Loading...
HomeMy WebLinkAboutMFP20004127.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP20004127 IVR Number: 20004127 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:09/14/2020Application Date:7227801595Parcel Number: 2909 NE 16TH ST Permit Type:09/24/2020Issue Date:Franchise Permit Work Class:09/24/2021Expiration Date:Major Utility Job Number: 109129009Franchise Type:Natural Gas Description: PSE gas relocate 1223' of gas main to avoid conflicts with cities project. That is total relocation footage there are 5 separate locations. Replace svc stubs to 12 svc's. Pothole all existing utilities. Restoration per City of Renton standards Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX INFRASOURCE SVCS B: (206) 949-5846Contractor Business License Number: 36742Construction Contractor: INFRASL871C2 SAUVE WILLIAM RAYMOND 14626 SE 245TH CT KENT , WA 98042 Owner Marita Bond Puget Sound Energy - Billing 6905 S 228th St Kent, WA 98032 B: (253) 395-6346Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 1ϭ/Ϯϱ/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.܆ A copy of the Traffic Control Plan (TCP) Application form. 2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ܆ Include map(s) showing the location of the project and work area. ܆ Be legible lettering and clear, contrasting, symbols of viewing or printing. ܆ Must indicate street names, and north arrow and scale. ܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ܆ Types of plans required: ܆ Work hour plan – show all mobility impacts during construction hours. ܆ Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ܆ Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ܆ Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering MFP20004127 Scott Warlick CED 9/24/2020 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019 APPLICANT AGREES TO ALL THE FOLLOWING: x TCP must be approved prior to commencing the work, and all permit conditions shall be met. x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). x Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. x Approved Temporary TCP must be at the work site during work hours. x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. x Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date 2909 NE 16th St Renton WA 98056 USAJEFFERSON AVE NE NE 16TH STINDEX AVE NE151514141212HARRINGTON AVE NEINDEX AVE NE 16161515141418181717 NE 15TH STKIRKLAND AVE NENE 1 6TH STBUSSTOPBU S S TOP1616 HARRINGTON AVE NE161616161313 1313 NE 16TH ST 16 16 1212STOP FLAGGERSTOPFLAGGER STOPFLAGGERSIDEWALKCLOSEDR9-9SID E W A L K CL O S E DR9-9W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROA D WOR K AHEA D W20-1W20-4ONE L A N E ROAD AHEA D100'100'100'W20-1ROADWORKAHEADAHEAD USE OTHE R S I D E SIDEWALK C L O S E D AHEADUSE OTHER SIDESIDEWALK CLOSEDPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#1091290092909 NE 16TH ST, RENTON, WA 9805607/10/20JOHN.CROFOOT@PSE.COM425-424-6658SHEET 1 of 9Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be along NE 16th St from Index AveNE to Jevverson Ave NE. Then South along JeffersonAve NE until NE 12th St.NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604028" TRAFFIC CONEWORK PITTRAFFIC FLOWSIGN LOCATIONSTOPFLAGGERLEGENDCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYMFP20004127 2909 NE 16th St Renton WA 98056 USAJEFFERSON AVE NE NE 16TH ST151516161515141418181717 NE 15TH STKIRKLAND AVE NENE 1 6 TH STBUSSTOPB USS TOP1616 NE 16TH STSTOP FLAGGERSTOPFLAGGER STOP FLAGGER R9-3C/WCLOSEDR9-3C/WCLOSEDOTHER SIDES/W CLOSEDSIDEWALK CLOSEDR9-9AHEADUSE OTHER SIDESIDEWALK CLOSEDAHEAD USE O T H E R SI D E SIDEW A L K C L O S E DTHE CREW SHALL CEASEWORK FOR A FLAGGER/SPOTTERTO ESCORT PEDESTRIANSAROUND THE WORK AREAW20-7AROAD WORK AHEAD W20-1W20-4ONE LAN E ROAD AHEAD 100 '100'100' W20-1ROADWORKAHEAD W20-1ROADWORKAHEADPLACE SIGN ATHARRINGTON AVE NE1515 W20-7AROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'1515RESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'PLACE