Loading...
HomeMy WebLinkAboutT-404348GENERAL, NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2018 WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION AND ITS AMENDMENTS, SPECIAL PROVISIONS, WSDOT STANDARD PLANS, CITY OF RENTON STANDARD PLANS, AND NATIONAL ELECTRICAL CODE, ALL CURRENT VERSIONS. 2. USE CITY OF RENTON STANDARD PLAN 138.1 FOR SIGNAL HEAD DETAILS, SIGNAL SEQUENCE AND OTHER GENERAL NOTES, EXCEPT SIGNAL HEAD ASSIGNMENT NOTE #2 SHALL STATE MOUNTING TYPE "E" INSTEAD OF MOUNTING TYPE "D". 3. USE CITY OF RENTON STANDARD PLAN 138.2 FOR WIRING DIAGRAM. NOTE PEDESTRIAN SIGNAL HEAD 28 IS MOUNTED ON POLE #1 (NOT POLE #2 AS SHOWN ON 138.2). NOTE PEDESTRIAN SIGNAL HEAD 29 IS MOUNTED ON POLE #4 (NOT POLE #3 AS SHOWN ON 138.2). WIRING SHALL BE ADJUSTED ACCORDINGLY. 4. USE CITY OF RENTON STANDARD PLAN 138.3 FOR SIGNAL POLE DETAILS. NOTE SIGNAL POLE #4 IS A TYPE II (NOT A TYPE III AS SHOWN ON 138.3). SEE ALSO SHEET TS3. 5. REFER TO SHEET TS2 FOR ENLARGEMENTS OF EACH END OF PEDESTRIAN CROSSING, WIRING SCHEDULE AND SIGNING DETAILS. 6. APS PUSH BUTTON ASSEMBLIES SHALL BE POLARA I —NAVIGATOR MODEL IN2 WITH 9"X15" R10-3E SIGNS. 7. ALL CONDUIT CROSSING ROADWAYS SHALL BE DIRECTIONALLY DRILLED HDPE. 8. REFER TO CHANNELIZATION PLAN SHEETS FOR POST --MOUNTED TRAFFIC SIGNS. 9. CONTRACTOR SHALL INSTALL 48"X48" W20-902 "NEW SIGNAL AHEAD" SIGNS ON 4"X4" TREATED TIMBER POSTS WITH TWO ORANGE FLAGS EACH AT THREE LOCATIONS STAKED BY ENGINEER. REMOVE SIGNS, FLAGS AND POSTS 30 DAYS AFTER SYSTEM TURN —ON. EXISTING 0 m N 0 00 U Cf)i V) i 0 0 0 U) U Qa 0 z i 17+00 18+ CONSTRUCTION NOTES V Z (D CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE, SIGNAL HEADS, EVP DETECTOR, TERMINAL CABINET, LED LUMINAIRE AND TRAFFIC � SIGNS. USE CITY OF RENTON STANDARD PLANS 138.1, 138.2, 138.3 AND WSDOT STANDARD PLANS J-26.10-03, J-26.15-01. w O2 CONSTRUCT CURB TYPE FOUNDATION AND INSTALL TYPE PPB SIGNAL POLE AND APS PEDESTRIAN PUSH BUTTON ASSEMBLY. USE CITY OF W Z RENTON STANDARD PLANS 138.1, 138.2 AND WSDOT STANDARD PLANS J-20.11-02, J-20.26-01. V i O3 NOT USED. Z W 4 CONSTRUCT FOUNDATION AND INSTALL TYPE II SIGNAL POLE, SIGNAL HEADS, TERMINAL CABINET AND TRAFFIC SIGNS. USE CITY OF RENTON STANDARD PLANS 138.1, 138.22 138.3 AND WSDOT STANDARD PLANS J-26.10-03, J-26.15-01. U 5CONSTRUCT CONTROLLER FOUNDATION AT STA. 18+26.5, 33.5 RT. INSTALL TYPE M STRETCH SIGNAL CONTROLLER CABINET WITH FRONT U. DOOR FACING SOUTHWEST. INSTALL BATTERY BACKUP SYSTEM, SIEMENS M62 ATC CONTROLLER WITH FIRMWARE HAWK 10 3.34G (OR Q