Loading...
HomeMy WebLinkAboutW-38242981. 1• i w 75 ui Q In Lu rr J z O I— z LLJ iz AMERICAN SURVEYING & ENVIRONMENTAL, LLC (ASE) CONDUCTED AN AS -BUILT SURVEY TO LOCATE ALL WATER VALVES AND HYDRANTS. AS -BUILT DRAWING REDLINE MARKUPS WERE MAINTAINED BY LASER UNDERGROUND & EARTHWORKS, INC. BY THE ON -SITE CONSTRUCTION FOREMAN AND PROVIDED TO AGE TO PREPARE THE FINAL RECORD DRAWINGS. THE RECORD DRAWINGS REFLECT THE AS -CONSTRUCTED CONDITIONS BASED ON A COMBINATION OF FIELD SURVEY DATA AND THE AS -BUILT REDLINE MARKUP DRAWINGS PROVIDED BY LASER UNDERGROUND & EARTHWORKS, INC. AND SHOULD BE FIELD VERIFIED FOR ANY FUTURE USE. ALL WATER VALVES AND HYDRANTS WERE FIELD SURVEYED IN THEIR AS -BUILT LOCATIONS AND ACCURATELY REFLECTED HEREON. r 'f=9�----------- CLOSE VALVE AND REMOVE EX. VALVE BOX. (TYPICAL FOR ' ABANDONED VALVES) CAP EX. ANlNrf3 6' GV. FEX. 8 ' SS EX. 12 SD RENTON AVE S. 3P STA. 9+7541 321T S 77H STREET = STA. 12+22.9. 5 0'LTHIGH AVE S INSTALL: 1 - 8'X8" TEE (M✓x,..9 W/ CONC THRUST BLOCK 1 - 8GV (MJI 1 - 8" PLUG (M✓) rimJ i^ PROP. 8" DI PROPOSED STORM WATER. SEE SHEET SII g+7 .S7 LT STA. 9+ 3.4,23'E S 77H STREET = STA. 12+15.$ 5.01T HIGH AVE S INSTALL: FLxFL 1 - BOW TEE (=J) W/ CONC THRUST BLOCK 1 - 8' SPOOL 2 - 8' GV (AUxM✓) -i - n' VER' nA/ nOACC On/L V PIG QTA7710IN -PER -ST STANDARD DETAIL 30016 REMOVED TESTING DETAIL 12 U I r 3(P CONNECTION DETAIL STA. 29+47 RENTON AVE S SCALE: 1 "=10' 1 - `6" SPOOL 1 - 6fi" 1014BEND (M✓xM✓) 1 - 8" x 6" REDUCER (MJx MJ) SHACKLE II%' BENDS TO EX 6" FLANGED TEE. 1--8'L££EdE— — — — 4: ) ON 7A.11DONE5 e �I nNP EX. a' SS WIF - _� 12 SD RENTON AVE S. EX. FINAL CONNECTION DETAIL NORTH :�1, iz ' • C Y� U REMOVE POLY PIG INSTALL: 81 2 - 8' SPOOL + ~ 1 - 8" SLEEVE g U S. 7TH STREE i X 10+00 — - PROPOSED SANITARY SEWER. SEE SHEET S-8. TESTING DETAIL 14 CONNECTION DETAIL ONE- CA L L RE ER PALL 1 800- 424- 55 JWILITI PRIOR dig. STA. 12+23 HIGH AVE. S. SCALE: 1 "=10' NG UTILITIES ARE SHOWN FOR ENCE ONLY. CONTRACTOR FIELD LOCATE ALL EXISTING ES A MINIMUM OF 72 HOURS TO CONSTRUCTION. ORIGINAL PLANS STAMPED Or ANDREW WE1'GANDT ON:9/19/17 REMOVE EX. BOW TEE AND GATE VALVES CONNECT TO EX. 8' D1. INSTALL: 20LFf 8" CL-52 DI 1 - bw SLEEVE BE ABANDONE CUT dt CAPE . 6wW (TYP) `PROPOSED STORM WATER SEE _� SHEET SW-J. M S. 7TH STREE i 10+00 PROPOSED SANITARY SEWER. I a SEE SHEET S-8. FINAL CONNECTION DETAIL ( b NORTH 0+05.5. 16.2'LT(W V) STA. HIGH AVE S INSTALL: 1 - 8"X8' TAPPING TEE (M✓XFL) W/ CONC THRUST BLOCK E A V E 1 - 8" GV (FLxM✓) 1 - 8" PLUG (MJ) - w VERTfa4L CROSS POLY PIG STA7101V PER STANDARD DET,."& 30016 TEMPORARY T` RUST BEOCIG;NG 'CONC DRWE Of 00 e GRASS 11 0+05.5, 16.2'LT(WV) STA. 0+16-+, 18.51T HIGH AVE S REMOVE POLY PIG STA71ON AND 2 - 8' SPOOL 1 - 8' SLEEVE EAVE "CONC TI ORWE � WF---- 00 e GRASS I 10' D WY I 10' D VhY I_ o I N cn GRA Q Do TESTING DETAIL GA9 N I PROP. 8" DI I ^ I IQ > M G R'A 00 01) i (n V1 1 � A FINAL CONNECTION DETAIL CONNECTION DETAIL STA. 0+07 HIGH AVE S SCALE: 1 "=10' NORTH P07HOLE THIS LOCA7101V BEFORE INSTALLING TEE. rPROPOSED SANITARY SEWER. I SEE SHEET S-7. MEW li'�•� GA JASI- a 1 - 8" 90' BEND (M✓xM✓) W/ CONC. THRUST BLOCK 1 - ➢" CAP /I/ /1 W1 O" BLOW OFF REMOVED TEMPORARY om• POR ARV 71 / ? ST BLOCKING G II N S` � s I � 1 rn TESTING DETAIL 15 w w S of U U) 00 r w CONNECTION DETAI STA. 7+09 S. 7TH STREET SCALE: 1 "=10' GA9 G4 PROPOSED SANITARY SEWER. SEE SHEET S-7. STA. 6+90.0, 9.0•RT S 77H STREET REMOVE EXIS77NG BLOW -OFF AND CONNECT TO EX. 8"W. INSTALL: 1 - 8" SPOOL 1 - 8" SLEEVE 1n °a I I� Io c� ' I rn ss FINAL CONNECTION DETAIL L NORTH NOTE. ALL PIPE SHALL BE BAGGED AND SEALED FROM POINT OF DELIVERY THROUGH INSTALLATION. SURVEYED: SCALE: DAIS: BRH VERTICAL: NAVD 83/1 RENTON HILL UTILITY REPLACEMENT PROJECT c/ / HORIZONTAL: NAD 191988 1 06 19 17 DESIGNED: 1 "- 1 D • rt CITY OF FIEL0900K: AW RENTON DRAWN: AW CONNECTION DETAILS PAGE: II- ONE INCH II DATUM DRAWING N0: CHECKED: AT FUI LL S LE l Plan nin Buildin Public Works Dent W-22 AW, AG IF NOT ONE INCH �/ �/ P NO. REVISION BY DATE APPR APPROVED::G SCNE ACCORDINGLY SHEET: ZO OR 88 IWI-10131812141