RD_09-3RDFG16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg Base\RD_3PEDBRIDGE16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_09-3RDFG16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3PEDBRIDGE16041.dwg Base/RD_3RD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_09-3RDFG16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_09-3RDFG16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:17 PM. Drawing: This is a transmittal based on RD_09-3RDFG16041.dwg. Files: Root Drawing: Engineering\RD_09-3RDFG16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg Base\RD_3PEDBRIDGE16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_09-3RDFG16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3PEDBRIDGE16041.dwg Base/RD_3RD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_09-3RDFG16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_27-3CHAN16041 - DRS2000.zip RD_27-3CHAN16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:33 PM. Drawing: This is a transmittal based on RD_27-3CHAN16041.dwg. Files: Root Drawing: Engineering\RD_27-3CHAN16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg TIFF image References: Images\Crosswalk-STDH009.1.tif Images\PAVEMENTMARKING.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\109.pdf Engineering Details\COR_STD_PLAN_127.pdf Engineering Details\COR_STD_PLAN_128.pdf Images\MUTCD SIGN r7-1.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_27-3CHAN16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Engineering/RD_27-3CHAN16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/109.pdf Engineering Details/COR_STD_PLAN_127.pdf Engineering Details/COR_STD_PLAN_128.pdf Images/Crosswalk-STDH009.1.tif O , "6//4,6 üj O AYMQVOU O z Images/MUTCD SIGN r7-1.pdf Images/PAVEMENTMARKING.tif PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_27-3CHAN16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:33 PM. Drawing: This is a transmittal based on RD_27-3CHAN16041.dwg. Files: Root Drawing: Engineering\RD_27-3CHAN16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg TIFF image References: Images\Crosswalk-STDH009.1.tif Images\PAVEMENTMARKING.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\109.pdf Engineering Details\COR_STD_PLAN_127.pdf Engineering Details\COR_STD_PLAN_128.pdf Images\MUTCD SIGN r7-1.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_27-3CHAN16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Engineering/RD_27-3CHAN16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/109.pdf Engineering Details/COR_STD_PLAN_127.pdf Engineering Details/COR_STD_PLAN_128.pdf Images/Crosswalk-STDH009.1.tif O , "6//4,6 üj O AYMQVOU O z Images/MUTCD SIGN r7-1.pdf Images/PAVEMENTMARKING.tif PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_10-3RAMP16041 - DRS2000.zip RD_10-3RAMP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_10-3RAMP16041.dwg. Files: Root Drawing: Engineering\RD_10-3RAMP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3DEMO16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx Fonts\complex.shx Fonts\romant.shx Fonts\simplex_.ttf Fonts\stone-two.shx Base\2tp_16041_C3D.dwg Fonts\dim.shx PlotCfgs\NDRS-MONO-H.ctb Base\RD_3SD16041.dwg Base\2tp_14069.dwg Base\RD_3WA16041.dwg Base\RD_3SS16041.dwg Engineering\28-3COMPUT16041.dwg Base\RD_3LT16041.dwg Base\2stk_16041_C3D.dwg PSE-preliminary\PRELIM 105092294 CEDARS AT THE HIGHLANDS .pdf Drawings\TM-BNDY.dwg Drawings\TM-BNDY-UPDATE.dwg Base\2cl_14069.dwg Base\3RD14069.dwg Base\3TRE16041.dwg Base\3FG16041.dwg Base\3SS16041.dwg Base\3SD16041.dwg Base\3WA16041.dwg Base\3RD16041.dwg Engineering\10-3RAMP16041.dwg King County Water\03_04-3WAPR_16041.dwg Base\3LT16041.dwg Mindy's Place\MINDY-1.dwg The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) helv.(shx,ttf) symbol.(shx,ttf) Base\2tp_13117.dwg DOTFONT.(shx,ttf) archquik.(shx,ttf) PlotCfgs\TraffEx.ctb Base\3FE14069.dwg PlotCfgs\24x36 W3600.pc3 PlotCfgs\DMP-STANDARD-BLACK.ctb Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_10-3RAMP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3DEMO16041.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3RD16041.dwg Engineering/RD_10-3RAMP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_10-3RAMP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_10-3RAMP16041.dwg. Files: Root Drawing: Engineering\RD_10-3RAMP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3FG16041.dwg Base\RD_3DEMO16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx Fonts\complex.shx Fonts\romant.shx Fonts\simplex_.ttf Fonts\stone-two.shx Base\2tp_16041_C3D.dwg Fonts\dim.shx PlotCfgs\NDRS-MONO-H.ctb Base\RD_3SD16041.dwg Base\2tp_14069.dwg Base\RD_3WA16041.dwg Base\RD_3SS16041.dwg Engineering\28-3COMPUT16041.dwg Base\RD_3LT16041.dwg Base\2stk_16041_C3D.dwg PSE-preliminary\PRELIM 105092294 CEDARS AT THE HIGHLANDS .pdf Drawings\TM-BNDY.dwg Drawings\TM-BNDY-UPDATE.dwg Base\2cl_14069.dwg Base\3RD14069.dwg Base\3TRE16041.dwg Base\3FG16041.dwg Base\3SS16041.dwg Base\3SD16041.dwg Base\3WA16041.dwg Base\3RD16041.dwg Engineering\10-3RAMP16041.dwg King County Water\03_04-3WAPR_16041.dwg Base\3LT16041.dwg Mindy's Place\MINDY-1.dwg The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) helv.(shx,ttf) symbol.(shx,ttf) Base\2tp_13117.dwg DOTFONT.(shx,ttf) archquik.(shx,ttf) PlotCfgs\TraffEx.ctb Base\3FE14069.dwg PlotCfgs\24x36 W3600.pc3 PlotCfgs\DMP-STANDARD-BLACK.ctb Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_10-3RAMP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/RD_3DEMO16041.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3RD16041.dwg Engineering/RD_10-3RAMP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_06-3TESC16041 - DRS2000.zip RD_06-3TESC16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:15 PM. Drawing: This is a transmittal based on RD_06-3TESC16041.dwg. Files: Root Drawing: Engineering\RD_06-3TESC16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_06-3TESC16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_06-3TESC16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_06-3TESC16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:15 PM. Drawing: This is a transmittal based on RD_06-3TESC16041.dwg. Files: Root Drawing: Engineering\RD_06-3TESC16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_06-3TESC16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_06-3TESC16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_17-3SDPR16041 - DRS2000.zip RD_17-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:25 PM. Drawing: This is a transmittal based on RD_17-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_17-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_17-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_17-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_17-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:25 PM. Drawing: This is a transmittal based on RD_17-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_17-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_17-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_17-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_18-3SDPR16041 - DRS2000.zip RD_18-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:26 PM. Drawing: This is a transmittal based on RD_18-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_18-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_18-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_18-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_18-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:26 PM. Drawing: This is a transmittal based on RD_18-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_18-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_18-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_18-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_24-3SSPR16041 - DRS2000.zip RD_24-3SSPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:30 PM. Drawing: This is a transmittal based on RD_24-3SSPR16041.dwg. Files: Root Drawing: Engineering\RD_24-3SSPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_24-3SSPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_24-3SSPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_24-3SSPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:30 PM. Drawing: This is a transmittal based on RD_24-3SSPR16041.dwg. Files: Root Drawing: Engineering\RD_24-3SSPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3FG16041.dwg Base\RD_3SS16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_24-3SSPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_24-3SSPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_15-3SDPR16041 - DRS2000.zip RD_15-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:22 PM. Drawing: This is a transmittal based on RD_15-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_15-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_15-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_15-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_15-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:22 PM. Drawing: This is a transmittal based on RD_15-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_15-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_15-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_15-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_16-3SDPR16041 - DRS2000.zip RD_16-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:23 PM. Drawing: This is a transmittal based on RD_16-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_16-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANS.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx Fonts\complex.shx Fonts\romant.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_16-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_16-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_16-3SDPR16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:23 PM. Drawing: This is a transmittal based on RD_16-3SDPR16041.dwg. Files: Root Drawing: Engineering\RD_16-3SDPR16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3TRE16041.dwg Base\RD_3RD16041.dwg Base\RD_3HCH16041.dwg Base\RD_3WA16041.dwg Base\RD_3SD16041.dwg Base\RD_3SS16041.dwg Base\RD_3FG16041.dwg Base\RD_3LAND16041.dwg Base\RD_3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANS.shx Fonts\seguisb.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx Fonts\complex.shx Fonts\romant.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_16-3SDPR16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3HCH16041.dwg Base/RD_3LAND16041.dwg Base/RD_3LT16041.dwg Base/RD_3RD16041.dwg Base/RD_3SD16041.dwg Base/RD_3SS16041.dwg Base/RD_3TRE16041.dwg Base/RD_3WA16041.dwg Engineering/RD_16-3SDPR16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_22-3SFDET16041 - DRS2000.zip 2tp_16041_C3D.dwg 3FG16041.dwg 3SD16041.dwg RD_22-3SFDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:28 PM. Drawing: This is a transmittal based on RD_22-3SFDET16041.dwg. Files: Root Drawings: Engineering\RD_22-3SFDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg AutoCAD Drawing References: 3FG16041.dwg 3SD16041.dwg 2tp_16041_C3D.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\sanssb__.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_22-3SFDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Data Shortcut Source File R:\2016\0\16041\2\Drawings\Base\2tp_16041_C3D.dwg R:\2016\0\16041\3\Drawings\Base\3SD16041.dwg R:\2016\0\16041\3\Drawings\base\3FG16041.dwg Engineering/RD_22-3SFDET16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg 2tp_16041_C3D.dwg 3FG16041.dwg 3SD16041.dwg RD_22-3SFDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:28 PM. Drawing: This is a transmittal based on RD_22-3SFDET16041.dwg. Files: Root Drawings: Engineering\RD_22-3SFDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg AutoCAD Drawing References: 3FG16041.dwg 3SD16041.dwg 2tp_16041_C3D.