GREATER), POLARA I —NAVIGATOR CONTROLLER AND ASSOCIATED EQUIPMENT. USE CITY OF RENTON STANDARD PLAN 126.1. ce O INTERCEPT EXISTING STREET LIGHTING CONDUIT AND SWEEP INTO NEW TYPE 8 JUNCTION BOX. RE —WIRE EXISTING STREET LIGHTING CIRCUIT PER WIRING SCHEDULE. INSTALL NEW CONDUCTORS PER WIRING SCHEDULE. Z O7 DISCONNECT EXISTING STREET LIGHTING CONDUCTORS IN EXISTING JUNCTION BOX AND REMOVE CONDUCTORS TO SOUTH INTERCEPT POINT. SPLICE NEW CONDUCTORS TO EXISTING CONDUCTORS IN JUNCTION BOX. REFER TO WIRING SCHEDULE. � O8 ROUTE NEW POWER CONDUCTORS THROUGH EXISTING STREET LIGHTING CONDUIT TO EXISTING SERVICE CABINET LOCATED AT APPROXIMATE W STA. 198+00, LT. TERMINATE CONDUCTORS ON EXISTING SIGNAL CIRCUIT BREAKER AND NEUTRAL BAR. _ 9 COORDINATE WITH PUGET SOUND ENERGY FOR RELOCATION OF OVERHEAD POWER LINES TO PROVIDE TEN FEET OF CLEARANCE TO LUMINAIRE POLE AND LUMINAIRE. INSTALL FOUNDATION AND ARTERIAL STREET DECORATIVE LUMINAIRE POLE WITH LED ROADWAY LUMINAIRE ON 8' MAST ARM. USE CITY OF RENTON STANDARD PLANS 117.1, 117.31 119, 120, 121, 124, 125 AND 8' FOUNDATION DEPTH. 10 INSTALL WIRELESS INTERCONNECT EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. RADIO UNIT SHALL BE INSTALLED IN CONTROLLER CABINET. ANTENNA WITH MOUNTING SHALL BE INSTALLED ON SIGNAL MAST ARM OF SIGNAL STANDARD #1. SEE SHEET TS3. 3 12' DI � 14 � 15 28, x r _ 20+00 G a U z O 00 �c A13 0 ; /; o 9 15 /r o ----► VEHICLE SIGNAL HEAD o / "'5/-► PEDESTRIAN SIGNAL HEAD / -0 PREEMPTION DETECTOR 14 o` ! tK -cn APS PEDESTRIAN PUSH BUTTON ASSEMBLY `b / UTILITY POLE AND LUMINAIRE 8 0-0 DECORATIVE LIGHT POLE AND LUMINAIRES) / ® DECORATIVE SIGNAL POLE, TYPE PPB DECORATIVE SIGNAL POLE, TYPE II / / / / C1? DECORATIVE SIGNAL POLE, TYPE III i oOX� / Q TYPE 1 JUNCTION BOX, J-40.10-04 TYPE 2 JUNCTION BOX, J-40.10-04 r% / TYPE 8 JUNCTION BOX, J 40.30 04 / -------- CONDUIT / ® CONTROLLER CABINET, COR 126.1 / SIGNAL —MOUNTED TRAFFIC SIGN, COR 132.0 / CONSTRUCTION NOTE SIGNAL POLE NO. WIRE NOTE LEGEND 3 21 +00 G G G �i DS D 20 0 20 40 scale feet T 404348 APPROVED FOR BID CITY OF RENTON DATE APPROVED FOR CONSTRUCTION i2 C6Y OF RENTON DATE m 00 m O v to V 0 v V r cv u v N 4­0rn � Ln O fV un Ln 0 1" 2" TWO INCHES AT FULL SCALE. IF NOT, SCALE ACCORDINGLY U w w ® z z w z z 0 U 00 = z = o Lij o V) o w w > z V o W U Cr <t w C� U Q 0 n Q_ Q w Q c � Z Eo CD N o u� a� N � 0 ❑ m z U m ❑ > O Cn > 0 n cu O o .a m V CL w o u d) u >, 0 z 0 z u Q U. z D z U) O w a z= w F- 4 w LL U 0 w .... w V > c� Q S2 z 0 Z w OC SHEET: 44/TS OF: 70 JOB NO.: 17534 DWG: TS_REV3 U