Loading...
HomeMy WebLinkAboutMFP20003106.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP20003106 IVR Number: 20003106 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:07/20/2020Application Date:7841800090Parcel Number: 215 WHITWORTH AVE S Permit Type:08/06/2020Issue Date:Franchise Permit Work Class:08/06/2021Expiration Date:Major Utility Job Number: 109128591Franchise Type:Natural Gas Description: REVISION: SEE ATTACHED SHEET FOR REVISION ON BURNETT AVE S. PSE gas 32' offset relocate to avoid future storm at intersection of S 4th St and Shattuck Ave S. 134' offset relocate to avoid future water on Whitworth Ave S (north of S 3rd St). Cut and cap main to avoid future storm at Mill Ave S and S 2nd St Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX INFRASOURCE SVCS B: (206) 949-5846Contractor Business License Number: 36742Construction Contractor: INFRASL871C2 Marita Bond Puget Sound Energy - Billing 6905 S 228th St Kent, WA 98032 B: (253) 395-6346Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES S 3RD PL S 4TH ST131120 19 12 11 18 1212231111 SHATTUCK AVE SSHATTUCK AVE S1515 WHITWORTH AVE SSTOP FLAGGER STOP FLAGGER STOP FLAGGERRIGHTKEEPR4-7BM6-2M6-2ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'W20-7ABEPREPAREDTOSTOPW3-4100'100'W20-7ABEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1RIGHTSHOULDERCLOSEDW21-5aRW1-4L100'100'100' ROADWORKAHEAD W20-1BE PREPARED TO STOP W3-4100'100'W20-7ABEPREPAREDTO STOP W3-4100'100'ROADWORK AHEAD W20-1RIGHT LANECLOSEDAHEAD W20-5RW1-4L100'100'100'ROADWORKAHEADW20-1W1-4R100'100'RIGHT KEEP R4-7B R9-3C/WCLOSEDDETOURM4-9bR9-3C/W CLOSED DETOUR M4-9bDETOURM4-9bDETOURM4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN WORK PIT 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 15' SCL of S 4th St & 17-37' ECL of Shattuck Ave S, and 18' SCL of S 4th St & 17-37' ECL of Shattuck Ave S. N PSE PUGETSOUNDENERGY JOB#109128591 215 Whitworth Ave S, Renton, WA 98057 8/6/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 1 of 5 PRINT ON 11X17" SHEETS ONLY 215 Whitworth Ave S Renton WA 98057 USA 1818 151513141111ONE WAY ONE WAY 1818 S 3RD ST S 3RD STWHITWORTH AVE SWHITWORTH AVE SS 2ND ST S 2ND ST 1314STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROAD WORKAHEAD W20-1W20-4ONE LANEROADAHEAD 100'100'100'22222222ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1 100' ONE WAY ONE WAY PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888 -9999 INFRASOURCE LLC 000 00000 00 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN WORK PIT 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109128591 215 Whitworth Ave S, Renton, WA 98057 8/6/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 2 of 5 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 378' NCL of S 3rd St & 6-8-17' WCL of Whitworth Ave S, and 268' NCL of S 3rd St & 9' WCL of Whitworth Ave S. N PRINT ON 11X17" SHEETS ONLY 215 Whitworth Ave S Renton WA 98057 USA 1818 151513141111ONE WAY ONE WAY 1818 S 3RD ST S 3RD STWHITWORTH AVE SWHITWORTH AVE SS 2ND ST S 2ND ST 1314STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'22222222ROADWORKAHEADW20-1 100'ROADWORKAHEADW20-1 100' ONE WAY ONE WAY