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\sanssb__.ttf Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_22-3SFDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Data Shortcut Source File R:\2016\0\16041\2\Drawings\Base\2tp_16041_C3D.dwg R:\2016\0\16041\3\Drawings\Base\3SD16041.dwg R:\2016\0\16041\3\Drawings\base\3FG16041.dwg Engineering/RD_22-3SFDET16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_26-3SSDET16041 - DRS2000.zip RD_26-3SSDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:32 PM. Drawing: This is a transmittal based on RD_26-3SSDET16041.dwg. Files: Root Drawing: Engineering\RD_26-3SSDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\PipeBedding.tif Images\SideSewer.tif Images\SSCLEANOUT.tif Images\SSMANHOLE-STD401.tif Images\StandardManhole.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\402.2.pdf Images\SaddleManholeRev.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\arial.ttf Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_26-3SSDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_26-3SSDET16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/402.2.pdf Images/PipeBedding.tif W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL BEDDING FOR NOTES: SANITARY SEWER LIMITS OF PIPE ZONE OF PIPE 6" PIPE l. PROVIDE UNIFORM SUPPORT UNDER BARREL. HAND TAMP UNDER HAUNCHES. 2. 3, COMPACT BEDDING MATERIAL TO MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-0B OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. PUBLIC WORKS DEPARTMENT STD. PLAN - 405 PIPE BEDDING FOR SANITARY SEWERS APP OVED: Woro n DATE Images/SaddleManholeRev.pdf Images/SideSewer.tif —----SPOOL (LENGTH AS NEEDED) 6" SEWER STUBE SEWER MAIN TEE X 6" TEE (TYP,) COUPLING PROPERTY LINE i FUTURE 4" SIDE SEWER i i 6" CAP 4" STUD MARKING POST PAINTED WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND WIRE bRAPPED AROUND THE STUD AND EXTENDED TO TOP OF THE STUD. BEND AS REQUIRED SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), (SEE STD. PLAN 403.1 FOR INSTALLATION) JM EAGLE THREADED CLEAN-OUT ADAPTER HUB & PLUG (OR APPROVED EQUAL) EXISTING SANITARY SEWER MAIN ——2.0% MIN. SLOPE 6' SEWER sn.JB SEWER MAIN SIZE X 6" TEE FUTURE 4" FUTURE 6' 'x 4" SIDE SEWER REDUCER A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG-BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG-BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC & ceoo PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE-DRILLED A ROMAC SADDLE (OR APPROVED EQUAL). D, DUCTILE IRON MAIN - CORE-DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK-OUTS OR THE STRUCTURE SHALL BE CORE-DRILLED. 3000 PSI MIX CONCRETE BLOCKING ML SLQPE 6" TEE SEWER MAIN CONCRETE BLOCKING ANGLE HORIZONTAL SEWER MAIN ?flCAL SEVER NOTE: UNLESS OTHERWISE SHOM* ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, MAICHEVER IS LOWER. PUBLIC WORKS DEPARTMENT STANDARD SIDE SEWER INSTALLATION (SEWER MAIN TO PROPERTY LINE) App VED: G uzm PubRe STD, PLAN - 406.1 i IIWIWA 0 OAT Images/SSCLEANOUT.tif RECESSED LIFT POCKET 3/4" LETTERING "SEWER" (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1.5 STAINLESS STEEL REF. PART #00981177 Not to Scale FRAME 2'-o" 2'-o" DIAMETER SEWER 12-3/40-—4 11" "B" -L -1 5/8" a" 8" CLASS ASPHALT BOLT DETAIL CAST IRON RING AND COVER c.Y 45' (1/8) BEND 45' (1/8) BEND SAND OR EXPANDABLE FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER 1. 8" AND 6" CLEAN-OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT 2. IN UNIMPROVED AREAS. POUR A 11-0" THICK, 2'-O" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. PUBLIC WORKS DEPARTMENT 8" OR 6" CLEANOUT APPROVED: FOR SANITARY SEWER MAIN Grean eubEcWg ASSEMBLY, STD. PLAN n - 403.1 D Images/SSMANHOLE-STD401.tif BOLTHOLES - 3 PLCS EQUALLY SPACED APART ON 23 1/16' (586mm) DIA B.C. (SEE DETAIL) RENTON o SEVER UDE IN COVER & FRAME PLAN VIEW 25' DIA. 8 3/4 • [222mm] TYP COVER SECTION VIEW 26 1/2* DIA C673mm] 25 1/4' DIA 1/4' (6mm) DIA NEOPRENE GASKET 23 [16mm] C64mm] NOTES: O COVER BOTTOM VIEW (3) BLT SOC (ALLEN HEAD) 5/84-11 x 1.5 ss RUBBER WASHER EON BOLTING DETAIL 1/4' ce7mm] GASKET GROOVE DETAIL 3/8' DIA CL OPEN C594mm] 27 5/16' DIA 34 1/8' DIA FRAME SECTION VIEW l. ALL COVERS SHALL BE LOCKINC LID PER EAST JORDAN IRON WORKS INC. No. 3717Cl OR EQUAL. 2. PUBLIC WORKS DEPARTMENT MANHOLE FRAME AND COVER USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). STD. PLAN - 401 DECEMBER 2008 Images/StandardManhole.tif 12" MAX MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 POLYPROPYLENE STEPS STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER-POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE CONCRETE SHELF E' NOT TO SCALE 48" MH 54" MH 60" MH 54" 60" CD' 24" MIN. 8" MIN. 5.5" MIN. 24" MIN. 6" MIN. 42" MIN. PRECAST BASE SECTION OR CAST IN SHELF. 24" 30" NOTES: l. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. STEPS TO BE POLYPROPYLENE SAFETY STEPS. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. CASTING SHALL BE PER STD. PLAN 401. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. CONNECTIONS -ro MANHOLE SHALL BE MADE USING CPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. PUBLIC WORKS DEPARTMENT STANDARD SANITARY MANHOLE STD. PLAN - 400.1 SEPTEMBER 2011 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_26-3SSDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:32 PM. Drawing: This is a transmittal based on RD_26-3SSDET16041.dwg. Files: Root Drawing: Engineering\RD_26-3SSDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\PipeBedding.tif Images\SideSewer.tif Images\SSCLEANOUT.tif Images\SSMANHOLE-STD401.tif Images\StandardManhole.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\402.2.pdf Images\SaddleManholeRev.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\arial.ttf Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_26-3SSDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_26-3SSDET16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/402.2.pdf Images/PipeBedding.tif W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL BEDDING FOR NOTES: SANITARY SEWER LIMITS OF PIPE ZONE OF PIPE 6" PIPE l. PROVIDE UNIFORM SUPPORT UNDER BARREL. HAND TAMP UNDER HAUNCHES. 2. 3, COMPACT BEDDING MATERIAL TO MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-0B OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. PUBLIC WORKS DEPARTMENT STD. PLAN - 405 PIPE BEDDING FOR SANITARY SEWERS APP OVED: Woro n DATE Images/SaddleManholeRev.pdf Images/SideSewer.tif —----SPOOL (LENGTH AS NEEDED) 6" SEWER STUBE SEWER MAIN TEE X 6" TEE (TYP,) COUPLING PROPERTY LINE i FUTURE 4" SIDE SEWER i i 6" CAP 4" STUD MARKING POST PAINTED WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND WIRE bRAPPED AROUND THE STUD AND EXTENDED TO TOP OF THE STUD. BEND AS REQUIRED SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), (SEE STD. PLAN 403.1 FOR INSTALLATION) JM EAGLE THREADED CLEAN-OUT ADAPTER HUB & PLUG (OR APPROVED EQUAL) EXISTING SANITARY SEWER MAIN ——2.0% MIN. SLOPE 6' SEWER sn.JB SEWER MAIN SIZE X 6" TEE FUTURE 4" FUTURE 6' 'x 4" SIDE SEWER REDUCER A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG-BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG-BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC & ceoo PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE-DRILLED A ROMAC SADDLE (OR APPROVED EQUAL). D, DUCTILE IRON MAIN - CORE-DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK-OUTS OR THE STRUCTURE SHALL BE CORE-DRILLED. 3000 PSI MIX CONCRETE BLOCKING ML SLQPE 6" TEE SEWER MAIN CONCRETE BLOCKING ANGLE HORIZONTAL SEWER MAIN ?flCAL SEVER NOTE: UNLESS OTHERWISE SHOM* ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, MAICHEVER IS LOWER. PUBLIC WORKS DEPARTMENT STANDARD SIDE SEWER INSTALLATION (SEWER MAIN TO PROPERTY LINE) App VED: G uzm PubRe STD, PLAN - 406.1 i IIWIWA 0 OAT Images/SSCLEANOUT.tif RECESSED LIFT POCKET 3/4" LETTERING "SEWER" (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1.5 STAINLESS STEEL REF. PART #00981177 Not to Scale FRAME 2'-o" 2'-o" DIAMETER SEWER 12-3/40-—4 11" "B" -L -1 5/8" a" 8" CLASS ASPHALT BOLT DETAIL CAST IRON RING AND COVER c.Y 45' (1/8) BEND 45' (1/8) BEND SAND OR EXPANDABLE FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER 1. 8" AND 6" CLEAN-OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT 2. IN UNIMPROVED AREAS. POUR A 11-0" THICK, 2'-O" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. PUBLIC WORKS DEPARTMENT 8" OR 6" CLEANOUT APPROVED: FOR SANITARY SEWER MAIN Grean eubEcWg ASSEMBLY, STD. PLAN n - 403.1 D Images/SSMANHOLE-STD401.tif BOLTHOLES - 3 PLCS EQUALLY SPACED APART ON 23 1/16' (586mm) DIA B.C. (SEE DETAIL) RENTON o SEVER UDE IN COVER & FRAME PLAN VIEW 25' DIA. 8 3/4 • [222mm] TYP COVER SECTION VIEW 26 1/2* DIA C673mm] 25 1/4' DIA 1/4' (6mm) DIA NEOPRENE GASKET 23 [16mm] C64mm] NOTES: O COVER BOTTOM VIEW (3) BLT SOC (ALLEN HEAD) 5/84-11 x 1.5 ss RUBBER WASHER EON BOLTING DETAIL 1/4' ce7mm] GASKET GROOVE DETAIL 3/8' DIA CL OPEN C594mm] 27 5/16' DIA 34 1/8' DIA FRAME SECTION VIEW l. ALL COVERS SHALL BE LOCKINC LID PER EAST JORDAN IRON WORKS INC. No. 3717Cl OR EQUAL. 2. PUBLIC WORKS DEPARTMENT MANHOLE FRAME AND COVER USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). STD. PLAN - 401 DECEMBER 2008 Images/StandardManhole.tif 12" MAX MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 POLYPROPYLENE STEPS STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER-POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE CONCRETE SHELF E' NOT TO SCALE 48" MH 54" MH 60" MH 54" 60" CD' 24" MIN. 8" MIN. 5.5" MIN. 24" MIN. 6" MIN. 42" MIN. PRECAST BASE SECTION OR CAST IN SHELF. 24" 30" NOTES: l. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. STEPS TO BE POLYPROPYLENE SAFETY STEPS. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. CASTING SHALL BE PER STD. PLAN 401. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. CONNECTIONS -ro MANHOLE SHALL BE MADE USING CPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. PUBLIC WORKS DEPARTMENT STANDARD SANITARY MANHOLE STD. PLAN - 400.1 SEPTEMBER 2011 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_28-3COMPUT16041 - DRS2000.zip RD_28-3COMPUT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:34 PM. Drawing: This is a transmittal based on RD_28-3COMPUT16041.dwg. Files: Root Drawing: Engineering\RD_28-3COMPUT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\3RD16041.dwg Base\3HCH16041.dwg Base\3SD16041.dwg Base\3SS16041.dwg Base\3WA16041.dwg Base\3LAND16041.dwg Base\3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx Base\3TRE16041.dwg PlotCfgs\NDRS-MONO-H.ctb Base\3FG16041.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_28-3COMPUT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/3HCH16041.dwg Base/3LAND16041.dwg Base/3LT16041.dwg Base/3RD16041.dwg Base/3SD16041.dwg Base/3SS16041.dwg Base/3WA16041.dwg Engineering/RD_28-3COMPUT16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_28-3COMPUT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:34 PM. Drawing: This is a transmittal based on RD_28-3COMPUT16041.dwg. Files: Root Drawing: Engineering\RD_28-3COMPUT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\2tp_16041_C3D.dwg Base\3RD16041.dwg Base\3HCH16041.dwg Base\3SD16041.dwg Base\3SS16041.dwg Base\3WA16041.dwg Base\3LAND16041.dwg Base\3LT16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx Base\3TRE16041.dwg PlotCfgs\NDRS-MONO-H.ctb Base\3FG16041.dwg The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_28-3COMPUT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/3HCH16041.dwg Base/3LAND16041.dwg Base/3LT16041.dwg Base/3RD16041.dwg Base/3SD16041.dwg Base/3SS16041.dwg Base/3WA16041.dwg Engineering/RD_28-3COMPUT16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_04_05-3TRE16041 - DRS2000.zip RD_04_05-3TRE16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:14 PM. Drawing: This is a transmittal based on RD_04_05-3TRE16041.dwg. Files: Root Drawing: Engineering\RD_04_05-3TRE16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3FG16041.dwg Base\RD_3TRE16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_04_05-3TRE16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3RD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_04_05-3TRE16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_04_05-3TRE16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:14 PM. Drawing: This is a transmittal based on RD_04_05-3TRE16041.dwg. Files: Root Drawing: Engineering\RD_04_05-3TRE16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg Base\2cl_16041.dwg Base\RD_3RD16041.dwg Base\2tp_16041_C3D.dwg Base\RD_3FG16041.dwg Base\RD_3TRE16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\complex.shx Fonts\simplex_.ttf Fonts\stone-two.shx Fonts\dim.