Loading...
HomeMy WebLinkAboutD_GillSFR_Street_Modification_210305DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE STREET MODIFICATION APPROVAL DENIAL EVALUATION FORM & DECISION PROJECT NAME: Gill SFR PROJECT NUMBER: LUA21-000051, B20-003694 PROJECT MANAGER: Nathan Janders, Civil Engineer II APPLICANT: Kevin Singh ZONING CLASSIFICATION: R8-Residential (8 DU/AC) PROJECT LOCATION: 427 Windsor Way NE SUMMARY OF REQUEST: Pursuant to RMC 4-9-250D, the applicant is requesting an Administrative Modification from RMC 4-6-060 - Street Standards to modify Windsor Way NE to maintain the existing street section. BACKGROUND: Windsor Way NE is classified as a Residential access street with an existing right-of-way width of 60 feet per the King County Assessor’s Map. The existing roadway pavement width is approximately 32 feet. The existing frontage along Windsor Way NE includes a 6 foot sidewalk, curb and gutter. Per RMC 4-6-060, Complete Street Standards, a Residential Access street requires a minimum right-of-way width of 53 feet. A minimum paved roadway width of 26 feet consisting of two 10- foot travel lanes and one 6-foot parking lane is required. A 0.5-foot curb, 8-foot planter, and 5- foot sidewalk are required along each side of the pavement. To meet the City’s Complete Street Standards and retain the existing curbline, right-of-way dedication would be required to install the 8-foot planter and 5-foot sidewalk behind the existing curb. The proposed residence is in a developed neighborhood that includes a 6-foot sidewalk that is non-conforming with current sidewalk standards. The existing roadway meets the requirement for an emergency access roadway (20-foot paved roadway width with an approved fire access turnaround). EXHIBITS: Exhibit 1: Site Plan DocuSign Envelope ID: 9567ABF6-3EB8-4F07-94FC-1258131F43CA City of Renton Department of Community and Economic Development Admin. Modification Request Report & Decision Gill SFR – STREET MODIFICATION LUA21-000051, B20003694 Report of March 4, 2021 Page 2 of 3 ANALYSIS OF REQUEST: The Section 4-6-060Q.1 allows the Administrator to grant modifications provided the modifications meet the following criteria (pursuant to RMC 4-9-250D.2): Compliance Street Modification Criteria and Analysis  a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Comprehensive Plan’s Land Use Element Goal L-B is to “Continue to build Renton’s Regional Growth Center consistent with VISION 2040 to provide compact, pedestrian- oriented, mixed-use development to meet the demands of population and employment growth, while reducing the transportation-related and environmental impacts of growth.” An overall 32-foot paved roadway width with a 6 foot sidewalk is consistent with Goal L- B reducing the transportation-related impact of growth, also consistent with Goal L-B. Compliant if condition of approval is met b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: City staff has reviewed Windsor Way NE and the surrounding area. Given that this neighborhood is already developed and that the existing roadway section provides for the code required emergency access, City Staff has determined that the existing street section meets the objectives, safety, function, appearance, environmental protection and maintainability intended by the Code requirements provided that the sidewalk meets current ADA standards. The applicant’s proposal indicates removal of the existing driveway with replacement on the east side of the parcel frontage. The sidewalk replacement and installation of the new driveway shall conform with City and ADA standards.  c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: There are no identified adverse impacts to other properties from the requested modification. See comments under criterion ‘b’.  d. Conforms to the intent and purpose of the Code. Staff Comment: See comments under criterion ‘b’.  