Loading...
HomeMy WebLinkAboutMatveyev_Final_Short_Plat_PR17-000389_LUA17-000503_C18000334 - 500-256-665.pdfMatveyev_Final_Short_Plat_PR17-000389_LUA17-000503_C18000334 11/5/2020 Attendees swarlick (swarlick@rentonwa.gov) aaskren (aaskren@rentonwa.gov) cthomas (cthomas@rentonrfa.org) aweihs (aweihs@rentonwa.gov) Documents A_Master_Application_Matveyev_200908_v1.pdf C_Conditions_Addressed_Matveyev_200908_v1.pdf CA_Density_Worksheet_Matveyev_200908_v1.pdf CA_Lot_Closures_Matveyev_200908_v1.pdf L_Declaration_of_Covenant_BMPs_Matveyev_200908_v1.pdf L_Deed_of_Dedication_Matveyev_200908_v1.pdf L_REET_Matveyev_Short_Plat_200908_v1.pdf L_Short_Plat_Certificate_Matveyev_200908_v1.pdf MAP_Final_Short_Plat_Matveyev_200908_v1.pdf P_Composite_Utility_Plan_Matveyev_200908_v1.pdf P_Landscape_Plans_Approved_Matveyev_200908_v1.pdf RS_Arborist_Report_200908_v1.pdf RS_Geotech_Report_Matveyev_200908_v1.pdf SR_Decision_Staff_ Report_And_Exhibits_Matveyev_200908_v1.pdf Record Message Date Time Document Page Label 1 swarlick: Joined Session 10/14/2020 10:02 AM 2 swarlick: Added 'A_Master_Application_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM A_Master_Application_Matveyev_200908_v1.pdf 3 swarlick: Added 'C_Conditions_Addressed_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM C_Conditions_Addressed_Matveyev_200908_v1.pdf 4 swarlick: Added 'CA_Density_Worksheet_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM CA_Density_Worksheet_Matveyev_200908_v1.pdf 5 swarlick: Added 'CA_Lot_Closures_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM CA_Lot_Closures_Matveyev_200908_v1.pdf Message Date Time Document Page Label 6 swarlick: Added 'L_Declaration_of_Covenant_BMPs_Matveyev_200908_v1.pdf' 10/14/2020 10:02 AM L_Declaration_of_Covenant_ BMPs_Matveyev_200908_v1.pdf 7 swarlick: Added 'L_Deed_of_Dedication_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM L_Deed_of_Dedication_Matveyev_200908_v1.pdf 8 swarlick: Added 'L_REET_Matveyev_Short_Plat_200908_v1.pdf'10/14/2020 10:02 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 9 swarlick: Added 'L_Short_Plat_Certificate_Matveyev_200908_v1.pdf'10/14/2020 10:02 AM L_Short_Plat_Certificate_Matveyev_200908_v1.pdf 10 swarlick: Added 'MAP_Final_Short_Plat_Matveyev_200908_v1.pdf'10/14/2020 10:03 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 11 swarlick: Added 'P_Composite_Utility_Plan_Matveyev_200908_v1.pdf'10/14/2020 10:03 AM P_Composite_Utility_Plan_Matveyev_200908_v1.pdf 12 swarlick: Added 'P_Landscape_Plans_Approved_Matveyev_200908_v1.pdf'10/14/2020 10:04 AM P_Landscape_Plans_Approved_Matveyev_200908_v1.pdf 13 swarlick: Added 'RS_Arborist_Report_200908_v1.pdf'10/14/2020 10:04 AM RS_Arborist_Report_200908_v1.pdf 14 swarlick: Added 'RS_Geotech_Report_Matveyev_200908_v1.pdf'10/14/2020 10:04 AM RS_Geotech_Report_Matveyev_200908_v1.pdf 15 swarlick: Added 'SR_Decision_Staff_ Report_And_Exhibits_Matveyev_200908_v1.pdf'10/14/2020 10:04 AM SR_Decision_Staff_ Report_And_Exhibits_Matvey ev_200908_v1.pdf 16 swarlick: Set status to Reviewing 10/14/2020 10:14 AM 17 swarlick: Left Session 10/14/2020 10:14 AM 18 aaskren: Joined Session 10/14/2020 10:33 AM 19 aaskren: Add Cloud+10/14/2020 10:43 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 2 Message Date Time Document Page Label 20 aaskren: Edited Cloud+ (Add blank line for the deed recording number to be added at time of recording) 10/14/2020 10:44 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 21 aaskren: Added Text Box 10/14/2020 10:48 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 22 aaskren: Edited Text Box (unable to determine if the existing house is to remain. if so, addresses will be:lot 1 - 3810 Park Ave N Lot 2 - 3816 Park Ave N If not, Addresses will be:Lot 1 - 3820 Park Ave N Lot 2 - 3826 Park Ave N) 10/14/2020 10:49 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 23 aaskren: Move Text Box 10/14/2020 10:49 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 24 aaskren: Add Cloud+10/14/2020 10:50 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 25 aaskren: Edited Cloud+ (uncheck this box)10/14/2020 10:50 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 26 aaskren: Add Cloud+10/14/2020 10:51 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 27 aaskren: Delete Cloud+10/14/2020 10:51 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 28 aaskren: Add Cloud+10/14/2020 10:51 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 29 aaskren: Edited Cloud+ (check spelling)10/14/2020 10:51 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 30 aaskren: Set status to Finished 10/14/2020 10:52 AM 31 aaskren: Left Session 10/14/2020 10:52 AM 32 swarlick: Joined Session 10/19/2020 9:59 AM Message Date Time Document Page Label 33 swarlick: Left Session 10/19/2020 10:00 AM 34 cthomas: Joined Session 10/26/2020 1:36 PM 35 cthomas: Set status to Reviewing 10/26/2020 1:37 PM 36 cthomas: Set status to Finished 10/26/2020 1:37 PM 37 cthomas: Left Session 10/26/2020 1:37 PM 38 swarlick: Joined Session 10/28/2020 7:42 AM 39 swarlick: Added Callout 10/28/2020 9:47 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 40 swarlick: Edited Callout (revise to say on-site BMP's)10/28/2020 9:47 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 41 swarlick: Added Callout 10/28/2020 9:49 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 42 swarlick: Added Callout 10/28/2020 9:50 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 43 swarlick: Added Callout 10/28/2020 9:51 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 44 swarlick: Edited Callout (and city of renton )10/28/2020 9:51 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 45 swarlick: Added Text Box 10/28/2020 9:54 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 46 swarlick: Edited Text Box (PUBLIC EASEMENT RESTRICTIONS/PROVISIONSAll easements within this plat [or short plat], not shown as “PRIVATE”, or otherwise noted, are hereby granted to the City of Renton, a municipal corporation, for the purpose of constructing, reconstructing, installing, repairing, replacing, enlarging, operating and maintaining utilities and utility pipelines, including, but not limited to, water, sanitary sewer, and storm drainage, together with the right of ingress and egress thereto wit 10/28/2020 9:54 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 47 swarlick: Move Text Box 10/28/2020 9:54 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 48 swarlick: Added Text Box 10/28/2020 9:55 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 49 swarlick: Added Text Box 10/28/2020 9:55 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 50 swarlick: Edited Text Box (PUBLIC ACCESS EASEMENT ENCOMPASING A PRIVATE SHARED TRACT1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract “_” for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract “_” for the purposes of utility and emergency access. ) 10/28/2020 9:56 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 51 swarlick: Edited Text Box 10/28/2020 9:56 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 52 swarlick: Delete Text Box 10/28/2020 9:56 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 53 swarlick: Move Text Box 10/28/2020 9:59 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 54 swarlick: Edited Text Box (PUBLIC ACCESS EASEMENT ENCOMPASING A PRIVATE SHARED TRACT 1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract A for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract “_” for the purposes of utility and emergency access. ) 10/28/2020 9:59 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 55 swarlick: Move Text Box 10/28/2020 9:59 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 56 swarlick: Edited Text Box (PUBLIC ACCESS EASEMENT ENCOMPASING A PRIVATE SHARED TRACT1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract A for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract A for the purposes of utility and emergency access. ) 10/28/2020 9:59 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 57 swarlick: Move Text Box 10/28/2020 10:02 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 58 swarlick: Edited Text Box (PUBLIC EASEMENT RESTRICTIONS/PROVISIONS All easements within this short plat, not shown as “PRIVATE”, or otherwise noted, are hereby granted to the City of Renton, a municipal corporation, for the purpose of constructing, reconstructing, installing, repairing, replacing, enlarging, operating and maintaining utilities and utility pipelines, including, but not limited to, water, sanitary sewer, and storm drainage, together with the right of ingress and egress thereto without prior 10/28/2020 10:04 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 59 swarlick: Edited Text Box (PUBLIC EASEMENT ENCOMPASING A PRIVATE SHARED TRACT 1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract A for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract A for the purposes of utility and emergency access. ) 10/28/2020 10:04 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 60 swarlick: Added Callout 10/28/2020 10:09 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 61 swarlick: Edited Callout (Public easement encompassing tract A ( See note on ) 10/28/2020 10:11 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 Message Date Time Document Page Label 62 swarlick: Move Text Box 10/28/2020 10:11 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 63 swarlick: Edited Callout (Public easement encompassing tract A ( See note on sheet 1)) 10/28/2020 10:11 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 64 swarlick: Move Callout 10/28/2020 10:11 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 65 swarlick: Edited Callout (Public easements encompassing tract A ( See note on sheet 1)) 10/28/2020 10:11 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 66 swarlick: Edited Text Box (PUBLIC EASEMENTs ENCOMPASING A PRIVATE SHARED TRACT1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract A for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract A for the purposes of utility and emergency access. ) 10/28/2020 10:12 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 67 swarlick: Edited Text Box (PUBLIC EASEMENTs ENCOMPASING TRACT A 1.An easement is hereby granted to Renton Regional Fire Authority, over and across Tract A for the purposes of emergency access. 2.An easement is hereby granted to the City of Renton, a municipal corporation, over, under, and across Tract A for the purposes of utility and emergency access. ) 10/28/2020 10:12 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 68 swarlick: Added Callout 10/28/2020 10:12 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 69 swarlick: Edited Callout (Show utility easement )10/28/2020 10:13 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 2 70 swarlick: Added Callout 10/28/2020 10:13 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 71 swarlick: Edited Callout (Private and public Easement Provisions ) 10/28/2020 10:13 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 72 swarlick: Added Callout 10/28/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 73 swarlick: Edited Callout (add as number 2 )10/28/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 74 swarlick: Add Leader 10/28/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 75 swarlick: Added Text Box 10/28/2020 10:24 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 76 swarlick: Edited Text Box (at final submittal )10/28/2020 10:24 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 77 swarlick: Added Text Box 10/28/2020 10:24 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 78 swarlick: Delete Text Box 10/28/2020 10:25 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 79 swarlick: Edited Text Box (At sinal submittal owner will shall sign and notarize the document and survey shall sign on) 10/28/2020 10:25 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 80 swarlick: Edited Text Box (At sinal submittal owner will shall sign and notarize the document and survey shall sign on his seal) 10/28/2020 10:25 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 81 swarlick: Edited Text Box (At sinal submittal owner will shall sign and notarize the document and survey shall sign on their seal) 10/28/2020 10:25 AM L_Deed_of_Dedication_Matveyev_200908_v1.pdf 1 82 swarlick: Edited Text Box (At final submittal owner will shall sign and notarize the document and survey shall sign on their seal) 10/28/2020 10:26 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 83 swarlick: Edited Text Box (At final submittal owner shall sign and notarize the document and survey shall sign on their seal) 10/28/2020 10:26 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 84 swarlick: Edited Text Box (At final submittal owner shall sign and notarize the document and surveyor shall sign on their seal) 10/28/2020 10:26 AM L_Deed_of_Dedication_Matve yev_200908_v1.pdf 1 85 swarlick: Move Markups 10/28/2020 10:26 AM L_Deed_of_Dedication_Matveyev_200908_v1.pdf 1 86 swarlick: Move Text Box 10/28/2020 10:26 AM L_Deed_of_Dedication_Matveyev_200908_v1.pdf 1 87 swarlick: Added Callout 10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 88 swarlick: Edited Callout (Check box )10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 89 swarlick: Move Markups 10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 90 swarlick: Edited Callout (Check box and indicate %)10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 91 swarlick: Add Leader 10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 92 swarlick: Move Callout 10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 93 swarlick: Added Text Box 10/28/2020 10:27 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 94 swarlick: Edited Text Box (None )10/28/2020 10:28 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 95 swarlick: Added Callout 10/28/2020 10:28 AM L_REET_Matveyev_Short_Plat_200908_v1.pdf 1 Message Date Time Document Page Label 96 swarlick: Edited Callout (Portion of )10/28/2020 10:28 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 97 swarlick: Added Callout 10/28/2020 10:28 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 98 swarlick: Edited Callout (Provide )10/28/2020 10:28 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 99 swarlick: Left Session 10/28/2020 12:50 PM 100 swarlick: Joined Session 11/2/2020 7:25 AM 101 swarlick: Move Markups 11/2/2020 7:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 102 swarlick: Move Text Box 11/2/2020 7:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 103 swarlick: Move Markups 11/2/2020 7:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 104 swarlick: Move Markups 11/2/2020 7:34 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 105 swarlick: Move Callout 11/2/2020 7:39 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 106 swarlick: Move Markups 11/2/2020 7:39 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 107 swarlick: Move Markups 11/2/2020 7:40 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 108 swarlick: Move Text Box 11/2/2020 7:40 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 109 swarlick: Move Markups 11/2/2020 7:40 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 110 swarlick: Edited Callout (Provide phone number)11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 Message Date Time Document Page Label 111 swarlick: Move Markups 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 112 swarlick: Move Callout 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 113 swarlick: Move Markups 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 114 swarlick: Move Callout 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 115 swarlick: Edited Callout (Should say "Portion of 334270-0510")11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 116 swarlick: Move Markups 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 117 swarlick: Move Callout 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 118 swarlick: Edited Callout ("Portion of 334270-0510")11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 119 swarlick: Move Markups 11/2/2020 7:41 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 120 swarlick: Move Callout 11/2/2020 7:42 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 121 swarlick: Move Markups 11/2/2020 7:42 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 122 swarlick: Move Markups 11/2/2020 7:42 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 123 swarlick: Move Callout 11/2/2020 7:42 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 Message Date Time Document Page Label 124 swarlick: Added Callout 11/2/2020 7:57 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 125 swarlick: Edited Callout (check this box )11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 126 swarlick: Added Callout 11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 127 swarlick: Edited Callout (Portion of 3810 Park Ave N)11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 128 swarlick: Move Markups 11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 129 swarlick: Edited Callout (Portion of 334270-0510)11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 130 swarlick: Move Markups 11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 131 swarlick: Move Callout 11/2/2020 7:58 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 132 swarlick: Added Callout 11/2/2020 7:59 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 133 swarlick: Edited Callout (Add Date)11/2/2020 7:59 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 134 swarlick: Move Markups 11/2/2020 7:59 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 135 swarlick: Added Text Box 11/2/2020 8:00 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 136 swarlick: Edited Text Box (All property owners to sign and date) 11/2/2020 8:00 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 Message Date Time Document Page Label 137 swarlick: Move Text Box 11/2/2020 8:00 AM L_REET_Matveyev_Short_Pla t_200908_v1.pdf 1 138 swarlick: Added Callout 