HomeMy WebLinkAboutP_N 29th_Permit_Set_20200702_v1A.C.T.ACOUSTICAL CLG TILE
CD CARBON MONOXIDE DETECTOR
CLG CEILING
C.T.COMMON TRUSS
CLR CLEAR
COMP COMPOSITION
CONC CONCRETE
DBL DOUBLE
DIA DIAMETER
F.F.FINISH FLOOR
F.E.FIRE EXTINGUISHER
F.E.C.FIRE EXTINGUISHER CABINET
F.D.FLOOR DRAIN
FLR FLOOR
G.T.GIRDER TRUSS
GWB GYPSUM WALL BOARD
GYP GYPSUM
HDWD HARDWOOD
HGT HEIGHT
H.M.HIP MASTER
MFR MANUFACTURER
MIL MILLIMETERS
N.I.C.NOT IN CONTRACT
N.T.S.NOT TO SCALE
O.C.ON CENTER
PLYW'D PLYWOOD
P.T.PRESSURE TREATED
REFER REFRIGERATOR
R.A.RETURN AIR
R.O.ROUGH OPENING
R&S ROD AND SHELF
S.A.SUPPLY AIR
SCHED SCHEDULE
SD SMOKE DETECTOR
SH SHELVES
SHT SHEET
SHWR SHOWER
SIM SIMULAR
S.S.STAINLESS STEEL
STOR STORAGE
SUSP SUSPENDED
TEL TELEPHONE
THERM THERMOSTAT
TYP TYPICAL
U.C.L.UNDERCABINET LIGHTS
U.N.O.UNLESS NOTED OTHERWISE
V VINYL
VB VAPOR BARRIER
V.C.T.VINYL COMPOSITION TILE
VTOS VENT TO OUTSIDE
W.C.WATER CLOSET
W.P.WATER PROOF
w/WITH
w/o WITHOUT
WD WOOD
W/D WASHER AND DRYER
PROJECT ADDRESS:
BUILDER:
909 N 29TH STREET
RENTON, WA, 98056
DESIGNER:
SCOPE OF WORK:
ENGINEER:
LEGAL DESCRIPTION:
BIDDER DESIGN:
ELECTRICAL, MECHANICAL, PLUMBING, MFR TRUSS
CONNECTIONS, EXTERIOR CLADDING TO BE BIDDER
DESIGNED/DEFERRED SUBMITTAL (PER 106.3.4.2)
CONSTRUCT A NEW XXXX SQ FT
RESIDENCE.
ATERA HOMES, LLC
451 DUVALL AVE NE, SUITE 115
RENTON, WA, 98059
CONTACT:PAUL MONSEF
PHONE:(206) 612-8647
EMAIL:paul@monsefdesign.com
MONSEF DESIGN STUDIO, LLC
451 DUVALL AVE NE, SUITE 115
RENTON, WA 98059
CONTACT:MILTON ORELLANA
PHONE:(425) 306-2758
EMAIL:Milton@aterahomes.com
LOT 3, BLOCK 12, C.D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN ADDITION TO SEATTLE NO. 1,
ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 63, RECORDS OF
KING COUNTY, WASHINGTON;
SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
BTL ENGINEERING
19011 WOODINVILLE SNOHOMISH ROAD NE, SUITE 100
WOODINVILLE, WA 98072-4436
CONTACT:RYAN HARTMAN
PHONE:425-814-8448
FAX: 425-821-2120
EMAIL:ryan.hartman@btleng.net
AREA, SQUARE...
Name Area
Lower Floor 1457 SF
MainFloor 2102 SF
Gross Building Area: 23559 SF
Garage 634 SF
Porch 92 SF
Covr'd Balcony 306 SF
Exterior Area: 4 1032 SF
Grand total: 6 4590 SF
ENERGY COMPLIANCE
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1 : 1
7/2/2020 9:49:02 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtCOVER SHEET
19011
2020/06/05
SPM
A000
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
ENERGY CODE NOTES
DRAWING INDEX
NUMBER SHEET NAME REV. ID REV. DATE
EXHIBIT 'A'FLOW CONTROL BMP SITE PLAN
LP LANDSCAPE PLAN
SP SITE PLAN
TESC EROSION CONTROL PLAN
: 4
A000 COVER SHEET
A001 CODE NOTES
A002 ENERGY NOTES
A003 ENERGY/VENTING CALCULATIONS
A100 SURVEY
A101 SITE PLAN & AREA/HT CALCULATIONS
A301 MAIN FLOOR
A401 UPPER FLOOR
A501 UPPER ROOF PLAN
A601 ELEVATIONS
A701 SECTIONS
A702 SECTIONS
A801 SCHEDULES
ARCHITECTURAL 'A': 13
D101 FOUNDATION & FRAMING DETAILS
D102 FRAMING DETAILS
D301 ROOF DETAILS
DETAIL 'D': 3
i101 INTERIOR PLANS
i102 INTERIOR PLANS
i201 KITCHEN INTERIORS
i202 POWDER ROOM
i203 MASTER BATH
INTERIORS 'i': 5
S101 GENERAL STRUCTURAL NOTES
S201 FOUNDATION/MAIN FLOOR FRAMING PLAN
S301 UPPER FLOOR FRAMING PLAN
S401 ROOF FRAMING PLAN
S601 STRUCTURAL DETAILS
S602 STRUCTURAL DETAILS
S603 STRUCTURAL DETAILS
STRUCTURAL 'S': 7
VICINITY MAPABBREVIATIONS PROJECT INFO
PROPOSED RESIDENCE TO COMPLY WITH THE PRESCRIPTIVE VENTILATION REQUIREMENTS OF SECTION
M1507 OF THE IRC.
AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM INTEGRATED WITHIN THE FORCED AIR SYSTEM
**SEE THE MECHANICAL VENTILATION M1507 OF THE WA STATE RESIDENTIAL CODE SECTION ON SHEET
A002
MECHANICAL VENTILATION REQUIREMENTS
PROPOSED RESIDENCE TO COMPLY WITH THE PRESCRIPTIVE REQUIREMENTS OF THE 2015 W.S.E.C. -
SEE WSEC FORM/REQUIREMENTS ON SHEET A002 & A003.
SHT#
SYMBOLS & LEGEND:
A101
1 SIM
NEW WALL: INFILL PHASE EXISTING WALL: SHELL / CORE PHASE
GRID LINES
SHEET LAYOUT DESIGNATION: VIEW # / SHEET #
DOOR TAG:
-SEE DOOR SCHEDULE.
ELEVATION DESIGNATION: VIEW # / SHEET #
SHEARWALL TAG: SEE SHEARWALL SCHEDULEWINDOW TAG:
-SEE WINDOW SCHEDULE
EXIST. CONTOURS
NEW CONTOURS
INDICATES STRUCTURAL KEYNOTE WITH INDEXED
NUMBER.
SEE STRUCTURAL KEYNOTE SCHEDULE.
EXHAUST FAN PER M1507:
-50 CFM MIN., TYP. U.N.O.
-100 CFM MIN. @ KITCH.
WHOLE HOUSE EXHAUST FAN:
-150 CFM MIN.
-SEE M1507.3 ON SHT A002
THERMOSTAT:
-PROVIDE 2x8 BLK'G AT 51"
A.F.F.
T
24HR TIMER TO W.H. FAN
-SEE M1508 ON SHT
A002
T
WH
FURN
110V SMOKE DETECTOR PER R314:
-W/ DISCONNECTION SWITCH & BATTERY BACKUPSD
CARBON MONOXIDE DETECTOR PER R315CD
FURNACE/WATER HEATER:
-PROVIDE COMBUSTIONABLE AIR FROM
OUTSIDE.
-PROVIDE PRESSURE RELIEF LINE TO OUTSIDE.
-SECURE WATER HEATER TOP & BOTTOM.
HD#
003
01 sw#
GRID
GRID
CODE INFORMATION:
BUILDING AREAS:SEE SQUARE FOOTAGE SCHED. THIS SHEET.
CODE COMPLIANCE:2015 IBC with statewide and City amendments
CONTR. CLASS:TYPE V CONSTRUCTION
GLAZING:SEE ENERGY CODE NOTES ON THIS SHEET.
PARCEL #:334210-0737
ZONE:R-8
GENERAL INFORMATION:
PARCEL DESCRIPTION:
PROPERTY TYPE:R -RESIDENTIAL SINGLE
PRESENT USE:FAMILY(RES USE/ZONE)
LOT AREA:5,104 SF
PLAT BLOCK:12
PLAT LOT:3
Q-S-T-R: SW-32-24-5
EFFICIENT BUILDING ENVELOPE 1A:
PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS:
• FENESTRATION U VALUE = 0.28
• FLOOR INSULATION = R-38
• SLAB ON GRADE = R-10 PERIMETER AND UNDER ENTIRE SLAB AT CONDITIONED SPACES
• SLAB BELOW GRADE = R-10 PERIMETER AND UNDER ENTIRE SLAB AT CONDITIONED SPACES
HIGH EFFICIENCY HVAC 3A:
GAS, PROPANE OR OIL FIRED FURNACE WITH MINIMUM AFUE OF 94%, OR
GAS, PROPANE OR OIL FIRED BOILER WITH MINIMUM AFUE OF 92%
• Furnace or Boiler: Manufacturer/Model #:
1. BRYANT 215 SERIES
2. SEER: 15
3. HSPF: 8.5
EFFICIENT WATER HEATING 5A:
WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING:
• GAS, PROPANE OR OIL WATER HEATER WITH A MINIMUM EF OF 0.62 OR ELECTRIC WATER
HEATER WITH A MINIMUM EF OF 0.93.
1. FOR BOTH CASES ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE
HOUSE SHALL BE RATED AT 1.75 GPM OR LESS.
2. ALL OTHER LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR LESS.
EFFICIENT WATER HEATING 5C:
THE PROPOSED WATER HEATING SYSTEM SHALL INCLUDE A HIGH EFFICIENCY CONDENSING TANKLESS
GAS WATER HEATER WITH A MINIMUM EF OF 0.91.
PROPOSED MODEL:
• NORITZ TANK LESS NATURAL GAS WATER HEATER, MODEL NRC98DV
• UNIFORM ENERGY FACTOR: 0.91 (NG)No.DateDescription
TABLE R602.3(1)
FASTENERS SCHEDULE FOR STRUCTURAL MEMBERS
ITEM DESCRIPTION OF BUILDING MATERIALS NUMBER AND TYPE OF
FASTENER a, b, c SPACING OF FASTENERS
ROOF
1 BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE 3-8d (2-1/2" x 0.131")TOE NAIL
2 CEILING JOISTS TO TOP PLATE 3-8d (2-1/2" x 0.131")PER JOIST, TOE NAIL
3 CLG JSTS NOT ATTACHED TO PARALLEL RFTRS, LAPS OVER PARTITIONS 4-10d BOX (2-1/2" x 0.113")
OR 3-16d C (3-1/2" x 0.162")FACE NAIL
4 CEILINGJOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT)PER TABLE R802.5.1(9)FACE NAIL
5 COLLAR TIE RAFTER, OR 1-1/4"x20 GAGE RIDGE STRAP TO RAFTER 3-10d (3" x 0.148")FACE NAIL EACH RAFTER
6 RAFTER TO PLATE 3-16d (3-1/2" x 0.135")
2 TOE NAILS ON ONE SIDE
AND 1 ON OPPOSITE,
EACH RAFTER/TRUSS
7 ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS:4-16d (3-1/2" x 0.135")TOE NAIL
3-16d (3-1/2" x 0.135")END NAIL
WALL
7 BUILT-UP CORNER STUDS 10d (3" x 0.128")24" O.C.
8 BUILT-UP HEADER, TWO PIECES WITH 1/2" SPACER 16d (3-1/2" x 0.135")
16" O.C. ALONG EACH
EDGE9CONTINUED HEADER, TWO PIECES 16d (3-1/2" x 0.135")
10 CONTINUOUS HEADER TO STUD, TOE NAIL 4-8d (2-1/2" x .0113")
11 DOUBLE STUDS, FACE NAIL 10d (3" x 0.128")24" O.C.12 DOUBLE TOP PLATE, FACE NAIL 10d (3" x 0.128")
13 DOUBLE TOP PLATES, MINIMUM 24-INCH OFFSET OF END JOINTS,- FACE NAIL IN LAPPED AREA 8-16d (3-1/2" x 0.135")
14 SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL 16d (3-1/2" x 0.135")
16" O.C.
15 SOLE PLATE TO JOIST BLOCKING AT BRACED WALL PANELS 3-16d (3-1/2" x 0.135")
16 STUD TO SOLE PLATE, TOE NAIL
3-8d (2-1/2" x 0.113")
OR
2-16d (3-1/2" x 0.135")
17 TOP OR SOLE PLATE TO STUD, END NAIL 2-16d (3-1/2" x 0.135")
18 TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL 2-10d (3" x 0.128")
19 1" BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d (2-1/2" x 0.113")
2 STAPLES 1-3/4"
20 1" X 6" SHEATHING TO EACH BEARING, FACE NAIL 2-8d (2-1/2" x 0.113")
2 STAPLES 1-3/4"
21 1" X 8" SHEATING TO EACH BEARING, FACE NAIL 2-8d (2-1/2" x 0.113")
2 STAPLES 1-3/4"
22 WIDER THAN 1" X 8" SHEATHING TO EACH BEARING, FACE NAIL 3-8d (2-1/2" x 0.113")
4 STAPLES 1-3/4"
FLOOR
23 JOIST TO SILL OR GIRDER, TOE NAIL 3-8d (2-1/2" x 0.113")
-24 1" X 6" SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL 2-8d (2-1/2" x 0.113")
2 STAPLES 1-3/4"
25 2" SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL 2-16d (3-1/2" x 0.135")
26 RIM JOIST TO TOP PLATE, TOE NAIL (ROOF APPLICATIONS ALSO)8d (2-1/2" x .0113")6" O.C.
27 2" PLANKS (PLANK & BEAM - FLOOR & ROOF)2-16d (3-1/2" x 0.135")AT EACH BEARING
28 BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS 10d (3" x 0.128")
NAIL EACH LAYER AS
FOLLOWS: 32" O.C. AT
TOP AND BOTTOM AND
STAGGERED. TWO NAILS AT
ENDS AND AT EACH SPLICE
29 LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 3-16d (3-1/2" x 0.135")AT EACH JOIST OR RFTR
ITEM DESCRIPTION OF
BLDG MATERIALS DESCRIPTION OF FASTENER a, b, c SPACING OF FASTENERS
EDGES i INTERMEDIATE SUPPORTS c, e
WOOD STRUCTURE PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING TO FRAMING AND PARTICLEBOARD WALL SHEATHING TO FRAMING
30 3/8" - 1/2"6d COMMON (2" x 0.113") NAIL (SUBFLOOR WALL) i
6"12" (g)
8d COMMON (2-1/2" x 0.131") NAIL (ROOF)
31 5/16" - 1/2"6d COMMON (2" x 0.113") NAIL (SUBFLOOR WALL)
8d COMMON (2-1/2" x 0.131") NAIL (ROOF)f
32 19/32" - 1"8d COMMON NAIL (2-1/2" x 0.131")
33 1-1/8" -1 -1/4"10d COMMON (3" x 0.148" NAIL OR
8d (2-1/2" x 0.131") DEFORMED NAIL
FOR SI: 1 INCH = 25.4 MM. 1 FOOT = 304.8 MM, 1 MILE PER HOUR = 0.447 M/S; 1KSI = 6.895 MPA
a.ALL NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND
SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE BENDING YIELD STRENGTHS AS SHOWN: 80 KSI FOR SHANK DIAMETER OF
0.192 INCH (20d COMMON NAIL), 90 KSI FOR SHANK DIAMTERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND
100KSI FOR SHANK DIAMETERS OF 0.142 INCH OR LESS.
b.STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7/16-INCH ON DIAMETER CROWN WIDTH
c.NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER
d.4 X 8 FOOT OR 4 X 9 FOOT PANELS SHALL BE APPLIED VERTICALLY
e.SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(2)
f.FOR REGIONS HAVING BASIC WIND SPEED OF 110 MPH OR GREATER, 8d DEFORMED (2-1/2" x 0.120) NAILS SHALL BE USED FOR
ATTACHING PLYWOOD AND WOOD STUCTURAL PANEL ROOF SHEATHING TO FRAMING WITHIN MINIMUM 48-INCH DISTANCE FROM GABLE
END
WALLS, IF MEAN ROOF HEIGHT IS MORE THAN 25 FEET, UP TO 35 FEET MAXIMUM.