e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: DocuSign Envelope ID: 9567ABF6-3EB8-4F07-94FC-1258131F43CA City of Renton Department of Community and Economic Development Admin. Modification Request Report & Decision Gill SFR – STREET MODIFICATION LUA21-000051, B20003694 Report of March 4, 2021 Page 3 of 3 See comments under criterion ‘b’.  f. Will not create adverse impacts to other property(ies) in the vicinity. Staff Comment: See comments under criterion ‘c’. DECISION The proposal satisfies 6 of the 6 criteria listed in RMC 4-9-250D.2 for the requested modification. Therefore, the street modifications for Gill SFR located at 427 Windsor Way NE Project Number LUA21-000051, B20003694 is Approved with the following condition. 1. If the existing sidewalk fronting the project site does not conform to ADA standards, then it shall be replaced in kind and shall conform to ADA standards. A note stating such shall be included on the site plans submit with the building permit. _______________ Brianne Bannwarth, Development Engineering Manager Date Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, March 19th, 2021. Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. If you have any further questions regarding this decision, feel free to contact the project manager, Nathan Janders, at 425.430.7382 or njanders@rentonwa.gov. DocuSign Envelope ID: 9567ABF6-3EB8-4F07-94FC-1258131F43CA 3/5/2021 | 10:08 AM PST WINDSOR WAY NEPROPOSED DRIVEWAYIMPERVIOUS MIN. TWO (2) TREES ARE TO BE LOCATED IN THE FRONT PRIOR TO FINAL INSPECTION (ORD 5676, 12-3-2012)PROPOSED DRIVEWAYAPRONGRASSSYSB5' - 0"SYSB5' - 0"R Y S B20' - 0" R E Q U IR E D 190'185'180'GARAGE EL.180.0'35.28' N 34°39'18" E127.20'12.15'120'COVERED DECKPROPOSED HOUSE FOOTPRINT 2900 SF.EL. 189'MAX. DRIVE WIDTH16' - 0"10' - 0"WALL PLATE ELEVATION24' - 0" (MAX. HT.)9' - 0"9' - 0"187'3' - 6"189'7' - 0"200'210'GARAGEMAINSECONDWINDSOR180'SLABROOFGRADEPLANEEL.183.1'EL.186.0'181' BW185' TW181' BW183' TW183' BW189' TWREQ 'D FYSB20' - 0"LINE OF DECKEXISTING 3/4-IN WATER SERVICE AND METER SHALL BEREMOVED AND CUT/CAPPED AT THE MAIN (BY CITYFORCES)FIRE SPRINKLERS REQUIREDHOMES EXCEEDING 3,600 SQUARE FEETREQUIRE A MINIMUM OF TWO FIREHYDRANTS WITHIN 300-FEET AND 2,000 GPMFIRE FLOW. EXISTING 4-INCH CITY WATERMAIN CANNOT SUPPORT TWO HYDRANTS OR2,000 GPM FIRE FLOW. AN APPROVEDRESIDENTIAL FIRE SPRINKLER SYSTEMSHALL BE INSTALLED TO LOWER FIRE FLOWREQUIREMENT AND TO SUBSTITUTE FOR THESECOND FIRE HYDRANT.182' BW186' TW185' BW189' TWEL.188.69'183' BW186' TW183' BW188' TWAVERAGE GRADE PLANEA = 188'B = 188'C = 186'D = 186'188' + 188' + 186' + 186' = 187' 4A = 188'B = 188'B = 186'B = 186'AVERAGE GRADE PLANEMAX. BUILDING HEIGHTPROPOSED SITEG. MerkelMARCH 27 -2019AVALONSheet Date:Drawn By:Scale:Client:14670 NE 8TH ST #200BELLEVUE WA 9800814208 4TH AVE SBURIEN, WA 98168As indicatedSP-1RENTON, WA 98056427 WINDSOR WAY NESIGNATURE GCISIMPLE SITE PLANPROJECT INFORMATION:ZONING DISTRICT:R-8PROPERTY OWNER:KAUR IKMAN AND GILL HARINDEPARCEL NUMBER:9476200370LOT AREA:6500 S.F.MAX. STRUCTURE HEIGHT24' PLATE ABOVE AVG. GRADESTRUCTURAL COVERAGE:MAX BUILDING COVERAGE:50 PERCENTPROPOSED STRUCTURE COVERAGE (INCL. OVERHANGS/COVERED PATIOS/PORCHES):2900 S.F. (2900/6500) = 44.6 %AREA OF DRIVEWAYS/PAVED WALKS665 S.F. (630/6500) = 9.7 %IMPERVIOUS SURFACE COVERAGE:REFER TO CIVIL CALCULATIONS -GRADING AND DRAINAGE SHEET 2FLOOR AREA SUMMARIES:HEATED FLOOR AREABASEMENT FLOOR: (UNFINISHED)1255 S.F.MAIN FLOOR:2275 S.F.UPPER FLOOR:1985 S.F.(TOTAL) HEATED LIVING AREA(S)5515 S.F.GARAGE UN-HEATED FLOOR AREA: 937 S.F.COVERED PATIO(s): 250 S.F.COVERED PORCH(s): 455 S.F.LEGAL DESCRIPTION:WINDSOR HILLS ADD TO RENTONVICINITY PLANN.T.S.SITE PLAN1" = 10'-0"Revision ScheduleRevisionNumberRevision Description RevisionDateREFER TO COR STD PLAN 104.1 THIS SHEETRMC4-4-070. ON-SITE LANDSCAPINGSHALL CONSIST OF TREES, SHRUBS, AND GROUND COVER.DocuSign Envelope ID: 9567ABF6-3EB8-4F07-94FC-1258131F43CA