11/2/2020 8:13 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 139 swarlick: Edited Callout (AQUIFER PROTECTION NOTICE (INCLUDE THIS NOTE IF THE LOT IS LOCATED WITHIN AQUIFER PROTECTION ZONE) The lots created herein fall within Zone _ of Renton’s aquifer protection area and are subject to the requirements of the City of Renton Ordinance #4367. ) 11/2/2020 8:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 140 swarlick: Move Markups 11/2/2020 8:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 141 swarlick: Move Callout 11/2/2020 8:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 142 swarlick: Move Markups 11/2/2020 8:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 143 swarlick: Edited Callout (AQUIFER PROTECTION NOTICE The lots created herein fall within Zone _ of Renton’s aquifer protection area and are subject to the requirements of the City of Renton Ordinance #4367. ) 11/2/2020 8:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 144 swarlick: Edited Callout (this project is outside of the aquifer protection zone ) 11/2/2020 10:07 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 145 swarlick: Move Markups 11/2/2020 10:07 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 146 swarlick: Move Callout 11/2/2020 10:07 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 Message Date Time Document Page Label 147 swarlick: Edited Callout (this project is outside of the aquifer protection zone. remove note. ) 11/2/2020 10:08 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 148 swarlick: Edited Callout (3998)11/2/2020 10:09 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 149 swarlick: Move Markups 11/2/2020 10:09 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 150 swarlick: Edited Callout (3998)11/2/2020 10:09 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 151 swarlick: Move Markups 11/2/2020 10:09 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 152 swarlick: Move Callout 11/2/2020 10:09 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 153 swarlick: Move Markups 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 154 swarlick: Move Callout 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 155 swarlick: Move Markups 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 156 swarlick: Delete Callout 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 157 swarlick: Add Leader 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 158 swarlick: Move Callout 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 159 swarlick: Move Markups 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 Message Date Time Document Page Label 160 swarlick: Move Callout 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 161 swarlick: Move Markups 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 162 swarlick: Move Text Box 11/2/2020 10:10 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 163 swarlick: Move Callout 11/2/2020 10:13 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 164 swarlick: Move Markups 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 165 swarlick: Added Callout 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 166 swarlick: Edited Callout (All building downspouts, footing drains and drains from all impervious surfaces such as patios and driveways shall be connected to the permanent storm drain outlet as shown on the approved construction drawings on file with the City of Renton (Plans No. _____) or addressed in the single family residential building permit drainage review on file with the City of Renton. All connections to the downstream drainage system shall be in compliance with City of Renton standards. All conn 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 167 swarlick: Move Markups 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 168 swarlick: Move Callout 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 169 swarlick: Move Markups 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 170 swarlick: Move Callout 11/2/2020 10:14 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 Message Date Time Document Page Label 171 swarlick: Edited Callout (All building downspouts, footing drains and drains from all impervious surfaces such as patios and driveways shall be connected to the permanent storm drain outlet as shown on the approved construction drawings on file with the City of Renton (Plans No. 3998) or addressed in the single family residential building permit drainage review on file with the City of Renton. All connections to the downstream drainage system shall be in compliance with City of Renton standards. All conne 11/2/2020 10:15 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 172 swarlick: Move Markups 11/2/2020 10:16 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 173 swarlick: Move Callout 11/2/2020 10:16 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 174 swarlick: Move Markups 11/2/2020 10:16 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 175 swarlick: Move Text Box 11/2/2020 10:17 AM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 176 swarlick: Left Session 11/2/2020 10:23 AM 177 aweihs: Joined Session 11/2/2020 1:14 PM 178 aweihs: Added Callout 11/2/2020 1:44 PM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 179 aweihs: Edited Callout (Please use consistent language with regard to tract title, i.e, Tract "a". )11/2/2020 1:45 PM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 180 aweihs: Edited Callout (Please use consistent language with regard to tract title, i.e, Private access and utility easement, Tract "a". ) 11/2/2020 1:46 PM MAP_Final_Short_Plat_Matveyev_200908_v1.pdf 1 181 aweihs: Move Callout 11/2/2020 1:46 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 182 aweihs: Edited Callout (Please use consistent language with regard to tract title, i.e, Private access and utility easement, Tract "a". Please clarify that direct access from Park Ave N is not permitted. ) 11/2/2020 1:47 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 183 aweihs: Edited Callout (Please use consistent language with regard to tract title, i.e, Private access and utility easement, Tract "a". Please clarify that direct vehicle access from Park Ave N is not permitted. ) 11/2/2020 1:48 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 184 aweihs: Added Callout 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 185 aweihs: Edited Callout (An access easement shall be recorded with the King County Recorder’s Office and be shown on the face of the plat to encumber the entirety of the tract. The easement shall prohibit any temporary or permanent physical obstructions within the easement including, but not limited to, the parking of non-emergency vehicles) 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 186 aweihs: Move Callout 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 187 aweihs: Edited Callout (An access easement shall be recorded with the King County Recorder’s Office and be shown on the face of the plat to encumber the entirety of the tract. The easement shall prohibit any temporary or permanent physical obstructions within the easement including, but not limited to, the parking of non-emergency vehicles) 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 188 aweihs: Move Callout 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 189 aweihs: Edited Callout (An access easement shall be recorded with the King County Recorder’s Office and be shown on the face of the plat to encumber the entirety of the tract. The easement shall prohibit any temporary or permanent physical obstructions within the easement including, but not limited to, the parking of non-emergency vehicles) 11/2/2020 4:18 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 190 aweihs: Added Text Box 11/2/2020 4:22 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 191 aweihs: Edited Text Box (Civil construction permit shall be inspected for compliance with approved landscape plan for ROW and shared driveway landscaping prior to recording.) 11/2/2020 4:23 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 192 aweihs: Left Session 11/2/2020 4:25 PM 193 swarlick: Joined Session 11/3/2020 6:57 AM 194 swarlick: Set status to Finished 11/3/2020 7:42 AM 195 swarlick: Left Session 11/3/2020 7:42 AM 196 aaskren: Joined Session 11/3/2020 12:22 PM 197 aaskren: Disconnected 11/3/2020 12:39 PM 198 aaskren: Disconnected 11/3/2020 12:39 PM 199 aaskren: Disconnected 11/3/2020 12:39 PM 200 aaskren: Joined Session 11/3/2020 3:23 PM 201 aaskren: Left Session 11/3/2020 3:23 PM 202 aweihs: Joined Session 11/3/2020 4:03 PM 203 aweihs: Left Session 11/3/2020 4:15 PM 204 aweihs: Joined Session 11/4/2020 11:59 AM 205 aweihs: Added Area Measurement (126.6523 sf)11/4/2020 12:01 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 206 aweihs: Move Markups 11/4/2020 12:01 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 207 aweihs: Move Area Measurement 11/4/2020 12:02 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 208 aweihs: Delete Area Measurement 11/4/2020 12:02 PM P_Landscape_Plans_Approve d_Matveyev_200908_v1.pdf 2 209 aweihs: Left Session 11/4/2020 12:03 PM 210 swarlick: Joined Session 11/5/2020 10:53 AM 211 swarlick: Added Callout 11/5/2020 11:03 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 212 swarlick: Move Text Box 11/5/2020 11:04 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 213 swarlick: Added Line 11/5/2020 11:26 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 214 swarlick: Added Callout 11/5/2020 11:27 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 215 swarlick: Edited Callout (half)11/5/2020 11:27 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 216 swarlick: Move Markups 11/5/2020 11:27 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 217 swarlick: Added Line 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 218 swarlick: Delete Line 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 219 swarlick: Added Line 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 220 swarlick: Added Text Box 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 221 swarlick: Edited Text Box (for tract a)11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 222 swarlick: Move Markups 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 223 swarlick: Move Text Box 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 224 swarlick: Move Markups 11/5/2020 11:28 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 225 swarlick: Added Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 226 swarlick: Added Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 227 swarlick: Paste 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 228 swarlick: Move Markups 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 229 swarlick: Paste 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 230 swarlick: Move Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 231 swarlick: Paste 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 232 swarlick: Move Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 233 swarlick: Paste 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 234 swarlick: Move Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 235 swarlick: Delete Line 11/5/2020 11:29 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 236 swarlick: Delete Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 237 swarlick: Move Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 238 swarlick: Move Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 239 swarlick: Move Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 240 swarlick: Move Markups 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 241 swarlick: Delete Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 242 swarlick: Added Line 11/5/2020 11:30 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 243 swarlick: Added Line 11/5/2020 11:31 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 244 swarlick: Added Line 11/5/2020 11:31 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 245 swarlick: Added Callout 11/5/2020 11:31 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 246 swarlick: Edited Callout (tract a)11/5/2020 11:31 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 247 swarlick: Move Markups 11/5/2020 11:31 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 248 swarlick: Added Line 11/5/2020 11:32 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 249 swarlick: Added Callout 11/5/2020 11:32 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 250 swarlick: Edited Callout (tract)11/5/2020 11:32 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 251 swarlick: Move Markups 11/5/2020 11:32 AM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 252 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 253 swarlick: Delete Text Box 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 254 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 255 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 256 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 257 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 258 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 259 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 260 swarlick: Delete Callout 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 261 swarlick: Delete Callout 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 262 swarlick: Delete Line 11/5/2020 12:51 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 263 swarlick: Delete Line 11/5/2020 12:52 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 264 swarlick: Move Callout 11/5/2020 12:55 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 265 swarlick: Edited Callout (Please use this language here All building downspouts, footing drains and drains from all impervious surfaces such as patios and driveways shall be connected to the permanent storm drain outlet as shown on the approved construction drawings on file with the City of Renton (Plans No. 3998) or addressed in the single family residential building permit drainage review on file with the City of Renton. All connections to the downstream drainage system shall be in compliance with City 11/5/2020 12:55 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 266 swarlick: Move Callout 11/5/2020 12:55 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 267 swarlick: Edited Callout (Please use this language here All building downspouts, footing drains and drains from all impervious surfaces such as patios and driveways shall be connected to the permanent storm drain outlet as shown on the approved construction drawings on file with the City of Renton (Plans No. 3998) or addressed in the single family residential building permit drainage review on file with the City of Renton. All connections to the downstream drainage system shall be in compliance with City 11/5/2020 12:55 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 268 swarlick: Edited Callout (Please use this language here 1. All building downspouts, footing drains and drains from all impervious surfaces such as patios and driveways shall be connected to the permanent storm drain outlet as shown on the approved construction drawings on file with the City of Renton (Plans No. 3998) or addressed in the single family residential building permit drainage review on file with the City of Renton. All connections to the downstream drainage system shall be in compliance with C 11/5/2020 12:55 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 269 swarlick: Delete Leader 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 270 swarlick: Move Callout 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 271 swarlick: Move Markups 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 272 swarlick: Move Callout 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 273 swarlick: Move Callout 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 274 swarlick: Move Markups 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 275 swarlick: Move Callout 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 276 swarlick: Move Markups 11/5/2020 12:56 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 277 swarlick: Move Callout 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 278 swarlick: Move Markups 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 279 swarlick: Move Callout 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 280 swarlick: Move Markups 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 281 swarlick: Move Callout 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 282 swarlick: Move Markups 11/5/2020 12:57 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 283 swarlick: Move Callout 11/5/2020 12:58 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 284 swarlick: Move Markups 11/5/2020 12:58 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 285 swarlick: Added Text Box 11/5/2020 12:59 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 286 swarlick: Edited Text Box (The Easement shall prohibit any temporary or permanent physical obstructions within the easement including but not limited to the parking of non emergency vehicles. ) 11/5/2020 1:04 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 287 swarlick: Move Markups 11/5/2020 1:04 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 288 swarlick: Move Callout 11/5/2020 1:04 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 289 swarlick: Move Text Box 11/5/2020 1:04 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 290 swarlick: Added Line 11/5/2020 1:05 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 291 swarlick: Added Line 11/5/2020 1:05 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 292 swarlick: Added Line 11/5/2020 1:05 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 293 swarlick: Added Line 11/5/2020 1:05 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 294 swarlick: Added Line 11/5/2020 1:05 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 Message Date Time Document Page Label 295 swarlick: Edited Text Box (The Easement shall