g.FOR REGIONS HAVING BASIC WIND SPEED OF 100 MPH OR LESS, NAILS FOR ATTACHING WOOD STRUCTURAL PANEL ROOF SHEATHING TO
GABLE END WALL FRAMING SHALL BE SPACED 6 INCHES ON CENTER. WHEN BASIC WIND SPEED IS GREATER THAN 100 MPH, NAILS FOR
ATTACHING PANEL ROOF SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE SPACED 6 INCHES ON CENTER FOR MINIMUM 48-INCH
DISTANCE FROM RIDGES, EAVES AND GABLE END WALLS; AND 4 INCHES ON CENTER TO GABLE END WALL FRAMING.
h.GYP SHEATHING SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH GA 253. FIBERBOARD SHEATHING
SHALL CONFORM TO ASTM C 208
i.SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRE
BLOCKING AND AT ALL FLOOR PERIMETERS ONLY. SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES
SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING. BLOCKING OF ROOF OR FLOOR SHEATHING PANEL EDGES PERPENDICULAR
TO THE FRAMING MEMBERS NEED NOT BE PROVIDED EXCEPT AS REQUIRED BY OTHER PROVISIONS OF THIS CODE. FLOOR PERIMETER
SHALL BE SUPPORTED BY FRAMING MEMBERS OR SOLID BLOCKING.SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM7/2/2020 8:52:42 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtCODE NOTES
19011
2020/06/05
SPM
A001
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
15 PSF
12 PSF
10 PSF
FLOOR:
ROOF:
WALLS:
ATTICS WITH STORAGE:
WITHOUT STORAGE:
DECKS:
EXTERIOR BALCONIES:
FIRE ESCAPES:
40 PSF
60 PSF
40 PSF
200 PLF
20 PSF
10 PSF
200 PLF
200 PSF
SLEEPING ROOMS:
40 PSF
30 PSF
STAIRS:40 PSF
ROOF SLOPE:
0 to 200 2001 to 600 Over 600
NEGLIGIBLE MODERATE SEVERE
2,500 psi 2,500 psi 2,500 psi
2,500 psi 2,500 psi 2,500 psi
2,500 psi 3,000 psi 3,000 psi
2,500 psi 3,000 psi 3,500 psi
CRYSTALLINE BEDROCK 12,000
3,000
2,000***
1,500
4,000
R403
FOOTINGS
• 1/4" X 3" X 3" PLATE WASHERS CONFORMING TO SECTION R602.11.1 SHALL BE
USED ON EACH BOLT.
• INTERIOR BRACED WALL PLATES SHALL HAVE ANCHOR BOLTS SPACED AT NOT MORE
THAN 6 FEET ON CENTER AND LOCATED WITHIN 12 INCHES FROM THE ENDS OF
EACH PLATE SECTION WHEN SUPPORTED ON A CONTINUOUS FOUNDATION.
• INTERIOR BEARING WALL SOLE PLATES SHALL HAVE ANCHOR BOLTS SPACED AT NOT
MORE THAN 6 FEET ON CENTER AND LOCATED WITHIN 12 INCHES FROM THE ENDS
OF EACH PLATE SECTION WHEN SUPPORTED ON A CONTINUOUS FOUNDATION.
• THE MAXIMUM ANCHOR BOLT SPACING SHALL BE 4 FEET FOR BUILDINGS OVER TWO
STORIES IN HEIGHT.
• STEPPED CRIPPLE WALLS SHALL CONFORM TO SECTION R602.11.3.
R402
MATERIALS
402.2 CONCRETE.
CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH AS SHOWN IN
TABLE R402.2 . CONCRETE SUBJECT TO WEATHERING AS INDICATED IN TABLE R301.2(1)
SHALL BE AIR ENTRAINED AS SPECIFIED IN TABLE R402.2
TABLE R402.2
MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
R401
GENERAL
401.1 APPLICATION.
THE PROVISIONS SET FORTH IN CHAPTER 4 OF THE IRC SHALL CONTROL THE DESIGN AND
CONSTRUCTION OF THE FOUNDATION AND FOUNDATION SPACES FOR ALL BUILDINGS. IN
ADDITION TO THE PROVISIONS OF THIS CHAPTER, THE DESIGN AND CONSTRUCTION OF
FOUNDATIONS IN AREAS PRONE TO FLOODING AS ESTABLISHED BY TABLE R301.2(1)
SHALL MEET THE PROVISIONS OF SECTION R322.
401.4 SOIL TESTS.
IN AREAS LIKELY TO HAVE EXPANSIVE, COMPRESSIBLE, SHIFTING OR OTHER UNKNOWN
SOIL CHARACTERISTICS, THE BUILDING OFFICIAL SHALL DETERMINE WHETHER TO REQUIRE
A SOIL TEST TO DETERMINE THE SOIL'S CHARACTERISTICS AT A PARTICULAR LOCATION,
401.4.1 GEOTECHNICAL EVALUATION.
IN LIEU OF A COMPLETE GEOTECHNICAL EVALUATION, THE LOAD-BEARING VALUES IN TABLE
R401.4.1 SHALL BE USED. TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF
FOUNDATIONS MATERIALS
***U.N.O. 2,000 PSF SOIL BEARING IS ASSUMED FOR THIS PROJECT. VERIFY WITH
STRUCTURAL NOTES
TRIBUTARY LOADED AREA IN SQUARE FEET
FOR ANY STRUCTURAL MEMBER
PORCHES, CARPORT SLABS & STEPS EXPOSED
TO WEATHER & GARAGE FLOOR SLABS.
R301
DESIGN CRITERIA
301.4 DEAD LOAD.
THE ACTUAL WEIGHTS OF MATERIALS AND CONSTRUCTION SHALL BE USED FOR DETERMINING
DEAD LOAD. DEAD LOADS USED FOR THIS PROJECT ARE AS FOLLOWS:
301.5 LIVE LOAD.
THE MINIMUM UNIFORMLY DISTRIBUTED LIVE LOAD SHALL BE AS PROVIDED IN
TABLE R301.5.
TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
301.6 ROOF LOAD.
ROOF SHALL BE DESIGNED FOR THE LIVE LOAD INDICATED IN TABLE R301.6 THE SNOW LOAD
INDICATED IN TABLE R301.2(1), WHICHEVER IS GREATER.
TABLE R301.6
MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE
301.8 NOMINAL SIZES.
...WHERE DIMENSIONS OF LUMBER ARE SPECIFIED, THEY SHALL BE DEEMED TO BE NOMINAL
DIMENSIONS UNLESS SPECIFICALLY DESIGNATED AS ACTUAL DIMENSIONS.
R317
PROTECTION AGAINST DECAY317.1 LOCATION REQUIRED.
IN AREAS SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY TABLE R301.2(1)LOCATIONS
REQUIRED BY SECTION R317.1, SHALL BE PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA
U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE
LISTED IN SECTION 4 OF AWPA U1
317.1.1 FIELD TREATMENT
FIELD-CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE
TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4.
6.1 GENERAL
• ALL CUTS, HOLES AND INJURIES SUCH AS ABRASIONS OR HOLES FROM
REMOVAL OF NAILS AND SPIKES WHICH MAY PENETRATE THE TREATED ZONE
SHALL BE FIELD TREATED. AN AWPA ACCEPTED PRESERVATIVE SYSTEM,
DETERMINED APPROPRIATE IN ACCORDANCE WITH AWPA M4 SECTION 7, SHALL
BE USED FOR FIELD TREATMENT.
• APPLY PRESERVATIVES IN ACCORDANCE WITH THE PRODUCT LABEL.
• COAT ANY SURFACE THAT IS EXPOSED BY DAMAGE OR FIELD FABRICATION
WHILE NOT USING EXCESS PRESERVATIVE.
• ANY EXCESS PRESERVATIVE NOT ABSORBED BY THE WOOD PRODUCT SHALL BE
CLEANED FROM THE SURFACE PRIOR TO THE USE OF THE PRODUCT.
• BORED HOLES FOR CONNECTORS OR BOLTS MAY BE TREATED BY PUMPING
COAL-TAR ROOFING CEMENT MEETING ASTM D5643 INTO HOLES USING A
GREASE GUN OR SIMILAR DEVICE.
• CAREFUL ATTENTION SHOULD BE GIVEN TO MATERIALS PLACED INTO WET
ENVIRONMENTS.
• AREA TO BE TREATED SHALL BE CLEAN, DRY AND FREE OF EXCESS
PRESERVATIVE.
7.1 PRESERVATIVES
• THE PRESERVATIVE SYSTEM FOR FIELD TREATMENT SHALL BE DETERMINED BY
THE TYPE OF PRESERVATIVE ORIGINALLY USED TO PROTECT THE PRODUCT.
• THE PRESERVATIVES DESIGNATED IN AWPA M4 SECTIONS 7.1.1, AND 7.1.2
ARE SUITABLE ALTERNATIVES WHEN NO MATCH CAN BE FOUND.
RISE 12" PER FOOT (1:1) AND
GREATER.
FLAT OR RISE LESS THAN 4" PER
FOOT (1:3).
RISE LESS 4" PER FLOOR (1:3)
to 12" PER FOOT (1:1).
TRIBUTARY LOADED AREA IN SQUARE FEET FOR ANY
STRUCTURAL MEMBER
16
12
20
14
12
16
12
12
12
GUARDRAIL IN-FILL COMPONENTS:
ROOMS OTHER THAN SLEEPING ROOMS:
PASSENGER VEHICLE GARAGES:
GUARDRAILS AND HANDRAILS:
R101
TITLE, SCOPE AND PURPOSE
CHAPTER 3: BUILDING PLANNING
TYPE OF LOCATIONS OF CONC.
CONSTRUCTION
BASEMENT WALLS, FNDN WALLS,
EXTERIOR WALLS EXPOSED TO WEATHER.
BASEMENT SLABS & INTERIOR SLABS ON
GRADE, EXCEPT GAR. FLOOR SLABS.
BASEMENT WALLS, FNDN'S EXPOSED
TO WEATHER.
SEDIMENTARY AND FOLIATED ROCK
CLAY, SANDY CLAY, SILTY
CLAY,CLAYEY SILT, SILT AND SANDY
SILT (CI,ML,MH & CH)
SAND, SILTY SAND, CLAYEY SAND,
SILTY GRAVEL AND CLAYEY GRAVEL
(SW,SP,SM,SC,GM & GC)
SANDY GRAVEL AND/OR GRAVEL (GW
AND GP)
CLASS OF MATERIAL LOAD BEARING PRESSURE (PSF)
CHAPTER 1: ADMINISTRATION
CHAPTER 4: FOUNDATIONS
CHAPTER 9: ROOF ASSEMBLIES
R901
GENERAL
901.1 SCOPE.
THE PROVISIONS SET FORTH IN CHAPTER 9 OF THE IRC, SHALL GOVERN THE DESIGN,
MATERIALS, CONSTRUCTION AND QUALITY OF ROOF ASSEMBLIES.
R801
GENERAL
801.1 APPLICATION.
THE PROVISIONS SET FORTH IN CHAPTER 8 OF THE IRC, SHALL CONTROL THE DESIGN AND
CONSTRUCTION OF THE ROOF-CEILING SYSTEM FOR ALL BUILDINGS.
801.2 REQUIREMENTS.
ROOF AND CEILING CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS
IMPOSED ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS
TO THE SUPPORTING STRUCTURAL ELEMENTS.
801.3 ROOF DRAINAGE.
IN AREAS WHERE EXPANSIVE OR COLLAPSIBLE SOILS ARE KNOWN TO EXIST, ALL DWELLINGS
SHALL HAVE A CONTROLLED METHOD OF WATER DISPOSAL FROM ROOFS THAT WILL
COLLECT AND DISCHARGE ALL ROOF DRAINAGE TO THE GROUND SURFACE AT LEAST 5 FEET
FROM FOUNDATION WALLS OR TO AN APPROVED DRAINAGE SYSTEM.
R701
GENERAL
701.1 APPLICATION.
THE PROVISIONS SET FORTH IN CHAPTER 7 OF THE IRC, SHALL CONTROL THE DESIGN
AND CONSTRUCTION OF THE INTERIOR AND EXTERIOR WALL COVERING FOR ALL BUILDINGS.
701.2 INSTALLATION.
PRODUCTS SENSITIVE TO ADVERSE WEATHER SHALL NOT BE INSTALLED UNTIL ADEQUATE
WEATHER PROTECTION FOR THE INSTALLATION IS PROVIDED. EXTERIOR SHEATHING SHALL
BE DRY BEFORE APPLYING EXTERIOR COVER.
CHAPTER 8: ROOF-CEILING CONSTRUCTION
CHAPTER 7: WALL COVERING
R404
FOUNDATION WALLS
404.1 CONCRETE AND MASONRY FOUNDATION WALLS.
CONCRETE AND MASONRY FOUNDATION WALLS SHALL BE SELECTED AND CONSTRUCTED IN
ACCORDANCE WITH THE PROVISIONS OF SECTION R404.1.3 OF THE IRC OR IN
ACCORDANCE WITH ACI 318, NCMA TR68-A OR ACI 530/ASCE 5/TMS 402 OR OTHER
APPROVED STRUCTURAL STANDARDS.
404.3 WOOD SILL PLATES.
WOOD SILL PLATES SHALL BE A MINIMUM OF 2-INCH BY 4-INCH NOMINAL LUMBER. SILL
PLATE ANCHORAGE SHALL BE IN ACCORDANCE WITH SECTIONS R403.1.6 AND R602.11.
R613
EXTERIOR WINDOWS AND GLASS DOORS
613.1 GENERAL.
THE PROVISIONS SET FORTH IN SECTION 613 OF THE IRC, SHALL CONTROL THE
PERFORMANCE AND CONSTRUCTION REQUIREMENTS FOR EXTERIOR WINDOW SYSTEMS
INSTALLED IN WALL SYSTEMS. WATERPROOFING, SEALING AND FLASHING SYSTEMS ARE
NOT INCLUDED IN THE SCOPE OF THIS SECTION.
613.2 PERFORMANCE.
EXTERIOR WINDOWS AND DOORS SHALL BE DESIGNED TO RESIST THE DESIGN WIND
LOADS SPECIFIED IN TABLE R301.2(2) ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE
R301.2(3).
R601
GENERAL
R501
GENERAL
501.1 APPLICATION.
FLOOR CONSTRUCTION SHALL BE IN ACCORDANCE TO THE PROVISIONS SET FORTH IN
CHAPTER 5 OF THE IRC.
501.2 REQUIREMENTS.
FOR FLOOR CONSTRUCTION LOADING, SEE SECTION R301.
CHAPTER 6: WALL CONSTRUCTION
CHAPTER 5: FLOORS
2015 UNIFORM PLUMBING CODE
313
PROTECTION OF PIPING, MATERIALS, AND STRUCTURES
SECTION 313.12 RATPROOFING
a. STRAINER PLATES ON DRAIN INLETS SHALL HAVE ½-INCH OPENINGS MAX.
b. METER BOXES SHALL BE CONSTRUCTED IN SUCH A MANNER THAT RATS CANNOT
ENTER A BLDG BY FOLLOWING THE SERVICE PIPES FROM THE BOX INTO THE BLDG.
c. WHERE OPENINGS HAVE BEEN MADE IN WALLS, FLOORS, OR CLGS FOR THE PASSAGE
OF PIPES, SUCH OPENINGS SHALL BE CLOSED AND PROTECTED BY THE INSTALLATION
OF APPROVED METAL COLLARS SECURELY FASTENED TO THE ADJOINING STRUCTURE.
d. TUB WASTE OPENINGS IN FRAMED CONSTRUCTION TO CRAWL SPACES AT OR BELOW
THE FIRST FLOOR SHALL BE PROTECTED BY THE INSTALLATION OF APPROVED METAL
COLLARS OR METAL SCREEN, WITH ½-INCH OPENINGS MAX, AND SECURELY
FASTENED TO THE ADJOINING STRUCTURE.
317.1.2 GROUND CONTACT.
ALL WOOD IN CONTACT WITH THE GROUND SHALL BE APPROVED
PRESSURE-PRESERVATIVE-TREATED WOOD SUITABLE FOR GROUND CONTACT USE
317.3 FASTENERS.
FASTENERS FOR PRESSURE PRESERVATIVE AND FIRE-RETARDANT-TREATED WOOD SHALL BE
OF HOT-DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER.
