Loading...
HomeMy WebLinkAboutMFP20000896.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20000896 IVR Number: 20000896 Permit Information Permit Name: Century Link Permits Address/Location:02/13/2020Application Date:1923059080Parcel Number: 200 SW GRADY WAY Permit Type:03/03/2020Issue Date:Franchise Permit Work Class:09/03/2021Expiration Date:Minor Utility Job Number: N.656361Franchise Type:Telephone Description: Revision: Century Link to access MH113, MH110, MH530, MH686, dig up and fix in 3 locations, and replace damaged PED. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Austin Sweeney Century Link Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date QWEST corp d/b/a CenturyLink QC Austin Sweeney 253 766 7549 Austin.sweeney@centurylink.com Northsky Communications 425 615 7121 NORTHSC857Q4 BL.028638 N.656361 200 SW Grady Way Revised to: CenturyLink to access MH113, MH110, MH530, MH686, dig and fix in three(3) locations, and replace damaged Ped. X X X Austin Sweeney 11/6/2020 X X Scott Warlick 12/3/2020 RESTORATION PER CITY OF RENTON STANDARDS MFP20000896 DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering MFP20000896 Scott Warlick CED 12/3/2020 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 11/25/2019 APPLICANT AGREES TO ALL THE FOLLOWING: •TCP must be approved prior to commencing the work, and all permit conditions shall be met. •Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. •Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. •TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. •Approved Temporary TCP must be at the work site during work hours. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. •The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date Austin Sweeney TRAFFIC CONTROL PLAN JOB # N.656361. C.45 PERMIT # LIND AVE SW @ SW GRADY WAY MH 530 RIGHT TURN LANE CLOSURE Legend Work Area Cone Spotter Work Truck Comments: THIS IS TO ACCESS THE MH 530 LIND AVE SW NB RIGHT TURN LANE CLOSURE CROSSWALK REMAINS ACCESSIBLE SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA. SW GRADY WAY SW 12TH STLIND AVE SWROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEAD W20-5 KEEP LEFT R4-8a MH 530WORK AREA10 X 300 ONE LANE TWO WAY TAPER 50' MIN/100' MAX CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 Date:2/6/2020 Author:Kathy Hubbard, Traffic Control Supervisor Project:N.656361.C.45 CERT:TCS # 011905 Designed for CenturyLink:(DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. Designed For: CENTURYLINK Project # N.656361.C.45 Kathy Hubbard Traffic Control Supervisor TCS # 011905 Approved 2/6/2020 Phone 253-737-5198 tcpnd@comcast.net _______________________Kathy Hubbard NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: KATHY HUBBARD, TCS# 011905, tcpnd@comcast.net N SPEEDLIMIT 35 www.invarion.com MFP20000896 TRAFFIC CONTROL PLAN JOB # N. 656361.C.45 PERMIT # Designed For: CENTURYLINK Project # N.656361.C.45 Kathy HubbardTraffic Control Supervisor TCS # 011905Approved 2/6/20 Phone 253-737-5198 tcpnd@comcast.net _______________________Kathy Hubbard Date:2/6/20 Author:Kathy Hubbard, Traffic Control Supervisor Project:N.656361.C.45 CERT:TCS # 011905 Designed for CenturyLink:By Kathy Hubbard (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:KATHY HUBBARD, TCS# 011905, tcpnd@comcast.net Legend Work Area Arrowboard (Chevron) CONES WORK TRUCK ONE LANE TWO WAY TAPER 50' MIN/100' MAX CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE ROADWORKAHEAD W20-1N SW GRADY WAY MAPLE AVE SWRAINIER AVE SRIGHT LANECLOSEDAHEADW20-5ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1W4-2MH 686 WORK AREA 10' X 225' Comments: THIS IS TO ACCESS THE MH 686 LOCATED IN THE RIGHT LANE. THIS WILL BE A RIGHT WESTBOUND LANE. PEDESTRIANS ARE NOT IMPACTED. SW GRADY WAY @ MAPLE AVE SW MH 686 RIGHT LANE CLOSURE www.invarion.com MFP20000896 Not to scaleNOT TO SCALE Date:112/11/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.502347 C.45 CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.502347 