prohibit any temporary or permanent physical obstructions within the easement including, but not limited to the parking of non emergency vehicles. ) 11/5/2020 1:07 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 296 swarlick: Edited Text Box (The Easement shall prohibit any temporary or permanent physical obstructions within the easement including, but not limited to, the parking of non emergency vehicles. ) 11/5/2020 1:08 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 297 swarlick: Delete Callout 11/5/2020 1:09 PM MAP_Final_Short_Plat_Matve yev_200908_v1.pdf 1 298 swarlick: Left Session 11/5/2020 1:15 PM 299 swarlick: Joined Session 11/5/2020 3:00 PM DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Planning Division 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 www.rentonwa.gov *By completing the email address field the owner/applicant/contact person is opting to receive all formal notifications and project documents in digital format via email unless otherwise requested. LAND USE PERMIT MASTER APPLICATION PROPERTY OWNER(S) PROJECT INFORMATION NAME: PROJECT OR DEVELOPMENT NAME: ADDRESS: PROJECT/ADDRESS(S)/LOCATION AND ZIP CODE: CITY: STATE: ZIP: PHONE NUMBER: KING COUNTY ASSESSOR’S ACCOUNT NUMBER(S): EMAIL ADDRESS*: I prefer to receive all correspondence via US Mail. APPLICANT (if other than owner)EXISTING LAND USE(S): NAME: PROPOSED LAND USE(S): COMPANY (if applicable): EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: ADDRESS: PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable) CITY: STATE: ZIP: EXISTING ZONING: PHONE NUMBER: PROPOSED ZONING (if applicable): EMAIL ADDRESS*: I prefer to receive all correspondence via US Mail. SITE AREA (in square feet): CONTACT PERSON SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS: NAME: SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE DEDICATED: COMPANY (if applicable): PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET ACRE (if applicable) ADDRESS: NUMBER OF PROPOSED LOTS (if applicable) CITY: STATE: ZIP: NUMBER OF NEW DWELLING UNITS (if applicable): PHONE NUMBER NUMBER OF EXISTING DWELLING UNITS (if applicable): EMAIL ADDRESS*: I prefer to receive all correspondence via US Mail. PROJECT VALUE: PROJECT TNFORMATTON (CONT| NUED) SQUARE FOOTAGE OF PROPOSED RESIDENTIAL BUILDINGS (if applicable): 574 SQUARE FOOTAGE OF EXISTING RESIDENTIAL BUILDINGS TO REMAIN (if applicable). p74 SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL BUILDINGS (if applicable): p74 SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL BUILDINGS TO REMAIN (if applicable): 574 NET FLOOR AREA ON NON-RESIDENTTAL BUILDtNGS (if applicable): 1174 NUMBER OF EMPLOYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable): p74 IS THE SITE LOCATED IN ANY TYPE OF ENVIRONIVENTALLY CRITICAL AREA, PLEASE INCLUDE SQUARE FOOTAGE (if applicable). n nourrrn PRoTECTToN AREA oNE E noul=n PRoTECTIoN AREA TWO N FLooD HAZARDAREA tr cEoloclc HAZARD tr HABTTAT coNSERVATtoN tl SHoRELTNE srREA[/s & LAKES E wrrmruos sq. ft. sq ft. sqft sq ft. sq. ft. LEGAL DESCRIPTION OF PROPERTY on sheet with the following information I SITUATE IN THE NW QUARTER OF SECTION 32 , TOWNSHIP OF RENTON, KING COUNTY, WASHINGTON 24 N, RANGE 05 _,W.M. lN THE CtTy AFFIDAVIT OF OWNERSHIP l, (Print Name/s)declare under penalty of pe4ury under the laws of the State of Washington that I am (please check one) [the current owner of the property involved in this application or Ithe authorized representative to act for a corporation (please attach proof of authorization) and that the foregoing statements and answers herein contained and the information herewrth are in all respects true and correct to the best of my knowledge and belief. Signature of Owner/Representative Date STATE OF WASHTNGTON J ^^)5b couNTY oF K|NG ) I certify that I know or have satisfactory evidence that signed this instrument and acknowledge it to be his/her/their free and voluntary act for the uses and in the instrument. ol' 'L - zb2-o Notary Public in and for the State of Washington F-r,-.k <,y,th Notary (Print): Myappointmentexpires: 7- Z[,- LA"Z-Z IRICK A SMITH Noiary Public Sr...te of Washington Conrmission i 199701 Dated *==a Emil Matveyev Matveyev Final Short Plat LUA17-000503 3810 Park Ave N. Confirmation of Compliance with all Conditions of Plat Approval: 1. The applicant shall submit a final detailed landscape plan that includes the required shared driveway tract landscaping, required front yard trees for Lot 2, and complies with RMC 4-8-120D.12 at the time of utility construction permit application to the current planning project manager for review and approval prior to construction permit issuance. A copy of the approved Landscape plan is included with the final short plat submittal. 2. The applicant shall submit for a demolition permit for the existing residence and all required inspections shall be completed prior to the approval of the final short plat. A demolition permit has been obtained and the house has been demolished. 3. The applicant shall submit a final detailed landscape plan showing two (2) additional trees on Lot 1 in order to meet the minimum tree density requirements of three (3) trees. Onsite landscaping shall be installed prior to final occupancy for the individual homes and landscaping within the right-of-way shall be installed prior to short plat recording. A copy of the approved Landscape plan is included with the final short plat submittal. 4. The applicant shall either request a variance from the Renton Fire Authority to allow a 16-foot wide fully paved fire apparatus access roadway, or provide a 20 foot wide paved shared access driveway for emergency vehicles. A Fire Lane Variance Request was submitted for review and addressed in the conditions of approval. The civil plans were designed and approved per the Fire Lane Variance. A note has been added to the final short plat map requiring Lot-2 future residence to be equipped with a fire sprinkler system. The note is located under Plat Conditions on Sheet 1, note 2. of the final short plat map. 5. The applicant shall record a note on the face of the plat that executes a shared maintenance agreement for equal ownership and maintenance responsibilities for improvements in Tract A. A draft version of the shared maintenance agreement shall be submitted for review and approval by the current planning project manager prior to short plat recording. A Tract Note and shared maintenance agreement note have been placed on Sheet 1 of the final short plat plan. 6. It shall be recorded on the face of the short plat that Lot 1 vehicle access shall be exclusively from the shared driveway (Tract A) and direct access to Park Ave. N shall not be permitted. . Lot 1 will have vehicle access from the new shared driveway and not from Park Ave N. A note is shown on Sheet 1 under Plat Conditions of the final short plat plan. 7. Project construction shall comply with the recommendations found in the geotechnical engineering study completed by completed by Earth Solutions NW (ESNW), LLC. (dated May 18th, 2017) for the subdivision. Construction up to date has followed the geotechnical engineering study. Completion of the construction will comply with the geotechnical study. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT DENSITY WORKSHEET Planning Division 1055 South Grady Way-Renton, WA 98057 Phone: 425-430-7200 | www.rentonwa.gov 1.Gross area of property square feet 2.Deductions: Certain areas are excluded from density calculations. These include: Public Streets* square feet Private access easements* square feet Critical Areas** square feet Total excluded area: square feet 3.Subtract line 2 (total excluded area) from line 1 for net area square feet 4.Divide line 3 by 43,560 for net acreage acres 5.Number of dwelling units or lots planned units/lots 6.Divide line 5 by line 4 for net density = dwelling units/acre *Alleys (public or private) do not have to be excluded. **Critical Areas are defined as “Areas determined by the City to be not suitable for development and which are subject to the City’s Critical Areas Regulations including very high landslide areas, protected slopes, wetlands, or floodways.” Critical Areas buffers are not deducted/excluded. 1 H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\density.doc Rev: 08/2015 Name: DEDICATION North: 194897.9851' East: 1302399.9022' Segment #1 : Line Course: N88° 46' 58.00"W Length: 6.500' North: 194898.1232' East: 1302393.4037' Segment #2 : Line Course: N01° 52' 07.00"E Length: 103.390' North: 195001.4582' East: 1302396.7750' Segment #3 : Line Course: S88° 50' 09.30"E Length: 6.500' North: 195001.3262' East: 1302403.2736' Segment #4 : Line Course: S01° 52' 07.00"W Length: 24.002' North: 194977.3369' East: 1302402.4910' Segment #5 : Line Course: S01° 52' 07.00"W Length: 79.394' North: 194897.9852' East: 1302399.9021' Perimeter: 219.787' Area: 672.05 Sq. Ft. Error Closure: 0.0001 Course: N66° 42' 14.09"W Error North: 0.00003 East: -0.00007 Precision 1: 2197860.000 ************************************************************************ Name: LOT 1 North: 194895.8600' East: 1302499.9191' Segment #1 : Line Course: N88° 46' 58.00"W Length: 100.039' North: 194897.9851' East: 1302399.9027' Segment #2 : Line Course: N01° 52' 07.00"E Length: 79.394' North: 194977.3369' East: 1302402.4916' Segment #3 : Line Course: S88° 50' 09.30"E Length: 100.041' North: 194975.3045' East: 1302502.5119' Segment #4 : Line Course: S01° 52' 07.00"W Length: 79.487' North: 194895.8598' East: 1302499.9200' Perimeter: 358.961' Area: 7946.69 Sq. Ft. Error Closure: 0.0009 Course: S75° 34' 36.30"E Error North: -0.00023 East: 0.00090 Precision 1: 398845.556 ************************************************************************ Name: LOT 2 North: 194893.7720' East: 1302598.1870' Segment #1 : Line Course: N88° 46' 58.00"W Length: 98.290' North: 194895.8600' East: 1302499.9192' Segment #2 : Line Course: N01° 52' 07.00"E Length: 79.487' North: 194975.3047' East: 1302502.5111' Segment #3 : Line Course: N01° 52' 07.00"E Length: 24.002' North: 194999.2940' East: 1302503.2938' Segment #4 : Line Course: S88° 50' 09.30"E Length: 95.332' North: 194997.3572' East: 1302598.6061' Segment #5 : Line Course: S00° 16' 17.00"E Length: 78.042' North: 194919.3161' East: 1302598.9757' Segment #6 : Line Course: S89° 43' 43.00"W Length: 0.880' North: 194919.3119' East: 1302598.0957' Segment #7 : Line Course: S00° 12' 18.00"E Length: 25.540' North: 194893.7721' East: 1302598.1871' Perimeter: 401.573' Area: 10046.76 Sq. Ft. Error Closure: 0.0001 Course: N48° 32' 47.19"E Error North: 0.00007 East: 0.00008 Precision 1: 4015730.000 ************************************************************************ Name: TRACT A North: 195001.3262' East: 1302403.2737' Segment #1 : Line Course: S88° 50' 09.30"E Length: 100.041' North: 194999.2938' East: 1302503.2941' Segment #2 : Line Course: S01° 52' 07.00"W Length: 24.002' North: 194975.3045' East: 1302502.5114' Segment #3 : Line Course: N88° 50' 09.30"W Length: 100.041' North: 194977.3369' East: 1302402.4911' Segment #4 : Line Course: N01° 52' 07.00"E Length: 24.002' North: 195001.3262' East: 1302403.2737' Perimeter: 248.085' Area: 2400.97 Sq. Ft. Error Closure: 0.0000 Course: N00° 00' 00.00"E Error North: 0.00000 East: 0.00000 Precision 1: 248086000.000 /DEEDofDEDICATION.doc\ SMT Page 1 of 4 FORM 04 0001/bh Return Address: City Clerk’s Office City of Renton 1055 South Grady Way Renton, WA 98057 DEED OF DEDICATION Property Tax Parcel Number: Project File #: Street Intersection: Reference Number(s) of Documents assigned or released: Additional reference numbers are on page _____. Grantor(s): Grantee: 1. 2. City of Renton, a Washington Municipal Corporation LEGAL DESCRIPTION: (Abbreviated or full legal must go here. Additional legal on page_______) The Grantor, _________________________, for and in consideration of mutual benefits conveys, quit claims, and dedicates to the Grantee, the City of Renton, the above described real estate situated in the County of King, State of Washington. IN WITNESS WHEREOF, I have hereunto set my hand and seal the day and year as written below. Grantor(s): Dated: INDIVIDUAL FORM OF ACKNOWLEDGMENT STATE OF WASHINGTON ) SS COUNTY OF KING ) I certify that I know or have satisfactory evidence that ______________________ Notary Seal must be within box ________________________________________ signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. Notary Public in and for the State of Washington Notary (Print)_____________________________________ My appointment expires:____________________________ Dated: /DEEDofDEDICATION.doc\ SMT Page 2 of 4 FORM 04 0001/bh REPRESENTATIVE FORM OF ACKNOWLEDGMENT STATE OF WASHINGTON ) SS COUNTY OF KING ) I certify that I know or have satisfactory evidence that ______________________ Notary Seal must be within box ________________________________________ signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. Notary Public in and for the State of Washington Notary (Print)_____________________________________ My appointment expires:____________________________ Dated: CORPORTATE FORM OF ACKNOWLEDGMENT STATE OF WASHINGTON ) SS COUNTY OF KING ) I certify that I know or have satisfactory evidence that ______________________ Notary Seal must be within box ________________________________________ signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. Notary Public in and for the State of Washington Notary (Print)_____________________________________ My appointment expires:____________________________ Dated: Accepted by the City of Renton: By: ________________________________ Mayor Attest: By: ______________________________ City Clerk /DEEDofDEDICATION.doc\ SMT Page 3 of 4 FORM 04 0001/bh Exhibit A Legal Description Project: WO# PID GRANTOR: Street: REAL ESTATE EXCISE TAX AFFIDAVIT CHAPTER 82.45 RCW - CHAPTER 458-61A WAC THIS AFFIDAVIT WILL NOT BE ACCEPTED UNLESS ALL AREAS ON ALL PAGES ARE FULLY COMPLETED Only for sales in a single location code on or after January 1, 2020. This form is your receipt when stamped by cashier. PLEASE TYPE OR PRINT 1 Name 2 Name SELLER GRANTORBUYER GRANTEEMailing Address Mailing Address City/State/Zip City/State/Zip Phone No. (including area code)Phone No. (including area code) 3 Send all property tax correspondence to: o Same as Buyer/Grantee List all real and personal property tax parcel account numbers - check box if personal property List assessed value(s) Name o Mailing Address o City/State/Zip o Phone No. (including area code)o 4 Street address of property: This property is located in o Check box if any of the listed parcels are being segregated from another parcel, are part of a boundary line adjustment or parcels being merged. Legal description of property (if more space is needed, you may attach a separate sheet to each page of the affidavit) 5 Select Land Use Code(s):7 List all personal property (tangible and intangible) included in selling price. enter any additional codes: (See back of last page for instructions) YES NO Was the seller receiving a property tax exemption or deferral under chapters 84.36, 84.37, or 84.38 RCW (nonprofit organization, senior citizen, or disabled person, homeowner with limited income)? o o o o If claiming an exemption, list WAC number and reason for exemption: WAC No. (Section/Subsection) Reason for exemption Is this property predominantly used for timber (as classified under RCW 84.34 and 84.33) or agriculture (as classified under RCW 84.34.020)? See ETA 3215 6 YES NO Is this property designated as forest land per chapter 84.33 RCW? o o Type of Document Is this property classified as current use (open space, farm and agricultural, or timber) land per chapter 84.34 RCW? o o o o Date of Document Gross Selling Price $ Is this property receiving special valuation as historical property per chapter 84.26 RCW? If any answers are yes, complete as instructed below. (1) NOTICE OF CONTINUANCE (FOREST LAND OR CURRENT USE) NEW OWNER(S): To continue the current designation as forest land or classification as current use (open space, farm and agriculture, or timber) land, you must sign on (3) below. The county assessor must then determine if the land transferred continues to qualify and will indicate by signing below. If the land no longer qualifies or you do not wish to continue the designation or classi-fication, it will be removed and the compensating or additional taxes will be due and payable by the seller or transferor at the time of sale. (RCW 84.33.140 or RCW 84.34.108). Prior to signing (3) below, you may contact your local county assessor for more information. Personal Property (deduct) $ Exemption Claimed (deduct) $ Taxable Selling Price $ Excise Tax: State Less than $500,000.01 at 1.1% $ From $500,000.01 to $1,500,000 at 1.28% $ From $1,500,000.01 to $3,000,000 at 2.75% $ This land o does o does not qualify for continuance. Above $3,000,000 at 3.0% $ Agricultural and timberland at 1.28% $ Total Excise Tax: State $ DEPUTY ASSESSOR DATE Local $ (2) NOTICE OF COMPLIANCE (HISTORIC PROPERTY) NEW OWNER(S): To continue special valuation as historic property, sign (3) below. If the new owner(s) does not wish to continue, all additional tax calcu- lated pursuant to chapter 84.26 RCW, shall be due and payable by the seller or transferor at the time of sale. *Delinquent Interest: State $ Local $ *Delinquent Penalty $ Subtotal $ *State Technology Fee $(3) NEW OWNER(S) SIGNATURE *Affidavit Processing Fee $ Total Due $PRINT NAME A MINIMUM OF $10.00 IS DUE IN FEE(S) AND/OR TAX *SEE INSTRUCTIONS 8 I CERTIFY UNDER PENALTY OF PERJURY THAT THE FOREGOING IS TRUE AND CORRECT Signature of Grantor or Grantor’s Agent Signature of Grantee or Grantee’s Agent Name (print) Name (print) Date & city of signing Date & city of signing Perjury: Perjury is a class C felony which is punishable by imprisonment in the state correctional institution for a maximum term of not more than five years, or by a fine in an amount fixed by the court of not more than five thousand dollars ($5,000.00), or by both imprisonment and fine (RCW 9A.20.020(1C)). REV 84 0001a (12/6/19)THIS SPACE - TREASURER’S USE ONLY COUNTY TREASURER List percentage of ownership acquired next to each name. o Check box if partial sale, indicate % ________ sold. o Check box if the sale occurred in more than one location code. INSTRUCTIONS Note: To report a transfer of a controlling interest in real property, please use the Real Estate Excise Tax Affidavit Controlling Interest Transfer Return, Revenue Form No. 84-0001B. This form is available online at http://dor.wa.gov. Section 1: If the sale involves property in more than one location code, use the Multiple Location Real Estate Excise Tax Affidavit. If sale is less than 100%, check the box “Check if partial sale” and fill in the percentage sold. Enter the name(s) of seller/grantor. This is the person(s) conveying interest in the property. Section 2: Enter the name(s) of buyer/grantee. This is the person(s) receiving interest in the property. List the percentage acquired after each name. Section 3: • Enter the name and address where you would like all future property tax information sent. •Enter the tax parcel number and current assessed value for real and personal property being conveyed. Check the box to indicatepersonal property. Section 4: • Enter the street address of the property. • Enter the county if in unincorporated area. Enter city name if located within a municipality. • Enter the legal description of the property. Section 5: Enter the appropriate land use code for the property. Please list all codes that apply on the lines provided in section 5. See WAC 458-53-030(5) for a complete list. 9 - Land with mobile home 10 - Land with new building 11 - Household, single family units 12 - Multiple family residence (2-4 Units)13 - Multiple family residence (5 + Units) 14 - Residential condominiums 15 - Mobile home parks or courts 16 - Hotels/motels 17 - Institutional Lodging (convalescent homes, nursing homes, etc.) 18 - All other residential not coded 19 - Vacation and cabin 21 - Food and kindred products 22 - Textile mill products 23 - Apparel and other finished products made from fabrics, leather, and similar materials 24 - Lumber and wood products (except furniture) 25 - Furniture and fixtures 26 - Paper and allied products 27 - Printing and publishing 28 - Chemicals 29 - Petroleum refining and related industries 30 - Rubber and miscellaneous plastic products 31 - Leather and leather products 32 - Stone, clay and glass products 33 - Primary metal industries 34 - Fabricated metal products 35 - Professional scientific and controlling instruments; photographic and optical goods; watches/clocks manufacturing 39 - Miscellaneous manufacturing 50 - Condominiums-other than resi-dential 53 - Retail Trade - general merchandise 54 - Retail Trade - food 58 - Retail trade - eating & drinking (restaurants, bars)59 - Tenant occupied, commercial properties 64 - Repair services 65 - Professional services (medical, dental, etc.)71 - Cultural activities/nature exhibitions 74 - Recreational activities (golf courses, etc.) 75 - Resorts and group camps 80 - Water or mineral right 81 - Agriculture (not in current use) 83 - Agriculture current use RCW 84.34 86 - Marijuana grow operations 87 - Sale of Standing Timber 88 - Forest land designated RCW 84.33 91 - Undeveloped Land (land only)94 - Open space land RCW 84.34 95 - Timberland classified RCW 84.34 96 - Improvements on leased land •Check yes if the seller was receiving a property tax exemption or deferral under RCW 84.36, 84.37, or 84.38 (nonprofit organization, senior citizen, or disabled person, homeowner with limited income). •Check yes if the land is primarily used for timber as defined by RCW 84.34 and 84.33 or agriculture as defined by RCW 84.34.020. See ETA 3215 for additional information. If the sale involves multiple parcels with different land use codes, complete the predominate use worksheet. Section 6: Indicate whether the property is designated as forest land per chapter 84.33 RCW, classified as current use (open space, farm, agricultural, or timber) per chapter 84.34 RCW, or receiving special valuation as historic property per chapter 84.26 RCW. Section 7: •List personal property included in the selling price of the real property. For example, include tangible (furniture, equipment, etc.) and intangible (goodwill, agreement not to compete, etc.). •Use Tax is due on personal property purchased without payment of the sales tax. Report use tax on your Combined Excise Tax Return or a Consumer Use Tax Return, both available at dor.wa.gov. •If you are claiming a tax exemption, cite the specific Washington Administrative Code (WAC) number, section and subsection and provide a brief explanation. Most tax exemptions require specific documentation. Refer to the appropriate WAC to determine documentation requirements. Chapter 458-61A WAC is available online at dor.wa.gov. •Enter the type of document (quit claim deed, statutory warranty deed, etc.), and date of document (MM/DD/YYYY). •Enter the selling price of the property. •Selling price: For tax purposes, the selling price is the true and fair value of the property conveyed. When property is conveyedin an arm’s length transaction between unrelated persons for valuable consideration, there is a presumption that the selling priceis equal to the total consideration paid or contracted to be paid, including any indebtedness. Refer to RCW 82.45.030 for moreinformation about selling price. •Deduct the amount of personal property included in the selling price. •Deduct the amount of tax exemption claimed per chapter 458-61A WAC. INSTRUCTIONS CONTINUED •Calculate the state excise tax: The state portion of excise tax is calculated using a graduated tax rate structure. The amount of tax increases as the amount of the transaction increases. Each portion of the sales amount is taxed at a different rate. Exception: Property designated as farm and agriculture or timberland is taxed at 1.28% per 83.34 RCW. Instructions1. Enter the sale amount that falls within the specific threshold in column A2. Multiply the amount in column A by the state rate in column B, enter the results in column C3. Enter the amount in column C on the appropriate threshold line on page 1 of the affidavit Example: This is how the state REET tax would be calculated on a sale totaling $1,600,000: Column A Column B Column C Threshold Amount within threshold amount State rate Tax 0 to $500,000 500,000 1.1%5,500 500,000.01 – 1,500,000 1,000,000 1.28%12,800 1,500,000.01 to 3,000,000 100,000 2.75%2,750 3,000,000.01 and above 0 3.0%0 Totals $1,600,000 $21,050 Calculate the state excise tax due using this chart: Column A Column B Column C Threshold Amount within threshold amount State rate Tax 0 to $500,000 1.1% 500,000.01 – 1,500,000 1.28% 1,500,000.01 to 3,000,000 2.75% 3,000,000.01 and above 3.0% Totals Enter the total tax due amount on the Excise Tax: State line on the first page of the affidavit. •Due date, interest and penalties: Tax is due at the time of sale/transfer. If tax is not paid within one month of the date ofsale/transfer, interest and penalties will apply. The interest rate is variable and determined per RCW 82.32.050. Delinquentpenalties are 5% one month after the due date; 10% two months after the due date; and 20% three months after the duedate. (RCW 82.45.100) •State technology fee: A $5.00 electronic technology fee that is due on all transactions. (82.45.180) • Affidavit processing fee: A minimum of $5.00 shall be collected in the form of tax and processing fee. A processing fee isdue on all transactions where no tax is due and on all taxable transactions where the tax due is less than $5.00(RCW 82.45.180) Section 8: Both grantor (seller) and grantee (buyer), or the agent of each, must sign this form, certifying that all the information provided is correct. Note: Original signatures required on the “County Treasurer” copy. Signatures may be required on the “Assessors” copy. Check with your county. Audit: Information you provide on this form is subject to audit by the Department of Revenue. Underpayments of tax will result in the issuance of a tax assessment with interest and penalties. Note: in the event of an audit, it is the taxpayer’s responsibility to provide documentation to support the selling price or any exemption claimed. This documentation must be maintained for a minimum of four years from date of sale. (RCW 82.45.100) Ruling requests: You may request a ruling on the taxability of the property transfer. Go to our website at dor.wa.gov/rulings or fax your request to 360-705-6655. Where to send completed forms: Completed forms must be submitted to the County Treasurer’s or Recorder’s Office where the property is located. For tax assistance, contact your local County Treasurer/Recorder or visit http://dor.wa.gov/REET. To request this document in an alternate format, please call 360-705-6705. Teletype (TTY) users may use the Washington Relay Service by calling 711. REV 84 0001a inst. (11/18/19) SUBDIVISION Guarantee/Certificate Number: Issued By: COMMONWEALTH LAND TITLE INSURANCE COMPANY by its agent: 70149628 Subdivision Guarantee/Certificate Printed: 08.31.20 @ 11:47 AM Page 1 WA-TT-FNWT-02840.660004-SPS-1-20-70149628 COMMONWEALTH LAND TITLE INSURANCE COMPANY, a corporation, herein called the Company, GUARANTEES Encompass Engineering & Surveying, their successors and/or assigns herein called the Assured, against actual loss not exceeding the liability amount stated in Schedule A which the Assured shall sustain by reason of any incorrectness in the assurances set forth in Schedule A. LIABILITY EXCLUSIONS AND LIMITATIONS 1. No guarantee is given nor liability assumed with respect to the identity of any party named or referred to in Schedule A or with respect to the validity, legal effect or priority of any matter shown therein. 2. The Company’s liability hereunder shall be limited to the amount of actual loss sustained by the Assured because of reliance upon the assurance herein set forth, but in no event shall the Company’s liability exceed the liability amount set forth in Schedule A. Please note carefully the liability exclusions and limitations and the specific assurances afforded by this guarantee. If you wish additional liability, or assurances other than as contained herein, please contact the Company for further information as to the availability and cost. Ticor Title Company 437 - 29th St NE, Ste. B Puyallup, WA 98372 Commonwealth Land Title Insurance Company By: Countersigned By: Authorized Officer or Agent President Attest: Secretary Subdivision Guarantee/Certificate Printed: 08.31.20 @ 11:47 AM Page 2 WA-TT-FNWT-02840.660004-SPS-1-20-70149628 COMMONWEALTH LAND TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO.70149628 ISSUING OFFICE: Title Officer: Danny L. Osborn Ticor Title Company 437 - 29th St NE, Ste. B Puyallup, WA 98372 Phone: 253-904-1144 Fax: 877-521-9938 Main Phone: (425)255-7472 Email: Danny.Osborn@ticortitle.com SCHEDULE A Liability Premium Tax $50,000.00 $350.00 $35.00 Effective Date: August 26, 2020 at 08:00 AM The assurances referred to on the face page are: That, according to those public records which, under the recording laws, impart constructive notice of matter relative to the following described property: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF Title to said real property is vested in: Emil Matveyev, as his separate estate subject to the matters shown below under Exceptions, which Exceptions are not necessarily shown in the order of their priority. END OF SCHEDULE A EXHIBIT "A" Legal Description Subdivision Guarantee/Certificate Printed: 08.31.20 @ 11:47 AM Page 3 WA-TT-FNWT-02840.660004-SPS-1-20-70149628 For APN/Parcel ID(s):334270-0510-09 TRACT 103 OF HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN ADDITION TO SEATTLE NO. 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 11 OF PLATS, PAGE 64, RECORDS OF KING COUNTY, WASHINGTON, EXCEPT THE EAST 400 FEET THEREOF: AND EXCEPT THAT PORTION LYING EASTERLY OF THE FOLLOWING DESCRIBED LINE: COMMENCING AT THE SOUTHWEST CORNER OF SAID TRACT 103; THENCE SOUTH 88°44'38" EAST ALONG THE SOUTH LINE THEREOF 204.83 FEET TO THE TRUE POINT OF BEGINNING; THENCE NORTH 0°09'58' WEST 25.54 FEET; THENCE NORTH 89°46'03" EAST 0.88 FEET; THENCE NORTH 0°13'57" WEST 78.05 FEET TO THE NORTH LINE OF SAID TRACT 103 AND THE END OF DESCRIBED LINE; SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. COMMONWEALTH LAND TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO.70149628 SCHEDULE B Subdivision Guarantee/Certificate Printed: 08.31.20 @ 11:47 AM Page 4 WA-TT-FNWT-02840.660004-SPS-1-20-70149628 GENERAL EXCEPTIONS: H. Reservations and exceptions in United States Patents or in Acts authorizing the issuance thereof. SPECIAL EXCEPTIONS: 1.Covenants, conditions, restrictions, recitals, reservations, easements, easement provisions, dedications, building setback lines, notes, statements, and other matters, if any, but omitting any covenants or restrictions, if any, including but not limited to those based upon race, color, religion, sex, sexual orientation, familial status, marital status, disability, handicap, national origin, ancestry, or source of income, as set forth in applicable state or federal laws, except to the extent that said covenant or restriction is permitted by applicable law, as set forth on the Plat of C.D. Hillman's Lake Washington Garden of Eden Addition to Seattle No. 2: Recording No: 304520 2.Covenants, conditions, restrictions, recitals, reservations, easements, easement provisions, dedications, building setback lines, notes, statements, and other matters, if any, but omitting any covenants or restrictions, if any, including but not limited to those based upon race, color, religion, sex, sexual orientation, familial status, marital status, disability, handicap, national origin, ancestry, or source of income, as set forth in applicable state or federal laws, except to the extent that said covenant or restriction is permitted by applicable law, as set forth on Survey: Recording No: 20160825900015 3.General and special taxes and charges, payable February 15, delinquent if first half unpaid on May 1, second half delinquent if unpaid on November 1 of the tax year (amounts do not include interest and penalties): Year: 2020 Tax Account Number: 334270-0510-09 Levy Code: 2100 Assessed Value-Land: $745,000.00 Assessed Value-Improvements: $15,000.00 General and Special Taxes: Billed: $8,764.42 Paid: $4,382.21 Unpaid: $4,382.21 4.The search did not disclose any open mortgages or deeds of trust of record, therefore the Company reserves the right to require further evidence to confirm that the property is unencumbered, and further reserves the right to make additional requirements or add additional items or exceptions upon receipt of the requested evidence. NOTES: Note: FOR INFORMATIONAL PURPOSES ONLY: The following may be used as an abbreviated legal description on the documents to be recorded, per Amended RCW 65.04.045. Said abbreviated legal description is not a substitute for a complete legal description within the body of the document: PTN TRACT 103, HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN ADDN TO SEATTLE NO. 2 Tax Account No.: 334270-0510-09 COMMONWEALTH LAND TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO.70149628 SCHEDULE B (continued) Subdivision Guarantee/Certificate Printed: 08.31.20 @ 11:47 AM Page 5 WA-TT-FNWT-02840.660004-SPS-1-20-70149628 Note: The Public Records indicate that the address of the improvement located on said Land is as follows: 3810 Park Avenue North Renton, WA 98056 END OF SCHEDULE B Order: 70149628 Page 1 of 2 Requested By: ticna1192, Printed: 8/25/2020 10:29 AM Doc: KC:2016 20161221001974 Order: 70149628 Page 2 of 2 Requested By: ticna1192, Printed: 8/25/2020 10:29 AM Doc: KC:2016 20161221001974 Order: 70149628 Page 1 of 2 Requested By: ticna1192, Printed: 8/25/2020 10:29 AM Doc: KC:2016 20161221001975 Order: 70149628 Page 2 of 2 Requested By: ticna1192, Printed: 8/25/2020 10:29 AM Doc: KC:2016 20161221001975 SURFACE WATER UTILITY jfarah 07/10/2019 WASTEWATER UTILITY dchristen 07/15/2019 WATER UTILITY agafour 07/16/2019 DEVELOPMENT ENGINEERING swarlick 07/24/2019 CURRENT PLANNINGAngelea Weihs 07/23/2019 CURRENT PLANNINGAngelea Weihs 07/23/2019 CURRENT PLANNINGAngelea Weihs 07/23/2019 Arborist Report 3810 Park Ave N Renton, WA March 9th, 2017 American Forest Management 3/9/2017 Table of Contents 1. Introduction .............................................................................................................. 1 2. Description ............................................................................................................... 1 3. Methodology ............................................................................................................ 1 4. Observations ........................................................................................................... 2 5. Discussion ............................................................................................................... 3 6. Tree Retention ......................................................................................................... 