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg helv.(shx,ttf) symbol.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_04_05-3TRE16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Base/2cl_16041.dwg Base/2tp_16041_C3D.dwg Base/RD_3FG16041.dwg Base/RD_3RD16041.dwg Base/RD_3TRE16041.dwg Engineering/RD_04_05-3TRE16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_13-3RDDETP16041 - DRS2000.zip RD_13-3RDDETP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_13-3RDDETP16041.dwg. Files: Root Drawing: Engineering\RD_13-3RDDETP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_13-3RDDETP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_13-3RDDETP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_13-3RDDETP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_13-3RDDETP16041.dwg. Files: Root Drawing: Engineering\RD_13-3RDDETP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_13-3RDDETP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_13-3RDDETP16041.dwg Engineering/RD_E22X34_16041.dwg PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_20_21-3SDDET16041 - DRS2000.zip RD_20_21-3SDDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:27 PM. Drawing: This is a transmittal based on RD_20_21-3SDDET16041.dwg. Files: Root Drawing: Engineering\RD_20_21-3SDDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\Bi-Directional Vaned Grate.tif Images\CB1.tif Images\CB2.tif Images\CBINSTALLATION.tif Images\Fixed Bollard H022.tif Images\OpenFace.tif Images\RemovableBollard-STDH021.tif Images\ROUNDSDCOVER.tif Images\Type 1L CB.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Images\106.pdf Engineering Details\200.00.pdf Engineering Details\200.10.pdf Engineering Details\201.00.pdf Engineering Details\202.00.pdf Engineering Details\203.00.pdf Engineering Details\204.30.pdf Engineering Details\204.50.pdf Engineering Details\400.4.pdf Images\Removale Bolard H021.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_20_21-3SDDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_20_21-3SDDET16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/200.00.pdf Engineering Details/200.10.pdf Engineering Details/201.00.pdf Engineering Details/202.00.pdf Engineering Details/203.00.pdf Engineering Details/204.30.pdf Engineering Details/204.50.pdf Engineering Details/400.4.pdf Images/106.pdf Images/Bi-Directional Vaned Grate.tif z z z o OUTFALL TD STREAM TOP 4 EQUAL SPACES SECTION DUMP NO POLLUTANTS 4 EQUAL SPACES SLOT - SEE DETAIL AND NOTE 1 NOTES SECTION 3/4" BOLT-DOWN SLOT DETAIL SEE NOTE 1 ISOMETRIC Provide two slots in the grate that are vertically aligned 1. with the holes in the frame. Location of bolt-down slots varies among different manufacturers. 2. Refer to Standard Specification 9-05.15(2) for additional requirements. 3. Use only on sags and vertical curbs locations. 4. Unless otherwise specified, vaned grates shall be used with standard frame in the travel way, gutter or shoulder. vaned grates shall not be located within crossroads. Use vaned grates along rolled curbs. PUBLIC WORKS DEPARTMENT RECTANGULAR BI-DIRECTIONAL VANED GRATE STD. PLAN - 204.30 MARCH 2008 Images/CB1.tif PIPE ALLOWANCES z FRAME AND VANED GRATE PIPE MATERIAL REINFORCED OR PLAIN CONCRETE ALL METAL PIPE CPSSP * (STD. SPEC. 9-05.20) SOLID WALL PVC MAXIMUM INSIDE DIAMETER 12" 150 6" OR 121 ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12' HEIGHT RECTANGULAR ADJUSTMENT SECTION (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE Or 6) NOTES #3 BAR EACH CORNER #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN. #3 BAR HOOP SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION 1. 2. 3. 4. 5. 6. 7. 8. As acceptable alternatives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. The frame and grate must be installed with the flange down. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. The opening shall be measured at the top of the precast base section. All pickup holes shall be grouted full after the basin has been placed. All grade rings and castings shall be set in mortar in accordance with Standard Specification 9-04.3. PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE Pl STD, PLAN - 200,00 MARCH 2008 Images/CB2.tif o o o z o z z z O MORTAR FILLET 48", 54B, 60B, 72", 84N OR 96" STEPS OR LADDER CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP MORTAR (TYP.) REINFORCING STEEL (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING SEPARATE BASE CAST-IN-PLACE non RING 4 SEPARATE BASE PRECAST NOTES INTEGRAL BASE PRECAST WITH RISER GRAVEL BACKFILL FOR PIPE ZONE BEDDING CATCH BASIN DIMENSIONS CATCH WALL BASE BASIN THICKNESS THICKNESS MAXIMUM KNOCKOUT SIZE 42" 48" 72" DISTANCE BETWEEN KNOCKOUTS 8" 8" BASE REINFORCING STEEL in2/ft. IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE DIAMETER 48" 54" 72" 4" 4.5" 8" 8" 8" 8" 0.23 0.19 0.25 0.35 0.39 0.39 0.15 0.19 0.25 0.24 0.29 0.29 PIPE ALLOWANCES 1. 2. 3. 4. 5. No steps are required when height is 4' or less. The bottom of the precast catch basin may be sloped to facilitate cleaning. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. All grade rings, risers, and castings shall be set in mortar in accordance with Standard Specification 9-04.3. CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER SOLID PROFILE BASIN ALL CPSSP WALL WALL CONCRETE DIAMETER 48" 54" 72" 84" 42" METAL 54" 24" 42" 54" O PVC@ 0 27" 48" 48" 48" O Corrugated Polyethylene Storm Sewer Pipe (Std. @ (Std. spec. 9-05.12(1)) O (Std. spec. 9-05.12(2)) spec. 9-05.20) 201.00 PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE 2 STD. - MARCH 2008 Images/CBINSTALLATION.tif z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mages/Fixed Bollard H022.tif TYPE PRESSURE 7-1 0' x 4" TREATED 7—1 CEDAR HORIZ. TOP TYPE ROST & BOTTOM & VERTICAL (PER SIDE) CHAMFER CRUSHED SURFACING) -F CRUSHED NOTE: SURFACINC o MINIMUM CLEARANCE BETWEEN REBAR CONCRETE SURFACE. DATE a APPR'D 0 450 CHAMFER ALL AROUND TOP p AINT TOP 5" WHITE ALL AROUND REFLECTIVE MARKER (TYPICAL BOTH SIDES) l" DEEP NOTCH ALL AROUND 5" 1 0 450 CHAMFER ALL EDGES SLOPE CONCRETE FOR. DRAINAGE 2 'x3 8" JOINT MATERIAL *CONCRETE SIDEWALK 16" 18" 10' FIXED WOODEN BOLLARD ADOPTED CITY OF RENTON STANDARD PLANS LST DATE: 04/04 REVISION BY DWC. NAME: HO 22 PACE: Images/OpenFace.tif LEVEL HOOD 1/2" MIN z SEE NOTE 3 29" MIN. 20 1/4" SEE NOTE 4 (TYP.) SEE NOTE 2 (TYP.) TOP VIEW FRAME DETAIL CURB OR CURB AND GUTTER MATCH TOP OF HOOD TO TOP OF CURB (TYP.) HOOD 6 OPENING HEIGHT TOP OF GRATE FRAME DETAIL SECTION CATCH BASIN GRATE = 34" (WIDE SIDE) CATCH BASIN TYPE 1 = 40" (WIDE SIDE) CATCH BASIN TYPE IL SEE NOTE 1 SECTION NOTES DO NOT INSTALL SAFETY BAR/ DEBRIS GUARD 20" x 24" VANED GRATE FRAME 1. 2. 3. 4. 5. 6. The asymmetry of the Combination Inlet shall be considered when calculating the offset distance for the catch basin. See SECTION A. The dimensions of the Frame and Hood may vary slightly among dif- ferent manufacturers. The Frame may have cast features intended to support a grate guard. Hood units shall mount outside of the Frame. The methods for fastening the Safety Bar / Debris Guard Rod to the Hood may vary. The Hood may include casting lugs. The top of the Hood may be cast with a pattern. Attach the Hood to the frame with two 3/4" x 2" hex head bolts, nuts, and oversize washers. The washers shall have diameters adequate to assure full bearing across the slots. When bolt-down grates are specified in the contract, provide two holes in the frame that are vertically aligned with the grate slots. Tap each hole to accept a 5/8" x - 11 NC x 2' allen head cap screw. Location of bolt-down holes varies among different manufacturers. See BOLT- DOWN DETAIL Only ductile iron Vaned Grates shall be used. This plan is intended to show the installation details of a manufac- tured product. It is not the intent of this plan to show the specific details necessary to fabricate the castings shown on this drawing. ISOMETRIC VIEW PUBLIC WORKS DEPARTMENT STD, PLAN - 203,00 OPEN CURB FACE FRAME AND GRATE INSTALLATION DETAIL MARCH 2008 Images/RemovableBollard-STDH021.tif TYPE PRESSURE TREATED CEDAR POST 0 45' CHAMFER. ALL EDGES HORIZ. TOP & BOTTOM & VERTICAL (PER SIDE) TYPE @ 45' CHAMFER ALL AROUND TOP PAINT TOP 5" WHITE ALL AROUND REFLECTIVE MARKER (TYPICAL BOTH SIDES) 1" DEEP NOTCH ALL AROUND GALVANIZED STEEL HASP FOR LOCK 2"x6" STEEL HIACE WELDED TO 9-1 4"xg-1 4" DOOR WITH 4" RADIUS ON CPEN CORNERS ND PLATE SPACER. 1 4" GALVANILED STEEL PLATE SPACER STEEL 4" CHAMFER _I_fi4L NO 5" JO" "12 18 12' APPR'D 2 ANCHOR BOLT, WELDED TO SPACER 2"x3 8" JOINT MATERIAL CONCRETE SIDEWALK ASPHALT CRUSHED SURFACINC CRUSHED SURFACING 8 WEEN MINIMUM CONCRE DATE CLEARANCE E SURFACE, REVISION 4" BY REMOVABLE WOODEN ADOPTED CITY OF RENTON STANDARD PLANS BOLLARD DWC. NAME: LST DATE: 04 04 HODI RACE. • HODI Images/Removale Bolard H021.pdf Images/ROUNDSDCOVER.tif O RENTON AHEAD OF THECURVE DRAIN o PLAN 25" DIA. [635mm] 1/2" [13mm] LETTERING BOLTHOLES - 3 PLCS EQUALLY SPACED 1200 APART ON 23 1/16" (586mm) DIA B.C. (1) 1" (25mm) DIA PICKHOLE 1 1/4" [32mm] LETTERING [16mml [19mm] [222mm] TYP COVER SECTION VIEW 26 1/2" DIA [673mm] 25 1/4" DIA [641 mm] 1/4" (6mm) DIA NEOPRENE GASKET 23 3/8" DIA CL OPEN [594mm] 27 5/16" DIA [694mm] 34 1/8" DIA [867mm] FRAME SECTION VIEW [25mrn] [64mm] [27mm] 6" [152mm] NOTES 08LUEOO cu COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 ss RUBBER WASHER EON BOLTING DETAIL [6mm] [27mm] [3mm] [R3mm] GASKET GROOVE DETAIL ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. PUBLIC WORKS DEPARTMENT STORM ROUND FRAME AND COVER STD. PLAN - 204.50 MARCH 2008 Images/Type 1L CB.tif PIPE ALLOWANCES FUME AND VANED CUTE 6' OR 12' ONE BAR HOOP FOR 6' HEIGHT TWO BAR HOOPS FOR 1? HEIGI-T RECTANGULAR ADJUSTMENT SECTION TWO BAR REDUCING SECTION BAR EACH CORNER BAR EACH SIDE BAR EACH WAY PRECAST BASE SECTION PIPE MATERIAL REINFORCED OR PLAIN CONCRETE ALL METAL PIPE CPSSP * (STD. SPEC. 905.20) SOLID WALL MAXIMUM INSIDE DIAMETER (STD. SPEC. 9-4h12(1)) PROFILE WALL PVC (STD. SPEC. * CORRU@ATED POLYETHYLENE STORM SEWER PIPE NOTES 1. 2. 3. 4. 5. 6. 7. 8. As acæptable attemaives the rebar showm in the PRECAST BASE SECTION, fibers (placed to the Standard Specifiætions), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum requited rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. The knockout diameter shall not be greater than 26". shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the ouEide of the pipe. Ater the pipe is fill the gap with joint mortar in with Standard Spedficatbn 9-04.3. The maximum deph from the finished grade to he lowest pipe invert shall be 5. The frame and grü must be installed with the hange down. The Precast Base Section may have a rounded noor, and the walls may be sbped at a rate of 1 :24 or steeper. The opening shall be measured at the bp of the precast base sectbn. All pickup holes shall be full after the basin has been plaæd. All grade rings and castings shall be set in mortar in accordance with Sbndard Specificatbn 9-04.3. BAR EACH CORNER #3 BAR 18' MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE 11.. STD. PLAN - 200.10 MARCH 2008 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_20_21-3SDDET16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:27 PM. Drawing: This is a transmittal based on RD_20_21-3SDDET16041.dwg. Files: Root Drawing: Engineering\RD_20_21-3SDDET16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\Bi-Directional Vaned Grate.tif Images\CB1.tif Images\CB2.tif Images\CBINSTALLATION.tif Images\Fixed Bollard H022.tif Images\OpenFace.tif Images\RemovableBollard-STDH021.tif Images\ROUNDSDCOVER.tif Images\Type 1L CB.