EXCEPTION:
1. ONE-HALF-INCH DIAMETER OR GREATER STEEL BOLTS.
2. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED
TO BE OF MECHANICALLY DEPOSITED ZINC COATED STEEL WITH COATING
WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM
R601.1 APPLICATION.
WALL CONSTRUCTION SHALL BE IN ACCORDANCE TO THE PROVISIONS SET FORTH IN
CHAPTER 6 OF THE IRC.
R601.2 REQUIREMENTS.
FOR WALL CONSTRUCTION LOADING, SEE SECTION R301.
R602.3. DESIGN & CONSTRUCTION
SEE TABLE R602.3(1)ON THIS SHEET FOR FASTENER / NAILING SCHEDULE
403.1 GENERAL.
ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUS SOLID OR FULLY GROUTED
MASONRY OR CONCRETE FOOTINGS, WOOD FOUNDATIONS, OR OTHER APPROVED
STRUCTURAL SYSTEMS, WHICH SHALL BE OF SUFFICIENT DESIGN TO ACCOMMODATE ALL
LOADS ACCORDING TO SECTION R301 AND BE CONSTRUCTED IN ACCORDANCE WITH THE
PROVISIONS OF SECTION R403, OF THE IRC . FOOTINGS SHALL BE SUPPORTED ON
UNDISTURBED NATURAL SOILS OR ENGINEERED FILL.
403.1.4.1 FROST PROTECTION.
FOUNDATION WALLS, PIERS AND OTHER PERMANENT SUPPORTS OF BUILDINGS AND
STRUCTURES SHALL BE PROTECTED FROM FROST BY EXTENDING FOOTINGS BELOW THE
FROST LINE AS SPECIFIED IN TABLE R301.2(1);...
EXCEPTION: DECKS NOT SUPPORTED BY A DWELLING NEED NOT BE PROVIDED WITH
FOOTINGS THAT EXTEND BELOW THE FROST LINE.
403.1.6 FOUNDATION ANCHORAGE.
WHEN BRACED WALL PANELS ARE SUPPORTED DIRECTLY ON CONTINUOUS FOUNDATIONS,
THE WALL WOOD SILL PLATE SHALL BE ANCHORED TO THE FOUNDATION IN ACCORDANCE
WITH SECTION 403.1.6, OF THE IRC.
• SILL PLATE SHALL BE ANCHORED TO THE FOUNDATION WITH ANCHOR BOLTS
SPACED A MAXIMUM OF 6 FEET ON CENTER. THERE SHALL BE A MINIMUM OF TWO
BOLTS PER PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12 INCHES
FROM EACH END OF THE PLATE SECTION.
• BOLTS SHALL BE AT LEAST 1/2 INCH IN DIAMETER AND SHALL EXTEND A MINIMUM
OF 7 INCHES INTO MASONRY OR CONCRETE.
• SILLS AND SOLE PLATES SHALL BE PROTECTED AGAINST DECAY AND TERMITES
WHERE REQUIRED BY SECTIONS R318 AND R319, OF THE IRC.
EXCEPTION: FOUNDATION ANCHOR STRAPS, SPACED AS REQUIRED TO PROVIDE
EQUIVALENT ANCHORAGE TO 1/2-INCH-DIAMETER ANCHOR BOLTS.
403.1.6.1 FOUNDATION ANCHORAGE IN SEISMIC DESIGN CATEGORIES D0, D1, D2, AND E.
IN ADDITION TO THE REQUIREMENTS OF SECTION R403.1.6 , THE FOLLOWING
REQUIREMENTS SHALL APPLY TO WOOD LIGHT-FRAME STRUCTURES IN SEISMIC DESIGN
CATEGORIES D1 AND D2.GENERAL CONSTRUCTION SPECS. AND CODE COMPLIANCE (2015 IRC, UPC & 20015 W.S.E.C.)1. THIS COVERSHEET HAS BEEN PREPARED IN A GENERIC OUTLINE FORM FOLLOWING THE
STANDARDS SET BY THE INTERNATIONAL RESIDENTIAL CODE (IRC). NOT ALL ITEMS ARE
NECESSARILY REQUIRED TO COMPLETE THIS SPECIFIC PROJECT, COORDINATE PLANS
WITH IRC.
2. THIS SET OF WORKING DRAWINGS IS CONSIDERED A "BUILDER SET" AND DOES NOT
INCLUDE SPECIFICATIONS OR BUILDING MATERIALS LIST. THEREFORE IT IS THE
CONTRACTOR/OWNER RESPONSIBILITY TO PROVIDE AND COORDINATE SPECIFICATIONS,
INCLUDING PRODUCT SELECTION AND INSTALLATION OR ASSEMBLY. ITEMS CALLED OUT
ARE DONE SO FOR CONVENIENCE ONLY.
3. DO NOT SCALE THESE DRAWINGS FOR CRITICAL DIMENSIONS. VERIFY ALL DIMENSIONS
AND DATUM'S BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR THEIR
ACCURACY AND REPORT DISCREPANCIES / OMISSIONS TO THE ARCHITECT
IMMEDIATELY.
[B] R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA.BUILDINGS SHALL BE CONSTRUCTED
IN ACCORDANCE WITH THE PROVISIONS SET FORTH IN THE IRC. ADDITIONAL CRITERIA SHALL BE
ESTABLISHED BY THE LOCAL JURISDICTION AND SET FORTH IN TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA.
GROUND SNOW LOAD:
WIND SPEED:
SEISMIC DESIGN CATEGORY:
SUBJECT TO DAMAGE FROM:
WEATHERING:
FROST LINE DEPTH:
TERMITE:
WINTER DESIGN TEMP:
ICE SHIELD UNDERLAYMENT REQUIRED:
FLOOD HAZARDS:
AIR FREEZING INDEX:
MEAN ANNUAL TEMP:
25
PER STRUCT
MODERATE
18"
MODERATE
26
NO
175
50.5 No.DateDescription
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM7/2/2020 8:52:47 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtENERGY NOTES
19011
2020/06/05
SPM
A002
PERMIT SET909 N 29TH STREETBELLEVUE, WAMOGENERAL CONSTRUCTION SPECS. AND CODE COMPLIANCE (2015 IRC, UPC & 2015 W.S.E.C.)2015 WASHINGTON STATE ENERGY REQUIREMENTS
M1507 MECHANICAL VENTILATION
M1507.1 SOURCE SPECIFIC VENTILATION
WHERE LOCAL EXHAUST OR WHOLE-HOUSE MECHANICAL VENTILATION IS PROVIDED, THE
EQUIPMENT SHALL BE DESIGNED IN ACCORDANCE WITH THIS SECTION.
a) SEE TABLE M1507.3.3 FOR MINIMUM VENTILATION RATES.
M1507.3 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE DESIGNED IN
ACCORDANCE WITH SECTION M1507.3.1 THOUGH M1507.3.3
• 1507.3.4.2 = SONE RATING = 1.0
• 1507.3.3(1) = 105 CFM
• 1507.3.3(2) = 105 X 4 = 420 CFM/MIN
25% OPERATION
M1601 DUCT CONSTRUCTION
M1601.1 DESIGN
DUCT SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISION OF THIS
SECTION AND ACCA MANUAL D, THE APPLIANCE MANUFACTURER'S INSTALLATION
INSTRUCTIONS, OR OTHER APPROVED METHODS.
M1601.1.1 ABOVE GROUND DUCTS
a. DISCHARGE TEMP LIMIT OF 250 DEGREES FAHRENHEIT
b. LABEL WITH UL 181 AND INSTALLED TO MANUF. SPECS
c. FIELD-FABRICATED, SHOP-FABRICATED, AND FLEXIBLE DUCT CONSTRUCTION
SHALL CONFORM TO SMACNA HVAC DUCT CONSTRUCTION STANDARDS -METAL
AND FLEXIBLE EXCEPT AS ALLOWED BY TABLE M1601.1.1 GALVANIZED STEEL
SHALL CONFORM TO ASTM A 653
d. GYPSUM PERMITTED PROVIDED AIR TEMP IS LESS THAN 125 DEGREES F AND NOT
SUBJECT TO CONDENSATION
e. DUCT SYSTEMS SHALL BE CONSTRUCTED OF MATERIALS OF LESS THAN 200
FLAME SPREAD INDEX
f. STUD WALL CAVITIES, SEE 7.1-7.5
M1601.2 VIBRATION ISOLATORS
VIBRATION ISOLATORS INSTALLED BETWEEN MECHANICAL EQUIPMENT AND DUCTS SHALL
BE FABRICATED FROM APPROVED MATERIALS LIST AND SHALL NOT EXCEED 10" IN
LENGTH.
M1601.3 DUCT INSULATION MATERIALS
DUCT INSULATION MATERIALS TO CONFORM TO THE FOLLOWING:
1. DUCT COVERS AND LININGS TO MEET ASTM E 84 OR UL 723, AND ASTM E 2231
2. DUCT COVERINGS AND LININGS SHALL MEET ASTM C 411
3. REFLECTIVE DUCT INSULATION SHALL BE VISIBLE AT INTERVALS NO GREATER 36".
R-VALUE IS DETERMINED IN ACCORDANCE WITH ASTM C 1668
M1601.4 INSTALLATION
DUCT INSTALLATION SHALL COMPLY WITH SECTIONS M1601.1.1 THROUGH M1601.4.10
M1701 COMBUSTION AIR
M1701.1 SCOPE
SOLID FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH COMBUSTION AIR IN
ACCORDANCE WITH THE APPLIANCE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
METHODS OF PROVIDING COMBUSTION AIR IN THIS CHAPTER DO NOT APPLY TO
FIREPLACES, FIREPLACE STOVES AND DIRECT-VENT APPLIANCES. THE REQUIREMENTS FOR
COMBUSTION AND DILUTION AIR FOR GAS-FIRED APPLIANCES SHALL BE IN ACCORDANCE
WITH CHAPTER 24.
2015 WASHINGTON STATE / IRC EXHAUST SYSTEM
REQUIREMENTS
CHAPTER 3 GENERAL REQUIREMENTS
R301 CLIMATE ZONES
CLIMATE ZONES FROM TABLE R301.1 SHALL BE USED IN DETERMINING THE APPLICABLE
REQUIREMENTS FROM CHAPTER 4. KING, SNOHOMISH & PIERCE COUNTY –4C (MARINE)
R302 DESIGN CONDITIONS
THE INTERIOR DESIGN TEMPERATURES USED FOR HEATING AND COOLING LOAD CALCULATIONS SHALL
BE A MAXIMUM OF 72°F FOR HEATING AND MINIMUM OF 75°F FOR COOLING. THE HEATING OR
COOLING OUTDOOR DESIGN TEMPERATURES SHALL BE SELECTED FROM APPENDIX C.
CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY
R401 GENERAL
A PERMANENT CERTIFICATE SHALL BE POSTED WITHIN 36" OF THE ELECTRICAL DISTRIBUTION PANEL PER
WSEC R401.3. THE CERTIFICATE SHALL LIST THE PREDOMINANT R-VALUES OF INSULATION INSTALLED
IN OR ON CEILING/ROOF, WALLS, FOUNDATION (SLAB, BASEMENT WALL, CRAWLSPACE WALL AND/OR
FLOOR), AND DUCTS OUTSIDE THE CONDITIONED SPACES; U-FACTORS FOR FENESTRATION; AND THE
SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION. THE CERTIFICATE SHALL ALSO LIST THE
TYPE AND EFFICIENCY OF HEATING, COOLING, AND SERVICE WATER HEATING EQUIPMENT.
R402 BUILDING THERMAL ENVELOPE
THE BUILDING THERMAL ENVELOPE WILL MEET THE REQUIREMENTS OF SECTIONS R402.1.1 THROUGH
R402.1.5
VERTICAL U-FACTOR: 0.28
HORZ. U-FACTOR: 0.50
CEILING R-VALUE:R-49 OR R-38 IF VAULTED (0.026)
WOOD FRAME WALL:R-21 (0.056) + INSULATED HEADERS W/ R-10
FLOOR:R-38 (0.026)
BELOW GRADE WALL:R-21 + THERMAL BREAK (0.047)
SLAB ON GRADE:R-10 / L=24”
R402.2.1 CEILINGS WITH ATTIC SPACES
WHERE SECTION R402.1.1 WOULD REQUIRE R-49 IN THE CEILING, INSTALLING R-38 OVER 100
PERCENT F THE CEILING AREA REQUIRING INSULATION SHALL BE DEEMED TO SATISFY THE
REQUIREMENT FOR R-49 WHEREVER THE FULL HEIGHT OF UNCOMPRESSED R-38 INSULATION EXTENDS
OVER THE WALL TOP PLATE AT THE EAVES. THIS REDUCTION SHALL NOT APPLY TO THE U-FACTOR
ALTERNATIVE APPROACH IN SECTION R402.1.3 AND THE TOTAL UA ALTERNATIVE IN SECTION
R402.1.4.
R402.2.1.1 LOOSE INSULATION IN ATTIC SPACES
OPEN-BLOWN OR POURED LOOSE FILL INSULATION MAY BE USED IN ATTIC SPACES HERE THE SLOPE OF
THE CEILING IS NOT MORE THAN 3 FEET IN 12 AND THERE IS AT LEAST 30 INCHES OF CLEAR DISTANCE
FROM THE TOP OF THE BOTTOM CHORD OF HE TRUSS OR CEILING JOIST TOTHE UNDERSIDE OF THE
SHEATHING AT THE ROOF EDGE.
R402.2.3 EAVE BAFFLE
FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS, A BAFFLE SHALL BE INSTALLED ADJACENT TO
SOFFIT AND EAVE VENTS. BAFFLES SHALL MAINTAIN AN OPENING EQUAL OR GREATER THAN THE SIZE
OF THE VENT. THE BAFFLE SHALL EXTEND OVER THE TOP OF THE ATTIC INSULATION. THE BAFFLE SHALL
BE PERMITTED TO BE ANY SOLID MATERIAL.
R402.2.4 ACCESS HATCHES AND DOORS
ACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES (E.G., ATTICS AND CRAWL
SPACES) SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON
THE SURROUNDING SURFACES.
R402.2.7 FLOORS
FLOOR INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF
THE SUBFLOOR DECKING. INSULATION SUPPORTS SHALL BE INSTALLED SO SPACING IS NO MORE THAN
24-INCHES ON CENTER. FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS
BELOW THE LOWER SURFACE OF THE FLOOR INSULATION.
a. PROVIDE R-10 CONTINUOUS INSULATION UNDER HEATED SLAB ON GRADE FLOORS PER
R402.2.9.1.
b. PROVIDE CLASS I VAPOR RETARDER AT CRAWL SPACE & LAP 12" AT SEAMS AND EXTEND TO
FOUNDATION WALL.
R402.2.8 BELOW-GRADE WALLS
EXTERIOR WALL INSULATION USED ON THE EXTERIOR (COLD) SIDE OF THE WALL SHALL EXTEND FROM
THE TOP OF THE BELOW-GRADE WALL TO THE TOP OF THE FOOTING AND SHALL BE APPROVED FOR
BELOW-GRADE USE. ABOVE-GRADE INSULATION SHALL BE PROTECTED. INSULATION USED ON THE
INTERIOR (WARM) SIDE OF THE WALL SHALL EXTEND FROM THE TOP OF THE BELOW-GRADE WALL TO
THE BELOW-GRADE FLOOR LEVEL AND SHALL INCLUDE R-5 RIGID BOARD PROVIDING A THERMAL BREAK
BETWEEN THE CONCRETE WALL AND THE SLAB.
