Loading...
HomeMy WebLinkAbout404.1 DocuSign Envelope ID:345B681 D-914F-4F2D-AB59-7C 192D3B78A3 PLAN VIEW A A ' C , ... . . , --.„_ ., . VALVE BOX LID WITH EARS IN DIRECTION OF SEWER �� 2" SQUARE �� MAIN AND WORD "SEWER" r• OPERATING NUT $ — CAST INTO IT. 8 I s' INSTALL 8" THICK HMA 4-1/4" DIA. COLLAR FOR VALVES IN 1/8' MIN. THICKNESS PAVED AREAS PER STD PLAN 106 OR 6" THICK, 3'x3' CONCRETE PAD IN UNPAVED 1" DIA. STEEL I I iN,\_ AREAS. LENGTH AS REQUIRED 41/A 2 PIECE CAST IRON VALVE �y 1/8" MIN. THICKNESS BOX, RICH—SEATTLE TYPE // � 2-1/4" INSIDE MEASUREMENT Vi OR OLYMPIC FOUNDRY .1111111. / 2-1/4" DEPTH VALVE OPERATING NUT SECTION A—A EXTENSION VALVE OPERATION NUT EXTENSION NOTE: ��g' EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE TI ' \ THAN THREE (3) FEET BELOW FINISHED GRADE. 3" EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT 38.. MIN. LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. WIDTH NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, /—WHITE POST SIZED AS NOTED, AND PAINTED WITH TWO COATS OF 62" METAL PAINT. n I I� I I I I —II 1 11 24" VALVE OR MANHOLE MARKER NOTES: MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER. VALVE MARKER POST MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OR MANHOLES OUTSIDE PAVED AREAS. MARKER POST SHALL IDENTIFY VALVES OR MANHOLES AS SEWER. SEWER VALVE STD.PLAN-404.1 PUBLIC WORKS tgnedby. DEPARTMENT OPERATING EXTENSION Martin PastuchW26/2020 1 12: 4'pN•ea AND MARKER POST �Bmfg�gg4gD. DATE Publk