3 7. Tree Replacement .................................................................................................. .3 8. Tree Protection Measures…………………………………………………………………4 Appendix Site/Tree Photos – pages 5 - 12 Tree Summary Table - attached Tree Plan Map – attached 3810 Park Ave N - Arborist Report Page 1 American Forest Management 3/9/2017 1. Introduction American Forest Management, Inc. was contacted by Emil Matveyev, and was asked to compile an ‘Arborist Report’ for one parcel located within the City of Renton. The proposed 2-lot short plat encompasses the property at 3810 Park Ave N. Our assignment is to prepare a written report on present tree conditions, which is to be filed with the preliminary permit application. This report encompasses all of the criteria set forth under City of Renton code section 4-4-130. The tree retention requirement is 30% of significant trees. Date of Field Examination: March 7th, 2017 2. Description 12 significant trees were identified and assessed on the property. These are comprised of a mix of native species, planted ornamental species and fruit trees. According to City of Renton code, a significant tree is a “tree with a caliper of at least six inches (6"), or an alder or cottonwood tree with a caliper of at least eight inches (8"). Trees qualified as dangerous shall not be considered significant. Trees planted within the most recent ten (10) years shall qualify as significant trees, regardless of the actual caliper.” A numbered aluminum tag was placed on the lower trunks of the subject trees. These numbers were used for this assessment. Tree tag numbers correspond with the numbers on the Tree Summary Tables and copy of the attached site survey. There are no neighboring trees whose drip-lines extend over the property line or encroach upon the subject property. 3. Methodology Each tree in this report was visited. Tree diameters were measured by tape. The tree heights were measured using a Spiegel Relaskop. Each tree was visually examined for defects and vigor. The tree assessment procedure involves the examination of many factors:  The crown of the tree is examined for current vigor. This is comprised of inspecting the crown (foliage, buds and branches) for color, density, form, and annual shoot growth, limb dieback and disease. The percentage of live crown is estimated for coniferous species only and scored appropriately.  The bole or main stem of the tree is inspected for decay, which includes cavities, wounds, fruiting bodies of decay (conks or mushrooms), seams, insects, bleeding, callus development, broken or dead tops, structural defects and unnatural leans. Structural defects include crooks, forks with V-shaped crotches, multiple attachments, and excessive sweep.  The root collar and roots are inspected for the presence of decay, insects and/or damage, as well as if they have been injured, undermined or exposed, or original grade has been altered. Based on these factors a determination of condition is made. The four condition categories are described below based on the species traits assessed: Excellent – free of structural defects, no disease or pest problems, no root issues, excellent structure/form with uniform crown or canopy, foliage of normal color and density, above average vigor, it will be wind firm if isolated, suitable for its location Good – free of significant structural defects, no disease concerns, minor pest issues, no significant root issues, good structure/form with uniform crown or canopy, foliage of normal color and density, average or normal vigor, will be wind firm if isolated or left as part of a grouping or grove of trees, suitable for its location 3810 Park Ave N - Arborist Report Page 2 American Forest Management 3/9/2017 Fair – minor structural defects not expected to contribute to a failure in near future, no disease concerns, moderate pest issues, no significant root issues, asymmetric or unbalanced crown or canopy, average or normal vigor, foliage of normal color, moderate foliage density, will be wind firm if left as part of a grouping or grove of trees, cannot be isolated, suitable for its location Poor – major structural defects expected to fail in near future, disease or significant pest concerns, decline due to old age, significant root issues, asymmetric or unbalanced crown or canopy, sparse or abnormally small foliage, poor vigor, not suitable for its location A ‘viable’ tree is “A significant tree that a qualified professional has determined to be in good health, with a low risk of failure due to structural defects, is wind firm if isolated or remains as part of a grove, and is a species that is suitable for its location.” Trees considered ‘non-viable’ are trees that are in poor condition due to disease, age related decline, have significant decay issues and/or cumulative structural defects, which exacerbate failure potential. The attached tree map indicates the ‘condition’ of the subject trees found at the site. 4. Observations Tree #101 is a black walnut tree north of the current driveway. This tree has good form and a full crown. The subject tree forks into two trunks around 25’ from the ground. The only notable defect is one of the tops that broke off in the past. This tree is in good condition and is viable. Tree #102 is a flowering cherry tree north of the current driveway. The trunk of the subject tree forks 2’ from the ground. The crown is low and widespread. This tree is in fair condition and is viable. Tree #103 is an apple tree south of the current driveway. The subject tree was topped and has two co-dominant trunks. There is visible decay at the point of branch attachment. This tree is in poor condition and is non-viable. Tree #104 is a pear tree south of the current driveway. The subject tree has two co-dominant stems. There was a third co-dominant stem that failed in the past. There is now a large pocket of decay at the point of failure. This tree is in poor condition and is non-viable. Tree #105 is a plum tree. This tree has three co-dominant stems that fork close to the base. The crown is widespread and the tree was topped in the past. This tree is in fair condition and is viable. Tree #106 is an English holly in the southwest corner of the property. The subject tree is in good condition and has no concerning defects. Tree #107 is a common hawthorn south of the home. The trunk of this tree forks around 20’ from the base. The attachment between the two stems is obscured by branches. Some large stems have failed. Overall condition is fair and the tree is viable. Tree #108 is a European white birch on lot 2. There are sapsucker holes throughout the trunk. The crown is full and only one of the tops is dead. The subject tree is in fair condition and is viable. Tree #109 and #110 are western red cedar trees in the northeast corner of the property. There is plywood staked around these trees. Both trees have good trunk taper and healthy foliage. The subject trees are in good condition and are viable. Tree #111 and #112 are apple trees in the southeast corner of the property. Both trees have large cavities of decay and have been topped. Both trees are in poor condition and are non-viable. 3810 Park Ave N - Arborist Report Page 3 American Forest Management 3/9/2017 5. Discussion The extent of drip-lines (farthest reaching branches) for the subject trees can be found on the tree summary tables at the back of this report. These have also been delineated on a copy of the site survey for viable/healthy trees proposed for retention. The information plotted on the attached survey plan may need to be transferred to a final tree retention/protection plan to meet City submittal requirements. The trees that are to be removed shall be shown “X’d” out on the final plan. The Limits of Disturbance (LOD) measurements can also be found on the tree summary table. This is the recommended distance of the closest impact (soil excavation) to the trunk face. These should be referenced when determining tree retention feasibility. The LOD measurements are based on species, age, condition, drip- line, prior improvements, proposed impacts and the anticipated cumulative impacts to the entire root zone. Tree Protection fencing shall be located beyond the drip-line edge of retained trees, and only moved back to the LOD when work is authorized. The house on Lot one will remain, no impacts are anticipated for the trees on this lot, #103 - #107. If construction work will occur on this lot, place tree protection fencing beyond the drip-line edge of the trees. Tree #109 and #110 are western red cedar trees in the northeast corner of the property. These are the only native trees on the property. Western red cedar trees are a long lived species and these two trees are the highest value trees on the property. Retention of both trees is recommended. Remove the plywood stacked next to these trees and apply mulch under the drip lines of both trees. 6. Tree Retention A total of 12 significant trees were identified on the subject property. Four of the significant trees are in poor condition. These four non-viable trees were not included in the tree calculation. A landmark tree is any tree greater than 30” in diameter or greater. There are no landmark trees or tree groves on the subject property. Tree Calculation based on 8, healthy, viable, significant trees Viable Trees proposed for retention – 5 (62.5%) Viable Trees proposed for removal – 3 (37.5%) 7. Tree Replacement Replacements trees may be required. Consult your city planner for tree replacement requirements. All replacement trees are to be planted on site. For planting and maintenance specifications, refer to Section 4-4- 130 of the Renton Tree Ordinances. 3810 Park Ave N - Arborist Report Page 4 American Forest Management 3/9/2017 8. Tree Protection Measures The following guidelines are recommended to ensure that the designated space set aside for the preserved trees are protected and construction impacts are kept to a minimum.  Tree protection barriers shall be initially erected at 5’ outside of the drip-line prior to moving any heavy equipment on site.  Tree protection fencing shall only be moved where necessary to install improvements, but only as close as the Limits of Disturbance, as indicated on the attached plan.  Excavation limits should be laid out in paint on the ground to avoid over excavating.  Excavations within the drip-lines shall be monitored by a qualified tree professional so necessary precautions can be taken to decrease impacts to tree parts. A qualified tree professional shall monitor excavations when work is required and allowed up to the “Limits of Disturbance”.  To establish sub grade for foundations, curbs and pavement sections near the trees, soil should be removed parallel to the roots and not at 90 degree angles to avoid breaking and tearing roots that lead back to the trunk within the drip-line. Any roots damaged during these excavations should be exposed to sound tissue and cut cleanly with a saw. Cutting tools should be sterilized with alcohol.  Areas excavated within the drip-line of retained trees should be thoroughly irrigated weekly during dry periods.  Preparations for final landscaping shall be accomplished by hand within the drip-lines of retained trees. Plantings within the drip lines shall be limited. Large equipment shall be kept outside of the tree protection zones. There is no warranty suggested for any of the trees subject to this report. Weather, latent tree conditions, and future man-caused activities could cause physiologic changes and deteriorating tree condition. Over time, deteriorating tree conditions may appear and there may be conditions, which are not now visible which, could cause tree failure. This report or the verbal comments made at the site in no way warrant the structural stability or long term condition of any tree, but represent my opinion based on the observations made. Nearly all trees in any condition standing within reach of improvements or human use areas represent hazards that could lead to damage or injury. Please call if you have any questions or I can be of further assistance. Sincerely, Kelly Wilkinson kelly.wilkinson@afmforest.com ISA Certified Arborist #PN-7673A ISA Tree Risk Assessment Qualified 3810 Park Ave N - Arborist Report Page 5 American Forest Management 3/9/2017 Photos Tree #101 – black walnut 3810 Park Ave N - Arborist Report Page 6 American Forest Management 3/9/2017 Tree #102 – flowering cherry tree Tree #104 and #103 – pear and apple trees 3810 Park Ave N - Arborist Report Page 7 American Forest Management 3/9/2017 Tree #104 – pear tree with significant decay at the point of co-dominant stem attachment Tree #105 – plum tree 3810 Park Ave N - Arborist Report Page 8 American Forest Management 3/9/2017 Tree #107 – common hawthorn 3810 Park Ave N - Arborist Report Page 9 American Forest Management 3/9/2017 Tree #108 – white birch 3810 Park Ave N - Arborist Report Page 10 American Forest Management 3/9/2017 Tree #109 and #110 – western red cedar trees 3810 Park Ave N - Arborist Report Page 11 American Forest Management 3/9/2017 Tree #111 – apple tree 3810 Park Ave N - Arborist Report Page 12 American Forest Management 3/9/2017 Tree #112 – apple tree Tree Summary Table American Forest Management, Inc. For:3810 Park Ave N Date:3/7/2017 City of Renton Inspector:Wilkinson Tree/DBH Height Tag #Species (inches)(feet)Condition Viability Comments Proposal N S E W 101 black walnut 26 64 16 / 13 15 / 13 17 / 13 24 / 13 good viable Crook in trunk, forks at 25', one top broke off remove 102 flowering cherry 8, 8 13 4 / 6 8 / 6 9 / 6 10 / 6 fair viable trunk forks at 2', ok attachment remove 103 apple 8, 6 13 7 9 5 6 poor non-viable topped, co-dominant trunks, decay at branch attachment, low risk retain 104 pear 7, 6 17 5 7 5 3 poor non-viable Forks at 2', included bark at branch attachment, topped, low risk retain 105 plum 5, 5, 4 14 7 / 6 8 / 6 6 / 6 6 / 6 fair viable trunk forks at base, widespread crown, topped retain 106 English holly 9 27 7 / 6 6 / 6 5 / 6 6 / 6 good viable no concerning defects retain 107 common hawthorn 15 42 13 / 8 8 / 8 4 / 8 11 / 8 fair viable forked trunk at 20'retain 108 European white birch 14 53 15 12 10 14 fair viable Sapsucker holes remove 109 western red cedar 10 31 9 / 8 8 / 8 6 / 8 10 / 8 good viable plywood stacked next to trunk retain 110 western red cedar 10 31 8 / 8 7 / 8 4 / 8 9 / 8 good viable plywood stacked next to trunk retain 111 apple 18 19 5 7 8 9 poor non-viable topped, severe decay remove 112 apple 14 18 5 2 4 5 poor non-viable topped, severe decay remove Drip-Line and Limits of Disturbance measurements from face of trunk Drip-Line/Limits of Disturbance (feet) Trees on neighboring properties - Drip-line and Limits of Disturbance measurements from property lines Tree Map EarthSolutionsNWLLC EarthSolutionsNWLLC Geotechnical Engineering Geology Environmental Scientists Construction Monitoring 1805 -136th Place N.E.,Suite 201 Bellevue,WA 98005 (425)449-4704 Fax (425)449-4711 www.earthsolutionsnw.com GEOTECHNICAL ENGINEERING STUDY PROPOSED SHORT PLAT 3810 PARK AVENUE NORTH RENTON,WASHINGTON ES-5134 Drwn. Checked Date Date Proj.No. Plate Earth Solutions NWLLC Geotechnical Engineering,Construction Monitoring EarthSolutionsNWLLC EarthSolutionsNWLLC and Environmental Sciences Vicinity Map Matveyev Short Plat Renton,Washington MRS CGH 04/28/2017 April 2017 5134 1 NORTH NOTE:This plate may contain areas of color.ESNW cannot be responsible for any subsequent misinterpretation of the information resulting from black &white reproductions of this plate. Reference: King County,Washington Map 626 By The Thomas Guide Rand McNally 32nd Edition SITE Drwn. Checked Date Date Proj.No. Plate Earth Solutions NWLLC Geotechnical Engineering,Construction Monitoring EarthSolutionsNWLLC EarthSolutionsNWLLC and Environmental Sciences NORTH 0 20 40 80 Scale in Feet1"=40' NOTE:This plate may contain areas of color.ESNW cannot be responsible for any subsequent misinterpretation of the information resulting from black &white reproductions of this plate. NOTE:The graphics shown on this plate are not intended for design purposes or precise scale measurements,but only to illustrate the approximate test locations relative to the approximate locations of existing and /or proposed site features.The information illustrated is largely based on data provided by the client at the time of our study.ESNW cannot be responsible for subsequent design changes or interpretation of the data by others. LEGEND Approximate Location of ESNW Test Pit,Proj.No. ES-5134,Mar.2017 Subject Site Existing Building Test Pit Location Plan Matveyev Short Plat Renton,Washington MRS CGH 05/01/2017 May 2017 5134 2 TP-1 TP-2 TP-4 TP-3 House Garage Shed Landscaping Pond TP-1 Asphalt Driveway PARK AVENUE N.130 140 130 140 Drwn. Checked Date Date Proj.No. Plate Earth Solutions NWLLC Geotechnical Engineering,Construction MonitoringandEnvironmentalSciences EarthSolutionsNWLLC EarthSolutionsNWLLC RETAINING WALL DRAINAGE DETAIL Matveyev Short Plat Renton,Washington MRS CGH 05/01/2017 May 2017 5134 3 NOTES: Free Draining Backfill should consist of soil having less than 5 percent fines. Percent passing #4 should be 25 to 75 percent. Sheet Drain may be feasible in lieu of Free Draining Backfill,per ESNW recommendations. Drain Pipe should consist of perforated, rigid PVC Pipe surrounded with 1" Drain Rock. LEGEND: Free Draining Structural Backfill 1 inch Drain Rock 18"Min. Structural Fill Perforated Drain Pipe (Surround In Drain Rock) SCHEMATIC ONLY -NOT TO SCALE NOT A CONSTRUCTION DRAWING Drwn. Checked Date Date Proj.No. Plate Earth Solutions NWLLC Geotechnical Engineering,Construction Monitoring and Environmental Sciences EarthSolutionsNWLLC EarthSolutionsNWLLC FOOTING DRAIN DETAIL Slope Perforated Rigid Drain Pipe (Surround with 1"Rock) 18"(Min.) NOTES: Do NOT tie roof downspouts to Footing Drain. Surface Seal to consist of 12"of less permeable,suitable soil.Slope away from building. LEGEND: Surface Seal;native soil or other low permeability material. 