SIGNS ALONG WORK AREAFROM TO TOW AWAY AREA PHONE 888-9999 INFRASOURCE LLC 000 0000000 NO PARKING NO-PARK Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be along NE 16th St from Index AveNE to Jevverson Ave NE. Then South along JeffersonAve NE until NE 12th St.NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604028" TRAFFIC CONEWORK PITTRAFFIC FLOWSIGN LOCATIONSTOPFLAGGERLEGENDCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJOB#1091290092909 NE 16TH ST, RENTON, WA 9805607/10/20JOHN.CROFOOT@PSE.COM425-424-6658SHEET 2 of 9MFP20004127 2909 NE 16th St Renton WA 98056 USA JEFFERSON AVE NENE 1 6 T H S T 1515 16161 5 1 5 1414 1818 1717NE 15TH STKIRKLAND AVE NENE 16 T H S T BUSSTOPBUS STOP 16161 6 16STOP FLAGGER STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100' 100'100' W20- 7 AROADWORKAHEADW20- 1 W20- 4ONE LANEROADAHEAD100' 100' 100'W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'RECEIVING PITS RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA R K W20-1ROAD WORKAHEADW20-1ROADWORKAHEAD1515NE 16TH ST Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 3 of 9 MFP20004127 2909 NE 16th St Renton WA 98056 USA JEFFERSON AVE NENE 16TH ST 1515 16161414 1818 1717KIRKLAND AVE NENE 16 T H S T BUSSTOPBUS STOP 16161 6 16THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKSTOP FLAGGER STOP FLAGGER W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AW20-1ROADWORKAHEAD W20-4ONE LANEROADAHEADX'X'W20-1ROADWORKAHEAD15151515 USE MAXIMUM AVAILABLE SPACE FOR SIGNS Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 4 of 9 MFP20004127 KIRKLAND AVE NEJEFFERSON AVE NE1616W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'STOP FLAGGER STOP FLAGGER W20-1ROADWORKAHEADNE 13TH ST 16 16 16 16 PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-P A R K 1313THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA JEFFERSON AVE NEPuget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 5 of 9 MFP20004127 10 10 10 1010 10 10 101616 10 10 10 1017 1818 NE 12TH STKIRKLAND AVE NEKIRKLAND AVE NENE 12TH ST JEFFERSON AVE NEHARRINGTON PL NE16NE 13TH ST1313THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA STOP FLAGGER STOP FLAGGER RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA R K W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'15 15 15 15 W20-7APuget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 6 of 9 MFP20004127 171710 10 10 1010 10 10 1011 1 1 1 2 1 1 1 1 1616 10 10 10 1017 17 1818 KIRKLAND AVE NENE SUNSET BLVDKIRKLAND AVE NENE 12TH ST JEFFERSON AVE NEHARRINGTON PL NENE 13TH ST1313 THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA STOP FLAGGER RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ASTOP FLAGGER W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'X'W20-1ROADWORKAHEAD USE MAXIMUM AVAILABLE SPACE FOR SIGNS 1616 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 7 of 9 MFP20004127 NE SUNSET BLVD171710 10 10 1010 10 10 1011 1 1 1 2 1 1 1 1 17 1616 10 10 10 1017 17 1818 NE 12TH STKIRKLAND AVE NENE SUNSET BLVDK I R K L A N D A V E N EKIRKLAND AVE NENE 12TH ST JEFFERSON AVE NEHARRINGTON PL NE1 0 0 ' NE 13TH ST1313 STREETCLOSEDBARRICADE R11-2R11-4R5-133ROAD CLOSEDTOTHRU TRAFFICLOCALACCESSONLYROADWORKAHEADW20-1ROADCLOSEDAHEADW20-3100'100'ARRW-BRD ROADWORKAHEADW20-1100'100'100'RIGHT LANECLOSEDAHEADW20-5RW4-2LW20-1ROAD WORK AHEADW20-1ROADWORKAHEADW20-1 R O A D W O R K AH E A D W20-1ROADWORKAHEAD R9-3C/WCLOSEDR9-3 C/WCLOSEDR11-4R5-133ROAD CLOSEDTOTHRU TRAFFICLOCALACCESSONLYPLACE SIGN AT NE 16TH ST W20-1ROADWORKAHEADPLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be along NE 16th St from Index Ave NE to Jevverson Ave NE. Then South along Jefferson Ave NE until NE 12th St. 28" TRAFFIC CONE WORK PIT TRAFFIC FLOW SIGN LOCATION STOP FLAGGER LEGEND CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 8 of 9 MFP20004127 DETOURM4-9DETOURM4-9 DETOURM9-4R DETOURM9-4RDETOURM4-9LDETOURM4-9LNE 12TH