BEPREPAREDTOSTOPW3-4BEPREPAREDTOSTOPW3-4 100' 100' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 00 0 000 0000 NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN WORK PIT 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 268-378' NCL of S 3rd St & 5' ECL of Whitworth Ave S. N PSE PUGETSOUNDENERGY JOB#109128591 215 Whitworth Ave S, Renton, WA 98057 8/6/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 3 of 5 PRINT ON 11X17" SHEETS ONLY 12 1212 ONE WAYS 2ND ST BRON S O N W A Y N MAIN AVE SBRON S O N W A Y N 1919S 2ND ST 111112 12 1111 BUSSTOPMILL AVE SMILL AVE SRIGHTKEEPR4-7BRIGHT KEEP R4-7B STOP FLAGGER 1 1 1 1 1 1 1 2 1 1 22 RIGHT KEEP R4-7B STOP FLAGGER STOP FLAGGER ROAD WORK AHEAD W20-1LEFT LANECLOSEDAHEAD W20-5L100'100'W20-7ABEPREPAREDTO STOP W3-4100'100'W20-7A W20-1ROAD WORK AHEAD W20-4ONE LANEROADAHEAD100'100'ROADWORKAHEADW20-1W20-7A100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'R O A DWO R K A H E A D W20-1 B E P R E P A R E D T OS T O P W3-4100'100'R9-3C/WCLOSEDDETOURM4-9b R9-3C/WCLOSEDDETOURM4-9bDETOURM4-9b DETOURM4-9bSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN WORK PIT 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 3' NCL of S 2nd St & 17' WCL of Mill Ave S. N PSE PUGETSOUNDENERGY JOB#109128591 Mill Ave S & S 2nd St, Renton, WA 98057 8/6/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 4 of 5 PRINT ON 11X17" SHEETS ONLY 111111113RD STBURNETT AVE S BURNETT AVE S ALLEYONLYONLY1212122222ONE WAYONE WAYONE WAYONE WAYONE WAY151510LOGAN AVE SSMITHERS AVE S RIGHTKEEPR4-7BPOLICEUPOM6-2W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'W1-4R 100'1414W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RW1-4L100'100'100'R9-3 C/WCLOSEDR9-3C/WCLOSEDDETOURM4-9bDETOURM4-9b DETOURM4-9b DETOURM4-9b DETOURM4-9bDETOURM4-9bLEAVE 5' MIN FOR PEDESTRIAN.Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLAN28" TRAFFIC CONELEGENDWORK PITTRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040NNotes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be 19' SCL of S 3rd St & 37' WCL ofBurnett Ave S, to 30' SCL of S 3rd St & 16' WCL ofBurnett Ave S.PSEPUGETSOUNDENERGYJOB#1091285913rd St & Burnett Ave S, Renton, WA 980578/6/2020safaa.alneema@pse.com(425) 398-6077SHEET 5 of 5PRINT ON11X17" SHEETS ONLY G0+00 G1+00G2+00G3+00G4+00G5+00G6+00J4+00J5+00J6+00J6+80 C23+00 C24+00 C25+00 C26+00C26+15 F11+00 F12+00F13+00F11+00F12+00F13+00SHATTUCK AVE S440S 4TH ST IP GAS FLOWIP GAS FLOWIP GAS FLOW N Vicinity Map Owner / Developer Contact Info officeATTN: PSE N/A N/A PSE N/A Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS PROJECT PHASE Notification #Order # SVC Retirement Relocate SAP Superior Service/Meter Service/Meter Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter SYSTEM MAOP DENOTED BY: SYSTEM MAOP = ___ PSIG BOX (TEST LEAD) INSTALLATION. THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. PURGE POINTS AND PRESSURE TAPS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3300, AND 2525.1200. ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO STANDARD GAS CONSTRUCTION NOTES: 14. 13. 15. 10. 11. THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 9. 6. 7. 5. 4. 3. 1. 