1"Drain Rock SCHEMATIC ONLY -NOT TO SCALE NOT A CONSTRUCTION DRAWING Matveyev Short Plat Renton,Washington MRS CGH 05/01/2017 May 2017 5134 4 DEPARTMENTOFCOMMUNITYANDECONOMICDEVELOPMENTC—“Renton0A.ADMINISTRATIVEREPORT&DECISIONDECISION:EAPPROVEDAPPROVEDSUBJECTTOCONDITIONSDENIEDREPORTDATE:October10,2017ProjectName:MatveyevShortPlatOwner:EmilMatveyev;807KirklandWay,Kirkland,WA98033Applicant/Contact:NicoleMecum;165NEJuniperSt.Suite201,Issaquah,WA98027ProjectFileNumber:PR17-000389LandUseFileLUA17-000503Number:ProjectManager:AngeleaWeihs,AssociatePlannerProjectSummary:TheapplicantisrequestingPreliminaryShortPlatandaStreetModificationfortheproposedsubdivisionofanexisting21,067squarefoot(0.47acre)lot,zonedResidential-6(R-6),intotwolots.Theproposedresidentialdensityis4.84dwellingunitspernetacre.Onesinglefamilyresidenceispresentlyonthepropertyandisproposedforremoval.Theproposedresidentiallotsizesare7,947SFforLot1,and10,047SFforLot2.Accesstothenewlotsisproposedviaa2,401SFshareddriveway/tractoffofParkAveN.Theapplicantproposestoretain2significanttreeson-siteandremove10significanttrees.Moderatelandslidehazardsandsensitiveslopesaremappedwithin50feetoftheprojectsite.TheapplicantsubmittedanArboristReportandGeotechnicalEngineeringStudywiththeapplication.ProjectLocation:3810ParkAveNSiteArea:0.48acresProjectLocationMapSTAFFREPORTMAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAP/EYEVSHORTPMTLUA17-000SOI,SHPL-AOctober10,2017Page2of17EXHIBITS:Exhibit1:StaffReportExhibit2:ShortPlatPlanExhibit3:LandscapePlanExhibit4:ArboristReportExhibit5:TreeRemovaiPlanExhibit6:DrainageReport(datedJune28,2017)Exhibit7:ConceptualDrainage/UtilitiesPlanExhibit8:GeotechnicalReport(May18th,2017)Exhibit9:DensityWorksheetExhibit10:PublicCommentletterts)Exhibit11:StaffResponsetoPublicCommentsExhibit12:AdvisoryNotesrcGENERALINFORMATION:EmilMatveyev1.Owner(s)ofRecord:807KirklandWayKirkland,WA980332.ZoningClassification:R-63.ComprehensivePlanLandUseDesignation:ResidentialMediumDensity4.ExistingSiteUse:Existingsinglefamilyresidenceproposedforremoval.5.CriticalAreas:ModerateLandslideHazardsandSensitiveSlopes6.NeighborhoodCharacteristics:a.North:Singlefamilyresidential(8-6)b.East:Singlefamilyresidential(8-6)c.South:Singlefamilyresidential(8-6)d.West:Singlefamilyresidential(8-6)6.SiteArea:0.48acresD.HISTORICAL/BACKGROUND:ActionLandUseFileNo.OrdinanceNo.DateComprehensivePlanN/A575806/22/2015ZoningN/A575806/22/2015AnnexationN/A253112/31/1969STAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEYEVSHORTPMTOctober10,2017SHPL-APage3of17EPUBLICSERVICES:1.ExistingUtilitiesa.Water:WaterservicewillbeprovidedbytheCityofRenton.Thereisanexisting12-inchwatermaininParkAveN.b.Sewer:SewerserviceisprovidedbytheCityofRenton.ThereisanexistingS-inchsewermainlocatedonthewestsideoftheproperty(RecordDrawing:5-014207).c.Surface/StormWater:Thereisanexisting12-inchstormwatermainlocatedonthewestsideoftheproperty.2.Streets:ThesubjectpropertyfrontsParkAveNalongthewestpropertyline.ParkAveNisclassifiedasaCollectorArterialRoad.3.FireProtection:CityofRentonFireDepartmentrF.APPLICABLESECTIONSOFTHERENTONMUNICIPALCODE:11.Chapter2LandUseDistrictsa.Section4-2-020:PurposeandIntentofZoningDistrictsb.Section4-2-070:ZoningUseTablec.Section4-2-110:ResidentialDevelopmentStandardsd.Section4-2-115:ResidentialDesignandOpenSpaceStandards2.Chapter3EnvironmentalRegulationsa.Section4-3-050:CriticalAreaRegulations3.Chapter4PropertyDevelopmentStandards4.Chapter6StreetsandUtilityStandardsa.Section4-6-060:StreetStandards5.Chapter7SubdivisionRegulationsa.Section4-7-070:DetailedProceduresforShortSubdivision6.Chapter11DefinitionsG.APPLICABLESECTIONSOFTHECOMPREHENSIVEPLAN:1.LandUseElementrH.FINDINGSOFFACT(FOF)1.ThePlanningDivisionoftheCityofRentonacceptedtheabovemasterapplicationforreviewonJuly26,2017,anddeterminedtheapplicationcompleteonAugust3,2017.Theprojectcomplieswiththe120-dayreviewperiod.2.Theprojectsiteislocated3810ParkAveN.3.Theprojectsiteiscurrentlydevelopedwithanexisting2,050SFsinglefamilyresidenceandaccessorystructure(approx.100SFshed).Theexistingsinglefamilyhomeandaccessorystructureareproposedtoberemoved.4.AccesstothesitewouldbeprovidedviaashareddrivewayextendingfromParkAveN.5.ThepropertyislocatedwithintheResidentialMediumDensityComprehensivePlanlandusedesignation.STAFFREPORT_MATh/EYEVSP(2) CityofRentonDeportmentofCommunity&EconomicDevelopmentAdministrotiveReport&DecisionMAWEVEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page4of176.ThesiteislocatedwithintheR-6zoningclassification.7.Thereareapproximately12significanttreeslocatedonsiteofwhichtheapplicantisproposingtoretainatotalof3trees.8.ThesiteismappedwithModerateLandslideHazardsandSensitiveSlopes.9.Gradingisproposedforfrontageimprovements.Approximatley100cubicyardsofexcavation/fillisproposedforthefrontageimprovements.10.TheapplicantisproposingtobeginconstructionintheFallof2017andcompleteconstructioninapproximatleytwomonths.11.Staffreceivedonepubliccommentletter(Exhibit10).Toaddresspubliccomments,thefollowingreportcontainsanalysisrelatedtotreeprotectionandthegeotechnicalreport.12.Representativesfromvariouscitydepartmentshavereviewedtheapplicationmaterialstoidentifyandaddressissuesraisedbytheproposeddevelopment.Thesecommentsarecontainedintheofficialfile,andtheessenceofthecommentshasbeenincorporatedintotheappropriatesectionsofthisreportandtheDepartmentalRecommendationattheendofthisreport.13.ComprehensivePlanCompliance:ThesiteisdesignatedResidentialMediumDensity(MD)ontheCity’sComprehensivePlanMap.ThepurposeoftheMDdesignationistoallowavarietyof5ingle-familyandmulti-familydevelopmenttypes,withcontinuitycreatedthroughtheapplicationofdesignguidelines,theorganizationofroadways,sidewalks,publicspaces,andtheplacementofcommunitygatheringplacesandcivicamenities.TheproposaliscompliantwiththefollowingComprehensivePlanGoalsandPoliciesifjjconditionsofapprovalaremet:ComplianceComprehensivePlanAnalysis,.Policy1-3:Encourageinfilldevelopmentofsingle-familyunitsasameanstomeetgrowthtargetsandprovidenewhousing.GoalL-l:Utilizemultiplestrategiestoaccommodateresidentialgrowth,including:.Developmentofnewsingle-familyneighborhoodsonlargetractsoflandoutsidetheCityCenter,,t•Developmentofnewmulti-familyandmixed-useintheCityCenterandintheResidentialHighDensityandCommercialMixedUsedesignations,and•Infilldevelopmentonvacantandunderutilizedlandinestablishedneighborhoods•andmulti-familyareas.“Policy1-37:Landusesinareassubjecttoflooding,seismic,geologic,andcoalminehazardsshouldbedesignedtopreventpropertydamageandenvironmentaldegradationbefore,during,andafterconstruction.“GoalL-BB:MaintainahighqualityoflifeasRentongrowsbyensuringthatnewdevelopmentisdesignedtobefunctionalandattractive.‘GoalL-FF:StrengthenthevisualidentityofRentonanditsCommunityPlanningAreasandneighborhoodsthroughqualitydesignanddevelopment.“Policy1-49:Addressprivacyandqualityoflifeforexistingresidentsbyconsideringscaleandcontextininfillprojectdesign.STAFFREPORTMAWEYEVSP(2) CityofRentonDeportmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEYEWSHORTPMTLUAI7-000503,SHPL-AOctober10,2017Page5of1714.ZoningDevelopmentStandardCompliance:ThesiteisclassifiedResidential-6(R-6)ontheCity’sZoningMap.DevelopmentintheR-6zoneisintendedtobesinglefamilyresidentialatmoderatedensity.Theproposaliscompliantwiththefollowingdevelopmentstandards,asoutlinedinRMC4-2-11OA,ifallconditionsofapprovalaremet:ComplianceR-6ZoneDevelopStandardsandAnalysisDensity:ThedensityrangepermittedintheR-6zoneisaminimum3.0uptoamaximumof6.0dwellingunitspernetacre.Netdensityiscalculatedafterthedeductionofsensitiveareas,areasintendedforpublicright-of-way,andprivateaccesseasements.vStaffComment:Theprojectsitehasanetsiteareaof17,994squarefeet(0.41acres)afterthedeductionof672squarefeetofright-of-waydedicationand2,401squarefeetofshareddrivewayfromthe21,067grosssitearea.Theproposalfor2lotsonthe0.48acresiteresultsinanetdensityof4.8dwellingunitpernetacre,whichiswithinthedensityrangepermittedintheR-6zone.LotDimensions:TheminimumlotsizepermittedintheR-6zoneis7,000sq.ft.Aminimumlotwidthof60feetisrequired(70feetforcornerlots)andaminimumlotdepthof90feetisrequired.ThefollowingtableidentifiestheproposedapproximatedimensionsforLots1-2ProposedLotLotSize(sq.ft.)ILotWidth(feet)LotDepth(feet)Lot1(cornerlot)7,94779.44100.04Lot210,047103.5396.81StaffComment:Allproposedlotswouldcomplywiththeminimumlotsize,widthanddepthrequirementsfortheR-6zone.Setbacks:TherequiredsetbacksintheR-6zoneareasfollows:frontyardis25feet,sideyardiscombined15feetwithnotlessthan5feetoneitherside,secondaryfrontyard(appliestocornerlots)is25feet,andtherearyardis25feet.StaffComment:Thelotsasproposedprovideadequateareafortheconstructionofnewhomesincompliancewiththesetbackrequirements.Anexistingsinglefamilyresidenceisproposedforremoval.Staffrecommends,asaconditionofapproval,thatademolitionpermitbeobtainedfortheexistingresidenceandallrequiredinspectionscompletedpriortotheapprovalofthefinalshortplat.BuildingStandards:TheR-6zonehasamaximumbuildingcoverageof40%andamaximumimpervioussurfacecoverageof55%.IntheR-6zone,amaximumbuildingheightof2storieswithawallplateheightof24feetispermitted.Roofswithapitchequaltoorgreaterthan4:12mayprojectanadditionalsix(6)verticalfeetfromthemaximumwallplateheight.Iftheheightofwallplatesonabuildingarelessthanthestatesmaximumtheroofmayprojecthighertoaccountforthedifference,yettheVcombinedheightofbothfeaturesshallnotexceedthecombinedmaximums.Commonrooftopfeatures,suchaschimneys,mayprojectanadditionalfour(4)verticalfeetfromtheroofsurface.Non-exemptverticalprojections(e.g.,roofspitchedlessthan4:12,decks,railings,etc.)mayextenduptosix(6)verticalfeetabovethemaximumwallplateheightiftheprojectionissteppedbackone-and-a-half(1.5)horizontalfeetfromeachminimumbuildingsetbacklineforeachone(1)verticalfootabovethemaximumwallplateheight.STAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAP/EVEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page6of17Wallplatessupportingaprimaryroofsurfacethathasonlyone(1)slopingplane(e.g.,shedroof)mayexceedthestatedmaximumiftheaverageofwallplateheightsisequalorlessthanthemaximumwallplateheightallowed.StaffComment:Buildingheight,buildingcoverage,andimpervioussurfacecoverageforthenewsinglefamilyresidenceswouldbeverifiedatthetimeofbuildingpermitreview.Landscaping:TheCity’slandscaperegulations(RMC4-4-070)requirea10-footlandscapestripalongallpublicStreetfrontages.AdditionalminimumplantingstripwidthsbetweenthecurbandsidewalkareestablishedaccordingtothestreetdevelopmentstandardsofRMC4-6-060.Streettreesand,ataminimum,groundcover,aretobelocatedinthisareawhenpresent.SpacingstandardsshallbeasstipulatedbytheDepartmentofCommunityandEconomicDevelopment,providedthereshallbeaminimumofonestreettreeplantedperaddress.Anyadditionalundevelopedright-of-wayareasshallbelandscapedunlessotherwisedeterminedbytheAdministrator.Wherethereisinsufficientright-of-wayspaceornopublicfrontage,streettreesarerequiredinthefrontyardsubjecttoapprovaloftheAdministrator.AminimumoftwotreesaretobelocatedinthefrontyardpriortofinalinspectionforthenewSingleFamilyResidence.StaffComment:AConceptualLandscapePlan(Exhibit3)wassubmittedwiththepreliminaryshortplatapplicationmaterials.Theconceptuallandscapeplanshowsan8-footlandscapestripbetweenthecurbandsidewalkanda10-footon-sitelandscapeCompliantifstrip.Thelandscapeplandoesnotshowtherequiredlandscapeareawithinthesharedconditionofdrivewaytract.Inaddition,two(2)treesarerequiredtobelocatedinthefrontyardofapprovalisLot2asitdoesnothavepublicstreetfrontage.Therefore,Staffrecommends,asametconditionofapproval,thattheapplicantsubmitafinaldetailedlandscapeplanthatincludesrequiredshareddrivewaytractlandscaping,requiredfrontyardtrees,andcomplieswithRMC4-8-1200.12atthetimeofutilityconstructionpermitapplicationtothecurrentplanningprojectmanagerfarreviewandapprovalpriortoconstructionpermitissuance.TractAwouldcontainan8-footlandscapestripbetweentheedgeafthepavementandthenorthpropertyline.Inorderforthislandscapeareatobemaintainedequallybybothlots,theapplicantwouldberequiredtorecordanoteonthefaceoftheplatthatexecutesasharedmaintenanceagreementforequalownershipandmaintenanceresponsibilitiesforimprovementsinTractA.Adraftversionofasharedmaintenanceagreementshallbesubmittedforreviewandapprovalbythecurrentplanningprojectmanagerpriortoshortplatrecording.IftheapplicantcreatesahomeownersassociationforownershipandmaintenanceresponsibilitiesforimprovementsinTractA,thenHOAdocumentsshallbesubmittedforreviewandapprovalbythecurrentplanningprojectmanagerandtheCityAttorneypriortoshortplatrecording.TreeRetention:TheCity’sadoptedTreeRetentionandLandClearingRegulations(4-4-130)requiretheretentionof30percentoftreesinaresidentialdevelopment.CompliantifSignificanttreesshallberetainedinthefollowingpriorityorder:conditionofapprovalisPriorityOne:Landmarktrees;significanttreesthatformacontinuouscanopy;metsignificanttreesonslopesgreaterthantwentypercent(20%);significanttreesadjacenttocriticalareasandtheirassociatedbuffers;andsignificanttreesoversixtyfeet(60’)inheightorgreaterthaneighteeninches(18”)caliper.STAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEYEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page7of17PriorityTwo:Healthytreegroupingswhoseassociatedundergrowthcanbepreserved;othersignificantnativeevergreenordeciduoustrees;andothersignificantnon-nativetrees.PriorityThree:Aldersandcottonwoodsshallberetainedwhenallothertreeshavebeenevaluatedforretentionandarenotabletoberetained,unlessthealdersand!orcottonwoodsareusedaspartofanapprovedenhancementprojectwithinacriticalareaoritsbuffer.Aminimumtreedensityshallbemaintainedoneachresidentiallyzonedlot.Fordetachedsinglefamilydevelopment,theminimumtreedensityistwo(2)significanttreesforeveryfivethousand(5,000)squarefeet.Thetreedensitymayconsistofexistingtrees,replacementtrees,treesrequiredpursuanttoRMC4-4-070F1,StreetFrontageLandscapingRequired,oracombination.StaffComment:AconceptualTreeRetentionPlan(Exhibits)andArbor/stReport(Exhibit4)weresubmittedwiththeprojectapplicationmaterials.TheTreeRetentionPlanandArbor/stReportidentify12significanttreesonsite.Fourofthetreesoreidentifiedinthearbor/streportas“non-viable”basedonpoorhealth/conditionondarerecommendedforremovaLOnetreeisintheproposedpublicright-of-way/frontageimprovements,andtwotreesarelocatedintheproposedshareddrivewaytract.Atotaloffivetreesremainfollowingthedeductionofnon-viabletreesandtreeslocatedinthepublicright-of-wayandaccesseosement.Threeofthefivetreesareproposedforremovalduetoproximitytoproposednewsinglefamilyresidences.Theapplicantisproposingtoretaintwo(10-caliperincheseach)Cedartrees,whichcomplieswiththeminimumtreeretentionrequirementsoftheR-6zone.Inadditiontocomplyingwiththeminimumtreeretentionrequirements,theapplicantisrequiredtoretainorplanttwo(2)significanttrees,orgrossequivalentcabperinches,per5,000squarefeetoflotarea.Aminimumoffour(4)treesarerequiredonLot2tocomplywithtreedensityrequirements.TheconceptualLandscapePlandemonstratescomplianceforLot2byshowingatotaloffour(4)significanttrees,twocedartreestoberetainedandtwoproposedShorePinetrees.However,theconceptualLandscapePlatdoesnotdemonstratecompliancewithminimumtreedensityrequirementsofthezoneLot1.NotreesareproposedforretentiononLot1,andthelandscapeplanonlyshowsonenewtreeonsite.Treeslocatedinpublicright-of-wayarenotcountedtowardstreeretention.Aminimumofthree(3)treesarerequiredonLotItocomplywithtreedensityrequirements,therefore,staffrecommendsasaconditionofapproval,thattheapplicantsubmitafinaldetailedlandscapeplanshowingtwo(2)additionaltreesonLotIinordertomeettheminimumtreedensityrequirementofthree(3)trees.Onsitelandscapingshallbeinstalledpriortofinaloccupancyfortheindividualhomesandlandscapingwithintheright-of-wayshallbeinstalledpriortoshortplatrecording.Parking:Parkingregulationsrequirethataminimumoftwoparkingspacesbeprovidedforeachdetacheddwelling.Drivewaycutsarerequiredtobeaminimumof5feetfrompropertylinesandnewvdrivewaysmaybeamaximumof16feetinwidthatthepropertyline.Maximumdrivewayslopesshallnotexceedfifteenpercent(15%);provided,thatdrivewaysexceedingeightpercent(8%)shallprovideslotteddrainsatthelowerendwithpositivedrainagedischargetorestrictrunofffromenteringthegarage/residenceorcrossinganypublicsidewalk.5TAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEVEVSHORTPLATLUA17-000503,SHPL-AOctober10,2017Page8of17StaffComment:Compliancewiththeparkinganddrivewayrequirementswouldbeverifiedatthetimeofbuildingpermitreviewfortheindividualresidences.However,thereisadequateareaprovidedon-sitefortheaccommodationoftwoon-siteparkingspaces.15.DesignStandards:ResidentialDesignandOpenSpaceStandards(RMC4-2-115)areapplicableintheR6zone.TheStandardsimplementpoliciesestablishedintheLandUseElementoftheComprehensivePlan.CompliancewithSiteDesignStandardsmustbedemonstratedpriortoapprovalofthesubdivision.CompliancewithResidentialDesignStandardswouldbeverifiedpriortoissuanceofthebuildingpermitforthenewsinglefamilyhomes.Theproposalisconsistentwiththefollowingdesignstandards,unlessnotedotherwise:‘LotConfiguration:Oneofthefollowingisrequiredofpreliminaryplatapplications:1.Lotwidthvariationof10feet(10’)minimumofoneperfour(4)abuttingstreet-frontinglots,orN/A2.Minimumoffour(4)lotsizes(minimumoffourhundred(400)grosssquarefeetsizedifference)forstreet-frontinglots,or3.Afrontyardsetbackvariationofatleastfivefeet(5’)minimumforatleasteveryfour(4)abuttingstreetfrontinglots.StaffComment:Notapplicabletoshortplots.Garages:Ifanattachedgarageiswiderthantwentysixfeet(26’),atleastone(1)garagedoorshallberecessedaminimumoffourfeet(4’)fromtheothergaragedoor.Additionally,oneofthefollowingisrequired:1.Thefrontporchprojectsinfrontofthegarageaminimumoffivefeet(5’),andisaminimumoftwelvefeet(12’)wide,or2.Theroofextendsatleastfivefeet(S)(notincludingeaves)beyondthefrontofthegarageforatleastthewidthofthegarageplustheporch/stooparea,or3.Thegarageisalleyaccessed,orCompliancenotyet4.Thegarageentrydoesnotfaceapublicand/orprivatestreetorandemonstratediaccesseasement,or5.Thegaragewidthrepresentsnogreaterthanfiftypercent(50%)ofthewidthofthefrontfacadeatgroundlevel,or6.Thegarageisdetached,or7.Thegaragedoorscontainaminimumofthirtypercent(30%)glazing,architecturaldetailing(e.g.trimandhardware),andarerecessedfromthefrontfaçadeaminimumoffivefeet(5’),andfromthefrontporchaminimumofsevenfeet(7’).StaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.CompliancePrimaryEntry:Theentryshallincludeaporchorstoopwithaminimumdepthofnotyetfivefeet(5’)andminimumheightoftwelveinches(12”)abovegrade.demonstratedException:incaseswhereaccessibility(ADA)isapriority,anaccessibleroutemaybetakenfromafrontdriveway.STAFFREPORTMAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAP/EYEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page9of17!StaffComment:Compliancefarthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.FaçadeModulation:Oneofthefollowingisrequired:1.Anoffsetofatleastonestorythatisatleasttenfeet(10’)wideandtwoCompliancefeet(2’)indepthonfacadesvisiblefromthestreet,ornotyet2.Atleasttwofeet(2’)offsetofsecondstoryfromfirststoryononestreetdemonstratedfacingfacade.StaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuilding:permitreview.ComplianceWindowsandDoors:Windowsanddoorsshallconstitutetwenty-fivepercent(25%)notyetofallfacadesfacingStreetfrontageorpublicspaces.demonstratedStaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.N/AScale,Bulk,andCharacter:N/AComplianceRoofs:Avarietyofroofformsappropriatetothestyleofthehomeshallbeused.notyetStaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingdemonstratedpermitreview.Eaves:Bothofthefollowingarerequired:1.Eavesprojectingfromtheroofoftheentirebuildingatleastcompliancetwelveinches(12”)withhorizontalfasciaorfasciagutteratleastnotyetfiveinches(5”)deeponthefaceofalleaves,anddemonstrated2.Rakesongableendsmustextendaminimumoftwoinches(2’)fromthesurfaceofexteriorsidingmaterials.StaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.ArchitecturalDetailing:Ifonesidingmaterialisusedonanysideofthedwellingthatistwostoriesorgreaterinheight,ahorizontalbandthatmeasuresatleasteightinches(8”)isrequiredbetweenthefirstandsecondstory.Additionally,oneofthefollowingisrequired:Compliance1.Threeandonehalfinch(31/2”)minimumtrimsurroundsallwindowsnotyetanddetailsaltdoors,ordemonstrated.2.Acombinationofshuttersandthreeandonehalfinches(31/2minimumtrimdetailsallwindows,andthreeandonehalfinches(31/2’)minimumtrimdetailsalldoors.StaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.