HomeMy WebLinkAbout404.1 DocuSign Envelope ID:345B681 D-914F-4F2D-AB59-7C 192D3B78A3
PLAN VIEW
A A
' C ,
...
. . ,
--.„_ ., . VALVE BOX LID WITH EARS
IN DIRECTION OF SEWER �� 2" SQUARE
��
MAIN AND WORD "SEWER" r• OPERATING NUT
$ — CAST INTO IT.
8
I s' INSTALL 8" THICK HMA
4-1/4" DIA.
COLLAR FOR VALVES IN 1/8' MIN. THICKNESS
PAVED AREAS PER STD PLAN
106 OR 6" THICK, 3'x3'
CONCRETE PAD IN UNPAVED 1" DIA. STEEL
I I iN,\_ AREAS. LENGTH AS REQUIRED
41/A
2 PIECE CAST IRON VALVE �y 1/8" MIN. THICKNESS
BOX, RICH—SEATTLE TYPE // � 2-1/4" INSIDE MEASUREMENT
Vi OR OLYMPIC FOUNDRY
.1111111. /
2-1/4" DEPTH
VALVE OPERATING NUT
SECTION A—A EXTENSION
VALVE OPERATION NUT EXTENSION NOTE: ��g'
EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE TI ' \
THAN THREE (3) FEET BELOW FINISHED GRADE. 3"
EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT 38.. MIN.
LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. WIDTH
NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, /—WHITE POST
SIZED AS NOTED, AND PAINTED WITH TWO COATS OF 62"
METAL PAINT. n I I�
I I I I
—II 1 11
24"
VALVE OR MANHOLE MARKER NOTES:
MARKERS SHALL BE EQUAL TO CARSONITE UTILITY
MARKER.
VALVE MARKER POST
MARKER POST TO BE USED FOR ALL MAIN LINE
VALVES OR MANHOLES OUTSIDE PAVED AREAS.
MARKER POST SHALL IDENTIFY VALVES OR
MANHOLES AS SEWER.
SEWER VALVE STD.PLAN-404.1
PUBLIC WORKS tgnedby.
DEPARTMENT OPERATING EXTENSION Martin PastuchW26/2020 1 12:
4'pN•ea AND MARKER POST �Bmfg�gg4gD. DATE
Publk