ABOVE GRADE WALLS: PROVIDE FACE STAPLED BATTS TO AVOID COMPRESSION. PROVIDE MIN
R-10 INSULATION AT WALL HEADER.(R402.1.1M)
R402.4 AIR LEAKAGE
THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE
WITH THE REQUIREMENTS OF SECTIONS R402.4.1 THROUGH R402.4.4. PROVIDE AN AIR BARRIER AND
INSULATION INSTALLATION PER TABLE R402.1.1
a. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS R402.4.1.1 AND
R402.4.1.2 PER R402.4.1 THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL
ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION.
b. THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS LISTED IN TABLE R402.4.1.1
SHALL BE INSTALLED PER R402.4.1. WHERE REQUIRED BY THE CODE OFFICIAL, AN APPROVED
THIRD PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE.
c. THE BUILDING OR DWELLING UNIT SHALL BE TESTED PER R402.4.1.2 AND VERIFIED AS HAVING
AN AIR LEAKAGE RATE OF NOT EXCEEDING 5.0 AIR CHANGES PER HOUR. TESTING SHALL BE
CONDUCTED WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G.
d. NEW WOOD-BURNING FIREPLACES SHALL HAVE TIGHT-FITTING FLUE DAMPERS AND OUTDOOR
COMBUSTION AIR PER R402.4.2
e. WINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE PER
R402.4.2
f. RECESSED LUMINARIES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE TYPE IC-
RATED AND CERTIFIED UNDER ASTM E283 AS HAVING AN AIR LEAKAGE RATE PER R402.4.4
R403 SYSTEMS
R403.1 AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND
COOLING SYSTEM.
a. WHERE THE PRIMARY HEATING SYSTEM IS A FORCED-AIR FURNACE, AT LEAST ONE
PROGRAMMABLE THERMOSTAT PER DWELLING UNIT SHALL BE INSTALLED PER R403.1.1
b. UNITARY AIR COOLED HEAT PUMPS SHALL INCLUDE CONTROLS PER R403.1.2
R403.3 DUCTS AND AIR HANDLERS SHALL BE IN ACCORDANCE WITH SECTIONS R403.2.1 THROUGH
R403.2.3
a. DUCTS SHALL BE INSULATED TO A MINIMUM OF R-8 PER R403.3.1
b. B) DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE SEALED PER R403.3.2
c. AIR HANDLERS SHALL HAVE A MANUFACTURER'S DESIGNATION FOR AN AIR LEAKAGE IN
ACCORDANCE WITH ASHRAE 193 PER R403.3.2.1
d. PER R403.3.5, BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS.
INSTALLATION OF DUCTS IN EXTERIOR WALLS, FLOORS OR CEILINGS SHALL NOT DISPLACE
REQUIRED ENVELOPE INSULATION.
R403.4 MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105°F OR BELOW 55°F
SHALL BE INSULATED TO A MINIMUM OF R-6.
a. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE PER
R403.4.1
R403.5 ENERGY CONSERVATION MEASURES FOR SERVICE HOT WATER SYSTEMS SHALL
BE IN ACCORDANCE WITH SECTIONS R403.5.1 THROUGH R403.5.5
a. CIRCULATING HOT WATER SYSTEMS SHALL BE INSTALLED PER R403.5.1.1
b. INSULATION FOR HOT WATER PIPE SHALL HAVE A MINIMUM THERMAL RESISTANCE
(R-VALUE) OF R-3. (R403.5.3)
c. ALL ELECTRIC WATER HEATERS IN UNHEATED SPACES OR ON CONCRETE FLOORS
SHALL BE PLACED ON AN INCOMPRESSIBLE, INSULATED SURFACE WITH A
MINIMUM THERMAL RESISTANCE OF R-10. (R403.5.5)
R404 POWER AND LIGHTING SYSTEMS
R404.1 A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING
FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
a. PER R404.1.1 FUEL GAS LIGHTING SYSTEMS SHALL NOT HAVE CONTINUOUSLY
BURNING PILOT LIGHTS.
R405 SIMULATED PERFORMANCE
CRITERIA FOR COMPLIANCE USING SIMULATED ENERGY PERFORMANCE ANALYSIS SHALL
MEET THE REQUIREMENTS OF SECTION R401.2. SUCH ANALYSIS SHALL INCLUDE
HEATING, COOLING, AND SERVICE WATER HEATING ENERGY ONLY.No.DateDescription
H/C
H/C
H/C
AREA:634 SF
PERIMETER:102'-6" LF
Garage
AREA:1457 SF
PERIMETER:204'-6" LF
Lower Floor
AREA:92 SF
PERIMETER:39'-0" LF
Porch
AREA:2102 SF
PERIMETER:198'-0" LF
MainFloor
AREA:194 SF
PERIMETER:57'-6" LF
Covr'd Balcony
AREA:112 SF
PERIMETER:47'-0" LF
Covr'd Balcony
AREA:1309 SF
PERIMETER:203'-6" LF
I
HATCHING INDICATES
DROPPED JOISTS: NO
VENTS THIS SECTION
CRAWL SPACE
VENT IN RIM, TYP
AREA:61 SF
PERIMETER:94'-0" LF
1A
AREA:2305 SF
PERIMETER:200'-0" LF
2A
NOTE: SEE SHEET A501
FOR ROOF VENTING
AREA:2102 SF
PERIMETER:198'-0" LF
CEILING -FLAT
AREA:938 SF
PERIMETER:128'-0" LF
FLOOR INSUL
AREA:88 SF
PERIMETER:34'-6" LF
FLOOR INSUL
AREA:199 SF
PERIMETER:57'-6" LF
FLOOR INSUL
AREA:1458 SF
PERIMETER:204'-6" LF
FLOOR INSUL
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/16" = 1'-0"7/2/2020 8:52:56 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtENERGY/VENTING
CALCULATIONS
19011
2020/06/05
SPM
A003
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
Area Schedule (Energy/Venting Calculations)
Name Area Perimeter Level
FLOOR INSUL 1458 SF 204'-6"Level 1
FLOOR INSUL 199 SF 57'-6"Level 2
FLOOR INSUL 938 SF 128'-0"Level 2
FLOOR INSUL 88 SF 34'-6"Level 2
CEILING - FLAT 2102 SF 198'-0"T.O. PL Lvl2
ROOF VENTING SCHEDULE
NAME
GROSS
AREA
AREA CALCULATIONS EAVE/PARAPET VENTING ROOF JACKS
NET AREA
REQUIRED
VENTING
% AT
EAVES
REQUIRED
EAVE
CALCULATIONS
REQUIRED
JACKS
CALCULATIONS
LF OF VENT PROVIDED
# OF
JACKS
AREA
PROVIDED
1A 61 SF 62 SF 0.21 SF 100%0.21 SF 45 1.10 SF 0.00 SF 0 0.00 SF
2A 2305 SF 2305 SF 7.68 SF 50%3.84 SF 200 4.91 SF 3.84 SF 12 4.17 SF
ROOF VENTING NOTES:
1. (4) 2" DIA EAVE VENTS PER BLOCK= 5.024 SQ. IN. / L.F.
(80% NET FREE AREA)
2. ROOF JACKS = 50 SQ. IN. EACH
3. INSTALL ONE LOW ROOF JACK, WITHIN 36”OF EAVE, FOR
EVERY 12 LF OF EAVE WITHIN 60”OF PROPERTY LINE.
4. MINIMUM NET AREA SHALL BE NOT LESS THAN 1 S.F. PER
150 S.F. OF ATTIC AREA OR 1 S.F. PER 300 S.F. OF ATTIC
AREA IF 80% IS IN THE SOFFIT AND 20% IS AT LEAST 3'
ABOVE THE PLATE LINE PER IRC SECTION R806.2 AND ENERGY
REQUIREMENTS.
5. AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA
MAY BE REDUCED TO 1/300 WHEN A CLASS I OR II VAPOR
BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE
CEILING.
CRAWL SPACE VENTING
NAME AREA PERIMETER
AREA CALCULATIONS VENTS REQUIRED VENTING PROVIDED
NET AREA
NET
FREE
AREA VENTING REQUIRED
VENT SIZE: 14" x 8"
VENT AT .75 EFF
TOTAL VENTS
REQUIRED
TOTAL VENTS
SHOWN
TOTAL VENTING
AREA PROVIDED
I 1309 SF203'-4"1310 SF 300 4.37 SF 0.583 7.49 12 7 SF
CRAWL SPACE VENTING NOTES:
1. THE UNCONDITIONED, UNDER-FLOOR, SPACE BETWEEN THE BOTTOM OF THE
FLOOR JOISTS AND THE EARTH UNDER ANY BUILDING SHALL HAVE VENTILATION
OPENINGS THROUGH FOUNDATION WALLS OR EXTERIOR WALLS.
2. A GROUND COVER OF SIX MIL (0.006 INCH THICK BLACK POLYETHYLENE OR
APPROVED EQUAL SHALL BE LAID OVER THE GROUND WITHIN CRAWL SPACES. THE
GROUND COVER SHALL BE OVERLAPPED SIX INCHES MINIMUM AT THE JOINTS AND
SHALL EXTEND TO THE FOUNDATION WALL.
***THE GROUND COVER MAY BE OMITTED IN CRAWL SPACES IF THE CRAWL SPACE HAS A
CONCRETE SLAB FLOOR WITH A MINIMUM THICKNESS OF TWO INCHES***
3. THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALL NOT BE LESS THAN 1
SQUARE FOOT FOR EACH 300 SQUARE FEET OF UNDER-FLOOR AREA. REQUIRED
OPENINGS SHALL BE EVENLY PLACED TO PROVIDE CROSS VENTILATION OF THE
SPACE EXCEPT ONE SIDE OF THE BUILDING SHALL BE PERMITTED TO HAVE NO
VENTILATION OPENINGS.
4. VENTILATION OPENINGS SHALL BE COVERED FOR THEIR HEIGHT AND WIDTH WITH
ANY OF THE FOLLOWING MATERIALS PROVIDED THAT THE LEAST DIMENSION OF
THE COVERING SHALL NOT EXCEED 1/4 INCH:
A. PERFORATED SHEET METAL PLATES NOT LESS THAN 0.070 INCH THICK.
B. EXPANDED SHEET METAL PLATES NOT LESS THAN 0.047 INCH THICK.
C. CAST-IRON GRILL OR GRATING.
D. EXTRUDED LOAD-BEARING BRICK VENTS.
E. HARDWARE CLOTH OF 0.035 INCH (0.89 MM) WIRE OR HEAVIER.
F. CORROSION-RESISTANT WIRE MESH, WITH THE LEAST DIMENSION BEING
1/8 INCH
SCALE:1/16" = 1'-0"1 Level 1
SCALE:1/16" = 1'-0"2 Level 2
SCALE:1/16" = 1'-0"3 CRAWL SPACE VENTING
SCALE:1/16" = 1'-0"5 ROOF VENTING -MAIN
SCALE:1/16" = 1'-0"6 ROOF VENTING -UPPER
SCALE:1/16" = 1'-0"4 T.O. PL Lvl2
SCALE:1/16" = 1'-0"7 Level 2
SCALE:1/16" = 1'-0"8 Level 1 No.DateDescription
7/2/2020 8:52:57 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvt
ASPHALT
GRAVEL
EXISTING
RESIDENCE#903
OH OH OH
POH~~APPLE CLUSTER
11' DRIPLINE RADIUS
130
1
3
0
1
32132128128
126
124
POWER
BOX
10% SLOPE
H/C H/C
ASPHALT
GRAVEL
APPLE CLUSTER
11' DRIPLINE RADIUS
130
1
3
0
1
32132128128
126
124
LOT
3
5,104 S.F.
130
1
32128
126
124
BOX
EW
S
N
EXISTING ASPHALT ROAD
PROPOSED ASPHALT APRON
EXISTING WATER SERVICE
PROPOSED CONCRETE DRIVEWAY
1° 48' 09"102.18'NE1° 48' 20"102.18'SW89° 04' 24"
49.97'
S E
89° 04' 14"
49.96'
N W20'-0"62'-0"20'-2"BUILDING PARALLEL TO FRONT PROPERTY LINE 20'-0"62'-0"20'-2"EXISTING GRADE
OUTLINE OF
PROPOSED ROOF
PROPOSED SF
RESIDENCE
GARAGE
MAIN FLOOR: 131
B.O. GAR DR: 130.5
COVERED
PORCH
OUTLINE OF PROPOSED
FOOTPRINT
OUTLINE OF PROPOSED
UPPER FLOOR
BUILDING PARALLEL TO
FRONT PROPERTY LINE
15'
AREA:2314 SF
PERIMETER:203'-0" LF
Bldg Coverage
AREA:2937 SF
PERIMETER:230'-6" LF
Roof
AREA:288 SF
PERIMETER:70'-6" LF
Concrete Drive
8.5%LOT SLOPESILT FENCE PER STD DTL #214.00ROCK CONSTRUCTION ENTRANCE PER STD DTL # 215.10STOCK PILE AREASTOCK PILE AREAGRADE PLANE: 517.25/4 = 129.31
A
129.5 B
132.5
C
128.75
D
126.5
6'-0"129
128.5
127
126
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COMAs indicated
7/2/2020 8:53:05 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtSITE PLAN &
AREA/HT
CALCULATIONS
19011
2020/06/05
SPM
A101
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
SITE COVERAGE CALCULATIONS:
TOTAL ROOFS: 2,937 SF
TOTAL DRIVES: 288 SF
% OF LOT AREA: 63.23%
MAX LOT COVERAGE: 65%
BLDG COVERAGE CALCULATIONS:
SITE AREA:
TOTAL COVERAGE: 2,315 SF
% OF LOT AREA: 45.4%
5,100 SF
MAX BLDG COVERAGE: 50%
0'20'40'160'
A.F.G....
MARK
AEC
ELEVATION
A 129.5
B 132.5
C 128.75
D 126.5
Grand total: 4517.25
SCALE:1" = 20'-0"1 SITE PLAN
SCALE:1/16" = 1'-0"A BUILDING COVERAGE
SITE AREA:5,100 SF
SCALE:1/16" = 1'-0"B IMPERVIOUS AREA
SCALE:1" = 20'-0"3 TESC PLAN
SCALE:1" = 40'-0"2 A.F.G. CALCS
NOTE: REFER TO 8.5X11 APPROVED/STAMPED
SITE PLANS FOR ADDITIONAL NOTES & DETAILS.
SHOWN HERE FOR REFERENCE ONLY No.DateDescriptionSurface Water Drainage Notes and Specifications
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN
REVIEWER.
2.All construction shall be in accordance with the 1996 Standard Specifications for Road, Bridge and Municipal Construction prepared by WSDOT and the
American Public Works Association (APWA), as amended by the City of Renton Public Works Department.
3.The surface water drainage system shall be constructed according to the approved plans, which are on file in the Public Works Department. Any deviation from
the approved plans will require written approval from the City of Renton Public Works Department, Surface Water Utility Section.
4.A copy of these approved plans must be on the job site whenever construction is in progress.
5.Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for Horizontal Control shall be North American Datum 1983/1991
Meters unless otherwise approved by the City of Renton Public Works Department. Reference benchmark and elevations are noted on the plans.
6.All sedimentation/erosion facilities must be in operation prior to clearing and building construction, and they must be satisfactorily maintained until construction
is completed and the potential for on-site erosion has passed.
7.All retention/detention facilities must be installed and in operation prior to or in conjunction with all construction activity unless otherwise approved by the
Public Works Department, Surface Water Utility Section.
8.Grass seed may be applied by hydroseeding. The grass seed mixture, other than City of Renton approved standard mixes, shall be submitted by a Landscape
Architect and approved by the Public Works Department, Surface Water Utility Section.
9.All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with Section 7-02.3(1) of the current State of Washington Standard
Specification for Road and Bridge Construction. This shall include necessary leveling of the trench bottom or the top of the foundation material, as well as placement
and compaction of required bedding material, to uniform grade so that the entire length of the pipe will be supported on a uniformly dense, unyielding base. All pipe
bedding shall be APWA Class “C”, with the exception of PVC pipe. All trench backfill shall be compacted to minimum 95% for pavement and structural fill and 90%
otherwise per ASTM D-1557-70. Pea gravel bedding shall be 6 inches over and under PVC pipe.
10.Galvanized steel pipe and aluminized steel pipe for all drainage facilities shall have asphalt treatment #1 or better inside and outside.
11.Structures shall not be permitted within 10 feet of the spring line of any storm drainage pipe, or 15 feet from the top of any channel bank.
12.All catch basin grates shall be depressed 0.10 feet below pavement level.
13.Open cut road crossings through existing public right of way will not be allowed unless specifically approved by City of Renton Planning/Building/Public Works
Administrator.
14.Rock for erosion protection of roadside ditches, where required, shall be of sound quarry rock placed to a depth of one (1) foot and must meet the following
specifications:
4 -8 inch rock / 40 -70% passing;
2 -4 inch rock / 30 -40% passing; and less than 2 inch rock / 10 -20% passing.
15.All building downspouts and footing drains shall be connected to the storm drainage system, unless approved by the City plan reviewer or Surface Water
Utility Section. An accurately dimensioned, certified as-built drawing of this drainage system will be submitted to the City upon completion.
16.Issuance of the building or construction permits by the City of Renton does not relieve the owner of the continuing legal obligation and/or liability connected
with storm surface water disposition. Further, the City of Renton does not accept any obligation for the proper functioning and maintenance of the system provided
during construction.