•MaterialsandColor:Forsubdivisionsandshortplats,abuttinghomesshallbeof.differingcolor.Colorpalettesforallnewdwellings,codedtothehomeelevations,Complianceshallbesubmittedforapproval.notyetdemonstratedAdditionally,oneofthefollowingisrequired:1.Aminimumoftwo(2)colorsisusedonthehome(bodywithdifferentIcolortrimisacceptable),orSTAFFREPORTMAP/EYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEVEVSHORTATLUAI7-000503,SHPL-AOctober10,2017Page10of172.Aminimumoftwo(2)differingsidingmaterials(horizontalsidingandshingles,sidingandmasonryormasonry-likematerial,etc.)isusedonthehome.Onealternativesidingmaterialmustcompriseaminimumofthirtypercent(30%)ofthestreetfacingfacade.Ifmasonrysidingisused,itshallwrapthecornersnolessthantwentyfourinches(24).StaffComment:Complianceforthisstandardwouldbeverifiedatthetimeofbuildingpermitreview.16.CriticalAreas:Amoderatelandslidehazardandsensitiveslopearemappedwithin50feetoftheproperty.Noothercriticalareasareidentifiedonsite.ProjectsiteswhichcontaincriticalareasarerequiredtocomplywiththeCriticalAreasRegulations(RMC4-3-050).TheproposalisconsistentwiththeCriticalAreasRegulations:CompliantifGeologicallyHazardousAreas:Basedupontheresultsofageotechnicalreportand/orconditionofindependentreview,conditionsofapprovalfordevelopmentsmayincludebuffersapprovalisand/orsetbacksfrombuffers.Astandard15-footbuildingsetbackisrequiredforallmetstructuresfromProtectedSlopeareas.ASO-footbufferand15-tootbuildingsetbackarerequiredfromVeryHighLandslideHazardAreas.StaffComment:CityRecordsindicatethatamoderatelandslidehazardandsensitiveslopearemappedwithin50feetoftheproperty.Ageotechnicalengineeringstudy,datedMay18th,2017,completedbyEarthSolutionsNW(ESNW),LLC,wasprovidedwiththeapplication.InMarch2017,anESNWrepresentativesampledfourtestpitsforthepurposesofassessingandclassifyingsubsurfacesoilandgroundwaterconditions.Thenativesoilsencounteredaspartoftheevaluationconsistedprimarilyofsiltysandandsandysilt,inaloosetodenseandmoisttowetcondition.Thestudyfurtherstatesthatnativedepositswereobservedextendingtothemaximumexplorationdepthofeightfeetbelowexistinggrades.Groundwaterseepagewasencounteredatthemajorityofthetestpitlocations,rangingindepthsofapproximately1.5to4feetbelowexistinggrades.Thestudystatesthatslopespresenton-sitearegenerallybelow10percentinclination,andthereforebasedonRMC4-3-050G.5.b,thesiteisidentifiedasapotentiallowlandslidehazard,ratherthanamoderatelandslidehazardidentifiedincityrecords.Inaddition,thestudyreferencedthetopographicsurveyandverifiedthatnosensitiveslopes,basedontheRMCdefinitionofsensitiveslope,werepresenton-site.Noindicationsofslopeinstability,currentorpast,wereobservedaspartoftheMarch2017fieldwork.Thestudyconcludesthattheproposeddevelopmentwillnotadverselyaffectthestabilityofthesiteorsurroundingparcels,andthatneitherabufferorbuildingsetbackarenecessaryfortheproject.Thegeotechnicalstudywillneedtobesubmittedwithconstructionandbuildingpermitapplication.Thestudyprovidesrecommendationsincluding,butnotlimitedto,erosioncontrol,stripping,subgradepreparation,foundations,anddrainage.Staffrecommendsasaconditionofapproval,thatprojectconstructioncomplywiththerecommendationsfoundinthegeotechnicalengineeringstudycompletedbycompletedbyEarthSolutionsNW(ESNW),LLC.(datedMay18th,2017)forthesubdivision.STAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEVEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page11of1717.CompliancewithSubdivisionRegulations:RMC4-7Providesreviewcriteriaforthesubdivisions.Theproposalisconsistentwiththefollowingsubdivisionregulationsifallconditionsofapprovalarecompliedwith:ComplianceSubdivisionRegulationsandAnalysisAccess:Eachlotmusthaveaccesstoapublicstreetorroad.AccessmaybebyashareddrivewaypertherequirementsoftheStreetstandards.Themaximumwidthofsingleloadedgaragedrivewaysshallnotexceedninefeet(9’)anddoubleloadedgaragedrivewaysshallnotexceedsixteenfeet(16’).StaffComment:Alongthewestpropertyline,theapplicantisproposinga24footby100.04foot(2,401SF)rectangulartractwitho16-footwidepovedshareddrivewaytoserveLotsIand2fromParkAveN.Accesstoeachofthelotswouldbegainedviatheproposedshareddriveway(TractA).StaffrecommendsaconditionofapprovalstatingthatLot1shallhavevehicleaccessfromthenewshareddriveway,andnotfromParkAveN.ThisconditionshallberecordedonthefaceoftheFinalPlot.Theproposedsharedoccessdoesnotmeettherequirementsforemergencyservices.Firedepartmentapparatusaccessroadwaysarerequiredtobeaminimumof20feetwidefullypaved,with25feetinsideand45feetoutsideturningradius.Fireaccessroadwaysshallbeconstructedtosupporta30tonvehiclewith75psipointloading.Therefore,staffrecommends,asaconditionofapproval,thattheapplicanteitherrequestavariancefromtheRentonFireAutharitytoallowa16-footwidefullypavedfirecompliantapparatusaccessroadway,orprovidea20footwidepavedsharedaccessdrivewayforifconditionemergencyvehicles.ofapprovalAlleyaccessisthepreferredstreetpatternforallnewresidentialdevelopmentexceptinismettheResidentialLowDensitylandusedesignation(RC,R-I,andR-4zones).TheCityusesthefollowingfactorstodeterminewhethertheuseofalleysisnotpractical,including:a)Size:Thenewdevelopmentisashortplot;b)Topography:Thetopographyofthesiteproposedfordevelopmentisnotconduciveforanalleyconfiguration;c)EnvironmentalImpacts:Theuseofalleyswouldhavemoreofanegativeimpactontheenvironmentthanastreetpatternwithoutalleys;d)Ifsitecharacteristicsallowfortheeffectiveuseofalleys(RMC4-7-150E.S).TheshortplothaspublicstreetfrontageonParkAveN,andtheuseofalleyswouldnotbecharacteristicoftheneighborhoodorpractical.Theexistingstreetgridwouldnotsupportalleyaccessbeyondtheproposedconstructionoftheaccessdrive(Exhibit2).AsstatedinFOF14,theproposeddrivewaytractdoesnotincludean8-footlandscapedareaalongthepropertylinewiththeadjacentneighbor,asrequiredbyvestedSharedDrivewayLandscapeRequirements.TheapplicantwouldberequiredtorecordanoteanthefaceoftheplotthatexecutesasharedmaintenanceagreementfarequalownershipandmaintenanceresponsibilitiesforimprovementsinTractA.Themaintenanceagreementshalladdressboththeroadwayandthelandscapinginthe8-footlandscapestrip.Aconstructionpermitforfrontageimprovementswouldberequired.N/ABlocks:Blocksshallbedeepenoughtoallowtwotiersoflots.StaffComment:Nablacksarepraposed.Lot5:Thesize,shape,orientation,andarrangementoftheproposedlotscomplywiththerequirementsoftheSubdivisionRegulationsandtheDevelopmentStandardsoftheR-8zoneandallowforreasonableinfillofdevelopableland.AlloftheproposedlotsmeetSTAFFREPORT_MAWEYEVSp(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrotiveReport&DecisionMAWEVEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page12of17therequirementsforminimumlotsize,depth,andwidth.Widthbetweensidelotlinesattheirforemostpoints(i.e.,thepointswherethesidelotlinesintersectwiththestreetright-of-wayline)shallnotbelessthaneightypercent(80%)oftherequiredlotwidthexceptinthecasesof(1)pipestemlots,whichshallhaveaminimumwidthoftwentyfeet(20’)and(2)lotsonastreetcurveortheturningcircleofcul-de-sac(radiallots),whichshallbeaminimumofthirtyfivefeet(35’).StaffComment:AsdiscussedaboveunderFOF14,alllotsmeettheminimumlotdimensionalrequirementsintheR-6zone.Theproposedlotsarerectangularinshape.TheorientationofLotIhasthefrontyardfacingthepublicstreetParkAveN.TheorientationofLot2hasthefrontyardfacingthewestandaccessviaashareddrivewayextendingfromParkAveN.ThebuildingdesignofthenewresidencesonLots1and2wouldbereviewedandapprovedatthetimeofbuildingpermitapplication.Streets:TheproposedstreetsystemshallextendandcreateconnectionsbetweenexistingstreetspertheStreetStandardsoutlinedinRMC4-6-060StreetStandards.StaffComment:TheproposedprojectprovidesaccesstoParkAveN(aCollectorArterialStreet)andTractA(shareddriveway).Existingright-of-way(ROW)widthisapproximately50feet.TomeettheCity’scompletestreetstandardsforCollectorArterialStreets,aminimumrightofwaywidthof83feetisrequired.Dedicationof16.5feetofright-of-waywouldberequiredalongtheprojectfrontage.Theapplicantsubmittedastreetmodificationrequestwiththeprojectapplication.Themodificationrequeststoconformtoamodifiedminorarterialstreetstandard.Themodifiedcollectorarterial/streetstandardhasarightofwaywidthof63feet.Thepavedroadwaywidthis36feetconsistingof2(10foot)travellanes,2(5foot)bikelanesand1(6foot)parkinglane.A0.5footcurb,8footplanter,and5footsidewalkarealongbothsidesofthepavedroadway.ThestreetmodificationhasbeenreviewedbyCitystaffandisrecommendedforapprovaLPleaseseetheStreetModificationCriteriaandAnalysisinFOF18foracompletesummaryoftherequeststaffanalysis,andstaffrecommendation.PaymentofthetransportationimpactfeeisapplicableontheconstructionofthesinglefamilyhousesatthetimeofapplicationforthebuildingpermitThecurrentrateoftransportationimpactfeeis$5,430.85pernewsinglefamilyhouse.Feesaresubjecttochange.Thetransportationimpactfeethatiscurrentatthetimeofbuildingpermitapplicationwouldbelevied.RelationshiptoExistingUses:Theproposedprojectiscompatiblewithexistingsurroundinguses.StaffComment:TheprojectsiteissurroundedbyR-6zonedpropertiesdevelopedwith‘singlefamilyresidencestothenorth,south,eastandwestTheproposalwouldbeinharmonywiththeexistinguses.TheproposedlotsareconsistentwiththeexistingsurroundingdevelopmentpatternintheareaandwouldbeconsistentwiththeComprehensivePlanandZoningCode,whichencouragesresidentialinfilldevelopment18.StreetModificationAnalysis:TheapplicantisrequestinganAdministrativeModificationfromRMC4-6-060F.2,MinimumDesignStandardsforPublicStreetsandAlleys,forParkAvenueNorth(aminorarterial),inordertoconformtoamodifiedminorarterialstreetstandard.Themodifiedcollectorarterialstreetstandardhasarightofwaywidthof63feet,andincludesa0.5-footcurb,8-footplanter,andS-footsidewalkalongbothsidesofthepavedroadway.Thepavedroadwaywidthis36feet,consistingoftwo10-foottravellanes,two5-footbikelanes,andone6-footparkinglane.TheproposalSTAFFREPORTMAWEYEVSP(2) MAWEYEVSHORTPLATLUAI7-000503,SHPL-ACityofRentanDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionOctober10,2017Page13of17iscompliantwiththefollowingmodificationcriteria,pursuanttoRMC4-9-250.Therefore,staffisrecommendingapprovaloftherequestedmodification,asnotedbelow:compliance)StreetModificationCriteriaandAnalysisa.SubstantiallyimplementsthepolicydirectionofthepoliciesandobjectivesoftheComprehensivePlanLandUseElementandthecommunityDesignElementandtheproposedmodificationistheminimumadjustmentnecessarytoimplementthesepoliciesandobjectives.StaffComment:TheCommunityDesignElementhasapplicablepolicieslistedunderaseparatesectionlabeled“PromotingaSafe,Healthy,andAttractiveCommunity”.Thesepoliciesaddresswalkableneighborhoods,safety,andshareduses.Theintentofthepoliciesaretopromotenewdevelopmentwithwalkableplacesthatsupportgridandflexiblegridstreetandpathwaypatterns,andorevisuallyattractive,safe,andhealthyenvironments.Therequestedstreetmodificationisconsistentwiththesepolicyguidelines.b.Willmeettheobjectivesandsafety,function,appearance,environmentalprotection,andmaintainabilityintendedbytheCoderequirements,baseduponsoundengineeringjudgment..StaffComment:TheCity’sPublicWorksTransportationsectionandEconomicDevelopmentsectionhavereviewedParkAvenueNandthesurroundingareaandhavedeterminedthatamodifiedminorarterialstreetsectionismoresuitablefortheportionofParkAvenueNadjacenttothesite.ThedeterminationwasbasedonthefactthattheroadwayisdirectlyadjacenttosinglefamilyresidencesandthereisinsufficientspacebetweentheexistingrightofwayandexistinghomestoexpandtheroadwaysectiontomeettheCollectorarterialstandards.Inaddition,theCity’sTransportationDepartmenthasestablishedacorridorplanforthissectionofParkAvenueN.ThecorridordeterminedbytheCity’sTransportationDepartmentrequiresarightofwaywidthof63feet.Thepavedroadwoysectionis36’‘consistingoftwo10-foottravellanes,two5-footbikelanes,andone6-footparkinglane.A0.5-footcurb,8-footplanter,and5-footsidewalkarerequiredalongeachsideoftheroadway.c.Willnotbeinjurioustootherproperty(ies)inthevicinity.VStaffComment:Therearenoidentifiedadverseimpactstootherpropertiesfromtherequestedmodification.ci.ConformstotheintentandpurposeoftheCode.StaffComment:Seecommentsundercriterione.Canbeshowntobejustifiedandrequiredfortheuseandsituationintended;andVStaffComment:Seecommentsundercriterion‘b’.f.Willnotcreateadverseimpactstootherproperty(ies)inthevicinity.StaffComment:Seecommentsundercriterion‘c’.19.AvailabilityandImpactonPublicServices:ComplianceAvailabilityandImpactonPublicServicesAnalysisSTAFFREPORT_MAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrotiveReport&DecisionMAfl/EYEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page14of17PoliceandFire:PoliceandFirePreventionstaffindicatesthatsufficientresourcesexisttofurnishservicestotheproposeddevelopment;subjecttotheconditionthattheVapplicantprovidesCoderequiredimprovementsandfees.Fireimpactfeesareapplicableattherateof$718.56persinglefamilyunit.Thisfeeispaidattimeofbuildingpermitissuance.Schools:ItisanticipatedthattheRentonSchoolDistrictcanaccommodateanyadditionalstudentsgeneratedbythisproposalatthefollowingschools:HazelwoodElementary,RisdonMiddleSchool,andHazenHighSchool.TheproposedprojectincludestheinstallationoffrontageimprovementsalongtheParkAveNfrontage,includingsidewalks,Anynewstudentsfromtheproposeddevelopmentwouldbebussedtotheirschools.ThebusstopforHazelwoodElementaryislocatedapproximately0.19milesfromtheprojectsiteatLakeWashingtonBlvdNandN38thSt.StudentswouldwalkalongtheeastshoulderofParkAveNtoN3gthST,wheretheywouldcrossthestreettothewestandwalktothewesttothebusstopatLakeWashingtonBlvdN.Theexistingshouldersandsidewalkswouldprovideasafewalkingrouteforstudentstowalktothebusstop.ThebusstopforRisdonMiddleSchoolislocatedapproximately0.12milesfromtheVprojectsiteatN40thStandParkAveN.StudentswouldwalknorthalongtheeastshoulderofParkAveNtoN40thStwherethebusstopislocated.Theexistingshoulderwouldprovideasafewalkingrouteforstudentstowalktothebusstop.Furthermore,frontageimprovementsareanticipatedwitharecentlyapprovedsubdivision,SenzaLakeView(LUA16-000165)alongbothN40thSt.andParkAve.N.Lastly,thebusstopforHazenHighislocatedapproximately0.07milesfromtheprojectsiteatParkAveNandN39thP1.StudentswouldwalknorthalongtheeastshoulderofParkAveNtoN3gthP1wherethebusstopislocated.Theexistingshoulderwouldprovideasafewalkingrouteforstudentstowalktothebusstop.ASchoolImpactFee,basedonnewsingle-familylots,willberequiredinordertomitigatetheproposal’spotentialimpactstotheRentonSchoolDistrict.ThefeeispayabletotheCityasspecifiedbytheRentonMunicipalCode.Currentlythefeeisassessedat$6,432persinglefamilyresidence.Parks:AParkImpactFeewouldberequiredforthefuturehouses.ThecurrentPark“ImpactFeeis$2,740.07.Thefeeineffectatthetimeofbuildingpermitapplicationisapplicabletothisprojectandispayableatthetimeofbuildingpermitissuance.StormWater:Anadequatedrainagesystemshallbeprovidedfortheproperdrainageofallsurfacewater.StaffComment:APreliminaryTechnicalInformationReport(TIR;Exhibit6),datedJune28,2017,preparedbyEncompassEngineeringandSurveying,wassubmittedwiththeshortplatapplicationmaterials.BasedontheCityofRenton’sflowcontrolmap,thesitefallswithinthePeakRateFlowControlStandardareamatchingExistingSiteConditionsandiswithintheMayCreekDrainageBasin.ThedevelopmentissubjecttoFullDrainageReviewinaccordancewiththe2017RentonSurfaceWaterDesignManual(RSWDM).AllninecorerequirementsandthesixspecialrequirementshavebeendiscussedintheTm.Thereiscurrentlya12-inchstormwatermainlocatedontheonthewestsideoftheproperty.Theshortplatwillberequiredtomaketheconnectionoftheexistingculverttomatchthe12-inchstormdrain.TheapplicantwillneedtoshowtheproposedperforatedpipeconnectiontotheCityofRentonsurfacewatersystem.Inaddition,theapplicantwillneedtoaddresstheuseofBestManagementPractices(BMPs)forthefrontageimprovementsandshareddrivewaytract.AppropriateindividuallotflowcontrolBMPsSTAFFREPORTMAWEYEVSP(2) CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEYEVSHORTPMTLUAI7-000503,SHPL-AOctober10,2017Page15of17willberequiredtohelpmitigatethenewrunoffcreatedbythisdevelopmentThefinaldrainageplananddrainagereportmustbesubmittedwiththeutilityconstructionpermitapplication.Ageotechnicalengineeringstudy,datedMay18th,2017,completedbyEarthSolutionsNW(ESNW),LLC,wasprovidedwiththeapplication.Thesoilsclassificationpresentedinthegeotechnicalreportclassifiedthesoilsasprimarilyloosetodensesiltysandandsandysilt.AnESNWrepresentativesampledfourtestpitsforthepurposesofassessingandclassifyingsubsurfacesoilandgroundwaterconditions.Thestudyconcludedthatthenativedepositspresentonsiteshouldnotbeconsideredfeasibleforinfiltrationfacilitydesign.Thestudystatesthatitispossiblethatdispersionmayprovefeasibleasameansofstormwatermanagement,providedthatanadequateflowpathbeestablishedforimpervioussitesurfaces,andifsuchareascannotbeestablished,canventionolmeansofstormwatermanagementwillprovenecessaryforthedevelopment.Asurfacewaterdevelopmentfeepernewsinglefamilyresidencewouldapply.The2017Surfacewatersystemdevelopmentfeeis$1,608.00foreachnewlot.Thisissubjecttofinaldesignandpayablepriortoissuanceoftheutilityconstructionpermit.Water:WaterserviceisprovidedbyCityofRenton.TheprojectsiteiswithintheCityofRenton’swaterserviceareaintheKennydale320pressurezone.Thereisanexisting12-inchCitywatermainlocatedinParkAveN,whichcandeliverapproximately4,600gallonsperminute(gpm).Thefireflowrequirementforasinglefamilyhomeis1,000gpmminimumfordwellingsupto3,600squarefeet(includinggarageandbasements).Ifthedwellingexceeds3,600.squarefeet,aminimumof1,500gpmfireflowwouldberequired.Aminimumofonefire/hydrantisrequiredwithin300-feetoftheproposedbuildingandtwohydrantsifthefireflowgoesupto1,500gpm.Therearenoexistinghydrantswithin300-feetoftheproposedhome.Aminimumofonenewfirehydrantwillberequiredtobeinstalledneartheentrancetotheproposeddrivewaytomeetminimumstandards.Thedevelopmentissubjecttoawatersystemdevelopmentcharge(SDC)fee.TheSDCfeeforwaterisbasedonthesizeofthenewdomesticwatertoservetheproject.The2017waterfeeforasingle1-inchmeterinstallis$3,486.00permeter.Eachlotshallhaveaseparatemeter.SanitarySewer:SewerserviceisprovidedbyCityofRenton.Thereisanexisting8-inchwastewatermainlocatedonthewestsideoftheproperty.Thereisoneexistingsewerstubinstalledontotheproperty.Thedevelopmentissubjecttoawastewatersystemdevelopmentcharge(SDC)fee.SDCfeeforsewerisbasedonthesizeofthenewdomesticwatertoservetheprojectThe2017sewerfeefora1-inchmeterinstollis$2,540.00permeter.Eachlotshallhaveaseparatemeter.