ST KIRKLAND AVE NEDETOURM9-4RPuget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN DETOUR MAP N PSE PUGETSOUNDENERGY JOB#109129009 2909 NE 16TH ST, RENTON, WA 98056 07/10/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 9 of 9 MFP20004127 N Vicinity Map Owner / Developer Contact Info officeATTN: PSE N/A N/A PSE N/A Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 11714431 11714433 N/A 11714435 N/A 11714576 N/A N/A N/A N/A GAS PROJECT PHASE Notification #Order # SVC Retirement Relocate SAP Superior Service/Meter Service/Meter Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter SYSTEM MAOP DENOTED BY: SYSTEM MAOP = ___ PSIG BOX (TEST LEAD) INSTALLATION. THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. PURGE POINTS AND PRESSURE TAPS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3300, AND 2525.1200. ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO STANDARD GAS CONSTRUCTION NOTES: 14. 13. 15. 10. 11. THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 9. 6. 7. 5. 4. 3. 1. 60 16. IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ----------------- NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS).2. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED.12. ___________________________, PHONE______________. NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES17. FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD)109129009THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON HOLE HOG TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BP8 END BP9 START BP10 END BP11 START BP12 END BP13 START BP14 END BP15 START BP16 END BP17 START BP18 END BP19 START BP20 END PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PROJECT MANAGER TO MAKE EGOR RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300, 2525.3400 REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARDS 2525.2100 FOR INSERTIONS AND 2525.3600 FOR STANDARDS 2525.2100 AND 2525.3600. PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 11. 12. 14. 13. AND 2525.1200, AND PSE GAS FIELD PROCEDURE 4700.1500. PER PSE GAS OPERATING STANDARD 2550.1600. ABANDONMENT OR DEACTIVATION. 10. 9. 5. 6. 7. 8. GAS OPERATING STANDARD 2525.2300. 4. 1. 2. 3. OUTAGE. STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY:##### ROPE PROPOSED PIPE 2" MPE IP MAIN WORK AREA STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 60 IP088- 60 N/A 109129009 N/A 1"=30'1/5 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr INSTALL 2"MPE 1223' SITE PLAN SCALE: 1" = 100'-0" N/AMN Retirement RENTON 30 CSPSKGPI SW 04 -23-05 204.080 205.084 N/A N/A11714430 11714429 11531265 N/A 109129009 108620269 S. ALNEEMA 253.234.6301 425.559.4647 SAP BATCH YEAR & FOOTAGE ACTUAL LENGTH OF RETIREMENT MATERIAL RETIRED ORIGINAL JOB ORIGINAL YEAR PROPOSED LENGTH OF RETIREMENT SIZE OF RETIRED MAIN 108623986 RETIRE 2"MPE 1096' PUBLIC IMPROVEMENT NE 16TH ST AND JEFFERSON AVE NE 2909 NE 16TH ST RENTON 98056 16.ACTIVE SERVICES TO BE PARTIALLY REPLACED AND TEST & TIED DENOTED BY: 17.ACTIVE SERVICES TO BE TESTED & TIED DENOTED BY:##### ##### 425.559.4647 G. HELTON 425.559.4647 G. HELTON G. HELTON N/A Service/Meter NE 16 T H S T PLOT PLAN A SEE SHEET 2 PLOT PLAN B SEE SHEET 3 PLOT PLAN CSEE SHEET 4INDEX AVE NEJEFFERSON AVE NENE 13TH ST NE 12TH STPLOT PLAN DSEE SHEET 5NE 16 T H S T 11714410 11714421 N/A 11714422 N/A 11714423 N/A 11714428 N/A 10913280611714409 11714427 N/A 11714426 N/A Service/Meter Service/Meter Service/Meter Service/Meter Service/Meter Service/Meter Service/Meter MFP20004127 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR IP G A S F L O W NE 16TH ST INDEX AVE NE IP GA S F L O W IP GAS FLOW IP G A S F L O W28012807 28132811 28212815IP GAS FLOW IP GA S F L O W IP GAS FLOW THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON ROPE PROPOSED PIPE 2" MPE IP MAIN N/A PUBLIC IMPROVEMENT N/A 1"=30'2/5 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr TIE IN TEE 2"X2" INLINE TEE 2'S C/L & 6'W