17.The Contractor shall be responsible for providing adequate safeguard, safety devices, protective equipment, flaggers, and any other needed actions to
protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contract. Any work within the
traveled right of way that may interrupt normal traffic flow shall require a traffic control plan approve by the Public Works Department, Transportation Systems Division.
All sections of the WSDOT Standard Specifications 1-07-23 Traffic Control shall apply.
18.Special drainage measures will be required if the project location is within the aquifer protection area (APA).
Erosion Control Notes
THESE NOTES SHALL APPEAR FOR ALL PROJECTS -SITE IMPROVEMENTS, SURFACE WATER UTILITY, WASTEWATER UTILITY, WATER UTILITY, AND
TRANSPORTATION PLANS:
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC
WORKS DESIGN ENGINEER.
2.All limits of clearing and areas of vegetation preservation as prescribed on the plan(s) shall be clearly flagged in the field and observed during construction.
3.All required sedimentation/erosion control facilities must be constructed and in operation prior to land clearing and/or construction to ensure that sediment
laden water does not enter the natural drainage system. All erosion and sediment facilities shall be maintained in a satisfactory condition until such time that clearing
and/or construction is complete and potential for on-site erosion has passed. The implementation, maintenance, replacement and additions to erosion/sedimentation
control systems shall be the responsibility of the permitee.
4.The erosion and sedimentation control systems depicted on this drawing are intended to be minimum requirements to meet anticipated site conditions. As
construction progresses and unexpected or seasonal conditions dictate, the permitee shall anticipate that more erosion and sedimentation control facilities will be
necessary to ensure complete siltation control on the proposed site. During the course of construction, it shall be the obligation and responsibility of the permitee to
address any new conditions that may be created by the activities and to provide additional facilities, over and above minimum requirements, as may be needed, to
protect adjacent properties and water quality of the receiving drainage system.
5.Approval of this plan is for erosion/sedimentation control only. It does not constitute an approval of storm drainage design,size nor location of pipes,
restrictors, channels, or retention facilities.
6.During the time period of October 1st through April 30th, all project distributed soil areas greater than 5,000 square feet, that are to be left un-worked for
more than 12 hours, shall be covered by mulch, sodding or plastic covering.
7.In any area which has been stripped of vegetation and where no further work is anticipated for a period 30 days or more, all disturbed areas must be
immediately stabilized with mulching, grass planting or other approved erosion control treatment applicable to the time of year. Grass seeding alone will be acceptable
only during the months of April through September, inclusive. Seeding may proceed, however, whenever it is in the interest of the permitee, but must be augmented
with mulching, netting or other treatment approved by the City of Renton, outside the specified time period.
8.For all erosion/sedimentation control ponds where the dead storage depth exceeds 6 inches, a fence is required with a minimum height of three (3) feet, 3:1
side slopes.
9.A temporary gravel construction entrance, 24 feet x 50 feet x 8 inches of 4 to 6 inch quarry spalls shall be located at all points of vehicular ingress and
egress to the construction site.
SD SDSD
SD
SD
CD
H/C
E W
S
N
Garage
114
Foyer
100
Storage
104
Bath
103
Den/Guest
101
Walk-In
102
Bdrm #3
109
Bdrm #4
112
Walk-In
113
Walk-In
108
Bath
111
Sitting
110
Lndry
105
Storage
107
FOLDING COUNTER
W/D
24" SINKOPEN TO
ABOVE
39'-11"
27'-1"12'-3"7"62'-0"6'-6"7'-4 1/2"21'-1 1/2"27'-0"39'-11"
7"39'-4"62'-0"32'-3"29'-9"1
A701
1
A701
2
A701
2
A701
Linen
106
Covr'd Porch
115 2'-0"Covr'd Patio
116
12'-2"6'-11 1/2"7'-7"12'-7 1/2"
6'-3 1/2"5'-10 1/2"1'-9 1/2"3'-5"1'-9"
112B
6'-3 3/4"6'-3 3/4"
109A111A111B
11'-0"4'-0"12'-0"5'-8 1/2"5'-3 1/2"5'-5 1/2"15'-8"12'-0"114B
114A
114A
112B
112A
111A
7'-8 1/2"4'-5 1/2"2'-4"5'-6 1/2"6'-10"4'-1 1/2"
4'-1 1/2"8'-4"4'-0"6'-6"5'-6"13'-2"4'-4 1/2"5'-5 1/2"9'-3"13'-2 1/2"4'-6 1/2"12'-0"5'-9"6'-3"10'-6"2'-8 1/2"109B
105
101C
101B
1'-6"1'-0 1/2"5 1/2"3'-6"1'-6"5'-0"1'-6"3'-6"1'-6"0"1'-6"5'-0"2'-5"16'-3"1'-11 1/2"3'-6 1/2"3'-10"329
101A
115
2'-11 1/2"3'-6 1/2"6'-7 1/2"4'-7 1/2"7'-5 1/2"
6'-7 1/2"7'-9"4'-4"6'-4"2'-3 1/2"5'-1 1/2"4'-0 1/2"5'-2 1/2"2'-4"3'-1 1/2"4'-4 1/2"6'-8"104
103B
103A
101B
101A
101C
105
106
109A
109B
187
110
111B
2650TUB/SHWRSNGL VANITYDBL VANITY2650TUB/SHWR114B
4" TRENCH DRAIN
D.S.
P-1
P-2
P-3 P-15
R @ 7 3/8"18UP
P-4
20'-0 1/2"
TANKLESS W.H.
DIRECT VENT
EXHAUST/INTAKE
?
P-19
P-18
P-17
P-17
P-17P-17SOFFIT FOR HVAC
AS REQ'D
P-5
P-5P-5
P-6
P-7
P-7
P-10
P-14P-9T
EXHAUST THRU
JOIST BAY ABOVE
DRYER VENT THRU
JOIST BAY BELOW
A/C UNIT H.B.
H/C H.B.
FP-3
CONCRETE SLAB ON GRADE SHALL BE 4" THICK STEEL TROWLED FINISH, ON 4" GRANULAR FILL. SLOPE TO, AND PROVIDE THICKENED EDGE, AT GAR DOOR. PER IRC SECTION R506CONC DRIVEWAY
PERVIOUS PAVER DRIVEWAY
GAS STUB
MIN 36" CLEARANCE
FROM OPENING
VERIFY3'-0"VERIFY3'-0"3" POWER SWEEP
100
111C
P-9
DN P-15
20
D102
5
D101
4
D101
1
A702
1
A702
D101
8
D101
8 TYP
TYP
7
D101 TYP
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/4" = 1'-0"7/2/2020 8:53:10 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtMAIN FLOOR
19011
2020/06/05
SPM
A301
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
AREA...
NAME AREA
Lower Floor 1457 SF
MainFloor 2102 SF
3559 SF
Covr'd Balcony 306 SF
Garage 634 SF
Porch 92 SF
1032 SF
4590 SF
SEE "TYPICAL BUILDING MATERIALS" LIST ON THE
ELEVATION SHEET(s).
1.SEE SHEET ________ FOR GENERAL CONSTRUCTION
SPECIFICATIONS.
3.
2.SEE BUILDING ELEVATIONS FOR WINDOW OPERATION.
GENERAL PLAN NOTES:
FOR THE SYMBOLS & LEGEND SEE SHEET ________.4.
SEE STRUCTURAL SHEETS FOR SHEARWALL
DESIGNATIONS & HOLDDOWNS AND SHEET ________
FOR SHEARWALL DETAILS/ SCHEDULE.
5.
SEE SHEET ________ FOR WINDOWS SCHEDULE &
LEGEND. SEE SHEET ________ FOR DOOR WINDOWS
AND SCHEDULE & LEGEND.
6.
KEYNOTES - FLOORPLAN
ID DESCRIPTION
P-1 GARAGE/HOUSE OCCUPANCY SEPARATION. PER IRC R302.6
a) 1/2" GYP. AT GARAGE SIDE BETWEEN RESIDENCE AND
ATTIC. b) 5/8" TYPE 'X' GYP SEPARATING HABITABLE ROOMS
ABOVE. c) 1/2" GYP. AT WALLS SUPPORTING HABITABLE
ROOMS ABOVE."
P-2 DOOR BETWEEN GARAGE AND HOUSE SHALL BE EQUIPED
WITH A SELF-CLOSING DEVICE, AND BE A MIN 1 3/8" THICK
SOLID WOOD DOOR OR 20 MIN. F.R. DOOR. PER IRC
SECTION R302.5.1
P-3 STAIR ASSEMBLY: PER IRC SECTION R311.7" a) WIDTH 36"
MIN.; HEADROOM 6'-8" MIN. b) RISER 7-3/4" MAX.; TREAD
10" MIN. c) TOP OF HANDRAIL AT 34" MIN. AND 38" MAX
ABOVE TREAD NOSING d) HANDRAIL WIDTH 1-1/4" MIN. AND
2" MAX. e) INSTALL FIRE BLOCKING IN CONCEALED SPACES
BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF
THE RUN. f) COVER USABLE SPACE UNDER STAIR WITH 1/2"
GYP."
P-4 SAFETY GLAZING PER IRC SECTION R308.4
P-5 EGRESS WINDOW PER IRC SECTION R310. PROVIDE MIN NET
CLEARANCE OF 5 SF AT GRADE FLOOR OPENINGS AND 5.7
SF ABOVE. MIN SILL HEIGHT TO BE 44" A.F.F.
P-6 IGNITERS: A) FOR GAS FIRED APPLIANCES IN GARAGE TO BE
18" MIN ABOVE TOP OF SLAB, PROVIDE (2) LAYERS OF
FLOOR SHEATHING OVER FRAMING.. PER IRC SECTION
G2408. B) HEAT-PRODUCING EQUIPMENT AND APPLIANCES
SHALL BE INSTALLED TO MAINTAIN THE REQUIRED
CLEARANCES TO COMBUSTIBLE CONSTRUCTION AS
SPECIFIED IN THE LISTING AND MANUFACTURER’S
INSTRUCTIONS. PER IRC G2408.5
P-7 COVER WALLS ADJACENT TO TUBS AND SHOWERS WITH
NONABSORBENT MATERIAL TO 72" ABOVE DRAIN INLETS. PER
IRC SECTION R307.2. FOR GROUND FLR WASTE OPENING
REQ SEE UPC NOTES ON SHT A001
P-9 7-3/4 MAX. RISER WITH 10" MIN. TREAD DEPTH. IF MORE
THAN (4) RISERS HANDRAIL REQUIRED PER IRC SECTION
R311.7.7. a) PROVIDE 36"x36" MIN. LANDING AT EXTERIOR
DOORS PER IRC SECTION R311.3
P-10PROVIDE CRAWL SPACE ACCESS, MIN. 18" X 24"
UNOBSTRUCTED ACCESS. PER IRC SECTION R408.4
P-11PROVIDE ATTIC ACCESS, MIN. 22" X 30" WITH 30" MIN.
HEADROOM AT UNOBSTRUCTED READILY ACCESSIBLE
OPENING. PER IRC SECTION R807.1
P-13FIREPLACE ASSEMBLY. PER IRC CHAPTER 10. a)
FACTORY-BUILT FIREPLACES TO BE INSTALLED PER MFR. PER
IRC SECTION R1004. b). INSTALL MASONRY FIREPLACES PER
IRC SECTION R1003. c). HEARTH SHALL CONFORM TO IRC
REQUIREMENTS.
P-14SEE SITE PLAN FOR EXTENT OF WALKS AND DRIVEWAYS.
P-1536" MIN. GUARDRAIL. AT STAIRS SLOPES AT 36" ABOVE
STAIR NOSINGS. PER SEE IRC SECTION 312
P-16B' VENT FOR MECHANICAL. 1" CLEARANCE ALL SIDES.
P-172x6 WALL FOR PLUMBING / HVAC.
P-18A PERMANENT CERTIFICATE SHALL BE POSTED WITHIN 36" OF
THE ELECTRICAL DISTRIBUTION PANEL. SEE WSEC SECTION
105 ON SHEET A001
P-193" DIA GALV BOLLARD OR EQ PER G2408.3 & M1307.3.1
Room Schedule
Name Number Area
FINISHES
COMMENTSFloor Finish Base Finish Ceiling Finish
Foyer 100 312 SF LVP
Den/Guest 101 139 SF LVP
Walk-In 102 27 SF CARPET
Bath 103 55 SF LVP
Storage 104 61 SF CARPET
Lndry 105 93 SF TILE
Linen 106 7 SF TILE
Storage 107 22 SF CARPET
Walk-In 108 31 SF CARPET
Bdrm #3 109 148 SF CARPET
Sitting 110 113 SF CARPET
Bath 111 69 SF LVP
Bdrm #4 112 158 SF CARPET
Walk-In 113 26 SF CARPET
Garage 114 613 SF CONCRETE
Covr'd Porch 115 83 SF CONCRETE
Covr'd Patio 116 37 SF CONCRETE
Level 1: 17
Hall 200 259 SF CARPET
Mstr Bdrm 201 264 SF CARPET
Walk-In 202 26 SF CARPET ROD & SHELF
Mstr Bath 203 172 SF TILE
Walk-In 204 50 SF CARPET ROD & SHELF
Closet 205 20 SF CARPET ROD & SHELF
Bdrm #2 206 134 SF CARPET
Pwdr 207 52 SF TILE
Pntry 208 26 SF HDWD (5) SHELVES
Closet 209 8 SF CARPET ROD & SHELF
Family Room 210 359 SF HDWD
Kitchen 211 291 SF HDWD
Dining 212 200 SF HDWD
Covered
Balcony
213 196 SF WP
MEMBRANE
Covered
Balcony
214 98 SF WP
MEMBRANE
Level 2: 15 No.DateDescription
Tectonic Copyright 2007Tectonic Copyright 2007Tectonic Copyright 2007 Tectonic Copyright 2007
Tectonic Copyright 2007
Tectonic Copyright 2007
SDSD
SD
CDSD
DN
DN
E W
S
N
Pwdr
207
Bdrm #2
206
Walk-In
204
Mstr Bath
203
Kitchen
211
Mstr Bdrm
201
Pntry
208
Dining
212
Family Room
210
Hall
200
Covered
Balcony
213
Covered
Balcony
214
FREE
STANDING
SOAKING TUBBUFFET OPEN TO
BELOW
39'-11"
7"20'-0"19'-4"
4'-0"6'-0"9'-4"1'-0"1'-6"32'-6"27'-0"62'-0"1
A701
1
A701
2
A701
2
A701
Walk-In
202
Closet
205
Closet
209
MONTIGO DISTINCTIONS 48
GAS FIREPLACE
LANAI 52 OUTDOOR GAS
FIREPLACE
TWILIGHT II GAS
INDOOR/OUTDOOR GAS
FIREPLACE
STACKED
W/D
R @ 7 3/8"185'-3"9'-1 1/2"7'-2"5'-5 1/2"14'-6 1/2"5'-5 1/2"5'-5 1/2"6'-0"3'-0 1/2"12'-0 1/2"5'-11 1/2"3'-1 1/2"2'-10"8'-8 1/2"3'-4"2'-7"3'-5"203C
206
207
211A
211B
212A
212B
212
210
5'-0"62'-0"6'-6"25'-9"19'-3"10'-0 1/2"5 1/2"1'-6"16'-6"9'-3"7'-2"4'-11"7'-2"EQEQ1 1/2"
2'-5"
210B
210A
200
201
214
39'-11"
8'-7"12'-6"18'-3"7"
7'-2 1/2"11'-0 1/2"
203B
203A
3'-7"4'-4"2'-8"3'-11"6'-7"
203C
203B
203A
204
14" BENCHMUD SET
SHWR
201
VERIFY22 1/2"2'-9"3'-2 1/2"6'-11"1'-0"4'-1 1/2"3"124"3"24"6"12"11"36" SINK D.W.
48" RANGE
48" HOOD
MICRO
DRAWER
9'-6 1/2"1'-0"7'-0"1'-11"7'-4"4'-5 1/2"
TYP
11"
10'-1 1/2"1'-6"4'-8 1/2"4'-9"
207B 208
209
207A
206A
206B
6'-5 1/2"7'-4"4'-5 1/2"
P-17
P-17
P-17
P-17
P-16 P-16P-15
P-3
P-13
P-13P-11P-7
P-4
P-4
P-7
P-7
P-4
MUD SET
SHWR
P-4
P-4
P-5
P-5
11"11"SLOPE .25"/FTP-13
GAS STUBPHONE/DATA/TV IN
PLUG MOLD
NOTE: +600 CFM HOOD.