45 16. IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ----------------- NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS).2. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED.12. ___________________________, PHONE______________. NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES17. FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD)109128591THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON HOLE HOG TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BP8 END BP9 START BP10 END BP11 START BP12 END BP13 START BP14 END BP15 START BP16 END BP17 START BP18 END BP19 START BP20 END (____') PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PROJECT MANAGER TO MAKE EGOR RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300, 2525.3400 REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARDS 2525.2100 FOR INSERTIONS AND 2525.3600 FOR STANDARDS 2525.2100 AND 2525.3600. PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 11. 12. 14. 13. AND 2525.1200, AND PSE GAS FIELD PROCEDURE 4700.1500. PER PSE GAS OPERATING STANDARD 2550.1600. ABANDONMENT OR DEACTIVATION. 10. 9. 5. 6. 7. 8. GAS OPERATING STANDARD 2525.2300. 4. 1. 2. 3. OUTAGE. STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY:##### ROPE PROPOSED PIPE 2" MPE IP MAIN WORK AREA STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 60 IP058- 45 N/A 109128591 N/A 1"=30'1/3 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr SITE PLAN SCALE: NTS N/AMN Retirement RENTON 29 CSPSKGPI SE-18-23-05 208.080 209.081 N/A N/AN/A N/A 11536972 N/A 109128591 N/A S. ALNEEMA 253.234.6301 425.559.4647 SAP BATCH YEAR & FOOTAGE ACTUAL LENGTH OF RETIREMENT MATERIAL RETIRED ORIGINAL JOB ORIGINAL YEAR PROPOSED LENGTH OF RETIREMENT SIZE OF RETIRED MAIN 108619932 INSTALL 2"MPE 170' PUBLIC IMPROVEMENT DOWNTOWN UTILITY IMPROVEMENT 215 WHITWORTH AVE S RENTON 98057 16.ACTIVE SERVICES TO BE PARTIALLY REPLACED AND TEST & TIED DENOTED BY: 17.ACTIVE SERVICES TO BE TESTED & TIED DENOTED BY:##### ##### 425.559.4647 G. HELTON 425.559.4647 G. HELTON G. HELTON N/A N/A Service/Meter RETIRE 1 1/4"MPE 114' HOUS E R W A Y S S 2ND ST SHATTUCK AVE SS 2ND ST S 3RD ST S 4TH ST S 4TH ST S 3RD STWHITWORTH AVE SMORRIS AVE SSMITHERS AVE SBURNETT AVE SWILLIAMS AVE SWELLS AVE S MAIN AVE SBRO N S O N W A Y N PLOT PLAN A SEE THIS SHEET SEE SHEET 2 PLOT PLAN B PLOT PLAN D SEE SHEET 3 PLOT PLAN A SCALE: 1" = 30'-0" 1 1 Scale: NTS TIE IN DETAIL1 1 CUT & CAP CAP 2" MPE 18'S C/L & 35'E C/L ____'S C/L & ____'E C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN ELBOW 2"X90° MPE 15'S C/L & 37'E C/L ___'S C/L & ___'E C/L TIE IN TEE HV 2"X2" MPE 18'S C/L & 37'E C/L ____'S C/L & ____'E C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'S C/L & ____'E C/L CUT & CAP CAP 2" MPE 18'S C/L & 19'E C/L ____'S C/L & ____'E C/L ELBOW 2"X90° MPE 15'S C/L & 17'E C/L ___'S C/L & ___'E C/L TIE IN TEE HV 2"X2" MPE 18'S C/L & 17'E C/L ____'S C/L & ____'E C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'S C/L & ____'E C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 4.5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3', AT 15'S C/L & 27'E C/L (____')(____')2"STW 94'RETIRE 2"MPE 16'RETIRE SEE SHEET 3 PLOT PLAN C 4"STW 88'RETIRE INSTALL 4"STW 154' CRPL #2 5 1 . 