C/L ____'S C/L & ____'W C/L CUT & CAP CAP 2" MPE 25'S C/L & 4'W C/L ____'S C/L & ____'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN TIE IN TEE HV 2"X2" MPE 15'S C/L & 292'E C/L ___'S C/L & ___'E C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L Scale: NTS TIE IN DETAIL1 2 Scale: NTS TIE IN DETAIL2 2 CUT & CAP CAP 2" MPE 15'S C/L & 290'W C/L ____'S C/L & ____'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 2'S C/L & 292'E C/L ___'S C/L & ___'E C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 109129009 30 CSPSKGPI SW 04 -23-05 204.080 205.084 NE 16TH ST AND JEFFERSON AVE NE 2909 NE 16TH ST RENTON 98056 RENTON PLOT PLAN A SCALE: 1" = 30'-0" PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE STORM PIPE AT 6'-9" 2'S C/L, 218'E C/L PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE WATER PIPE AT 4'-3" 2'S C/L, 26'E C/L 2 2 1 2 (____')(____')NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 2' TO CLEAR TOP OF FUTURE STORM PIPE AT 2'-9" 16'S C/L, 230'E C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 2' TO CLEAR TOP OF FUTURE STORM PIPE AT 2'-10" 15'S C/L, 206'E C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE STORM PIPE AT 5' 9'S C/L, 55'E C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE STORM PIPE AT 5'-4" 15'S C/L, 139'E C/L PROPOSED PIPE 2" MPE IP MAIN 2'S C/L, ____S' C/L PROPOSED PIPE 2" MPE IP MAIN 2'S C/L, ____S' C/L MFP20004127 IP GAS FLOWIP GAS FLOW IP GAS FLOW IP GAS FLOW1501JEFFERSON AVE NENE 16TH ST IP GAS FLO W IP GAS FLOWIP GAS FLOW 15311527151915181526151015011500IP GAS FLO W THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON ROPE PROPOSED PIPE 2" MPE IP MAIN N/A PUBLIC IMPROVEMENT N/A 1"=30'3/5 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr Scale: NTS TIE IN DETAIL2 3 Scale: NTS TIE IN DETAIL3 3 S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 109129009 30 CSPSKGPI SW 04 -23-05 204.080 205.084 NE 16TH ST AND JEFFERSON AVE NE 2909 NE 16TH ST RENTON 98056 RENTON PLOT PLAN B SCALE: 1" = 30'-0" Scale: NTS TIE IN DETAIL1 3 TIE IN TEE 2"X2" INLINE TEE (SQUEEZE & FUSE TIE IN) 15'S C/L & 7'W C/L ____'S C/L & ____'W C/L CUT & CAP CAP 2" MPE 17'S C/L & 15'W C/L ____'S C/L & ____'W C/L CUT & CAP CAP 2" MPE 15'S C/L & 50'W C/L ____'S C/L & ____'W C/L CUT & CAP 473'S C/L & 15'W C/L ____'S C/L & ____'W C/L ELBOW 2"X90° MPE 9'S C/L & 7'W C/L ___'S C/L & ___'W C/L ELBOW 2"X90° MPE 9'S C/L & 52'W C/L ___'S C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 15'S C/L & 52'W C/L ___'S C/L & ___'W C/L ELBOW 2"X90° MPE 475'S C/L & 9'W C/L ___'S C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 475'S C/L & 15'W C/L ___'S C/L & ___'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE WATER PIPE AT 5.5' 9'S C/L, 4'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 9'S C/L, 35'E C/L PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE HYDRANT PIPE AT 4' 465'S C/L, 9'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN ROPE PROPOSED PIPE 2" MPE IP MAIN FROM 48'S C/L & 9'W C/L TO 54'S C/L & 9'W C/L FROM ____'S C/L & ____'W C/L TO ____'S C/L & ____'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'S C/L & ____'W C/L CUT & CAP CAP 2" MPE 15'S C/L & 5'W C/L ____'S C/L & ____'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'S C/L & ____'W C/L PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE WATER PIPE AT 5.5' 9'S C/L, 4'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 4' 9'S C/L, 7'E C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 9'S C/L, 35'E C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 45'S C/L, 8'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 45'S C/L, 8'W C/L 1 3 2 3 3 3 PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 4' 151'S C/L, 9'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 4' 312'S C/L, 9'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 385'S C/L, 9'W C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 3' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 