PROVIDE MAKE UP AIR SYSTEM
H.V.A.C.
CHASE
H.V.A.C.
CHASE
SLOPE .25"/FT
202
SOUND
BATTS
R-21 BATTS AT
H.V.A.C. CHASE, TYP
16
D102
16
D102
20
D102
1
A702
1
A702
D101
8 TYP
SOUND BATTS
D101
8 TYP
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/4" = 1'-0"7/2/2020 8:53:15 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtUPPER FLOOR
19011
2020/06/05
SPM
A401
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
AREA...
NAME AREA
Lower Floor 1457 SF
MainFloor 2102 SF
3559 SF
Covr'd Balcony 306 SF
Garage 634 SF
Porch 92 SF
1032 SF
4590 SF
SEE "TYPICAL BUILDING MATERIALS" LIST ON THE
ELEVATION SHEET(s).
1.SEE SHEET ________ FOR GENERAL CONSTRUCTION
SPECIFICATIONS.
3.
2.SEE BUILDING ELEVATIONS FOR WINDOW OPERATION.
GENERAL PLAN NOTES:
FOR THE SYMBOLS & LEGEND SEE SHEET ________.4.
SEE STRUCTURAL SHEETS FOR SHEARWALL
DESIGNATIONS & HOLDDOWNS AND SHEET ________
FOR SHEARWALL DETAILS/ SCHEDULE.
5.
SEE SHEET ________ FOR WINDOWS SCHEDULE &
LEGEND. SEE SHEET ________ FOR DOOR WINDOWS
AND SCHEDULE & LEGEND.
6.
KEYNOTES - FLOORPLAN
ID DESCRIPTION
P-1 GARAGE/HOUSE OCCUPANCY SEPARATION. PER IRC R302.6
a) 1/2" GYP. AT GARAGE SIDE BETWEEN RESIDENCE AND
ATTIC. b) 5/8" TYPE 'X' GYP SEPARATING HABITABLE ROOMS
ABOVE. c) 1/2" GYP. AT WALLS SUPPORTING HABITABLE
ROOMS ABOVE."
P-2 DOOR BETWEEN GARAGE AND HOUSE SHALL BE EQUIPED
WITH A SELF-CLOSING DEVICE, AND BE A MIN 1 3/8" THICK
SOLID WOOD DOOR OR 20 MIN. F.R. DOOR. PER IRC
SECTION R302.5.1
P-3 STAIR ASSEMBLY: PER IRC SECTION R311.7" a) WIDTH 36"
MIN.; HEADROOM 6'-8" MIN. b) RISER 7-3/4" MAX.; TREAD
10" MIN. c) TOP OF HANDRAIL AT 34" MIN. AND 38" MAX
ABOVE TREAD NOSING d) HANDRAIL WIDTH 1-1/4" MIN. AND
2" MAX. e) INSTALL FIRE BLOCKING IN CONCEALED SPACES
BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF
THE RUN. f) COVER USABLE SPACE UNDER STAIR WITH 1/2"
GYP."
P-4 SAFETY GLAZING PER IRC SECTION R308.4
P-5 EGRESS WINDOW PER IRC SECTION R310. PROVIDE MIN NET
CLEARANCE OF 5 SF AT GRADE FLOOR OPENINGS AND 5.7
SF ABOVE. MIN SILL HEIGHT TO BE 44" A.F.F.
P-6 IGNITERS: A) FOR GAS FIRED APPLIANCES IN GARAGE TO BE
18" MIN ABOVE TOP OF SLAB, PROVIDE (2) LAYERS OF
FLOOR SHEATHING OVER FRAMING.. PER IRC SECTION
G2408. B) HEAT-PRODUCING EQUIPMENT AND APPLIANCES
SHALL BE INSTALLED TO MAINTAIN THE REQUIRED
CLEARANCES TO COMBUSTIBLE CONSTRUCTION AS
SPECIFIED IN THE LISTING AND MANUFACTURER’S
INSTRUCTIONS. PER IRC G2408.5
P-7 COVER WALLS ADJACENT TO TUBS AND SHOWERS WITH
NONABSORBENT MATERIAL TO 72" ABOVE DRAIN INLETS. PER
IRC SECTION R307.2. FOR GROUND FLR WASTE OPENING
REQ SEE UPC NOTES ON SHT A001
P-9 7-3/4 MAX. RISER WITH 10" MIN. TREAD DEPTH. IF MORE
THAN (4) RISERS HANDRAIL REQUIRED PER IRC SECTION
R311.7.7. a) PROVIDE 36"x36" MIN. LANDING AT EXTERIOR
DOORS PER IRC SECTION R311.3
P-10PROVIDE CRAWL SPACE ACCESS, MIN. 18" X 24"
UNOBSTRUCTED ACCESS. PER IRC SECTION R408.4
P-11PROVIDE ATTIC ACCESS, MIN. 22" X 30" WITH 30" MIN.
HEADROOM AT UNOBSTRUCTED READILY ACCESSIBLE
OPENING. PER IRC SECTION R807.1
P-13FIREPLACE ASSEMBLY. PER IRC CHAPTER 10. a)
FACTORY-BUILT FIREPLACES TO BE INSTALLED PER MFR. PER
IRC SECTION R1004. b). INSTALL MASONRY FIREPLACES PER
IRC SECTION R1003. c). HEARTH SHALL CONFORM TO IRC
REQUIREMENTS.
P-14SEE SITE PLAN FOR EXTENT OF WALKS AND DRIVEWAYS.
P-1536" MIN. GUARDRAIL. AT STAIRS SLOPES AT 36" ABOVE
STAIR NOSINGS. PER SEE IRC SECTION 312
P-16B' VENT FOR MECHANICAL. 1" CLEARANCE ALL SIDES.
P-172x6 WALL FOR PLUMBING / HVAC.
P-18A PERMANENT CERTIFICATE SHALL BE POSTED WITHIN 36" OF
THE ELECTRICAL DISTRIBUTION PANEL. SEE WSEC SECTION
105 ON SHEET A001
P-193" DIA GALV BOLLARD OR EQ PER G2408.3 & M1307.3.1
Room Schedule
Name Number Area
FINISHES
COMMENTSFloor Finish Base Finish Ceiling Finish
Foyer 100 312 SF LVP
Den/Guest 101 139 SF LVP
Walk-In 102 27 SF CARPET
Bath 103 55 SF LVP
Storage 104 61 SF CARPET
Lndry 105 93 SF TILE
Linen 106 7 SF TILE
Storage 107 22 SF CARPET
Walk-In 108 31 SF CARPET
Bdrm #3 109 148 SF CARPET
Sitting 110 113 SF CARPET
Bath 111 69 SF LVP
Bdrm #4 112 158 SF CARPET
Walk-In 113 26 SF CARPET
Garage 114 613 SF CONCRETE
Covr'd Porch 115 83 SF CONCRETE
Covr'd Patio 116 37 SF CONCRETE
Level 1: 17
Hall 200 259 SF CARPET
Mstr Bdrm 201 264 SF CARPET
Walk-In 202 26 SF CARPET ROD & SHELF
Mstr Bath 203 172 SF TILE
Walk-In 204 50 SF CARPET ROD & SHELF
Closet 205 20 SF CARPET ROD & SHELF
Bdrm #2 206 134 SF CARPET
Pwdr 207 52 SF TILE
Pntry 208 26 SF HDWD (5) SHELVES
Closet 209 8 SF CARPET ROD & SHELF
Family Room 210 359 SF HDWD
Kitchen 211 291 SF HDWD
Dining 212 200 SF HDWD
Covered
Balcony
213 196 SF WP
MEMBRANE
Covered
Balcony
214 98 SF WP
MEMBRANE
Level 2: 15 No.DateDescription
E W
S
N
1
A701
1
A701
2
A701
2
A701 RIDGEWOOD BAFFLE AS REQ TO
PROVIDE SAME R-VALUE
OF INSUL AS CEILING.
PROVIDE 2x4 BLK'G AT 24" o.c.
AT TRUSS DIRECTION CHANGE
TO SUPPORT DRYWALL TYP.
*NOTE*:
DESIGN ATTIC TRUSSES FOR MIN 20 LB PER
SF LOAD AT BOT CHORD (IRC 301.5)
NOTE:NO VENTING IS ALLOWED AT ROOF
OVERHANGS WITHIN 24" TO 60" OF PROPERTY
LINE PER IRC TABLE R302.1
-PROVIDE FIRE BLCK'G TO THE UNDERSIDE OF
ROOF SHTG.
-INSTALL NO EAVE VENTS WITHIN PROJECTIONS
WHERE LOW ROOF JACKS ARE LOCATED
-INSTALL ONE LOW ROOF JACK PER 15LF OF
EAVE VENTING REPLACED LOW ROOF
JACKS, TYP
MAX
3'-0"
5'-0"
5'-0"
ATTIC
ACCESS8'-0"8'-0"
FURN
EXHAUST
10" HOOD EXHAUST
6" EXHAUST
FANS, TYP.RIDGERIDGERIDGE
RIDGE HIPHIPVALLEYHIPVALLEYHIPHIPHIPHIPHIPVALLEYVALLEYHIPHIP2'-0"2'-0"CANT BM PER STRUCT6'-6"FR-8
FR-6
SEE STRUCTURAL SET FOR
TRUSS LAYOUT AND FRAMING
ROOF LINE BELOW
DOWNSPOUT, TYP
1
A702
1
A702
WOOD SOFFIT
WOOD SOFFIT
1
D301
TYP AT EAVE
PERIMETER
U.N.O.
3
D301
3
D301
FRESH AIR
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/4" = 1'-0"7/2/2020 8:53:17 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtUPPER ROOF
PLAN
19011
2020/06/05
SPM
A501
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
SYMBOLS & LEGEND:
BEARING WALL BELOW
#
WALL ABOVE
SIMPSON OR EQUAL HANGER
(1) 2x STUD
POINT LOAD FROM ABOVE
INDICATES BEAM CALCULATION WITH INDEXED
NUMBER
(2) 2x STUD, TYP. LARGER MEMBERS AS NOTED ON PLANS
1.SEE SECTION R301, SHEET A001 FOR GENERAL DESIGN CRITERIA.
GENERAL FRAMING NOTES:
3.TRUSS DESIGN BY MANUFACTURER. TRUSS DESIGN DRAWINGS
SHALL BE PREPARED PER IRC SECTION R802.10.1 AND SHALL BE
PROVIDED TO THE BUILDING OFFICIAL AND APPROVED PRIOR TO
INSTALLATION.
* TRUSS DESIGN PER IRC SECTION R802.10.2
* FIELD ALTERATIONS MUST BE DESIGNED BY MFR. PER IRC
SECTION R802.10.4
* SEE SECTION R301 SHT A002 FOR DESIGN LOADS.
* TRUSS MFR TO PROVIDE ADEQUATE BEARING AREA TO RESOLVE
REACTION (PERPENDICULAR TO GRAIN) AT ALL HIGHLY LOADED
GIRDER TRUSSES.
4.PROVIDE 2x4 RAFTER/TRUSS TAIL -TYP. U.N.O.
5.ROOF PITCH: EXTERIOR PER ELEVATIONS & INTERIOR PER SECTIONS.
6.ROOF FRAMING SPACING, 24" o.c. U.N.O.
7.SEE ELEVATIONS AND/OR SECTIONS FOR ROOF PITCH,PLATE HEIGHT
AND HEADER HEIGHT.
FASTENERS: ALL FRAMING SHALL BE NAILED IN ACCORDANCE WITH TABLE
R602.3(1) OF THE IRC. SEE SHEET A001
* POSITIVE CONNECTIONS SHALL BE PROVIDED WHERE POSTS AND
BEAM OR GIRDER CONSTRUCTION IS USED TO SUPPORT FLOOR FRAMING.
2.SEE STRUCTURAL SHEETS FOR FOR SHEARWALL DESIGNATIONS &
HOLDDOWNS AND SHEET FOR SHEARWALL DETAILS/ SCHEDULE.
10.INSTALL 2X FIREBLOCKING PER R302.11 AS FOLLOWS:
a) IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS,
INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR
STAGGERED STUDS, AS FOLLOWS, VERT AT THE CLG AND FLR
LEVELS AND HORZ AT INTERVALS NOT EXCEEDING 10 FEET.
b) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERT AND
HORZ SPACES SUCH AS OCCUR AT SOFFITS, DROP CLGS AND COVE
CLGS.
c) IN CONCEALED SPACES BTWN STAIR STRINGERS AT THE TOP AND
BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL
COMPLY WITH SECTION R302.7.
d) AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND
WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL
TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF
COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL
NOT BE REQUIRED TO MEET THE ASTM E 136 REQUIREMENTS.
THE INTEGRITY OF ALL FIREBLOCKS SHALL BE MAINTAINED.
11.SEE SHT A002 FOR ROOF & CRAWL SPACE AREA VENTILATION
CALCULATIONS
9.
KEYNOTES - FRAMING
ID DESCRIPTION
FR-6 ATTIC SPACE VENT PER IRC R806. SEE ROOF VENT
CALCULATIONS. SEE SHEET A002
FR-8 HIGH EFFICIENCY GAS FURNACE, SIZE PER WSEC
PRESCRIPTIVE ENERGY CODE COMPLIANCE FORMS. a)
PROVIDE DUCT LEAKAGE, SEALING & TESTING PER
WSEC 502 & 503. b) THERMOSTAT PER WSEC 503.8.
c) SEE WSEC NOTES ON SHEET A001 No.DateDescription
12
4
124
Level 1
131.00
Level 2
142.05
T.O. PL Lvl2
152.05
T.O. PL Lvl1
141.00
B.O. JSTS
129.95
T.O. ROOF
159.10
A.F.G.
129.19
E W
8'-0"8'-0"10'-0"10'-0"MAX T.O. PLATE
153.196'24'MAX T.O. ROOF
159.19
22.86' (24' MAX)7.05'FINISHED GRADE EXISTING GRADE
30"DOWNSPOUT, TYP
STONE VENEER
4" HORZ SIDING w/ 'X'
FLASHING AT CORNERS
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
CEDAR T&G SIDING
114A 115
101B
214
203B
FASCIA AND GUTTER
COMP. ROOFING
PROPERTY LINEPROPERTY LINETYP
VINYL WINDOWS
Level 1131.00
Level 2
142.05
T.O. PL Lvl2
152.05
T.O. PL Lvl2
152.05
T.O. ROOF
159.10
T.O. ROOF
159.10
A.F.G.
129.19
S N
7.05'22.86'APPROX GAS
METER
APPROX ELEC SERVICE
STONE VENEER
6" HORZ SIDING
COMP. ROOFING
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
4" HORZ SIDING w/ 'X'
FLASHING AT CORNERS
STONE VENEER
TYP
Level 1131.00
Level 2
142.05
T.O. ROOF
159.10
SN
DRIVEWAY BEYOND
FINISHED GRADE
EXISTING GRADE GRADE BEYOND
COMP. ROOFING
FASCIA AND GUTTER
CEDAR T&G SIDING
STONE VENEER
VINYL WINDOWS
+36" OPEN
GUARD RAIL
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
6" HORZ SIDING
STONE VENEER
Level 1
131.00
Level 2
142.05
T.O. PL Lvl2
152.05
T.O. ROOF
159.10
A.F.G.
129.19
EW
MAX T.O. PLATE
153.19
MAX T.O. ROOF
159.19
6" HORZ SIDING
COMP. ROOFING
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
2X10 BELLYBAND
EXISTING GRADE
FINISHED GRADE
+36" OPEN
GUARD RAIL
109A 111B 111A
110
210 212B
112B
?
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COMAs indicated
7/2/2020 8:53:22 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtELEVATIONS
19011
2020/06/05
SPM
A601
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
TYPICAL BUILDING MATERIALS:
EXTERIOR WALL CONSTRUCTION
ROOF CONSTRUCTION
SOFFIT:
BUILDING PAPER:
SIDING MATERIAL:
GWB:
INSULATION:
FRAMING:
SHEATHING:
GWB:
BUILDING PAPER:
ROOFING:
INSULATION:
FRAMING:
SHEATHING:
FLOOR CONSTRUCTION
TRIM
CORNER BOARDS:
FASCIA:
WINDOW:
(WITH NO BRICK MOLD)
OUTSIDE:
INSIDE:
5/4x4 WRAP
FRAMING:
SOFFIT:
INSULATION:
SUBFLOOR:
FLOORING:
ASPHALT SHINGLES
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
PER PLANS
R-49 BLOWN-IN (R-38 VAULTED)
1/2" RESAWN PLYWOOD
5/8" GWB
PER ELEVATIONS
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
2x6 STUDS AT 16" oc U.N.O.