C.45 PERMIT # Sharon Martos Project # N.502347 C.45Designed for CenturyLink Sharon MartosApproved 12/11/2019Traffic Control Supervisor TCS # 010745Phone 253-737-5198 sharon.martos@gmail.comROADWORKAHEADW20-1SW 7TH ST @ HARDIE AVE SW MH 113 RIGHT LANE CLOSURE RIGHT LANECLOSEDAHEADW20-5W4-2SW 7TH ST LIND AVE SWComments: ACCESS MH 113. SOUTH SIDE OF SW 7TH ST, WEST OF HARDIE AVE SW. RIGHT LANE CLOSURE. SIDEWALK CLOSED. CURB RAMPED AND NON-SKID STEEL PLATES PLACED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.RRRRDETOURM4-9bDETOURM4-9bDWY ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 DWY DWY DWY ACCESS RDACCESS RD200'200'200'150'HARDIE AVE SWN MH 113WORK AREA 10 X 190 SPEED LIMIT 30 www.invarion.com MFP20000896 1111111111XXXXSW 7TH STSW 7TH ST LIND AVE SWTRAFFIC CONTROL PLAN JOB # N.588158.C.45 PERMIT # Legend WORK AREA WORK TRUCK Arrowboard (Chevron) CONES SPOTTER Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60'25 / 30 20' 40' ONE LANE TWO WAYTAPER 50' TO 100' MAX ONE LANE TWO WAY TAPER 50' MIN/100' MAX Designed for: CENTURYLINK Project # N.588158.C.45Darlene DurrTraffic Control Supervisor TCS # 011915 Approved 9/5/19 Phone 253-737-5198 darlene.durr@hotmail.com _______________________ Date:9/5/19 Author:Darlene Durr, Traffic Control Supervisor Project:N.588158.C.45CERT:TCS # 011915 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Darlene Durr UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com NOT TO SCALE MH 110 SW 7TH ST @ LIND AVE SW MH 110 ACCESS RIGHT LANE CLOSURE Comments: THIS IS TO ACCESS MH 110 LOCATED IN THE SOUTH SIDEWALK OF SW 7TH ST WEST OF LIND AVE SW. THIS IS A RIGHT LANE CLOSURE OF EASTBOUND SW 7TH ST WEST OF LIND AVE SW PEDESTRIANS DETOURED TO 4' PEDESTRIAN PATH AT WORK AREA. 4' PEDESTRIAN PATH WILL MEET ADA STANDARDS. SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.SPEEDLIMIT 30 N DETOURM4-9bDETOURM4-9bWORK AREA 11' X 215ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1RIGHT LANECLOSEDAHEADW20-5W4-2200'200'200' 200' 200' www.invarion.com MFP20000896 Not to scaleNOT TO SCALE Date:05/20/2020 Author:Sharon Martos, Traffic Control Supervisor Project:N.656361 C.45CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone Not to scale Scale Marker S Spotter Work Area Work Truck TRAFFIC CONTROL PLANJOB # N.656361 C.45 PERMIT #N CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 S GRADY WAY @ LIND AVE S DIG and FIX & REPLACE PED RIGHT LANE CLOSURE SPEED LIMIT35 Sharon Martos Project # N.656361 C.45Designed for CenturyLinkSharon MartosApproved 05/20/2020Traffic Control SupervisorTCS # 010745Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Comments: DIG -FIX & REPLACE DAMAGED PEDNORTH SIDE S GRADY WAY, EAST OF LIND AVE S.RIGHT LANE CLOSURE.SIDEWALK CLOSED.CURB WILL BE RAMPED PER ADA REQUIREMENTS TOACCOMMODATE PEDESTRIANS.SPOTTER WILL ASSIST PEDESTRIANS. DWY DETOURM4-9bDETOURM4-9bS PED ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'225' S GRADY WAYLIND AVE SRAINIER AVE SMAPLE AVE Swww.invarion.com MFP20000896 Not to scaleNOT TO SCALE Date:05/20/2020 Author:Sharon Martos, Traffic Control Supervisor Project:N.656361 C.45CERT:TCS # 010745 Designed for CenturyLink:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTONrequirements.2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be ____am to ____pm. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Work Area Work Truck TRAFFIC CONTROL PLANJOB # N.656361 C.45 PERMIT #N CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 S GRADY WAY @ MAPLE AVE S DIG and FIX RIGHT LANE CLOSURE SPEEDLIMIT35 Sharon Martos Project # N.656361 C.45Designed for CenturyLinkSharon MartosApproved 05/20/2020Traffic Control SupervisorTCS # 010745Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com ROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'350'350'225'S GRADY WAY MAPLE AVE SRAINIER AVE SDig & Fix WORK AREA11 X 275 Comments: WORK AREA IN THE WB CURB LANE S GRADY WAY @ MAPLE AVE S.RIGHT LANE CLOSURE. DWY www.invarion.com MFP20000896 TRAFFIC