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Images\106.pdf Engineering Details\200.00.pdf Engineering Details\200.10.pdf Engineering Details\201.00.pdf Engineering Details\202.00.pdf Engineering Details\203.00.pdf Engineering Details\204.30.pdf Engineering Details\204.50.pdf Engineering Details\400.4.pdf Images\Removale Bolard H021.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_20_21-3SDDET16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_20_21-3SDDET16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/200.00.pdf Engineering Details/200.10.pdf Engineering Details/201.00.pdf Engineering Details/202.00.pdf Engineering Details/203.00.pdf Engineering Details/204.30.pdf Engineering Details/204.50.pdf Engineering Details/400.4.pdf Images/106.pdf Images/Bi-Directional Vaned Grate.tif z z z o OUTFALL TD STREAM TOP 4 EQUAL SPACES SECTION DUMP NO POLLUTANTS 4 EQUAL SPACES SLOT - SEE DETAIL AND NOTE 1 NOTES SECTION 3/4" BOLT-DOWN SLOT DETAIL SEE NOTE 1 ISOMETRIC Provide two slots in the grate that are vertically aligned 1. with the holes in the frame. Location of bolt-down slots varies among different manufacturers. 2. Refer to Standard Specification 9-05.15(2) for additional requirements. 3. Use only on sags and vertical curbs locations. 4. Unless otherwise specified, vaned grates shall be used with standard frame in the travel way, gutter or shoulder. vaned grates shall not be located within crossroads. Use vaned grates along rolled curbs. PUBLIC WORKS DEPARTMENT RECTANGULAR BI-DIRECTIONAL VANED GRATE STD. PLAN - 204.30 MARCH 2008 Images/CB1.tif PIPE ALLOWANCES z FRAME AND VANED GRATE PIPE MATERIAL REINFORCED OR PLAIN CONCRETE ALL METAL PIPE CPSSP * (STD. SPEC. 9-05.20) SOLID WALL PVC MAXIMUM INSIDE DIAMETER 12" 150 6" OR 121 ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12' HEIGHT RECTANGULAR ADJUSTMENT SECTION (STD. SPEC. 9-05.12(1)) PROFILE WALL PVC 15" (STD. SPEC. 9-05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE Or 6) NOTES #3 BAR EACH CORNER #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR EACH CORNER 18" MIN. #3 BAR HOOP SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION 1. 2. 3. 4. 5. 6. 7. 8. As acceptable alternatives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. The frame and grate must be installed with the flange down. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. The opening shall be measured at the top of the precast base section. All pickup holes shall be grouted full after the basin has been placed. All grade rings and castings shall be set in mortar in accordance with Standard Specification 9-04.3. PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE Pl STD, PLAN - 200,00 MARCH 2008 Images/CB2.tif o o o z o z z z O MORTAR FILLET 48", 54B, 60B, 72", 84N OR 96" STEPS OR LADDER CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP MORTAR (TYP.) REINFORCING STEEL (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING SEPARATE BASE CAST-IN-PLACE non RING 4 SEPARATE BASE PRECAST NOTES INTEGRAL BASE PRECAST WITH RISER GRAVEL BACKFILL FOR PIPE ZONE BEDDING CATCH BASIN DIMENSIONS CATCH WALL BASE BASIN THICKNESS THICKNESS MAXIMUM KNOCKOUT SIZE 42" 48" 72" DISTANCE BETWEEN KNOCKOUTS 8" 8" BASE REINFORCING STEEL in2/ft. IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE DIAMETER 48" 54" 72" 4" 4.5" 8" 8" 8" 8" 0.23 0.19 0.25 0.35 0.39 0.39 0.15 0.19 0.25 0.24 0.29 0.29 PIPE ALLOWANCES 1. 2. 3. 4. 5. No steps are required when height is 4' or less. The bottom of the precast catch basin may be sloped to facilitate cleaning. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. All grade rings, risers, and castings shall be set in mortar in accordance with Standard Specification 9-04.3. CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER SOLID PROFILE BASIN ALL CPSSP WALL WALL CONCRETE DIAMETER 48" 54" 72" 84" 42" METAL 54" 24" 42" 54" O PVC@ 0 27" 48" 48" 48" O Corrugated Polyethylene Storm Sewer Pipe (Std. @ (Std. spec. 9-05.12(1)) O (Std. spec. 9-05.12(2)) spec. 9-05.20) 201.00 PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE 2 STD. - MARCH 2008 Images/CBINSTALLATION.tif z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mages/Fixed Bollard H022.tif TYPE PRESSURE 7-1 0' x 4" TREATED 7—1 CEDAR HORIZ. TOP TYPE ROST & BOTTOM & VERTICAL (PER SIDE) CHAMFER CRUSHED SURFACING) -F CRUSHED NOTE: SURFACINC o MINIMUM CLEARANCE BETWEEN REBAR CONCRETE SURFACE. DATE a APPR'D 0 450 CHAMFER ALL AROUND TOP p AINT TOP 5" WHITE ALL AROUND REFLECTIVE MARKER (TYPICAL BOTH SIDES) l" DEEP NOTCH ALL AROUND 5" 1 0 450 CHAMFER ALL EDGES SLOPE CONCRETE FOR. DRAINAGE 2 'x3 8" JOINT MATERIAL *CONCRETE SIDEWALK 16" 18" 10' FIXED WOODEN BOLLARD ADOPTED CITY OF RENTON STANDARD PLANS LST DATE: 04/04 REVISION BY DWC. NAME: HO 22 PACE: Images/OpenFace.tif LEVEL HOOD 1/2" MIN z SEE NOTE 3 29" MIN. 20 1/4" SEE NOTE 4 (TYP.) SEE NOTE 2 (TYP.) TOP VIEW FRAME DETAIL CURB OR CURB AND GUTTER MATCH TOP OF HOOD TO TOP OF CURB (TYP.) HOOD 6 OPENING HEIGHT TOP OF GRATE FRAME DETAIL SECTION CATCH BASIN GRATE = 34" (WIDE SIDE) CATCH BASIN TYPE 1 = 40" (WIDE SIDE) CATCH BASIN TYPE IL SEE NOTE 1 SECTION NOTES DO NOT INSTALL SAFETY BAR/ DEBRIS GUARD 20" x 24" VANED GRATE FRAME 1. 2. 3. 4. 5. 6. The asymmetry of the Combination Inlet shall be considered when calculating the offset distance for the catch basin. See SECTION A. The dimensions of the Frame and Hood may vary slightly among dif- ferent manufacturers. The Frame may have cast features intended to support a grate guard. Hood units shall mount outside of the Frame. The methods for fastening the Safety Bar / Debris Guard Rod to the Hood may vary. The Hood may include casting lugs. The top of the Hood may be cast with a pattern. Attach the Hood to the frame with two 3/4" x 2" hex head bolts, nuts, and oversize washers. The washers shall have diameters adequate to assure full bearing across the slots. When bolt-down grates are specified in the contract, provide two holes in the frame that are vertically aligned with the grate slots. Tap each hole to accept a 5/8" x - 11 NC x 2' allen head cap screw. Location of bolt-down holes varies among different manufacturers. See BOLT- DOWN DETAIL Only ductile iron Vaned Grates shall be used. This plan is intended to show the installation details of a manufac- tured product. It is not the intent of this plan to show the specific details necessary to fabricate the castings shown on this drawing. ISOMETRIC VIEW PUBLIC WORKS DEPARTMENT STD, PLAN - 203,00 OPEN CURB FACE FRAME AND GRATE INSTALLATION DETAIL MARCH 2008 Images/RemovableBollard-STDH021.tif TYPE PRESSURE TREATED CEDAR POST 0 45' CHAMFER. ALL EDGES HORIZ. TOP & BOTTOM & VERTICAL (PER SIDE) TYPE @ 45' CHAMFER ALL AROUND TOP PAINT TOP 5" WHITE ALL AROUND REFLECTIVE MARKER (TYPICAL BOTH SIDES) 1" DEEP NOTCH ALL AROUND GALVANIZED STEEL HASP FOR LOCK 2"x6" STEEL HIACE WELDED TO 9-1 4"xg-1 4" DOOR WITH 4" RADIUS ON CPEN CORNERS ND PLATE SPACER. 1 4" GALVANILED STEEL PLATE SPACER STEEL 4" CHAMFER _I_fi4L NO 5" JO" "12 18 12' APPR'D 2 ANCHOR BOLT, WELDED TO SPACER 2"x3 8" JOINT MATERIAL CONCRETE SIDEWALK ASPHALT CRUSHED SURFACINC CRUSHED SURFACING 8 WEEN MINIMUM CONCRE DATE CLEARANCE E SURFACE, REVISION 4" BY REMOVABLE WOODEN ADOPTED CITY OF RENTON STANDARD PLANS BOLLARD DWC. NAME: LST DATE: 04 04 HODI RACE. • HODI Images/Removale Bolard H021.pdf Images/ROUNDSDCOVER.tif O RENTON AHEAD OF THECURVE DRAIN o PLAN 25" DIA. [635mm] 1/2" [13mm] LETTERING BOLTHOLES - 3 PLCS EQUALLY SPACED 1200 APART ON 23 1/16" (586mm) DIA B.C. (1) 1" (25mm) DIA PICKHOLE 1 1/4" [32mm] LETTERING [16mml [19mm] [222mm] TYP COVER SECTION VIEW 26 1/2" DIA [673mm] 25 1/4" DIA [641 mm] 1/4" (6mm) DIA NEOPRENE GASKET 23 3/8" DIA CL OPEN [594mm] 27 5/16" DIA [694mm] 34 1/8" DIA [867mm] FRAME SECTION VIEW [25mrn] [64mm] [27mm] 6" [152mm] NOTES 08LUEOO cu COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 ss RUBBER WASHER EON BOLTING DETAIL [6mm] [27mm] [3mm] [R3mm] GASKET GROOVE DETAIL ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1 OR APPROVED EQUAL. PUBLIC WORKS DEPARTMENT STORM ROUND FRAME AND COVER STD. PLAN - 204.50 MARCH 2008 Images/Type 1L CB.tif PIPE ALLOWANCES FUME AND VANED CUTE 6' OR 12' ONE BAR HOOP FOR 6' HEIGHT TWO BAR HOOPS FOR 1? HEIGI-T RECTANGULAR ADJUSTMENT SECTION TWO BAR REDUCING SECTION BAR EACH CORNER BAR EACH SIDE BAR EACH WAY PRECAST BASE SECTION PIPE MATERIAL REINFORCED OR PLAIN CONCRETE ALL METAL PIPE CPSSP * (STD. SPEC. 905.20) SOLID WALL MAXIMUM INSIDE DIAMETER (STD. SPEC. 9-4h12(1)) PROFILE WALL PVC (STD. SPEC. * CORRU@ATED POLYETHYLENE STORM SEWER PIPE NOTES 1. 2. 3. 4. 5. 6. 7. 8. As acæptable attemaives the rebar showm in the PRECAST BASE SECTION, fibers (placed to the Standard Specifiætions), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum requited rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. The knockout diameter shall not be greater than 26". shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the ouEide of the pipe. Ater the pipe is fill the gap with joint mortar in with Standard Spedficatbn 9-04.3. The maximum deph from the finished grade to he lowest pipe invert shall be 5. The frame and grü must be installed with the hange down. The Precast Base Section may have a rounded noor, and the walls may be sbped at a rate of 1 :24 or steeper. The opening shall be measured at the bp of the precast base sectbn. All pickup holes shall be full after the basin has been plaæd. All grade rings and castings shall be set in mortar in accordance with Sbndard Specificatbn 9-04.3. BAR EACH CORNER #3 BAR 18' MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE 11.. STD. PLAN - 200.10 MARCH 2008 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_07_08-3TESCDT16041 - DRS2000.zip RD_07_08-3TESCDT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:16 PM. Drawing: This is a transmittal based on RD_07_08-3TESCDT16041.dwg. Files: Root Drawing: Engineering\RD_07_08-3TESCDT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\CBFilter.tif Images\CheckDam.tif Images\ConstructionEntrance.tif Images\InterceptorSwale.tif Images\SiltFence.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\CatchBasinInsert.pdf Engineering Details\CheckDams.pdf Engineering Details\ConstructionEnterance.pdf Engineering Details\InterceptorSwale.pdf Engineering Details\SiltFence.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_07_08-3TESCDT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_07_08-3TESCDT16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/CatchBasinInsert.pdf Engineering Details/CheckDams.pdf Engineering Details/ConstructionEnterance.pdf Engineering Details/InterceptorSwale.pdf Engineering Details/SiltFence.pdf Images/CBFilter.tif m z DRAINAGE GRATE GRATE FRAME SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW DRAINAGE GRATE - RECTANGULAR GRATE SHOWN BELOW INLET GRATE DEVICE NOTES 5" MAX. TRIM OVERFLOW BYPASS BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) ISOMETRIC VIEW 2. 3. 4. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. The BIGD shall have a built-in high-flow relief system (overflow bypass). The retrieval system must allow removal of the BIGD without spilling the collected material. Perform maintenance in accordance with Standard Specification 8-01.3(15). PUBLIC WORKS DEPARTMENT CATCH BASIN FILTER STD. PIAN - 216.30 MARCH 2008 Images/CheckDam.tif ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION SLOPES NOTES CONDITION OF USE 24" MIN. 2"-4" ROCK 1. 