R-21 BATT w/ INTEGRAL VAPOR BARRIER
1/2" GWB
FINISH PER PLANS
3/4" T&G (PLYWOOD, COMPLY OR EQUAL)
PER PLANS
R-38 BATT
1/2" RESAWN PLYWOOD
2x2
X FLASHING
2x8 (PER DETAILS) U.N.O.
1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT
ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER
TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3.
SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH
AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE
EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING
LOCATIONS:
a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR
WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE
BARRIER FOR SUBSEQUENT DRAINAGE.
b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY
CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH
PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS.
c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL
COPINGS AND SILLS.
d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM.
e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A
WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION.
f. AT WALL AND ROOF INTERSECTIONS.
g. AT BUILT-IN GUTTERS.
ELEVATION NOTES:
SCALE:1/4" = 1'-0"1 NORTH ELEVATION
SCALE:1/8" = 1'-0"2 EAST ELEVATION
SCALE:1/8" = 1'-0"3 WEST ELEVATION
SCALE:1/8" = 1'-0"4 REAR ELEVATION No.DateDescription
Tectonic Copyright 2007
Level 1
131.00
Level 2
142.05
T.O. PL Lvl2
152.05
T.O. PL Lvl1
141.00
B.O. JSTS
129.95
T.O. ROOF159.10
2
A701
2
A701
?
?
?
+36" OPEN
GUARD RAIL
D102
20
BALLOON FRAMING PER
STRUCTURAL
D301
1
D301
1
D102
13
Bdrm #2
206
Hall
200
Foyer
100 Storage
104
Garage
114
Attic
Crawl Space
EXISTING GRADE
FINISHED GRADE D101
1
D101
6
D101
6
D101
1
D101
3
D101
1
D101
39'-0"Pntry
208
FURNATTIC PLATFORM
1
A702
1
A702
Level 1
131.00
Level 2
142.05
T.O. PL Lvl2152.05
T.O. PL Lvl1
141.00
B.O. JSTS
129.95
T.O. ROOF
159.10
1
A701
1
A701
Dining
212
Kitchen
211
Hall
200
Pntry
208
Hall
200
Walk-In
202
Mstr Bath
203
Garage
114Bdrm #4
112
Bath
111
?
?
D301
1 Attic
Crawl SpaceEXISTING GRADE
FINISHED GRADE
D101
1 D101
1
D301
1
D102
14
+2X6 FRAMING AT
DROPPED
SOFFITTYP
D101
2 D101
3
?
FURN
D301
3
D102
13
OR
D101
10 OPTIONAL AS SITE
CONDITIONS REQUIRE
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/4" = 1'-0"7/2/2020 8:53:28 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtSECTIONS
19011
2020/06/05
SPM
A701
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
TYPICAL BUILDING MATERIALS:
EXTERIOR WALL CONSTRUCTION
ROOF CONSTRUCTION
SOFFIT:
BUILDING PAPER:
SIDING MATERIAL:
GWB:
INSULATION:
FRAMING:
SHEATHING:
GWB:
BUILDING PAPER:
ROOFING:
INSULATION:
FRAMING:
SHEATHING:
FLOOR CONSTRUCTION
TRIM
CORNER BOARDS:
FASCIA:
WINDOW:
(WITH NO BRICK MOLD)
OUTSIDE:
INSIDE:
5/4x4 WRAP
FRAMING:
SOFFIT:
INSULATION:
SUBFLOOR:
FLOORING:
ASPHALT SHINGLES
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
PER PLANS
R-49 BLOWN-IN (R-38 VAULTED)
1/2" RESAWN PLYWOOD
5/8" GWB
PER ELEVATIONS
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
2x6 STUDS AT 16" oc U.N.O.
R-21 BATT w/ INTEGRAL VAPOR BARRIER
1/2" GWB
FINISH PER PLANS
3/4" T&G (PLYWOOD, COMPLY OR EQUAL)
PER PLANS
R-38 BATT
1/2" RESAWN PLYWOOD
2x2
X FLASHING
2x8 (PER DETAILS) U.N.O.
SCALE:1/4" = 1'-0"1 BUILDING SECTION E/W
SCALE:1/4" = 1'-0"2 BUILDING SECTION N/S
CONCRETE DRIVEWAY PERVIOUS PAVERSEXISTING GRADE No.DateDescription
Tectonic Copyright 2007
Level 1131.00
Level 2
142.05
T.O. PL Lvl2
152.05
T.O. PL Lvl1141.00
B.O. JSTS
129.95
T.O. ROOF
159.10
SN
1
A701
1
A701
Mstr Bdrm
201
Covered
Balcony
214
Den/Guest
101
Walk-In
102
Bath
103
Foyer
100
Lndry
105Storage
104
Walk-In
108
Bdrm #3
109
Covered
Balcony
213
Family Room
210
Hall
200
CRAWL SPACE
6 MIL V.B.
?
ATTIC
FURNACE
PLATFORM BEYOND
?
??2X12 DF#2 PER STRUCT 2X12 DF#2 PER STRUCT
D301
1
D102
12
D102
15D102
12
D102
15SIM
+36" OPEN
GUARD RAIL
23"13"3'-0"D102
16
D102
16
D101
9 TYPD101
1
D101
3
D101
1
D101
2
D301
1
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM1/4" = 1'-0"7/2/2020 8:53:32 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtSECTIONS
19011
2020/06/05
SPM
A702
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
TYPICAL BUILDING MATERIALS:
EXTERIOR WALL CONSTRUCTION
ROOF CONSTRUCTION
SOFFIT:
BUILDING PAPER:
SIDING MATERIAL:
GWB:
INSULATION:
FRAMING:
SHEATHING:
GWB:
BUILDING PAPER:
ROOFING:
INSULATION:
FRAMING:
SHEATHING:
FLOOR CONSTRUCTION
TRIM
CORNER BOARDS:
FASCIA:
WINDOW:
(WITH NO BRICK MOLD)
OUTSIDE:
INSIDE:
5/4x4 WRAP
FRAMING:
SOFFIT:
INSULATION:
SUBFLOOR:
FLOORING:
ASPHALT SHINGLES
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
PER PLANS
R-49 BLOWN-IN (R-38 VAULTED)
1/2" RESAWN PLYWOOD
5/8" GWB
PER ELEVATIONS
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
2x6 STUDS AT 16" oc U.N.O.
R-21 BATT w/ INTEGRAL VAPOR BARRIER
1/2" GWB
FINISH PER PLANS
3/4" T&G (PLYWOOD, COMPLY OR EQUAL)
PER PLANS
R-38 BATT
1/2" RESAWN PLYWOOD
2x2
X FLASHING
2x8 (PER DETAILS) U.N.O.No.DateDescription
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM7/2/2020 8:53:34 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtSCHEDULES
19011
2020/06/05
SPM
A801
PERMIT SET909 N 29TH STREETBELLEVUE, WAMO
TYP WINDOW NOTES:
1. SEE ARCHITECTURAL FLOOR PLANS FOR WINDOW LOCATIONS AND
DESIGNATIONS. SEE ELEVATIONS & BUILDING SECTIONS FOR WINDOW HEAD/SILL
LOCATIONS.
2. ALL RESIDENTIAL WINDOWS ARE BASED UPON MILGARD VINYL WINDOWS.
EXCEPT AS NOTED.
3. ALL WINDOWS SHALL HAVE THROUGH-WINDOW AIR INLETS AS PER
WASHINGTON STATE VENTILATION CODE.
4. NOT USED.
5. ALL WINDOWS TO BE FIXED UNLESS SHOWN/NOTED OTHERWISE.
6. PROVIDE SAFETY GLAZING PER KEYNOTE P-4 AS LOCATED ON FLOOR PLANS.
7. GLAZING TO BE PER ENERGY COMPLIANCE NOTES. SEE SHEETS A000 -A002
TYP DOOR NOTES:
1. ALL RESIDENTIAL SLIDING GLASS DOORS ARE BASED ON MILGARD SERIES
VINYL SLIDING DOORS.
2. GLAZING TO BE PER ENERGY COMPLIANCE NOTES. SEE SHEETS A000 -A002.
3. PROVIDE SAFETY GLAZING PER GENERAL NOTES.
4. NOT USED.
5. PROVIDE MIN 0.20 U-VALUE AT SOLID CORE FLUSH DOORS WHERE EXPOSED
TO AMBIENT TEMPERATURE.
Door Schedule
Mark Description
SIZE
DOOR
PANEL GLAZING ROOM NAME
WIDTH HT
CONTRUCTI
ON AREA TYPE FROM ROOM TO ROOM
100 SLIDING BARN DOOR (OPTIONAL)4'-0"8'-0"Foyer Foyer
101A HINGED - SINGLE - INTERIOR 5'-0"8'-0"S.C.Glass - Clear Foyer Den/Guest
101B HINGED - SINGLE - INTERIOR - POCKET 2'-6"8'-0"S.C.NONE Foyer Den/Guest
101C HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Den/Guest Walk-In
103A HINGED - SINGLE - INTERIOR - POCKET 2'-6"8'-0"S.C.NONE Bath Foyer
103B HINGED - SINGLE - INTERIOR 1'-6"8'-0"S.C.Bath Bath
104 HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Storage Foyer
105 HINGED - SINGLE - INTERIOR 3'-0"8'-0"S.C.Foyer Lndry
106 HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Foyer Linen
109A HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Sitting Bdrm #3
109B HINGED - SINGLE - INTERIOR 3'-0"8'-0"S.C.Bdrm #3 Walk-In
110 TWO PANEL SLIDING GLASS DOOR 6'-0"8'-0"VINYL 48 SF Glass - Clear Sitting Covr'd Patio
111A HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Sitting Bath
111B HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Bath Bath
112A HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Sitting Bdrm #4
112B HINGED - SINGLE - INTERIOR 3'-0"8'-0"S.C.Bdrm #4 Walk-In
114A OVERHEAD GARAGE DOOR 16'-0"8'-0"Garage
114B HINGED - SINGLE - INTERIOR 3'-0"8'-0"S.C.Garage Foyer
115 PIVOT DOOR 5'-0"8'-0"Foyer Covr'd Porch
187 HINGED - DOUBLE - INTERIOR 5'-0"8'-0"S.C.Foyer Storage
Level 1: 20
201 HINGED - DOUBLE - INTERIOR 5'-0"8'-0"S.C.Hall Mstr Bdrm
202 HINGED - DOUBLE - INTERIOR - POCKET 4'-8"8'-0"S.C.Mstr Bath Walk-In
203A HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Mstr Bdrm Mstr Bath
203B HINGED - SINGLE - INTERIOR 1'-6"8'-0"S.C.Mstr Bath
203C HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Mstr Bath Mstr Bath
204 HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Mstr Bath Walk-In
206A HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Hall Bdrm #2
206B HINGED - DOUBLE - INTERIOR 5'-0"8'-0"S.C.Bdrm #2 Closet
207A HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Hall Pwdr
207B HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Pwdr Bdrm #2
208 HINGED - SINGLE - INTERIOR 2'-4"8'-0"S.C.Hall Pntry
209 HINGED - SINGLE - INTERIOR 2'-6"8'-0"S.C.Hall Closet
210 FOUR PANEL SLIDING GLASS DOOR 13'-0"8'-0"VINYL 104 SF Glass - Clear Family Room Covered
Balcony
212 TWO PANEL SLIDING GLASS DOOR 8'-0"8'-0"VINYL 64 SF Glass - Clear Dining Covered
Balcony
214 THREE PANEL SLIDING GLASS DOOR 10'-6"8'-0"VINYL 84 SF Glass - Clear Mstr Bdrm Covered
Balcony
Level 2: 15
Grand total: 35
Window Schedule
Mark STYLE
SIZE
TEMPERED IS EGRESS
ROOM NAME
WIDTH HT AREA FROM ROOM TO ROOM
101A Picture 5'-0"3'-0"15 SF No No Den/Guest Covr'd Porch
101B Horz Sliding Single-Vent 8'-0"6'-0"48 SF No Yes Den/Guest
101C Horz Sliding Single-Vent 8'-0"6'-0"48 SF No Yes Den/Guest
105 Horz Sliding Half-Vent 4'-0"5'-0"20 SF No Yes Lndry
109A Horz Sliding Half-Vent 6'-0"6'-0"36 SF No Yes Bdrm #3
109B Horz Sliding Dbl-Vent 8'-0"1'-6"12 SF No No Bdrm #3
111A Picture 2'-0"4'-0"8 SF Yes No Bath
111B Single Hung 2'-6"4'-0"10 SF No No Bath
111C Picture 2'-0"4'-0"8 SF No No Bath Covr'd Patio
112B Horz Sliding Half-Vent 6'-0"6'-0"36 SF No Yes Bdrm #4
114A Horz Sliding Half-Vent 6'-0"4'-0"24 SF No Yes Garage
114B Horz Sliding Half-Vent 6'-0"4'-0"24 SF No Yes Garage
329 Picture 6'-0"6'-0"36 SF Yes No Foyer
Level 1: 13
200 Horz Sliding Dbl-Vent 8'-0"6'-0"48 SF Yes Yes Hall
201 Horz Sliding Single-Vent 8'-0"6'-0"48 SF No Yes Mstr Bdrm
203A Horz Sliding Half-Vent 4'-0"6'-0"24 SF Yes Yes Mstr Bath Covered
Balcony
203B Horz Sliding Single-Vent 8'-0"6'-0"48 SF Yes Yes Mstr Bath
203C Horz Sliding Half-Vent 4'-0"4'-0"16 SF Yes Yes Mstr Bath
206 Horz Sliding Half-Vent 6'-0"6'-0"36 SF No Yes Bdrm #2
207 Horz Sliding Half-Vent 4'-0"4'-0"16 SF Yes Yes Pwdr
210A Picture 6'-0"6'-0"36 SF No No Family Room
210B Picture 6'-0"6'-0"36 SF No No Family Room
211A Horz Sliding Half-Vent 5'-0"1'-0"5 SF No No Kitchen
211B Picture 3'-0"1'-0"3 SF No No Kitchen
212A Horz Sliding Dbl-Vent 8'-0"4'-0"32 SF No Yes Dining
212B Horz Sliding Single-Vent 8'-0"6'-0"48 SF No Yes Dining
Level 2: 13
Grand total: 26 No.DateDescription
ALL REINFORCEMENT SHALL BE ACCURATELY
PLACED AND ADEQUATELY SUPPORTED PRIOR
TO CONCRETE INSPECTION. SEE SHEET A001
NOTE:
SOLID SUBSTRATE
DAMPPROOFING
TIGHTLINE
1/2" DIA. X 10" A.B. AT 4'-0" O.C. THICK
PLATE w/ MIN. 3"x3"x3/16" EXCEPT AS NOTED
ON SHEARWALL SCHEDULE PLACE AN A.B.
WITHIN 12" EA SILL END & JOINTS EMBED MIN
7". PER IRC 602.11.1
4" PERF. FT'G DRAIN w/ FILTER IN 24" GRAVEL BED
FINISHED
GRADE
FOUNDATION & REINFORCING PER
STRUCTURAL. SEE SHEET S100
UNBALANCED FILL48" MAX6" MINPER PLAN3" MIN6" MAXS602
1
PER STRUCTTREATED MUD SILL (SEE
FOUNDATION DETAILS/SHEARWALL
SCHEDULE FOR A.B. INFO.)
TYP EXTERIOR WALL CONSTRUCTION
INSULATION PER ENERGY CALCS
CONCRETE STEM
WALL PER PLANS
TYP FLOOR
CONSTRUCTION
SOLID BLOCKING AT POINT
LOAD BEARING PER PLAN
TYP FLOOR
CONSTRUCTION
FRAMING PARALLEL TO STEM WALL FRAMING PERPENDICULAR TO STEM WALL
CRAWL SPACE CRAWL SPACE
EXTERIOR-SLOPE EARTH AWAY AT
2% TO SWALE LINE -GARAGE
CONCRETE-SLOPE 2% TOWARDS
OPENINGS
FULL-WIDTH TREATED MUD SILL (SEE
FOUNDATION DETAILS/SHEARWALL
SCHEDULE FOR A.B. INFO.)