CONTROL PLAN JOB # N.656361. C.45 PERMIT # LIND AVE SW @ SW GRADY WAY DIG / FIX / RESTORE RIGHT TURN LANE CLOSURE Legend Work Area Cone Spotter Work Truck CONES Comments: THIS IS TO DIG FIX AND RESTORE AS REQUIRED. LIND AVE SW NB RIGHT TURN LANE CLOSURE CROSSWALK REMAINS ACCESSIBLE SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA. PEDESTRIANS ARE ROUTED BEHIND SIDEWALK. NON SKID PLATE WILL BE USED TO MEET ADA REQUIREMENTS. SW GRADY WAY SW 12TH STLIND AVE SWROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEAD W20-5 KEEP LEFT R4-8a WORK AREA10 X 300 ONE LANE TWO WAY TAPER 50' MIN/100' MAX CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 Date:9/2/2020 Author:Kathy Hubbard, Traffic Control Supervisor Project:N.656361.C.45 CERT:TCS # 011905 Designed for CenturyLink:(DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. Designed For: CENTURYLINK Project # N.656361.C.45 Kathy Hubbard Traffic Control Supervisor TCS # 011905 Approved 9/2/2020 Phone 253-737-5198 tcpnd@comcast.net _______________________Kathy Hubbard NOT TO SCALE UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: KATHY HUBBARD, TCS# 011905, tcpnd@comcast.net N SPEEDLIMIT 35 DIG/FIX DETOUR M4-9b DETOURM4-9bwww.invarion.com MFP20000896 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.4000000000”NVICINITY MAPCUSTOMER NAME: CAR PROS RENTONLCON: BOBBY AHEARDPHONE NO: (253) 830-3028EMAIL:  bobbya@carpros.comPROJECT ID:  A.2702733ARMOR OR DSR #: 1227-1956960SCOPE OF WORK:POF: @ MANHOLE 113, SPLICE COUNT WITH LRE28, 49-50 FROM [A3HJB] ONTO [QL53] FALLING TO MANHOLE 110. @ MANHOLE110, SPLICE COUNT FROM [QL53] ONTO [GH12] FALLING TO MANHOLE 530. @ MANHOLE 530, PLACE NEW 48 COUNT FIBER INEXISTING CONDUIT TO MANHOLE 686. @ MANHOLE 686, PLACE NEW SPLICE CASE. PLACE NEW 24 COUNT FIBER IN EXISTINGCONDUIT TO CUSTOMER'S BUILDING MPOP. PLACE NEW EQUIPMENT IN CUSTOMER'S MPOP. TERMINATE LRE28, 49-50 IN FDP.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 01/02/2025N5E29N.656361W26226RNTNWA01200 SW GRADY WAYRENTON, WA 9805714MFP20000896 TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 01/02/2025N5E29N.656361W26226RNTNWA01200 SW GRADY WAYRENTON, WA 9805724MFP20000896 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 01/02/2025N5E29N.656361W26226RNTNWA01200 SW GRADY WAYRENTON, WA 9805734MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.com500 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L EOP T R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W CTL MH 110 SW 7th STREET7' SIDEWALKLIND AVE SE5' SIDEWALK DRIVEWAY TPOF CTL MH 113 DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY 5' SIDEWALK9' PLANTER9' PLANTER 7' PLANTERPLANTERSIDEWALK720333300NOTE:POF: @ MANHOLE 113,SPLICE COUNT WITH LRE28,49-50 FROM [A3HJB] ONTO[QL53] FALLING TOMANHOLE 110.NOTE:@ MANHOLE 110, SPLICECOUNT FROM [QL53] ONTO[GH12] FALLING TOMANHOLE 530.5' SIDEWALK 9' PLANTER20'11'11'17'28'45'47'37'40'MFP20000896 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.RNGE:SECT:TOWN:DRAFTED BY: MOUNTAIN LTD/SL 01/02/2025N5E29N.656361W26226RNTNWA01200 SW GRADY WAYRENTON, WA 9805744MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: STEPHEN STUARTPHONE NO: (360) 603-2701EMAIL: stephen.stuart@centurylink.com R /W R /W R/W R/W R /W R /W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R /W R/W R/W R /W R /W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W LIND AVE SESIDEWALKSIDEWALK67'60'61' EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP SW GRADY WAYSIDEWALK SIDEWALK MAPLE AVE SW SIDEWALK SIDEWALK C/L C/L C/L TCTL MH 5300'21'68'45'55'T0+00 CTL MH 68622'3'DRIVEWAY4+00 MPOPNOTE:@ CUSTOMER'S BUILDING MPOP.PLACE NEW EQUIPMENT &TERMINATE LRE28, 49-50 IN FDP.NOTE:@ MANHOLE 530, PLACE NEW48 COUNT FIBER IN EXISTINGCONDUIT TO MANHOLE 686.NOTE:@ MANHOLE 686, PLACE NEWSPLICE CASE. PLACE 400' OFNEW 24 COUNT FIBER INEXISTING CONDUIT TOCUSTOMER'S BUILDING MPOP.CAR PRO KIA200SW GRADY WAYDRIVEWAYSW 10th ST.MFP20000896 MFP20000896 MFP20000896 MFP20000896 MFP20000896 MFP20000896 MFP20000896