2'-3" 215'S C/L, 15'W C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 3' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 2'-3" 294'S C/L, 15'W C/L NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 3' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 2'-4" 294'S C/L, 15'W C/L (____')(____')(____') (____')(____')NEW STUB 1 1/8" PE BOTTOM OF PIPE TO BE BURIED AT 2'-4" TO CLEAR TOP OF FUTURE STORM PIPE AT 3' 324'S C/L, 8'E C/L NEW STUB 1 1/8" PE BOTTOM OF PIPE TO BE BURIED AT 2'-4" TO CLEAR TOP OF FUTURE STORM PIPE AT 3' 257'S C/L, 8'E C/L MFP20004127 JEFFERSON AVE NENE 13TH ST JEFFERSON AVE NEIP GAS FLOW141014091333IP GAS FLOW1410IP GAS FLOWTHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON ROPE PROPOSED PIPE 2" MPE IP MAIN N/A PUBLIC IMPROVEMENT N/A 1"=30'4/5 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 109129009 30 CSPSKGPI SW 04 -23-05 204.080 205.084 NE 16TH ST AND JEFFERSON AVE NE 2909 NE 16TH ST RENTON 98056 RENTON Scale: NTS TIE IN DETAIL2 4PLOT PLAN C SCALE: 1" = 30'-0" 1 4 2 4 MATCHLINE A-A SEE SHEET 5 Scale: NTS TIE IN DETAIL1 4 CUT & CAP 11'N C/L & 15'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 9'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 9'N C/L & 15'W C/L ___'N C/L & ___'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L CUT & CAP 52'N C/L & 15'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 54'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 54'N C/L & 15'W C/L ___'N C/L & ___'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L CUT & CAP 298'N C/L & 15'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 296'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 296'N C/L & 15'W C/L ___'N C/L & ___'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L CUT & CAP 339'N C/L & 15'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 341'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 341'N C/L & 15'W C/L ___'N C/L & ___'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3'-3" 21'N C/L, 9'W C/L PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 4' 306'N C/L, 9'W C/L (____') (____') (____') (____')(____')(____')NEW STUB 1 1/8" PE TOP OF PIPE TO BE BURIED AT 4' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3' 332'N C/L, 16'E C/L MFP20004127 ••••••••••••••••••••••••••••••••••••••••••NE 12TH STJEFFERSON AVE NE133312171209IP GAS FLOWIP GAS FLOW1209THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 425.559.4647 glenn.helton@pse.com GLENN HELTON ROPE PROPOSED PIPE 2" MPE IP MAIN N/A PUBLIC IMPROVEMENT N/A 1"=30'5/5 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr S. ALNEEMA 253.234.6301 G.HELTON 425.559.4647 109129009 30 CSPSKGPI SW 04 -23-05 204.080 205.084 NE 16TH ST AND JEFFERSON AVE NE 2909 NE 16TH ST RENTON 98056 RENTON Scale: NTS TIE IN DETAIL2 5 PLOT PLAN D SCALE: 1" = 30'-0" 2 5 1 5 CUT & CAP 26'N C/L & 17'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 24'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 24'N C/L & 17'W C/L ___'N C/L & ___'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 4' 33'N C/L, 9'W C/L CUT & CAP 254'N C/L & 15'W C/L ____'N C/L & ____'W C/L ELBOW 2"X90° MPE 256'N C/L & 9'W C/L ___'N C/L & ___'W C/L TIE IN TEE HV 2"X2" MPE 256'N C/L & 15'W C/L ___'N C/L & ___'W C/L TEE TAP 2"X5/8" MPE (GAUGE TEE) ____'N C/L & ____'W C/L DEACTIVATE IN PLACE EXISTING 2" MPE IP MAIN (____') (____')(____')(____')Scale: NTS TIE IN DETAIL1 5 PROPOSED PIPE 2" MPE IP MAIN TOP OF PIPE TO BE BURIED AT 5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 33'N C/L, 9'W C/L MATCHLINE A-A SEE SHEET 4 PROPOSED PIPE 2" MPE IP MAIN BOTTOM OF PIPE TO BE BURIED AT 3' TO CLEAR TOP OF FUTURE HYDRANT PIPE AT 4' 33'N C/L, 9'W C/L NEW STUB 1 1/8" PE BOTTOM OF PIPE TO BE BURIED AT 2.5' TO CLEAR BOTTOM OF FUTURE STORM PIPE AT 3.5' 53'N C/L, 5'E C/L POLYVALVE 1 1/8" MPE (OPEN) WITH VALVE BOX & SUPPORT 53'N C/L & 7'W C/L ____'N C/L & ____'W C/L MFP20004127