1.1. 2. WERE CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM PONDS OR TRAPS. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON-EROSIVE DISCHARGE POINT. MAINTENANCE STANDARDS ANY SEDIMENT DEPOSITION OF MORE THAN 0.5 FEET SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET. PUBLIC WORKS DEPARTMENT STD. PLAN - 217.40 CHECK DAMS SPACING AND CROSS SECTIONS MARCH 2008 Images/ConstructionEntrance.tif z R = 25t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mages/InterceptorSwale.tif MAX. SLOPE LEVEL BOTTOM z SWALE SPACING DEPENDS ON SLOPE GRADIENT NOTES 1. CONDITION OF USE 1.1. REQUIRED AT: 1.1.1. 1.1.2. THE TOP OF ALL SLOPES IN EXCESS OF 3H:1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELLOW. AVERAGE SLOPE SLOPE PERCENT FLOWPATH LENGTH 20H:1V (10 TO 20) H:IV (4 TO (2 TO 2. DESIGN AND INSTALLATION SPECIFICATIONS 5-10% 25-50% 300 FEET 200 FEET 100 FEET 50 FEET 2.1. 2.2. FOR SLOPES STEEPER THAN 2H:1V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRE MEASURE MOST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED. 3. MAINTENANCE STANDARDS 3.1. 3.2. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. IF THE FACILITY DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED. PUBLIC WORKS DEPARTMENT UNTERCEPTOR SWALE STD. PLAN - 217.10 MARCH 2008 Images/SiltFence.tif z JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC •ro POSTS. 6t MAX 2"x2" BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC MINIMUM 4"x4't TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2"x4n WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT POST SPACING MAY BE INCREASED To IF WIRE BACKING IS USED NOTES 1. CONDITION OF USE 1.1. 12. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. 2.2. 2.3. 2.4. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. AOS (ASTM D4751) WATER PERMITTIVITY (ASTM D491 GRAB TENSILE STRENCHT (ASTM D4632) SIEVE SIZE (0.60-0.15MM) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15MM) FOR OTHER FABRICS 0.02 SECA-I MINIMUM 180 LBS. MIN. FOR EXTRA STRENGH FABRIC 100 LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION ASTM D4632 MAX. ULTRAVIOLATE RESISTANCE (ASTM D4355) MIN. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. 3.2. 3.3. 3.4. 3.5. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. PUBLIC WORKS DEPARTMENT SILT FENCE STD, PLAN - 214.00 MARCH 2008 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_07_08-3TESCDT16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:16 PM. Drawing: This is a transmittal based on RD_07_08-3TESCDT16041.dwg. Files: Root Drawing: Engineering\RD_07_08-3TESCDT16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\CBFilter.tif Images\CheckDam.tif Images\ConstructionEntrance.tif Images\InterceptorSwale.tif Images\SiltFence.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Paving - Surfacing.Asphalt.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\CatchBasinInsert.pdf Engineering Details\CheckDams.pdf Engineering Details\ConstructionEnterance.pdf Engineering Details\InterceptorSwale.pdf Engineering Details\SiltFence.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\arial.ttf Fonts\ROMANC.shx Fonts\romant.shx Fonts\ROMANS.shx Fonts\ltypeshp.shx Fonts\ARIALN.TTF Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx The following files could not be located: archquik.(shx,ttf) Batang.(shx,ttf) Textures\Sitework.Paving - Surfacing.Asphalt.jpg Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_07_08-3TESCDT16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_07_08-3TESCDT16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/CatchBasinInsert.pdf Engineering Details/CheckDams.pdf Engineering Details/ConstructionEnterance.pdf Engineering Details/InterceptorSwale.pdf Engineering Details/SiltFence.pdf Images/CBFilter.tif m z DRAINAGE GRATE GRATE FRAME SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW DRAINAGE GRATE - RECTANGULAR GRATE SHOWN BELOW INLET GRATE DEVICE NOTES 5" MAX. TRIM OVERFLOW BYPASS BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) ISOMETRIC VIEW 2. 3. 4. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. The BIGD shall have a built-in high-flow relief system (overflow bypass). The retrieval system must allow removal of the BIGD without spilling the collected material. Perform maintenance in accordance with Standard Specification 8-01.3(15). PUBLIC WORKS DEPARTMENT CATCH BASIN FILTER STD. PIAN - 216.30 MARCH 2008 Images/CheckDam.tif ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION SLOPES NOTES CONDITION OF USE 24" MIN. 2"-4" ROCK 1. 1.1. 2. WERE CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM PONDS OR TRAPS. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON-EROSIVE DISCHARGE POINT. MAINTENANCE STANDARDS ANY SEDIMENT DEPOSITION OF MORE THAN 0.5 FEET SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET. PUBLIC WORKS DEPARTMENT STD. PLAN - 217.40 CHECK DAMS SPACING AND CROSS SECTIONS MARCH 2008 Images/ConstructionEntrance.tif z R = 25t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mages/InterceptorSwale.tif MAX. SLOPE LEVEL BOTTOM z SWALE SPACING DEPENDS ON SLOPE GRADIENT NOTES 1. CONDITION OF USE 1.1. REQUIRED AT: 1.1.1. 1.1.2. THE TOP OF ALL SLOPES IN EXCESS OF 3H:1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELLOW. AVERAGE SLOPE SLOPE PERCENT FLOWPATH LENGTH 20H:1V (10 TO 20) H:IV (4 TO (2 TO 2. DESIGN AND INSTALLATION SPECIFICATIONS 5-10% 25-50% 300 FEET 200 FEET 100 FEET 50 FEET 2.1. 2.2. FOR SLOPES STEEPER THAN 2H:1V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRE MEASURE MOST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED. 3. MAINTENANCE STANDARDS 3.1. 3.2. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. IF THE FACILITY DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED. PUBLIC WORKS DEPARTMENT UNTERCEPTOR SWALE STD. PLAN - 217.10 MARCH 2008 Images/SiltFence.tif z JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC •ro POSTS. 6t MAX 2"x2" BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC MINIMUM 4"x4't TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2"x4n WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT POST SPACING MAY BE INCREASED To IF WIRE BACKING IS USED NOTES 1. CONDITION OF USE 1.1. 12. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. 2.2. 2.3. 2.4. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. AOS (ASTM D4751) WATER PERMITTIVITY (ASTM D491 GRAB TENSILE STRENCHT (ASTM D4632) SIEVE SIZE (0.60-0.15MM) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15MM) FOR OTHER FABRICS 0.02 SECA-I MINIMUM 180 LBS. MIN. FOR EXTRA STRENGH FABRIC 100 LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION ASTM D4632 MAX. ULTRAVIOLATE RESISTANCE (ASTM D4355) MIN. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. 3.2. 3.3. 3.4. 3.5. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. PUBLIC WORKS DEPARTMENT SILT FENCE STD, PLAN - 214.00 MARCH 2008 PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Paving - Surfacing.Asphalt.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_11_12-3RAMDETP16041 - DRS2000.zip RD_11_12-3RAMDETP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_11_12-3RAMDETP16041.dwg. Files: Root Drawing: Engineering\RD_11_12-3RAMDETP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\101officialsigned.tif Images\102officialsigned.tif Images\104.2.tif Images\104.3.tif Images\ADARAMP Cornerf40.15-03_e.tif Images\ADARAMP f40.16-03_e.tif Images\f45_10-02_e.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\104.3.pdf Images\134officialsigned GROUND MOUNTED STREET NAME SIGNS.pdf Images\135officialsigned CONSTRUCTION NOTES.pdf Images\COR STD PLAN 129.STEEL SIGN SUPPORT.pdf Engineering Details\G 134.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_11_12-3RAMDETP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_11_12-3RAMDETP16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/104.3.pdf Engineering Details/G 134.pdf Images/101officialsigned.tif FACE OF CURB 6" 51/2" 1/2" R. 1:24 112" 6" R. TOP OF ROADWAY VARIES FROM 6" TOO 1 2" CEMENT CONCRETE SIDEWALK RAMP OR LANDING 3/8" PREMOLDED JOINT FILLER 1:12 1'-6" CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE TOP OF ROADWAY 11-6" DEPRESSED CURB SECTION AT SIDEWALK RAMPS CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF ROADWAY 11-6" DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 FACE OF CURB PREMOLDED JOINT FILLER 3/8" . za%o E FULL-DEPTH EXPANSION JOINT FACE OF ADJACENT CURB CUTTER SURFACE DEPRESSED CURB DETAIL TOP OF ROADWAY CEMENT CONCRETE TRAFFIC CURB AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: I. 2. 3. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler. For Depræsed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2 STD. PLAN - 101 PUBLIC WORKS CEMENT CONCRETE CURBS DEPARTMENT Images/102officialsigned.tif 6" SIDEWALK 1.5% 1• (IN) R. ALL CUT SLOPES BRIDGE OR PEDESTRIAN RAILING RAISED EDGE DETAIL EXTEND SIDEWALK TRANSVERSE JOINTS TO INCLUDE RAISED EDGE SIDEWALK 1,'2- (IN) R. cryp.) 1.5% ADJACENT TO CURB SIDEWALK 1/2" (IN) R. (TYP.) 1.5% 3'8• (IN) PREMOLDED JOINT FILLER ROU DING 2.0% UYP.) MIN. 2.0% SEE RAISED EDG DETAIL - THIS SHE FOR CURB DETAILS SEE STD PLAN 101 ROU DING MIN 2.0% FOR CURB DETAILS SEE STD PLAN 101. BARRIER - SEE CONT RACT PLANS FLUSH VERTICAL WALL - SEE DETAIL TYPICAL UNDER SIDEWALK WITH RAISED EDGE SIDEWALK 1/2' (IN) R. (TYR) 1.5% ADJACENT TO CURB (STEEP FILL SLOPES) ALL OR BARRIER SIDEWALK ADJACENT TO CURB AND RAILING OR WALL FOR SIDE TREATMENT SIDEWALK SECTIONS SIDEWALK 1.5% BUFFER STRIP (SEE NOTE 10) (TYP.) 1.5% MIN. FINISHED GRADE (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING - FLUSH IF PAVED ADJACENT TO BUFFER STRIP (IN) PREMOLDED JOINT FILLER SIDEWALK ADJACENT TO WALL DETAIL FOR CURB DETAILS SEE STD PLAN 101 (f) (IN) PREMOLDED JOINT FILLER TYPICAL WHERE APPLICABLE FOR CURB DETAILS SEE STD PLAN 101 STING ROADWAY CRUSHED RCM CRUSHED SURFACING TOP COURSE (CSTC) OMPACT TO 957. MODIFIED PROCTOR (UNLESS REQUIREMENT WANED BY ENGINEER) TYPICAL UNDER ALL CURB, GUTTER & SIDEWALK. CSTC UNDER CURB & GUTTER TO BE 6- THICKNESS OR MATCH EXISTING ROADWAY CRUSHED ROCK BASE. WHICHEVER IS GREATER (TYP. FOR ALL CURB & GUTTER). FINISHED GRADE 1' (IN) BELOW TOP OF CONCRETE SURFACE FOR CURB DETAILS SEE STD PLAN 101 BROOMED FINISH OR MATCH EXISTING 4" WIDE. TROWELED PERIMETER CEMENT CONCRETE CURB (CURB AND GUTTER SHOWN) FOR CURB DETAILS SEE STD PLAN 101. 1/8' TO 1/4- NOTES I. Four feet of the sidewalk width shall be the minimum pedestrian route (PAR) free of vertical and horizontal obstructions. Gratings, Access Covers, Junction Boxes, Cable Vaults, Pull Boxes and other appurtenanæs within the sidewalk must be flush with and match grade of the sidewalk. 2. Monolithic Cement Concrete Curb and Sidewalk is not permitted in new construction. When replacement work necessitates a Monolithic Cement Concrete Curb build per WSDOT Standard Plan FOO. 10-03. 3. Concrete to be PSL PUBLIC WORKS DEPARTMENT CONTRACTION JOINT IN SIDEWALK Ot•JLY FULL-DEPTH EXPANSION JOINT IN BOTH CURB AND SIDEWALK (SEE STD 101.1) JOINT AND FINISH DETAIL PREMOLOE JOINT FILLER E FULL-DEPTH EXPANSION JOINT c CONTRACTION JOINT For other referenced NOTES see STD PLAN 104.2. Paved surfaces must comply with STD PLAN 102.1 as applicable. STD. PIAN — 102 CEMENT CONCRETE SIDEWALK Images/104.2.tif CEM@tr CONCRETE SIDEWALK NOTES \ CEMENT CONCRETE CURB (SEE NOTE 3) DERESSED MONOUTH(C CIRB a (SEE THS SHEED TYPE C2B - ISOMETRIC VIEW (COMMERCIAL, WITH BUFFER) FACE OF CURB 2. 3, 4. 5, 6. 7. 8. 