5 " S T L CRPL#1 66" S T L G1+00G2+00G3+00G4+00G5+00G6+00G6+00C16+00 C17+008" C900 SS24" C900 SS 24" C900 SS8" C900 SSC16+00 C17+0012"DI WG1+00G2+00G3+00G4+00G5+00G6+0012"DI WWHITWORTH AVE S321IP GAS FLOW316322400220S 3RD ST IP GAS FLOW IP GAS FLOW IP GAS FLOWIP GAS FLOWG1+00G2+00G3+00G4+00G5+00G6+00IP GAS FLOWIP GAS FLOWIP GAS FLOW10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 G-0+20 G0+00 G0+20 G0+40 G0+60 G0+80 G1+00 G1+20 G1+40 G1+60 G1+80 G2+00 G2+20 G2+40 G2+60 G2+80 G3+00 G3+20 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON N/A PUBLIC IMPROVEMENT N/A 1"=30'2/3 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 PLOT PLAN B SCALE: 1" = 30'-0" 1 2 Scale: NTS TIE IN DETAIL1 2 425.559.4647 G. HELTON 425.559.4647 G. HELTON 109128591 RENTON 29 CSPSKGPI SE-18-23-05 208.080 209.081 DOWNTOWN UTILITY IMPROVEMENT 215 WHITWORTH AVE S RENTON 98057 TEE TAP 1 1/4"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L TEE TAP 1 1/4"X1 1/8" MPE (BYPASS TEE) ____'N C/L & ____'W C/L PIPE 1-1/8" MPE BYPASS TEE TAP 1 1/4"X1 1/8" MPE (BYPASS TEE) ____'N C/L & ____'W C/L TEE TAP 1 1/4"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L CUT & CAP CAP 1 1/4" MPE 270'N C/L & 9'W C/L ____'N C/L & ____'W C/L TIE IN TEE 2"X2" INLINE TEE 268'N C/L & 5'E C/L ___'N C/L & ___'E C/L PROPOSED PIPE 2" MPE IP MAIN 5'E C/L, ____'E C/L TEE TAP 1 1/4"X1 1/8" MPE (BYPASS TEE) ____'N C/L & ____'W C/L TEE TAP 1 1/4"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L TEE TAP 1 1/4"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L TEE TAP 1 1/4"X1 1/8" MPE (BYPASS TEE) ____'N C/L & ____'W C/L PIPE 1-1/8" MPE BYPASS 2" WI CASING DEACTIVATE IN PLACE EXISTING 1 1/4" MPE IP MAIN 2 2 CUT & CAP CAP 1 1/4" MPE 376'N C/L & 17'W C/L ____'N C/L & ____'W C/L ELBOW 1 1/4"X90° MPE (SQUEEZE & FUSE TIE IN) 378'N C/L & 17'W C/L ___'N C/L & ___'W C/L TIE IN TEE 2"X2" INLINE TEE 378'N C/L & 5'E C/L ___'N C/L & ___'E C/L (____')(____')(____') Scale: NTS TIE IN DETAIL2 2 2" WI CASING DEACTIVATE IN PLACE EXISTING 1 1/4" MPE IP MAIN ELBOW 1 1/4"X90° MPE (SQUEEZE & FUSE TIE IN) 268'N C/L & 9'W C/L ___'N C/L & ___'W C/L PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE WATER PIPE AT 4' 378'N C/L& 8'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 4' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 2.5' 298'N C/L& 5'E C/L FUSE TIE IN REDUCER 2"X1 1/4" MPE 268'N C/L & 9'W C/L ___'N C/L & ___'W C/L FUSE TIE IN REDUCER 2"X1 1/4" MPE 378'N C/L & 17'W C/L ___'N C/L & ___'W C/L PROPOSED PIPE 2" MPE IP MAIN 268'N C/L, ____'N C/L PROFILE SCALE: 1" = 30'-0" HORIZ , 2" = 15'-0" VERT PROPOSED PIPE 2" MPE IP MAIN EXISTING 1 1/4" MPE IP MAIN EXISTING 1 1/4" MPE IP MAIN CRPL #2 51.5" STLCRPL #2 66" STL EXIST 12"WPROP 12"DI W BYPASS REVIEW: DETAIL 1/1 & DETAIL 2/2: THE EX. 1-1/4” PE MAIN (832-380)IS 1 WAY FEED IN WHITWORTH AVE S. THE SEGMENT OF THE EXISTING 1-1/4” PE MAIN (832-380) ON WHITWORTH AVE S CANNOT BE TAKEN OUT OF SERVICE WITHOUT INSTALLING A BY-PASS. 1-1/8” BYPASS IS REQUIRED. GAUGE BOTH SIDES OF THE SQUEEZE PER PSE STANDARDS ON THE EX.1-1/4” PE MAIN (832-380) ON WHITWORTH AVE S. IF THE PRESSURES DO NOT STABILIZE AT #37, RELEASE THE SQUEEZE AND CALL GSI-SP FOR FURTHER INSTRUCTIONS. GORDANA VUKOSAV GAS SYSTEM PLANNING 425-241-5740 EXISTING GRADE CRPL #3 66" S T L CRPL #2 51.5" S T L J6+00J6+80C24+00 C25+00 C26+00 C26+1524" C900 SS C24+00 C25+00 C26+00 C26+15 IP GAS FLOW IP GAS FLOWBURNETT AVE S3RD ST J6+00J6+80C24+00 C25+00 C26+00 C26+15 CRPL#3 66 " S T L CPPL#3 66" STL L3+00 L4+00L5+00284 LF 12" CIPP SS12" C900 SS K4+20 K3+00 K4+008" SDR 35 SS12" CIPP SSC900 K3+00 K4+00L3+00 L4+00L5+0012"DI WS 2ND STMILL AVE SIP GAS FLOW IP GAS FLOWIP GAS FLOWIP GAS FLOWIP GAS FLOW IP GAS FLOWTHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON N/A PUBLIC IMPROVEMENT N/A 1"=30'3/3 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 425.559.4647 G. HELTON 425.559.4647 G. HELTON 109128591 RENTON 29 CSPSKGPI SE-18-23-05 208.080 209.081 DOWNTOWN UTILITY IMPROVEMENT 215 WHITWORTH AVE S RENTON 98057 PLOT PLAN C SCALE: 1" = 30'-0" CUT & CAP CAP 2" WELD 3'N C/L & 17'W C/L ____'N C/L & ____'W C/L DEACTIVATE IN PLACE EXISTING 2" STW IP MAIN TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'N C/L & ____'W C/L Scale: NTS TIE IN DETAIL1 3 1 3 TIE IN STOPPER 4"X150 B/O & ELBOW 4"X90° WELD 19'S C/L & 127'W C/L ____'S C/L & ____'W C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'S C/L & ____'W C/L CUT & CAP CAP 4" WELD 19'S C/L & 125'W C/L ____'S C/L & ____'W C/L EXISTING 4" CAP END OF MAIN 19'S C/L & 13'W C/L DEACTIVATE IN PLACE EXISTING 4" STW IP MAIN PLOT PLAN D SCALE: 1" = 30'-0" EXISTING SEWER MANHOLE SHOWN FOR REFERENCE 30'S C/L & 77'W C/L ____'S C/L & ____'W C/L CUT & CAP CAP 4" WELD 19'S C/L & 37'W C/L ____'S C/L & ____'W C/L TIE IN STOPPER 4"X150 B/O & ELBOW 4"X90° WELD 19'S C/L & 35'W C/L ____'S C/L & ____'W C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'S C/L & ____'W C/L ELBOW 4"X90° WELD 12'N C/L & 127'W C/L ___'N C/L & ___'W C/L ELBOW 4"X90° WELD 12'N C/L & 35'W C/L ___'N C/L & ___'W C/L PROPOSED PIPE 4" STW IP MAIN 12'N C/L, ____'N C/L (____')(____')(____')PROPOSED PIPE 4" STW IP MAIN TOP OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE SEWER PIPE AT 21' 3'N C/L& 127'W C/L 601312613617S 3RD STBURNETT AVE S2" PE IP 6'S 812-075DEACT 4" WI 9'S 73E079DEACT 6" CI 13'S 69E1254" STW IP 19'S 73E0792" STW IP 6'S UnknownDEACT 6" CI 9'S 69E1252" MPE IP 8'S 97159762" PE IP 5'W 812-075DEACT 4" WI 18'E W PL 73E0791 1/4" MPE19975/8" MPE20061 1/8" MPE20065/8" MPE200334TF72'ETF12'S7'S30'E43'E149'E37'E66'E2'W17'WTLTL15'ST6'S77'E,6'S17'W13'W,9'S46'E71'ET18'ST16'ST20'WSS17'S17'WIC4" CI C4" WI CasingLC#AEOC 10'S#A#B#D D2305E076, R2305E072NE, A2305E072S208080, Q209081The information on the attached maps is subject to change without notice. Puget Sound Energy makes no warranty, expressed or implied, concerningthe suitability of this information for any purpose. Recipient agrees to not disclose this confidential information to any other person or entity,unless authorized in writing by Puget Sound Energy. This map is not to be used for determining the actual location of any PSE facilities (call 811).“09-08-2020Scale 1:450Lat\Long=47.4795, -122.2086run main in alley tie in herec/c herec/c hereThe gas main is actually about heredeactivate this section completely