[i.CONCLUSIONS:1.ThesubjectsiteislocatedintheResidentialMediumDensity(MD)ComprehensivePlandesignationandcomplieswiththegoalsandpoliciesestablishedwiththisdesignation,seeFOF13.2.ThesubjectsiteislocatedintheR-6zoningdesignationandcomplieswiththezoninganddevelopmentstandardsestablishedwiththisdesignationprovidedtheapplicantcomplieswithCityCodeandconditionsofapproval,seeFOF14.3.TheproposedShortPlatcomplieswiththeResidentialDesignandOpenSpaceStandardsprovidedtheapplicantcomplieswithCityCodeandconditionsofapproval,seeFOF15.STAFFREPORTMAWEYEVSP(2) CityofRentonDeportmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAfl/EVEVSHORTPLATLU417-000503,SHPL-AOctober10,2017Page16of174.TheproposedShortPlatcomplieswiththeCriticalAreasRegulationsprovidedtheapplicantcomplieswithCityCodeandconditionsofapproval,seeFOP16.5.TheproposedShortPlatcomplieswiththesubdivisionregulationsasestablishedbyCityCodeandstatelawprovidedalladvisorynotesandconditionsarecompliedwith,seeFOE17.6.TheproposedShortPlatcomplieswiththestreetstandardsasestablishedbyCityCodeandthemodificationrequestsupportedbystaff,providedtheprojectcomplieswithalladvisorynotesandconditionsofapprovalcontainedherein,seeFOF17and18.7.Therearesafewalkingroutestotheschoolbusstops,seeFOF19.8.ThereareadequatepublicservicesandfacilitiestoaccommodatetheproposedShortPlat,seeFOE19.jIDECISION:TheMatveyevShortPlat,FileNo.LUA17-000503,asdepictedinExhibit2,isapprovedandissubjecttothefollowingconditions:1.Theapplicantshallsubmitafinaldetailedlandscapeplanthatincludestherequiredshareddrivewaytractlandscaping,requiredfrontyardtreesforLot2,andcomplieswithRMC4-8-120D.12atthetimeofutilityconstructionpermitapplicationtothecurrentplanningprojectmanagerforreviewandapprovalpriortoconstructionpermitissuance.2.Theapplicantshallsubmitforademolitionpermitfortheexistingresidenceandallrequiredinspectionsshallbecompletedpriortotheapprovalofthefinalshortplat.3.Theapplicantshallsubmitafinaldetailedlandscapeplanshowingtwo(2)additionaltreesonLot1inordertomeettheminimumtreedensityrequirementsofthree(3)trees.Onsitelandscapingshillbeinstalledpriortofinaloccupancyfortheindividualhomesandlandscapingwithintheright-of-wayshallbeinstalledpriortoshortplatrecording.4.TheapplicantshalleitherrequestavariancefromtheRentonFireAuthoritytoallowa16-footwidefullypavedfireapparatusaccessroadway,orprovidea20footwidepavedsharedaccessdrivewayforemergencyvehicles.5.TheapplicantshallrecordanoteonthefaceoftheplatthatexecutesasharedmaintenanceagreementforequalownershipandmaintenanceresponsibilitiesforimprovementsinTractA.Adraftversionofthesharedmaintenanceagreementshallbesubmittedforreviewandapprovalbythecurrentplanningprojectmanagerpriortoshortplatrecording.6.ItshallberecordedonthefaceoftheshortplatthatLotIvehicleaccessshallbeexclusivelyfromtheshareddriveway(TractA)anddirectaccesstoParkAve.Nshallnotbepermitted.7.ProjectconstructionshallcomplywiththerecommendationsfoundinthegeotechnicalengineeringstudycompletedbycompletedbyEarthSolutionsNW(ESNW),LLC.(datedMay18th,2017)forthesubdivision.DATEOFDECISIONONLANDUSEACTION:SIGNATURE:_______________________________________________October1012017JenniferHenning,PlanningDirectorDateSTAFFREPORT_MAWEYEVSP(2) CityofHentonDeportmentofCommunity&EconomicDevelopmentAdministrativeReport&DecisionMAWEYEVSHORTPLATLUAI7-000503,SHPL-AOctober10,2017Page17of17TRANSMITTEDthis10thdayofOctober,2017totheOwner/Applicant/Contact:Owner:Applicant:EmilMotveyevNicoleMecum807KirklandWayEncompassEngineering&SurveyKirkland,WA98033165NEJuniperSt.Suite201lssaquah,WA98027TRANSMITTEDthisdayofOctober,2017tothePartiesofRecord:CyrusMcNeelySamuelRobbins116102lOthAveE3900PorkAveNBonneyLake,WA98391Renton,WA98056TRANSMITTEDthislOdayofOctober,2017tothefollowing:ChipVincent,CEDAdministratorBrionneBonnwarth,DevelopmentEngineeringManagerAmandaAskren,PropertyServicesVanessaDolbee,CurrentPlanningManagerFireMarshalK.LANDUSEACTIONAPPEALS,REQUESTFORRECONSIDERATION,&EXPIRATION:Theadministrativelandusedecisionwillbecomefinalifthedecisionisnotappealedwithin14daysofthedecisiondate.APPEAL:ThisadministrativelandusedecisionwillbecomefinalifnotappealedinwritingtotheHearingExamineronorbefore5:00PMonOctober24,2017.Anappealofthedecisionmustbefiledwithinthe14-dayappealperiod(RCW43.21.C.075(3);WAC197-11-680),togetherwiththerequiredfeetotheHearingExaminer,CityofRenton,1055SouthGradyWay,Renton,WA98057.RMC4-8-110.BgovernsappealstotheHearingExaminerandadditionalinformationregardingtheappealprocessmaybeobtainedfromtheCityClerk’sOffice,(425)430-6510.SHORTRATEXPIRATION:Theadministrativeshortplatdecisionwillexpiretwo(2)yearsfromthedateofdecision.Asingleone(1)yearextensionmayberequestedpursuanttoRMC4-7-070.M.MODIFICATIONEXPIRATION:TheModificationdecisionwillexpiretwo(2)yearsfromthedateofdecision.Asingleone(1)yearextensionmayberequestedpursuanttoRMC4-9-250.RECONSIDERATION:Within14daysofthedecisiondate,anypartymayrequestthatthedecisionbereopenedbytheapprovalbody.Theapprovalbodymaymodifyhisdecisionifmaterialevidencenotreadilydiscoverablepriortotheoriginaldecisionisfoundorifhefindstherewasmisrepresentationoffact.Afterreviewofthereconsiderationrequest,iftheapprovalbodyfindssufficientevidencetoamendtheoriginaldecision,therewillbenofurtherextensionoftheappealperiod.Anypersonwishingtotakefurtheractionmustfileaformalappealwithinthe14-dayappealtimeframe.THEAPPEARANCEOFFAIRNESSDOCTRINE:providesthatnoexparte(privateone-on-one)communicationsmayoccurconcerningthelandusedecision.TheDoctrineappliesnotonlytotheinitialdecision,buttoAppealstotheHearingExamineraswell.Allcommunicationsafterthedecision/approvaldatemustbemadeinwritingthroughtheHearingExaminer.Allcommunicationsarepublicrecordandthispermitsallinterestedpartiestoknowthecontentsofthecommunicationandwouldallowthemtoopenlyrebuttheevidenceinwriting.AnyviolationofthisdoctrinecouldresultintheinvalidationoftheappealbytheCourt.STAFFREPORT_MAWEYEVSP(2) RECEIVED 07/26/2017 aweihs PLANNING DIVISION EXHIBIT 2 EXHIBIT 3 Arborist Report 3810 Park Ave N Renton, WA March 9th, 2017 RECEIVED 07/26/2017 aweihs PLANNING DIVISION EXHIBIT 4 #10514" DEC.12" DEC.RECEIVED07/26/2017 aweihsPLANNING DIVISIONEXHIBIT 5 RECEIVED 07/26/2017 aweihs PLANNING DIVISION EXHIBIT 6 Entire Document Available Upon Request EXHIBIT 7 EarthSolutionsNWLLC EarthSolutionsNWLLC Geotechnical Engineering Geology Environmental Scientists Construction Monitoring 1805 -136th Place N.E.,Suite 201 Bellevue,WA 98005 (425)449-4704 Fax (425)449-4711 www.earthsolutionsnw.com GEOTECHNICAL ENGINEERING STUDY PROPOSED SHORT PLAT 3810 PARK AVENUE NORTH RENTON,WASHINGTON ES-5134 RECEIVED 07/26/2017 aweihs PLANNING DIVISION EXHIBIT 8 Entire Document Available Upon Request DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT DENSITY WORKSHEET Planning Division 1055 South Grady Way-Renton, WA 98057 Phone: 425-430-7200 | www.rentonwa.gov 1.Gross area of property square feet 2.Deductions: Certain areas are excluded from density calculations. These include: Public Streets* square feet Private access easements* square feet Critical Areas** square feet Total excluded area: square feet 3.Subtract line 2 (total excluded area) from line 1 for net area square feet 4.Divide line 3 by 43,560 for net acreage acres 5.Number of dwelling units or lots planned units/lots 6.Divide line 5 by line 4 for net density = dwelling units/acre *Alleys (public or private) do not have to be excluded. **Critical Areas are defined as “Areas determined by the City to be not suitable for development and which are subject to the City’s Critical Areas Regulations including very high landslide areas, protected slopes, wetlands, or floodways.” Critical Areas buffers are not deducted/excluded. 1 H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\density.doc Rev: 08/2015 RECEIVED 07/26/2017 aweihs PLANNING DIVISION EXHIBIT 9 F’rarIn1cD:,St,,.çsAI(S-II-c(TIc)•N-4NPr7Ic•c\—i—S*N)\ThIStCt’INI2C-LArC?EXHIBIT 10 AngeleaWeihsFrom:AngeleaWeihsSent:Thursday,September28,20173:47PMTo:cmikeathom@msn.com’Subject:MatveyevShortPlat;LUA17-000503Attachments:RS_GeotechReport_Matveyev_170726.pdf;TR_ArboristReport_Matveyev_170726.pdfHelloMr.McNeely,Thankyouforyourcommentsregardingtheaccessorystructurelocatedat3810ParkAveN.Yourcommentswillbetakenintoconsideration.Pleaseseetheattachedarboristreportandgeotechnicalreportperyourrequest.Letmeknowifyouhaveanyadditionalquestions,AngeleaWeihsAssociatePlanner,CityofRenton10555.GradyWayRenton,WA98057(425)430-73121EXHIBIT 11 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 2 LUA17-000503 ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Angelea Weihs, 425-430-7312, aweihs@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division’s approval of this work is required prior to final inspection and approval of the permit. 4. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained. 5. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the applicant shall provide supervision whenever equipment or trucks are moving near trees. 6. This permit shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and /or your U.S. Fish and Wildlife Service permit. Development Engineering: (Contact: Justin Johnson, 425-430-7291, jtjohnson@rentonwa.gov) 1. See Attached Development Engineering Memo dated August 24, 2017 Fire Authority: (Contact: Corey Thomas, 425-430-7024, cthomas@rentonwa.gov) 1. See Attached Renton Fire Authority Memo dated August 17, 2017 EXHIBIT 12 ADVISORY NOTES TO APPLICANT Page 2 of 2 LUA17-000503 Community Services: (Contact: Leslie Betlach, 425-430-6619, lbetlach@rentonwa.gov) 1. Parks Impact Fees per Ordinance 5824 shall be paid. Building: (Contact: Craig Burnell, 425-430-7290, cburnell@rentonwa.gov) 1. Recommendations of the geotechnical report must be followed as a condition of building permits. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: August 24, 2017 TO: Angelea Weihs, Planner FROM: Justin Johnson, Civil Engineer II, Plan Review SUBJECT: Matveyer Short Plat Pre-App 3810 Park Ave N LUA17-000503 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non- binding and may be subject to modification and/or concurrence by official City decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel(s) 3342700510. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1. The project is within the City of Renton’s water service area in the Kennydale 320 pressure zone. 2. There is an existing 12-inch City water main located in Park Ave N (see Water plan no. W-230519 which has a static water pressure of approximately 81.7 psi at elevation 130) which can deliver approximately 4600 gallons per minute (gpm). Site requires a pressure reducing values if the water pressure is greater than 80 psi. 3. There is an existing ¾” water meter serving the existing home off of Park Ave N. 4. Contractor needs to show how they plan to provide water service to lot 2 5. The site is located outside of an Aquifer Protection Area. 6. The development is subject to a water system development charge (SDC) fee. The SDC fee for water is based on the size of the new domestic water to serve the project. The2017 water fee for a single 1-inch meter install is $3,486.00 per meter. Each lot shall have a separate meter. 7. Adequate horizontal and vertical separations between the new water main and other utilities (storm sewer pipes and vaults, sanitary sewer, power, gas, electrical) shall be provided for the operation and maintenance of the water main. LUA17-000503 Matveyer Short Plat Page 2 of 3 SEWER 1. Sewer service is provided by City of Renton. 2. There is an existing 8-inch wastewater main located on the west side of the property (Record Drawing: S-014207) 3. There is one existing sewer stub installed onto the property. 4. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. The 2017 sewer fee for a 1-inch meter install is $2,540.00 per meter. Each lot shall have a separate meter. SURFACE WATER 1. There are no existing stormwater facility onsite. 2. There is currently a 12 in storm water main located on the on the west side of the property. Short plat shall be required to make the connection of the existing culvert to matching 12 inch storm drain. 3. Applicant will need to show the purposed perforated pipe connection to the City of Renton surface water system. 4. Applicant will need to address the use of BMPs for the frontage improvements and shared driveway tract. 5. Appropriate individual lot flow control BMPs will be required to help mitigate the new runoff created by this development. The final drainage plan and drainage report must be submitted with the utility construction permit application. 6. The 2017 Surface water system development fee is $1,608.00 for each new lot. This is payable prior to issuance of the construction permit. TRANSPORTATION 1. The proposed development fronts Park Ave N along the west property line(s). Park Ave N is classified as a Collector Arterial Road. Existing right-of-way (ROW) width is approximately 50 feet. To meet the City’s complete street standards for collector arterial streets, minimum right of way width is 83 feet. Dedication of 16.5 feet of right of way would be required. However, the City’s transportation group has determined and will support an alternate standard to match the established street section for Park Ave N. The City established street section for Park Ave N, which shall be installed by the developer as part of the proposed short plat, will allow a pavement width of 36-feet, 8 foot planting strips, 5-foot sidewalks, and 0.5-foot curb. This recommendation results in a total right of way width of 63 feet, requiring 6.5-feet of ROW dedication. Applicant has submitted an application to the City requesting a modification of the street frontage improvements as outlined in City code 4-9-250C5d. 2. Refer to City code 4-6-060J regarding shared driveway regulations. a. Shared driveways may be allowed for access to four (4) or fewer lots provided: i. At least one of the four (4) lots abuts a public right-of-way with at least fifty (50) linear feet of property; and ii. The shared driveway is no more than 200 feet in length; and b. The shared driveway would be required to provide a turn-around in accordance with RMC 4-6-060H. 3. Payment of the transportation impact fee is applicable on the construction of the single family houses at the time of application for the building permit. The 2017 rate of transportation impact LUA17-000503 Matveyer Short Plat Page 3 of 3 fee is $5,430.85 per single family house. The transportation impact fee that is current at the time of building permit application will be levied, payable at building permit issue. GENERAL COMMENTS 1. All construction or service utility permits for drainage and street improvements will require separate plan submittals. All utility plans shall conform to the Renton Drafting Standards. Plans shall be prepared by a licensed Civil Engineer. 2. When utility plans are complete, please submit four (4) copies of the drawings, two (2) copies of the drainage report, one (1) complete electronic submittal (drawings and drainage report), the permit application, an itemized cost of construction estimate, and application fee at the counter on the sixth floor. 3. All sewer stubs, water services and storm connections are required to be provided to each lot prior to recording of the short plat. 4. Fees quoted in this document reflect the fees applicable in the year 2017 only and will be assessed based on the fee that is current at the time of the permit application. 5. All utilities serving the site are required to be undergrounded. 6. Survey shall be required due the property line conflict on the east side of the lot. FIRE & EMERGENCY SERVICES DEPARTMENT M E M O R A N D U M DATE: August 17, 2017 TO: Angela Weihs, Associate Planner FROM: Corey Thomas, Plans Review Inspector SUBJECT: Matveyev Short Plat Environmental Impact Comments: 1. The fire impact fees are currently applicable at the rate of $718.56 per single family unit. Credit will be granted for the retention of the one existing home. Fee is paid at time of building permit issuance. Code Related Comments: 1. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed building and two hydrants if the fire flow goes up to 1,500 gpm. There are no existing hydrants within 300-feet of the proposed home. A minimum of one new fire hydrant will be required to be installed near the entrance to the proposed driveway. 2. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45- feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. The proposed 16-foot wide roadway is not acceptable. If applicant seeks a variance to 16-feet wide road with the condition that all future homes are to be equipped with an approved fire sprinkler system, then they need to do so. No variance request has been received by the Renton Fire Authority.