9, 10. When a driveway width exceeds 15 feet, Ønsfruct a full depth expansion Joint with 318m Jolnt filler elong the driveway lane Ilnes (see std. plan 102). expansion parallel with the as required at 15' rnaxlmum spacing when driveway wtdths exceed 30'. See std. plan 102 for sldewalk details, Curt and guüer shown, other curb designs may be specified, See std. plan 101 for curb details. Not The englneer design all driveways to Include elevatlons at all matted with symbol All elevations are at {he back of curb top on uphill side. Not For Dtiveway Widths DRIVEWAY STANDARDS (See NOTE 10). The expangion Ärds (see std. plan 102) shall be spaced as shown In the IgomotrE view. Stopes shall comply with sections R303.2,1 or R3032,2 or R3032.3 of the Reviged Guidelines for Public Rights-of-Way of Novanber 23, 2005 (PROWAG). Curb returns for any Type C-MAX Driveway may be on a STREET STANDARDS - Renton Municipal code (RMC) Title IV Development R+latlons CHAPTER 6 STREET AND UTILITY STANDARDS Section 4-6060 STREET STANDARDS DRIVEWAY STANDARDS = Renton Municipal Code (RMC) Title IV Development Regulations CHAPTER 4 CffY-WlDE PROPERTY DEVELOPMENT STANDARDS Section 44080 PARKING, LOADING AND DRIVEWAY REGULATIONS BEE (D CONTR.ACTION STD PLAN 102 l'-ffl NOTE: DNVEWAYLOFGITUDINN- OINT8 Stun.l- BE FULL DEPRE88ED CURB DETAIL ON THB SHEET TOP OF /- ROADWAY DEPRESSED MONOLTTHIC CURB GUTTER DETAIL OF ADJACENT SURFACE DEPRESSED CURB DETAIL AT RESIDENTIAL COMMERCIAL DRIVEWAYS, A-LEYS Driveway Example: TYPE CIB R=Reeldenüal, NurnkEr of Lanse (MAX=4 Lano Cortunerda() BEBuffer (Purding Strip). Bufe• PUBLIC WORKS DEPARTMENT CEMENT CONCRETE DRIVEWAY ENTRANCES NOTES AND DETAILS srm PLAN 1042 PROV D: ATE Images/104.3.tif MIN. (SEE NOTE B) 10 LF OF PAVED DRIVEWAY REQUIRED 3'8• EXPANSION JOINT (TYPO (SEE STD. PLAN RAMP WITH 12H tv SLOPE (TYP.) 3,a• CONTRACTION JOINT (TYP (SEE STD. PLAN 102} DIFFERENCE IN SLOPE MAX o DRIVEWAY RELATIVE NEGATIVE SLOPE (SLOP SHOWN EXAGGERATED) CEMENT CONCRETE SIDEWALK o PUBLIC WORKS DEPARTMENT & NTO CCN BID ITEM (INCLUDES SIDEWALK RAMPS) VARIES (SEE NOTE 7 SEE NOTE 5 TRUCTION JOINT SEE NOTE 1 PLAN VIEW 6 MIN. (SEE NOTE B) CEMENT CONCRETE CURB & GUTTER {SEE NOTE 3) CEMENT CONCRETE SIDEWALK 8 34. B.fAX. SEE NOTE 8 DEPRESSED CURB a GUTTER MIN CEMENT CONCRETE SIDEWALK DRIVEWAY W VARIES (SEE NOTE 10) 6• MIN SECTION A MIN 3,e• EXPANSION JOINT (TYP ISEE STD. PLAN 102) R (Typo SLOPE (SLOPE SHOWN EXAGGERATED) DRIVEWAY SE CEMENT CONCRETE CURB & GUTTER (SEE NOTE 3) DEPRESS MONOLiTHiC CURB OTTER ETAIL. STD PLAN 104.2) TYPE RIB - ISOMETRIC VIEW (RESIDENTIAL, WITH BUFFER) CEMENT CONCRETE DRIVEWAY ENTRANCE - TYPE RIB (SEE NOTE 3) SIDEWALK MOTH 6- MIN. ON For NOTES STD. PLAN 104.2 STD. PLAN - 104.3 PPR VED: ATE Gregg Zimmerman, Public Works Administrator Images/134officialsigned GROUND MOUNTED STREET NAME SIGNS.pdf Images/135officialsigned CONSTRUCTION NOTES.pdf Images/ADARAMP Cornerf40.15-03_e.tif NOTES CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS GRADE BREAK SEE CONTRACT PLANS LANDING CURB RAMP CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS GRADE BREAK GRADE BREAK SEE CONTRACT PLANS - 4 - 0" MIN. CEMENT CONCRETE SIDEWALK- SEE NOTE 5 FLARE (IYP.) 318" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F.30.10 GRADE BREAK CURB. OR CURB AND GUTTER SEE NOTE 4 FACE OF CURB MEASURED PARALLEL TO CURB (TYP.) z LANDING AND GUTTER - SEE NOTE 4 CEMENT CONCRETE SIDEWALK - SEE NOTE 5 PROVIDE SMOOTH TRANSITION TO SIDEWALK WDTH MIN. CURB RAMP GRADE BREAK SEE CONTRACT PLANS - 318" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 TRANSITION TO SIDEWALK BUFFER, IF PRESENT, OR TO BACK OF CURB (IMP.) SEE CONTRACT PLANS CURB, OR CURB AND GUTTER - SEE CONTRACT PLANS - 4' - 0" MIN. BUFFER WIDTH - MATCH TO CURB RAMP DEPTH (TYP.) CEMENT CONCRETE PEDESTRIAN CURB - SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F-45.10 DEPRESSED CURB AND GUTTER - SEE NOTE 4 SEE NOTE 4 FACE OF CURB DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.45.10 DEPRESSED CURB AND GUTTER 1. 2. 3. 4. 5. 6. 7. 8. 9. CROSSWALK PLAN VIEW CROSSWALK PLAN VIEW TYPE PERPENDICULAR B (SHOm WITH BUFFER) At marked crosswalks, the connection between the curb ramp and the road- way must be contained within the width of the crosswalk markings. Wiere "GRADE BREAK' is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. Do not place Gratings, Junction Boxes, Covers, or other appurÉn- ances on any pan of the Curb Ramp or Landing, or in front of the Curb Ramp where it connects to the roadway. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Guter, Depressed Curb and Guter, and Pedestrian Curb See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and plaæment of sidewalk. The Bid Item "Cement Concrete Curb Ramp Type " does not include the adjacent Curb, Curb and Guter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. The Curb Ramp length is not required to exceed 15 feet (unless shown otherwise in the Contract Plans). When applying the 15-foot max. length, the running slope of the Curb Ramp is allowed to exæed 8.3%. use a single slope from bottom of ramp to top of ramp to match into the landing over a horizontal distance of 15 feet. Do not include the abutting landing in the 15-foot max. measurement. Curb Ramps and Landings shall receive a broom finish. See Standard Specifications 8-14. Pedestrian Curb may be omitted if the ground surfrce at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to retain. CONTRACTION JOINT ayp.) - SEE STANDARD PLAN F.30.10 FOR CURB RAMP LENGTHS GREATER THAN 8' - 0" PROVIDE CONTRACTION JOINT EQUALLY SPACED 4' - 0" MIN. OC. TYPE PERPENDICULAR A LEGEND SEE CONTRACT PLANS DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.46.10 15 - 0" MAX. (TYP.) SEE NOTE 7 GRADE BREAK SLOPE TREATMENT - SEE STANDARD PLAN F.30.10 LANDING CEMENT CONCRETE PEDESTRIAN CURB - SEE NOTE 4 GRADE BREAK COUNTER SLOPE - 5.0% MAX. TOP OF ROADWAY DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F.10.12 CEMENT CONCRETE CURB RAMP "TYPE PERPENDICULAR "B" PAY LIMIT - SEE NOTE 6 SLOPE IN EITHER DIRECTION 1.5 OR FLATTER RECOMMENDED FOR DESIGWFORMWORK MAX.) 7.5% OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (8.3% MM.) 9.5% OR FLATTER RECOMMENDED FOR DESIGWFORWJORK (10% MAX.) CURB RAMP SECTION A CEMENT CONCRETE CURB RAMP "TYPE PERPENDICULAR "A" PAY LIMIT - SEE NOTE 6 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F45.10 DEPRESSED CURB AND GUTTER - SEE NOTE 4 CEMENT CONCRETE CURB CURB RADIUS DETAIL ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT zeller, Jun 24 2016 7:20 AM PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpcntcr, .lcff eazÉuztez 'ed Jun 29 2016 2:28 PM COSI STATE DESIGN ENGINEER Washington State Deprtment of Tmr•portation Images/ADARAMP f40.16-03_e.tif NOTES MATCH SIDEWALK WIDTH - 4' 0" MIN. - SEE CONTRACT PLANS 318" (IN) EXPANSION JOINT - SEE STANDAR PLAN F.30.10 SIDEWALK - SEE NOTE 6 BUFFER STRIP - SEE CONTRACT PLANS PEDESTRIAN CROSSING CLOSURE SIGN z GRADE BREAK SIDEWALK - SEE NOTE 6 PEDESTRIAN CURB - SEE NOTE 10 (TYP.) c LANDING PEDESTRIAN CURB SEE NOTE 10 MATCH SIDEWALK WIDTH 4' 0" MIN. SEE CONTRACT PLANS 318" (IN) EXPANSION JOINT - SEE STANDARD PLAN F.30.10 O SIDEWALK o SEE NOTE 6 MATCH SIDEWALK WDTH - 4' 0" MIN. SEE CONTRACT PLANS CURB RAMP LANDING DETECTABLE WARNING SURFACE BUFFER SEE STANDARD PLAN F45.10 STRIP PEDESTRIAN CROSSING CLOSURE SIGN BUFFER STRIP PEDESTRIAN CURB - SEE NOTE 10 o DETECTABLE WARNING SURFACE c SEE STANDARD PLAN F.45.10 CURB AND GUTTER - SEE NOTE 5 FACE OF CURB CURB AND GUTTER - SEE NOTE 5 CURB RAMP PLAN VIEW FACE OF CURB CURB RAMP 15' - 0' MAX (TYP.) SEE NOTE 8 TYPE SINGLE DIRECTION A DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.45.10 GRADE BREAK 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. GRADE BREAK LANDING 1 GRADE BREAK COUNTER SLOPE 5.0% MAX. TOP OF ROADWAY SIDEWALK - SEE NOTE 6 DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F.10.12 PLAN VIEW TYPE SINGLE DIRECTION B 15 - 0" MAX (TYP. SEE NOTE 8 GRADE BREAK CURB RAMP 15' - 0" MAX (TYP. SEE NOTE 8 LANDING GRADE BREAK SIDEWALK - SEE NOTE 6 CURB RAMP This plan is to be used where pedestrian crossing in one direction is not permitted. At marked crosswalks, the connection between the Landing and the roadway must be contained within the width of the crosswalk markings. Where "GRADE BREAK" is called out, the entire length of the grade break between the two adjacent sufface planes shall be flush. Do not place Gratings, Junction Boxes, Access Covers, or other appurten- ances on any part of the Curb Ramp or Landing or in the Depressed Curb and Gutter where the Landing connects to the roadway. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb, Gutter and Pedestrian Curb See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and plaæment of sidewalk. The Bid Item "Cement Concrete Curb Ramp Type " does not include the adjacent Curb, Curb and Guter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. The Curb Ramp length is not required to exceed 15 feet (unless shown otherwise in the Contract Plans). Men applying the 15-foot max. length (measured from back of sidewalk) the running slope of the curb ramp is allowed to exæed 8.3%. Use a single constant slope from botom of ramp to top of ramp to match into the sidewalk over a horizontal distance of 15 feet. Curb Ramps and Landings shall reEve a broom finish. See Standard Specifications 8-14. Pedestrian Curb may be omitted if the ground surfaæ at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to LEGEND SLOPE IN EITHER DIRECTION 1.5 OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (2% MAX.) 7.5% OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (8.3% MAX.) SEE NOTE 7 CURB RAMP SECTION CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 FOR CURB RAMP LENGTHS GREATER THAN - 0" PROVIDE CONTRACTION JOINT EQUALLY SPACED 4' - 0" MIN. OC. 1 SECTION B (ALONG INSIDE RADIUS AT BACK OF WALKWAY) "CEMENT CONCRETE CURB RAMP TYPE SINGLE DIRECTION B" PAY LIMIT - SEE NOTE 7 "CEMENT CONCRETE CURB RAMP TYPE SINGLE DIRECTION A" PAY LIMIT - SEE NOTE 7 1" (IN) RADIUS CORNER PEDESTRIAN CURB 90' ANGLE RADIUS MAY VARY ISOMETRIC VIEW TYPE SINGLE DIRECTION A PAY LIMIT DETECTABLE WARNING SURFACE SEE STANDARD PLAN F46.10 DEPRESSED CURB AND GUTTER SEE NOTE 5 DETAIL c ISOMETRIC VIEW TYPE SINGLE DIRECTION B PAY LIMIT Zeller, Scott Jun 24 2016 7:21 AM SINGLE DIRECTION CURB RAMP STANDARD PLAN F-40.16-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpenter, JelT ewvP"tet, 'e" 29 20162 29 PM STATE DESIGN ENGINEER Washington State Deprtment of Tmr•portation Images/COR STD PLAN 129.STEEL SIGN SUPPORT.pdf Images/f45_10-02_e.tif NOTES c TRUNCATED DOME SECTION A SEE STANDARD SPECIFICATIONS FOR COLOR OF SURFACE TRUNCATED DOME DETAILS C E MIN. 0.65" 0.45" 0.2" MAX. 2.40" 0.90" 1.40" 0.2" CURB RAMP, LANDING, CUT- THROUGH OR WALKWAY BACK OF CURB SEE NOTE 2 CURB AND GUTTER DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 IMP. OF ALL 1. 2. TRUNCATED DOME SPACING SEE NOTE 3 CURB RAMP WALKWAY APPLICATIONS 3. 4. MATCH TO WIDTH OF CURB RAMP LANDING, CUT-THROUGH OR WALKWAY DETECTABLE WARNING SURFACE DETAIL LANDING OFFSET SEE NOTE 8 5. 6. 7. 