Loading...
HomeMy WebLinkAboutT-404311Y (n W a Z g i Q O O N O N 1-11 00 N O_ ry w Q U L_ 0 U L I 41 a) U) c v Q U) 0 Q c .21 U) a� 0 rn O O O O `U 6 U) a) 41 3 0 U) a) c a� v c 0 c a� L L0 z 0 z w ry 1-1 DOMINANDOR AND MYRNA RAMOS #214480-0875 4 ,- 2 RENTON AVE S row 110 ; ! loll `\ D D — / -�./ \ i / �/, / JESSICA/AND DONOVAN S / SYDOW #214480-0206 000, / s -' "\— 1 / — C' � EX. MH / //� �\ STA.=107 CJ 00- 00- + / / c, 41 ,,000�� zzlol o loll Ile � / � / / o � FRED YOUNG c� / #214480-0306 S / a. D / A_IN HAO PHAM #214480-0865 2 4 12.4:�;::�°�k ---- - -- RENTON AVE S-- - 0 5 3 .:t . CO ~ ,' - X X Q d o I i i MARCIA LEON AND ANN WAN RICK LI #214480-0887 #214480-0890 i WILBUR REPP #214480-0880 RENTON AVE S Aw -------------------------------- --- 2 3 12" CC STORM 4 1 2 4 2 5 5 3 •- d ' _ 4 .-. 1» CO P _ x w m =L 11 U) O— —-------------- W W g DI w 5 �,♦ -- W -- W W -- � -- _ _ -- — \ — c� \ _ 38 I-00 \ STA "35+82.1, 17.8' LT 37+0_ �� \ — 1 8 X8 VERTICAL CROSS FOR POLYPIGGING I--—1—CONC. THRUSH BLOCK — \ _ U)� T \� SEE STD. PLAN NO. 300.6 (SHEET 12/WD-2) N — — m � U3 G ` T 2" G — _ m G G G��T G G\ G \ \ r T \ \ T -- \ "N \ \ \ CITY OF RENTON #214480-0867 71 ANN WAN 4214480-0887 ABANDONED 4" GAS 3" COVER 12" CC STORM 1 4 i :/ I , V\ / O/ 4" GAS 3.3' COVE O / s' —w — w w ©WA© 9Mi 4' COVER SHUT CORP STOP TO ABANDON 2" GALV SERVICE w �w W % 8 DI W yy — - STA 41 +02.8, 17.8' LT \ — 5 CONNECT TO EXIST. 10" WATER MAIN: c5 41+QO 1-10"X8" TAPPING TEE (MJXFL) 1-8" TAPPING VALVE (FLXMJ) — \ — 40 i 00 — SEE STD. PLAN N0. 300.1 (SHEET 11/WD-1 CUT AND REMOVE EXISTING STEEL CASING AS \ \ — REQUIRED TO PERFORM WET —TAP ON — #—Go J_ — G G Z i EXISTING 10" WATER MAIN G `( G G —�— G 3 in W C) \ c w w C 0 -0 00 \ \ EDWARD GIESLER I �— / \ #214480-0866 \ `� MADELEINE AND JOHN MOORE \ \ \ #214480-0868 \\ \ \ WATER PLAN NOTES 1. FURNISH AND INSTALL FIRE HYDRANT ASSEMBLY AND HYDRANT MARKER PER CITY OF RENTON STD PLAN 310.1 AND 310.3. SEE SHEET 12/WD-2. HYDRANT SHALL BE INSTALLED 18" MIN. BEHIND THE SIDEWALK. 2• FURNISH AND INSTALL 1" WATER SERVICE TO INCLUDE CONNECTION TO PRIVATE WATER SERVICE LINE PER CITY OF RENTON STD PLAN 320.1. SEE SHEET 11/WD-1. 3. EXISTING 1" COPPER WATER MAIN SHALL BE ABANDONED PER THE SPECIFICATIONS. 4. CAUTION POTENTIAL UTILITY CONFLICT. CONTRACTOR SHALL PROTECT EXISTING WATERLINE UNTIL THE NEW WATERLINE IS COMPLETE AND SERVICES ARE TRANSFERRED. 5. CAUTION POTENTIAL UTILITY CONFLICT. CONTRACTOR TO PROTECT EXISTING UTILITY. T-404311 20' 10' 0 20' 40' 0 in 2" SCALE: 1 "=20' TWO INCHES AT FULL SCALE. IF NOT, SCALE ACCORDINGLY U W W O z z W Z J U) z 0 0 m 0 N 0 D is w Q Y z O li.l 0 U Q 0 a a a w a c Z 0 £o _2 � c > 0 N L5 m a N Z 0 0 L) Nw LL N j w � =' W O U) m W W N Qj 0 m m v Y U U (n(n 0 z z_ 0 LL o z 3 Lu 0 w z Z = W a 0 w LL � W O < z ? z 0 U ; � Q Z Z Y 0 z Lu SHEET: 1 01WP-1 OF: 70 JOB NO.: 17534 DWG: WATER