TYP. EXTERIOR WALL CONSTRUCTIONINSUL PER ENERGY
CALCS
FOUNDATION PER PLANS
TOP FLANGE HANGER
TYP FLOOR
CONSTRUCTION
TREATED MUD SILL (SEE
FOUNDATION DETAILS/SHEARWALL
SCHEDULE FOR A.B. INFO.)
TYP. EXTERIOR WALL CONSTRUCTION
INSUL (IF ANY) PER ENERGY CALCS
FOUNDATION PER PLANSTYP FLOOR
CONSTRUCTION
FRAMING PARALLEL TO STEM WALL
FRAMING PERPENDICULAR TO STEM WALL
CRAWL SPACE
CRAWL SPACE
PROVIDE (2) LAYERS OF 60 MIN
BLDG PAPER BTWN HANGER AND
CONCRETE STEM WALL
PROVIDE (2) LAYERS OF 60 MIN
BLDG PAPER BTWN JST AND
CONCRETE STEM WALL
SOLID SUBSTRATE
TYP FLOOR FRM'G PER PLAN
FOOTING PER PLAN
POST AND BEAM PER PLAN.
SEE STRUCT. PROVIDE MIN 1"
CLEARANCE FROM CONC. AT
END OF BEAMS
SOLID BLK'G o/ SUPPORT
INSUL. PER ENERGY CALCS.
CONNECTION AT CRIPPLE WALL CONNECTION AT FOOTING3" MIN.3" MIN.
CRAWL SPACE CRAWL SPACE
POSITIVE CONNECTION
PER STRUCT
CRIPPLE WALL PER PLAN
SHT'G PER
STRUCTURAL
PROVIDE 14X8 VENT
HOLES 48" O.C.
EXT. DOOR w/ THRESHOLD
FLASHING AS REQ'D.
NERVESTRAL FLASHING
CONCRETE SLAB PER PLAN
TREATED MUD SILL
#4 VERT RE-BAR
STUBBED INTO SLAB
FOUNDATION PER PLANS7.5" MAXEXT. DOOR w/ THRESHOLD
FLASHING AS REQ'D.
NERVESTRAL FLASHING
CONCRETE SLAB PER PLAN
#4 VERT RE-BAR
STUBBED INTO SLAB
TREATED MUD SILL (SEE
FNDN DETAILS/SHEARWALL
SCHEDULE FOR A.B. INFO.)
FOUNDATION PER
PLANS7.5" MAXFRAMING PARALLEL TO STEM WALL
FRAMING PERPENDICULAR TO STEM WALL
TOP FLANGE HANGER
TYP FLOOR
CONSTRUCTION
FULL-WIDTH TREATED MUD SILL (SEE
FOUNDATION DETAILS/SHEARWALL
SCHEDULE FOR A.B. INFO.)
TYP FLOOR
CONSTRUCTION
PROVIDE (2) LAYERS OF 60 MIN
BLDG PAPER BTWN HANGER AND
CONCRETE STEM WALL
PROVIDE (2) LAYERS OF 60
MIN BLDG PAPER BTWN
HANGER AND CONCRETE
STEM WALL
TREATED MUD SILL AND RIM JOIST
TYP FLOOR FRAMING PER PLAN
EXT. DOOR w/ THRESHOLD
FLASHING AS REQ'D.
NERVESTRAL FLASHING
CONCRETE SLAB PER PLAN
#4 VERT. RE-BAR
STUBBED INTO SLAB
A.B. BEYOND (PROVIDE ONE
EA. SIDE OF DOORWAY)
FOUNDATION PER PLANS7.5" MAXCONC SLAB ON
GRADE PER PLANS
TYP EXTERIOR WALL CONSTRUCTION
VARIESFOUNDATION PER PLANS
GARAGE EXTERIOR
D101
1SEE FOR FOUNDATION
NOTES/INFORMATION
POST PER PLANS
CONC PLYNTH PER
PLANS
ADJUSTABLE POST
BASE PER PLANS
FOOTING PER
STRUCTURAL
SOLID SUBSTRATE
1'-0" MIN
CONC SLAB PER
PLANS
18" MINFRAMING PARALLEL TO STEM WALL FRAMING PERPENDICULARTO STEM WALL
RIM JOIST PER PLANS
TYP FLOOR FRAMING PER PLANS
TYP EXTERIOR WALL CONSTRUCTION
CRIPPLE WALL
CONSTRUCTION PER
PLANS
DBL TOP PLATE
BOTTOM PLATE
INSUL PER ENERGY CALCS
P.T. MUD SILL. SEE
FOUNDATION DETAILS FOR
ANCHOR BOLT INFO.
FOUNDATION PER
PLANS
CRAWL
SPACE
VARIES PER GRADE6" MIN.CRAWL
SPACE
MODIFIED TWO STUD CORNER INTERIOR CORNER
2X6 BACKER FOR G.W.B.
INSUL PER
ENERGY CALCS
HOLDDOWN & ADD'L STUD(s)
PER PLAN (WHERE OCCURS)
INTERIOR PARTITION
PER PLAN
TYP EXTERIOR WALL
CONSTRUCTION
EDGE NAIL'G PER
SCHD
SHEARWALL SHT'G (IF ANY) PER
PLANS. SEE SHEARWALL SCHD
HOLDDOWN & ADD'L
STUD(s) PER PLAN
(WHERE OCCURS)
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM3/4" = 1'-0"7/2/2020 8:53:38 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtFOUNDATION &
FRAMING
DETAILS
19011
2020/06/05
SPM
D101
PERMIT SET909 N 29TH STREETBELLEVUE, WAMONOTE: THIS IS A STANDARD DETAILS SHEET PREPARED FOR SINGLE FAMILY HOUSING TYPE V NONRATED CONSTRUCTION. THESE DETAILS HAVE BEEN PREPARED TO COVER GENERAL CONSTRUCTION CONDITIONS. NOT ALL DETAILS ON THIS SHEET ARE NECESSARILY INCORPORATED INTO THIS PROJECT. COORDINATE WITH PLANS.STANDARD DETAIL SHEETSCALE:3/4" = 1'-0"1 FOUNDATION DETAIL
SCALE:3/4" = 1'-0"2 FRAMING / FNDN. CONNECTION
SCALE:3/4" = 1'-0"3 FRAMING / FNDN. CONNECTION
SCALE:3/4" = 1'-0"9 POST / FTG CONNECTION
SCALE:3/4" = 1'-0"5 EXT. DOOR THRESHOLD DETAIL
SCALE:3/4" = 1'-0"4 EXT. DOOR THRESHOLD DETAIL
SCALE:3/4" = 1'-0"6 SLAB AT STEM WALL
SCALE:3/4" = 1'-0"7 FRM'G CONNECTION @ DECK POST
SCALE:3/4" = 1'-0"10 CRIPPLE WALL AT FOUNDATION
SCALE:3/4" = 1'-0"8 INT/EXT WALL FRAMING DETAIL No.DateDescription
TYP EXTERIOR WALL CONSTRUCTION
TYP WALL CONSTRUCTION
PER PLANS
SOFFIT PER PLANS. SEE ELEVATIONS
FOR GENERAL MATERIAL LIST.
CONT 1-1/2" SOFFIT VENT
INSULATION (IF ANY)
PER ENERGY CALCS
PROVIDE SOLID BLK'G
PER STRUCTURAL
TYP FLOOR FRM'G PER
PLANS
SHEARWALL PANEL WHERE
OCCURS, SEE PLAN
SHEARWALL PANEL WHERE
OCCURS, SEE PLAN
EXTERIOR FINSH PER PLANS.
BEAM PER PLANS
RIM JOIST PER PLANS
TYP. FLOOR
FRAMING PER
PLANS
TYP EXTERIOR WALL
CONSTRUCTION
2x BACKER FOR G.W.B.
TYP EXTERIOR WALL
CONSTRUCTION
DBL TOP PLATE
INSUL PER
ENERGY CALCS
FRAMING PARALLEL TO WALL FRAMING PERPENDICULAR TO WALL
WHERE HDRS OCCUR AND ARE
NOT FULL WIDTH, PROVIDE R-10
RIGID INSUL AT THE INSIDE FACE
SHT'G PER STRUCTURAL
SHT'G PER STRUCTURAL
TYP. FLOOR FRAMING
PER PLANS
PROVIDE SOLID BLK'G
PER STRUCTURAL
PROVIDE SOLID BLK'G PER
STRUCTURAL
ALIGN JOIST
UNDER WALL
TYP. FLOOR FRAMING
PER PLANS
TYP WALL CONSTRUCTION
PER PLANS
2x BACKER FOR G.W.B.
TYP WALL CONSTRUCTION
DBL TOP PLATE
FRAMING PARALLEL TO WALL FRAMING PERPENDICULAR TO WALL
HEADER (WHERE OCCURS)
TYP. FLOOR FRAMING
PER PLANS
PROVIDE SOLID BLK'G PER
STRUCTURALPROVIDE SOLID BLK'G PER
STRUCTURAL
SOLID BLK'G UNDER WALL
SHEARWALL SHT'G (WHERE
OCCURS) PER STRUCTURAL
SHEARWALL SHT'G (WHERE
OCCURS) PER STRUCTURAL
STRAP (WHERE OCCURS) PER
STRUCTURAL
RUN
RISE3 -2x STRINGERS TYP. U.N.O. CENTER
STRINGER WITH (2) -2x4 STRONG
BACK TYP.
3/4" PLYWOOD RISER
1 1/8" HARDBOARD TREAD WITH EASED NOSING
SEE PLAN FOR TYP. RISE & RUN DIMENSIONS
1/2" G.W.B. AS REQUIRED SEE NOTES ABOVE
STAIR ASSEMBLY: PER IRC SECTION R311.5
a) WIDTH 36" MIN.; HEADROOM 6'-8" MIN.
b) RISER 7-3/4" MAX.; TREAD 10" MIN.
c) TOP OF HANDRAIL AT 34" MIN. AND 38" MAX
ABOVE TREAD NOSING
d) HANDRAIL WIDTH 1-1/4" MIN. AND 2" MAX.
e) INSTALL FIRE BLOCKING IN CONCEALED SPACES
BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM
OF THE RUN
f) COVER USABLE SPACE UNDER STAIR WITH ½" GYP.
HANDRAIL
END NAIL STAIR JACKS TO 2x THRUST BLOCK
W/ (2) EA/12d NAILS AND NAIL BLOCK DOWN
W/ (4) EA /12d NAILS
FIRST RISER OVER BEAM
SIMPSON L50
EA. SIDE, TYP.
FLR FRAMING PER PLAN
SIMPSON A35 AT EA. SIDE OR
OTHER POS. CONNECTION
(2) 2X4 STRONG BACK
BLK'G
FIRST TREAD AT BEAM
TYP EXTERIOR WALL CONSTRUCTION
TYP FLOOR FRAMING PER PLANS
TYP EXTERIOR WALL CONSTRUCTION
HNGR PER PLANS
FLASHING
RIM JOIST PER PLANS
DECK FRAMING PER PLAN
2x LEDGER PER PLANS
DECK MATERIAL PER PLANS
3" C.C. SPRAY
FOAM INSUL (R-21)
BATT INSULDECK JSTS
PER PLANS
BOTTOM MOUNTED
METAL RAILING PER
MFR.
RIM JOIST PER PLAN
2X SOLID BLK'G
(2) LAYERS PLY WD PER PLAN
W.P. MEMBRANE 4" MAX36" MIN(2) 2X BLK'G AROUND
PERIMETER
PRIMED FASCIA
3" C.C. SPRAY
FOAM INSUL
(R-21)
BATT INSUL
TYP EXTERIOR WALL
CONSTRUCTION
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM3/4" = 1'-0"7/2/2020 8:53:39 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtFRAMING
DETAILS
19011
2020/06/05
SPM
D102
PERMIT SET909 N 29TH STREETBELLEVUE, WAMONOTE: THIS IS A STANDARD DETAILS SHEET PREPARED FOR SINGLE FAMILY HOUSING TYPE V NONRATED CONSTRUCTION. THESE DETAILS HAVE BEEN PREPARED TO COVER GENERAL CONSTRUCTION CONDITIONS. NOT ALL DETAILS ON THIS SHEET ARE NECESSARILY INCORPORATED INTO THIS PROJECT. COORDINATE WITH PLANS.STANDARD DETAIL SHEETSCALE:3/4" = 1'-0"14 CANTILEVER FRM'G AT EXT. WALL
SCALE:3/4" = 1'-0"13 EXTERIOR WALL TO FLOOR JOISTS
SCALE:3/4" = 1'-0"16 INTERIOR WALL TO FLOOR JOISTS, STACKED
SCALE:3/4" = 1'-0"20 STAIR SECTION DETAIL
SCALE:3/4" = 1'-0"12 EXTERIOR WALL FRM'G CONNECTION
SCALE:3/4" = 1'-0"15 FRM'G CONNECTION @ DECK RAILING No.DateDescription
ROOF CONSTRUCTION PER PLANS
TYP. EXTERIOR WALL CONSTRUCTION
TYP. GUTTER
EXPOSED RAFTER TAIL
FASCIA PER
ELEVATION
OVERHANG PER PLAN3 1/2"PER
ELEV
INSUL. PER ENERGY CALCS.
INSUL PER
ENERGY CALCS 2"BAFFEL -EXTEND 6" ABOVE
BATT. INSUL. OR 12' ABOVE
BLOWN INSUL.6" MIN.2" MIN. CLEARANCE FOR VENTING
ATTIC 2X BLOCKING WITH (3) 2" ~ SCREENED
HOLES WHERE NOTED ON ROOF VENTING
SCHEDULE. SEE SHT A003 & A501.
PROVIDE CLIPS PER STRUCTURAL. SEE
SHEET S401.
WHERE HDRS OCCUR AND
ARE NOT FULL WIDTH,
PROVIDE R-10 RIGID
INSUL AT THE INSIDE FACE
ROOF RAFTER CONSTRUCTION PER PLANS
TYP EXTERIOR WALL CONSTRUCTION
TYP. GUTTER
EXPOSED RAFTER TAIL
FASCIA PER
ELEVATION
TYP FLOOR CONSTRUCTION
OVERHANG PER PLAN3 1/2"PER
ELEV
INSUL (IF ANY) PER ENERGY CALCS.
INSUL. PER
ENERGY CALCS.
ATTIC
2X BLOCKING WITH (3) 2" ~ SCREENED
HOLES WHERE NOTED ON ROOF VENTING
SCHEDULE. SEE SHT A003 & A501.
PROVIDE CLIPS PER STRUCTURAL. SEE
SHEET S401.
WHERE HDRS OCCUR AND
ARE NOT FULL WIDTH,
PROVIDE R-10 RIGID
INSUL AT THE INSIDE FACE
ROOF CONSTRUCTION PER PLANS
TYP. GUTTER
FASCIA PER
ELEVATION3 1/2"SOFFIT
PER
ELEV
ATTIC
OVERHANG PER PLANS
BEAM PER PLANS
2X BLOCKING WITH (3) 2" ~ SCREENED
HOLES WHERE NOTED ON ROOF VENTING
SCHEDULE. SEE SHT A003 & A501.
PROVIDE CLIPS PER STRUCTURAL. SEE
SHEET S401.
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY. 451 DUVALL AVE NE, RENTON, W A 98059206.612.8647 | WWW.ATERAHOMES.COM3/4" = 1'-0"7/2/2020 8:53:40 AMC:\Users\MiltonOrellana\MDDG\mddg - Documents\MDDG Current Projects\2019\19012 N 29th, Kennydale\05 Construction Docs\19011-05 N 29th, Kennydale.rvtROOF DETAILS
19011
2020/06/05
SPM
D301
PERMIT SET909 N 29TH STREETBELLEVUE, WAMONOTE: THIS IS A STANDARD DETAILS SHEET PREPARED FOR SINGLE FAMILY HOUSING TYPE V NONRATED CONSTRUCTION. THESE DETAILS HAVE BEEN PREPARED TO COVER GENERAL CONSTRUCTION CONDITIONS. NOT ALL DETAILS ON THIS SHEET ARE NECESSARILY INCORPORATED INTO THIS PROJECT. COORDINATE WITH PLANS.STANDARD DETAIL SHEETSCALE:3/4" = 1'-0"1 EAVE DETAIL -TRUSS
SCALE:3/4" = 1'-0"2 EAVE DETAIL -RAFTER
SCALE:3/4" = 1'-0"3 EAVE DETAIL -RAFTER No.DateDescription
.