8. WIDTH OF WALKWAY DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 4 BACK OF CURB WALKWAY LANDING FLARE The Detectable Warning Surface (DWS) shall extend the full width of the curb ramp, landing, or other roadway entrance as applicable. Exception: If the Manufacturer of the DWS requires a concrete border around the DWS, a variance of up to 2 inches on each side of the DWS is permitted. The Detectable Warning Surface (DWS) shall be placed at the back of curb, with the Wvo leading corners of the DWS panel placed adjacent to the back of the curb, and with no more than a 2 inch gap between the DWS and the back of the curb measured at the center of the DWS panel. Exception: If the Manufacturer of the selected DWS requires a concrete border around the DWS, a variance of up to 2 inches from the back of the curb is permitted (measured at the leading corners of the DWS panel). The rows of truncated domes shall be aligned to be perpendicular to the grade break at the back of curb. The rows of truncated domes shall be aligned to be parallel to the direction of travel. If curb and gutter are not present, such as a shared-use path connection, the Detectable Warning Surface shall be placed at the pavement edge. See Standard Plans for sidewalk and curb ramp details. If a curb ramp is required, the location of the Detectable Warning Surface must be at the bottom of the ramp and within the required distance from the rail. When the grade break between the curb ramp and the landing is less than or equal to 5 ft. from the back of curb at all points, place the Detectable Warning Surface on the bottom of the curb ramp directly above the grade break. WIDTH OF CUT-THROUGH z z WALKWAY CURB RAMP FLARE DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 3 WIDTH OF CURB RAMP OF CUT- THROUGH (TY".) MIN. SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING 5 FT. FROM BACK OF CURB) (SEE NOTE 6) LANDING CURB RAMP BACK OF CURB - SEE NOTE 2 DIRECTION OF TRAVEL WALKWAY WIDTH OF WALKWAY PERPENDICULAR CURB RAMP (SEE NOTE 6) OF CURB RAMP, LANDING, OR WALKWAY DETECTABLE WARNING SURFACE (TY".) SEE NOTE 3 DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 3 DETECTABLE WARNING SURFACE (DWS) - SEE NOTES 4 & 7 DETECTABLE WARNING SURFACE (TYP.) - SEE NOTE 3 BACK OF CURB - SEE NOTE 2 ISLAND CUT-THROUGH BACK OF CURB - SEE NOTE 2 (TYP.) BACK OF CURB - SEE NOTE 2 • a a • •a aaa• MEDIAN CUT-THROUGH BACK OF CURB SEE NOTE 2 SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING > 5 FT. FROM BACK OF CURB) CURB RAMP WALKWAY BACK OF CURB - SEE NOTE 2 (SEE NOTE 6) LANDING WIDTH OF LANDING CURB RAMP WALKWAY DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 WIDTH OF SHARED- USE PATH OR WALKWAY (TY".) WIDTH OF CUT-THROUGH (TYP.) PAVEMENT EDGE SHARED-USE PATH OR WALKWAY SHOULDER RAIL PATH OR WALKWAY PEDESTRIAN RAILROAD CROSSING ROUNDABOUT SPLITTER ISLAND DETECTABLE WARNING SURFACE (DWS) - SEE NOTES 4 & 5 PLACEMENT GUIDELINES SHARED-USE PATH CONNECTION Zeller, Scott Jul 12 2016 4:25 PM DETECTABLE WARNING SURFACE STANDARD PLAN F-45.10-02 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpenter, Jeff Jul 15 2016 2:26 PM STATE DESIGN ENGINEER Washington State Department of Transportation PARALLEL CURB RAMP (SEE NOTE 6) PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg RD_11_12-3RAMDETP16041.txtTransmittal Report: Created by AutoCAD eTransmit Wednesday, July 29, 2020, 3:19 PM. Drawing: This is a transmittal based on RD_11_12-3RAMDETP16041.dwg. Files: Root Drawing: Engineering\RD_11_12-3RAMDETP16041.dwg AutoCAD Drawing (External) References: Engineering\RD_E22X34_16041.dwg TIFF image References: Images\101officialsigned.tif Images\102officialsigned.tif Images\104.2.tif Images\104.3.tif Images\ADARAMP Cornerf40.15-03_e.tif Images\ADARAMP f40.16-03_e.tif Images\f45_10-02_e.tif JPEG image References: Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures\Sitework.Planting.Grass.Short.jpg Textures\Sitework.Planting.Grass.Thick.jpg Textures\Sitework.Planting.Gravel.Crushed.jpg Textures\Sitework.Planting.Gravel.Mixed.jpg Textures\Sitework.Planting.Soil.jpg Adobe Acrobat Document References: Engineering Details\104.3.pdf Images\134officialsigned GROUND MOUNTED STREET NAME SIGNS.pdf Images\135officialsigned CONSTRUCTION NOTES.pdf Images\COR STD PLAN 129.STEEL SIGN SUPPORT.pdf Engineering Details\G 134.pdf AutoCAD Color-dependent Plot Style Table File References: PlotCfgs\NDRS-MONO-F.ctb AutoCAD Plotter Configuration File References: PlotCfgs\PDF Complete_2017 22x34.pc3 The following files were excluded from the transmittal: acad.fmp Fonts\simplex.shx Fonts\txt.shx Fonts\calibri.ttf Fonts\arialbd.ttf Fonts\tahoma.ttf Fonts\ROMANS.shx Fonts\arial.ttf Fonts\ARIALN.TTF Fonts\ltypeshp.shx Fonts\aeccland.shx Fonts\MONOTXT.shx Fonts\sanss___.ttf Fonts\bold.shx Fonts\ROMANC.shx The following files could not be located: Textures\Sitework.Paving - Surfacing.Asphalt.jpg Batang.(shx,ttf) Conversion: All drawing files were converted to AutoCAD 2000/LT2000 format. Notes for distribution: .DWG external reference files: External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Paths may be present on references to raster images. Make sure these paths work or that the root drawing is using the correct references. PDF Underlay files: Paths may be present on references to PDF underlay files. Make sure these paths work or that the root drawing is u sing the correct references. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. Material texture files: Please copy these files to the AutoCAD Texture Maps Search Path directory. The AutoCAD variable FONTALT was set to: C:\Users\ylp\appdata\roaming\autodesk\c3d 2017\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font. *** Map 2007 Data and Cache files *** The drawing 'R:\2016\0\16041\3\Drawings\As-builts\Plots\Engineering\RD_11_12-3RAMDETP16041.dwg' refers to a cache manifest XML file, zero or more cache files (.GWS) as well as raw data files. Please ensure the manifest XML file and cache files are unzipped to the drawing directory or your current MapCache directory. You may also need to update the cache manifest XML file to point to the unzipped location of the data files. Engineering/RD_11_12-3RAMDETP16041.dwg Engineering/RD_E22X34_16041.dwg Engineering Details/104.3.pdf Engineering Details/G 134.pdf Images/101officialsigned.tif FACE OF CURB 6" 51/2" 1/2" R. 1:24 112" 6" R. TOP OF ROADWAY VARIES FROM 6" TOO 1 2" CEMENT CONCRETE SIDEWALK RAMP OR LANDING 3/8" PREMOLDED JOINT FILLER 1:12 1'-6" CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE TOP OF ROADWAY 11-6" DEPRESSED CURB SECTION AT SIDEWALK RAMPS CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF ROADWAY 11-6" DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 FACE OF CURB PREMOLDED JOINT FILLER 3/8" . za%o E FULL-DEPTH EXPANSION JOINT FACE OF ADJACENT CURB CUTTER SURFACE DEPRESSED CURB DETAIL TOP OF ROADWAY CEMENT CONCRETE TRAFFIC CURB AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: I. 2. 3. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler. For Depræsed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2 STD. PLAN - 101 PUBLIC WORKS CEMENT CONCRETE CURBS DEPARTMENT Images/102officialsigned.tif 6" SIDEWALK 1.5% 1• (IN) R. ALL CUT SLOPES BRIDGE OR PEDESTRIAN RAILING RAISED EDGE DETAIL EXTEND SIDEWALK TRANSVERSE JOINTS TO INCLUDE RAISED EDGE SIDEWALK 1,'2- (IN) R. cryp.) 1.5% ADJACENT TO CURB SIDEWALK 1/2" (IN) R. (TYP.) 1.5% 3'8• (IN) PREMOLDED JOINT FILLER ROU DING 2.0% UYP.) MIN. 2.0% SEE RAISED EDG DETAIL - THIS SHE FOR CURB DETAILS SEE STD PLAN 101 ROU DING MIN 2.0% FOR CURB DETAILS SEE STD PLAN 101. BARRIER - SEE CONT RACT PLANS FLUSH VERTICAL WALL - SEE DETAIL TYPICAL UNDER SIDEWALK WITH RAISED EDGE SIDEWALK 1/2' (IN) R. (TYR) 1.5% ADJACENT TO CURB (STEEP FILL SLOPES) ALL OR BARRIER SIDEWALK ADJACENT TO CURB AND RAILING OR WALL FOR SIDE TREATMENT SIDEWALK SECTIONS SIDEWALK 1.5% BUFFER STRIP (SEE NOTE 10) (TYP.) 1.5% MIN. FINISHED GRADE (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING - FLUSH IF PAVED ADJACENT TO BUFFER STRIP (IN) PREMOLDED JOINT FILLER SIDEWALK ADJACENT TO WALL DETAIL FOR CURB DETAILS SEE STD PLAN 101 (f) (IN) PREMOLDED JOINT FILLER TYPICAL WHERE APPLICABLE FOR CURB DETAILS SEE STD PLAN 101 STING ROADWAY CRUSHED RCM CRUSHED SURFACING TOP COURSE (CSTC) OMPACT TO 957. MODIFIED PROCTOR (UNLESS REQUIREMENT WANED BY ENGINEER) TYPICAL UNDER ALL CURB, GUTTER & SIDEWALK. CSTC UNDER CURB & GUTTER TO BE 6- THICKNESS OR MATCH EXISTING ROADWAY CRUSHED ROCK BASE. WHICHEVER IS GREATER (TYP. FOR ALL CURB & GUTTER). FINISHED GRADE 1' (IN) BELOW TOP OF CONCRETE SURFACE FOR CURB DETAILS SEE STD PLAN 101 BROOMED FINISH OR MATCH EXISTING 4" WIDE. TROWELED PERIMETER CEMENT CONCRETE CURB (CURB AND GUTTER SHOWN) FOR CURB DETAILS SEE STD PLAN 101. 1/8' TO 1/4- NOTES I. Four feet of the sidewalk width shall be the minimum pedestrian route (PAR) free of vertical and horizontal obstructions. Gratings, Access Covers, Junction Boxes, Cable Vaults, Pull Boxes and other appurtenanæs within the sidewalk must be flush with and match grade of the sidewalk. 2. Monolithic Cement Concrete Curb and Sidewalk is not permitted in new construction. When replacement work necessitates a Monolithic Cement Concrete Curb build per WSDOT Standard Plan FOO. 10-03. 3. Concrete to be PSL PUBLIC WORKS DEPARTMENT CONTRACTION JOINT IN SIDEWALK Ot•JLY FULL-DEPTH EXPANSION JOINT IN BOTH CURB AND SIDEWALK (SEE STD 101.1) JOINT AND FINISH DETAIL PREMOLOE JOINT FILLER E FULL-DEPTH EXPANSION JOINT c CONTRACTION JOINT For other referenced NOTES see STD PLAN 104.2. Paved surfaces must comply with STD PLAN 102.1 as applicable. STD. PIAN — 102 CEMENT CONCRETE SIDEWALK Images/104.2.tif CEM@tr CONCRETE SIDEWALK NOTES \ CEMENT CONCRETE CURB (SEE NOTE 3) DERESSED MONOUTH(C CIRB a (SEE THS SHEED TYPE C2B - ISOMETRIC VIEW (COMMERCIAL, WITH BUFFER) FACE OF CURB 2. 3, 4. 5, 6. 7. 8. 9, 10. When a driveway width exceeds 15 feet, Ønsfruct a full depth expansion Joint with 318m Jolnt filler elong the driveway lane Ilnes (see std. plan 102). expansion parallel with the as required at 15' rnaxlmum spacing when driveway wtdths exceed 30'. See std. plan 102 for sldewalk details, Curt and guüer shown, other curb designs may be specified, See std. plan 101 for curb details. Not The englneer design all driveways to Include elevatlons at all matted with symbol All elevations are at {he back of curb top on uphill side. Not For Dtiveway Widths DRIVEWAY STANDARDS (See NOTE 10). The expangion Ärds (see std. plan 102) shall be spaced as shown In the IgomotrE view. Stopes shall comply with sections R303.2,1 or R3032,2 or R3032.3 of the Reviged Guidelines for Public Rights-of-Way of Novanber 23, 2005 (PROWAG). Curb returns for any Type C-MAX Driveway may be on a STREET STANDARDS - Renton Municipal code (RMC) Title IV Development R+latlons CHAPTER 6 STREET AND UTILITY STANDARDS Section 4-6060 STREET STANDARDS DRIVEWAY STANDARDS = Renton Municipal Code (RMC) Title IV Development Regulations CHAPTER 4 CffY-WlDE PROPERTY DEVELOPMENT STANDARDS Section 44080 PARKING, LOADING AND DRIVEWAY REGULATIONS BEE (D CONTR.ACTION STD PLAN 102 l'-ffl NOTE: DNVEWAYLOFGITUDINN- OINT8 Stun.l- BE FULL DEPRE88ED CURB DETAIL ON THB SHEET TOP OF /- ROADWAY DEPRESSED MONOLTTHIC CURB GUTTER DETAIL OF ADJACENT SURFACE DEPRESSED CURB DETAIL AT RESIDENTIAL COMMERCIAL DRIVEWAYS, A-LEYS Driveway Example: TYPE CIB R=Reeldenüal, NurnkEr of Lanse (MAX=4 Lano Cortunerda() BEBuffer (Purding Strip). Bufe• PUBLIC WORKS DEPARTMENT CEMENT CONCRETE DRIVEWAY ENTRANCES NOTES AND DETAILS srm PLAN 1042 PROV D: ATE Images/104.3.tif MIN. (SEE NOTE B) 10 LF OF PAVED DRIVEWAY REQUIRED 3'8• EXPANSION JOINT (TYPO (SEE STD. PLAN RAMP WITH 12H tv SLOPE (TYP.) 3,a• CONTRACTION JOINT (TYP (SEE STD. PLAN 102} DIFFERENCE IN SLOPE MAX o DRIVEWAY RELATIVE NEGATIVE SLOPE (SLOP SHOWN EXAGGERATED) CEMENT CONCRETE SIDEWALK o PUBLIC WORKS DEPARTMENT & NTO CCN BID ITEM (INCLUDES SIDEWALK RAMPS) VARIES (SEE NOTE 7 SEE NOTE 5 TRUCTION JOINT SEE NOTE 1 PLAN VIEW 6 MIN. (SEE NOTE B) CEMENT CONCRETE CURB & GUTTER {SEE NOTE 3) CEMENT CONCRETE SIDEWALK 8 34. B.fAX. SEE NOTE 8 DEPRESSED CURB a GUTTER MIN CEMENT CONCRETE SIDEWALK DRIVEWAY W VARIES (SEE NOTE 10) 6• MIN SECTION A MIN 3,e• EXPANSION JOINT (TYP ISEE STD. PLAN 102) R (Typo SLOPE (SLOPE SHOWN EXAGGERATED) DRIVEWAY SE CEMENT CONCRETE CURB & GUTTER (SEE NOTE 3) DEPRESS MONOLiTHiC CURB OTTER ETAIL. STD PLAN 104.2) TYPE RIB - ISOMETRIC VIEW (RESIDENTIAL, WITH BUFFER) CEMENT CONCRETE DRIVEWAY ENTRANCE - TYPE RIB (SEE NOTE 3) SIDEWALK MOTH 6- MIN. ON For NOTES STD. PLAN 104.2 STD. PLAN - 104.3 PPR VED: ATE Gregg Zimmerman, Public Works Administrator Images/134officialsigned GROUND MOUNTED STREET NAME SIGNS.pdf Images/135officialsigned CONSTRUCTION NOTES.pdf Images/ADARAMP Cornerf40.15-03_e.tif NOTES CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS GRADE BREAK SEE CONTRACT PLANS LANDING CURB RAMP CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS GRADE BREAK GRADE BREAK SEE CONTRACT PLANS - 4 - 0" MIN. CEMENT CONCRETE SIDEWALK- SEE NOTE 5 FLARE (IYP.) 318" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F.30.10 GRADE BREAK CURB. OR CURB AND GUTTER SEE NOTE 4 FACE OF CURB MEASURED PARALLEL TO CURB (TYP.) z LANDING AND GUTTER - SEE NOTE 4 CEMENT CONCRETE SIDEWALK - SEE NOTE 5 PROVIDE SMOOTH TRANSITION TO SIDEWALK WDTH MIN. CURB RAMP GRADE BREAK SEE CONTRACT PLANS - 318" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 TRANSITION TO SIDEWALK BUFFER, IF PRESENT, OR TO BACK OF CURB (IMP.) SEE CONTRACT PLANS CURB, OR CURB AND GUTTER - SEE CONTRACT PLANS - 4' - 0" MIN. BUFFER WIDTH - MATCH TO CURB RAMP DEPTH (TYP.) CEMENT CONCRETE PEDESTRIAN CURB - SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F-45.10 DEPRESSED CURB AND GUTTER - SEE NOTE 4 SEE NOTE 4 FACE OF CURB DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.45.10 DEPRESSED CURB AND GUTTER 1. 2. 3. 4. 5. 6. 7. 8. 9. CROSSWALK PLAN VIEW CROSSWALK PLAN VIEW TYPE PERPENDICULAR B (SHOm WITH BUFFER) At marked crosswalks, the connection between the curb ramp and the road- way must be contained within the width of the crosswalk markings. Wiere "GRADE BREAK' is called out, the entire length of the grade break between the two adjacent surface planes shall be flush. Do not place Gratings, Junction Boxes, Covers, or other appurÉn- ances on any pan of the Curb Ramp or Landing, or in front of the Curb Ramp where it connects to the roadway. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Guter, Depressed Curb and Guter, and Pedestrian Curb See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and plaæment of sidewalk. The Bid Item "Cement Concrete Curb Ramp Type " does not include the adjacent Curb, Curb and Guter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. The Curb Ramp length is not required to exceed 15 feet (unless shown otherwise in the Contract Plans). When applying the 15-foot max. length, the running slope of the Curb Ramp is allowed to exæed 8.3%. use a single slope from bottom of ramp to top of ramp to match into the landing over a horizontal distance of 15 feet. Do not include the abutting landing in the 15-foot max. measurement. Curb Ramps and Landings shall receive a broom finish. See Standard Specifications 8-14. Pedestrian Curb may be omitted if the ground surfrce at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to retain. CONTRACTION JOINT ayp.) - SEE STANDARD PLAN F.30.10 FOR CURB RAMP LENGTHS GREATER THAN 8' - 0" PROVIDE CONTRACTION JOINT EQUALLY SPACED 4' - 0" MIN. OC. TYPE PERPENDICULAR A LEGEND SEE CONTRACT PLANS DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.46.10 15 - 0" MAX. (TYP.) SEE NOTE 7 GRADE BREAK SLOPE TREATMENT - SEE STANDARD PLAN F.30.10 LANDING CEMENT CONCRETE PEDESTRIAN CURB - SEE NOTE 4 GRADE BREAK COUNTER SLOPE - 5.0% MAX. TOP OF ROADWAY DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F.10.12 CEMENT CONCRETE CURB RAMP "TYPE PERPENDICULAR "B" PAY LIMIT - SEE NOTE 6 SLOPE IN EITHER DIRECTION 1.5 OR FLATTER RECOMMENDED FOR DESIGWFORMWORK MAX.) 7.5% OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (8.3% MM.) 9.5% OR FLATTER RECOMMENDED FOR DESIGWFORWJORK (10% MAX.) CURB RAMP SECTION A CEMENT CONCRETE CURB RAMP "TYPE PERPENDICULAR "A" PAY LIMIT - SEE NOTE 6 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F45.10 DEPRESSED CURB AND GUTTER - SEE NOTE 4 CEMENT CONCRETE CURB CURB RADIUS DETAIL ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT zeller, Jun 24 2016 7:20 AM PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpcntcr, .lcff eazÉuztez 'ed Jun 29 2016 2:28 PM COSI STATE DESIGN ENGINEER Washington State Deprtment of Tmr•portation Images/ADARAMP f40.16-03_e.tif NOTES MATCH SIDEWALK WIDTH - 4' 0" MIN. - SEE CONTRACT PLANS 318" (IN) EXPANSION JOINT - SEE STANDAR PLAN F.30.10 SIDEWALK - SEE NOTE 6 BUFFER STRIP - SEE CONTRACT PLANS PEDESTRIAN CROSSING CLOSURE SIGN z GRADE BREAK SIDEWALK - SEE NOTE 6 PEDESTRIAN CURB - SEE NOTE 10 (TYP.) c LANDING PEDESTRIAN CURB SEE NOTE 10 MATCH SIDEWALK WIDTH 4' 0" MIN. SEE CONTRACT PLANS 318" (IN) EXPANSION JOINT - SEE STANDARD PLAN F.30.10 O SIDEWALK o SEE NOTE 6 MATCH SIDEWALK WDTH - 4' 0" MIN. SEE CONTRACT PLANS CURB RAMP LANDING DETECTABLE WARNING SURFACE BUFFER SEE STANDARD PLAN F45.10 STRIP PEDESTRIAN CROSSING CLOSURE SIGN BUFFER STRIP PEDESTRIAN CURB - SEE NOTE 10 o DETECTABLE WARNING SURFACE c SEE STANDARD PLAN F.45.10 CURB AND GUTTER - SEE NOTE 5 FACE OF CURB CURB AND GUTTER - SEE NOTE 5 CURB RAMP PLAN VIEW FACE OF CURB CURB RAMP 15' - 0' MAX (TYP.) SEE NOTE 8 TYPE SINGLE DIRECTION A DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F.45.10 GRADE BREAK 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. GRADE BREAK LANDING 1 GRADE BREAK COUNTER SLOPE 5.0% MAX. TOP OF ROADWAY SIDEWALK - SEE NOTE 6 DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F.10.12 PLAN VIEW TYPE SINGLE DIRECTION B 15 - 0" MAX (TYP. SEE NOTE 8 GRADE BREAK CURB RAMP 15' - 0" MAX (TYP. SEE NOTE 8 LANDING GRADE BREAK SIDEWALK - SEE NOTE 6 CURB RAMP This plan is to be used where pedestrian crossing in one direction is not permitted. At marked crosswalks, the connection between the Landing and the roadway must be contained within the width of the crosswalk markings. Where "GRADE BREAK" is called out, the entire length of the grade break between the two adjacent sufface planes shall be flush. Do not place Gratings, Junction Boxes, Access Covers, or other appurten- ances on any part of the Curb Ramp or Landing or in the Depressed Curb and Gutter where the Landing connects to the roadway. See Contract Plans for the curb design specified. See Standard Plan F-10.12 for Curb, Curb and Gutter, Depressed Curb, Gutter and Pedestrian Curb See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See Contract Plans for width and plaæment of sidewalk. The Bid Item "Cement Concrete Curb Ramp Type " does not include the adjacent Curb, Curb and Guter, Depressed Curb and Gutter, Pedestrian Curb, or Sidewalks. The Curb Ramp length is not required to exceed 15 feet (unless shown otherwise in the Contract Plans). Men applying the 15-foot max. length (measured from back of sidewalk) the running slope of the curb ramp is allowed to exæed 8.3%. Use a single constant slope from botom of ramp to top of ramp to match into the sidewalk over a horizontal distance of 15 feet. Curb Ramps and Landings shall reEve a broom finish. See Standard Specifications 8-14. Pedestrian Curb may be omitted if the ground surfaæ at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to LEGEND SLOPE IN EITHER DIRECTION 1.5 OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (2% MAX.) 7.5% OR FLATTER RECOMMENDED FOR DESIGWFORMWORK (8.3% MAX.) SEE NOTE 7 CURB RAMP SECTION CONTRACTION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 FOR CURB RAMP LENGTHS GREATER THAN - 0" PROVIDE CONTRACTION JOINT EQUALLY SPACED 4' - 0" MIN. OC. 1 SECTION B (ALONG INSIDE RADIUS AT BACK OF WALKWAY) "CEMENT CONCRETE CURB RAMP TYPE SINGLE DIRECTION B" PAY LIMIT - SEE NOTE 7 "CEMENT CONCRETE CURB RAMP TYPE SINGLE DIRECTION A" PAY LIMIT - SEE NOTE 7 1" (IN) RADIUS CORNER PEDESTRIAN CURB 90' ANGLE RADIUS MAY VARY ISOMETRIC VIEW TYPE SINGLE DIRECTION A PAY LIMIT DETECTABLE WARNING SURFACE SEE STANDARD PLAN F46.10 DEPRESSED CURB AND GUTTER SEE NOTE 5 DETAIL c ISOMETRIC VIEW TYPE SINGLE DIRECTION B PAY LIMIT Zeller, Scott Jun 24 2016 7:21 AM SINGLE DIRECTION CURB RAMP STANDARD PLAN F-40.16-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpenter, JelT ewvP"tet, 'e" 29 20162 29 PM STATE DESIGN ENGINEER Washington State Deprtment of Tmr•portation Images/COR STD PLAN 129.STEEL SIGN SUPPORT.pdf Images/f45_10-02_e.tif NOTES c TRUNCATED DOME SECTION A SEE STANDARD SPECIFICATIONS FOR COLOR OF SURFACE TRUNCATED DOME DETAILS C E MIN. 0.65" 0.45" 0.2" MAX. 2.40" 0.90" 1.40" 0.2" CURB RAMP, LANDING, CUT- THROUGH OR WALKWAY BACK OF CURB SEE NOTE 2 CURB AND GUTTER DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 IMP. OF ALL 1. 2. TRUNCATED DOME SPACING SEE NOTE 3 CURB RAMP WALKWAY APPLICATIONS 3. 4. MATCH TO WIDTH OF CURB RAMP LANDING, CUT-THROUGH OR WALKWAY DETECTABLE WARNING SURFACE DETAIL LANDING OFFSET SEE NOTE 8 5. 6. 7. 8. WIDTH OF WALKWAY DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 4 BACK OF CURB WALKWAY LANDING FLARE The Detectable Warning Surface (DWS) shall extend the full width of the curb ramp, landing, or other roadway entrance as applicable. Exception: If the Manufacturer of the DWS requires a concrete border around the DWS, a variance of up to 2 inches on each side of the DWS is permitted. The Detectable Warning Surface (DWS) shall be placed at the back of curb, with the Wvo leading corners of the DWS panel placed adjacent to the back of the curb, and with no more than a 2 inch gap between the DWS and the back of the curb measured at the center of the DWS panel. Exception: If the Manufacturer of the selected DWS requires a concrete border around the DWS, a variance of up to 2 inches from the back of the curb is permitted (measured at the leading corners of the DWS panel). The rows of truncated domes shall be aligned to be perpendicular to the grade break at the back of curb. The rows of truncated domes shall be aligned to be parallel to the direction of travel. If curb and gutter are not present, such as a shared-use path connection, the Detectable Warning Surface shall be placed at the pavement edge. See Standard Plans for sidewalk and curb ramp details. If a curb ramp is required, the location of the Detectable Warning Surface must be at the bottom of the ramp and within the required distance from the rail. When the grade break between the curb ramp and the landing is less than or equal to 5 ft. from the back of curb at all points, place the Detectable Warning Surface on the bottom of the curb ramp directly above the grade break. WIDTH OF CUT-THROUGH z z WALKWAY CURB RAMP FLARE DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 3 WIDTH OF CURB RAMP OF CUT- THROUGH (TY".) MIN. SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING 5 FT. FROM BACK OF CURB) (SEE NOTE 6) LANDING CURB RAMP BACK OF CURB - SEE NOTE 2 DIRECTION OF TRAVEL WALKWAY WIDTH OF WALKWAY PERPENDICULAR CURB RAMP (SEE NOTE 6) OF CURB RAMP, LANDING, OR WALKWAY DETECTABLE WARNING SURFACE (TY".) SEE NOTE 3 DETECTABLE WARNING SURFACE (DWS) - SEE NOTE 3 DETECTABLE WARNING SURFACE (DWS) - SEE NOTES 4 & 7 DETECTABLE WARNING SURFACE (TYP.) - SEE NOTE 3 BACK OF CURB - SEE NOTE 2 ISLAND CUT-THROUGH BACK OF CURB - SEE NOTE 2 (TYP.) BACK OF CURB - SEE NOTE 2 • a a • •a aaa• MEDIAN CUT-THROUGH BACK OF CURB SEE NOTE 2 SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING > 5 FT. FROM BACK OF CURB) CURB RAMP WALKWAY BACK OF CURB - SEE NOTE 2 (SEE NOTE 6) LANDING WIDTH OF LANDING CURB RAMP WALKWAY DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 WIDTH OF SHARED- USE PATH OR WALKWAY (TY".) WIDTH OF CUT-THROUGH (TYP.) PAVEMENT EDGE SHARED-USE PATH OR WALKWAY SHOULDER RAIL PATH OR WALKWAY PEDESTRIAN RAILROAD CROSSING ROUNDABOUT SPLITTER ISLAND DETECTABLE WARNING SURFACE (DWS) - SEE NOTES 4 & 5 PLACEMENT GUIDELINES SHARED-USE PATH CONNECTION Zeller, Scott Jul 12 2016 4:25 PM DETECTABLE WARNING SURFACE STANDARD PLAN F-45.10-02 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpenter, Jeff Jul 15 2016 2:26 PM STATE DESIGN ENGINEER Washington State Department of Transportation PARALLEL CURB RAMP (SEE NOTE 6) PlotCfgs/NDRS-MONO-F.ctb PlotCfgs/PDF Complete_2017 22x34.pc3 Textures/Concrete.Cast-In-Place.Flat.Grey.1.jpg Textures/Sitework.Planting.Grass.Short.jpg Textures/Sitework.Planting.Grass.Thick.jpg Textures/Sitework.Planting.Gravel.Crushed.jpg Textures/Sitework.Planting.Gravel.Mixed.jpg Textures/Sitework.Planting.Soil.jpg