HomeMy WebLinkAboutPRE_Pre-Application_Meeting_Summary_Meadow_Ave_190609_v1PRE-APPLICATION MEETING FOR
MEADOW AVE SHORT PLAT
3804 MEADOW AVE N
PRE19-000089
CITY OF RENTON
Department of Community & Economic Development
Planning Division
June 6, 2019
Contact Information:
Planner: Angelea Weihs, 425-430-7312, aweihs@rentonwa.gov
Public Works Plan Reviewers: Jonathan Chavez, 425-430-7288, jchavez@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425-430-7024, cthomas@rentonrfa.org
Building Department Reviewer: Craig Burnell, 425-430-7290, cburnell@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
FIRE & EMERGENCY
SERVICES DEPARTMENT
M E M O R A N D U M
DATE:April 30, 2019
TO:Assigned Planner
FROM:Corey Thomas, Lead Plans Review Inspector
SUBJECT:Meadow Short Plat
1. The fire flow requirement for the proposed single family homes is a minimum
of 1,000 gpm for homes under 3,600 square feet (including garage and
basement areas) and goes up to a minimum of 1,500 gpm for homes over
3,600 square feet. A minimum of one fire hydrant is required within 300-feet
of each proposed home. A minimum of two fire hydrants are required within
300-feet of the proposed homes if they exceed 3,600 square feet. It appears
existing fire hydrant can meet the minimum requirement.
2. The fire impact fees are currently applicable at the rate of $829.77 per each
individual home. This fee is paid at time of building permit issuance. Credit
is granted for the retention/removal of the one existing home.
3. Fire department apparatus access roadways are adequately served by the
existing public roads.
k:\preapps\2019\pre19-000089_ signature gci short plat\02.review comments\pre19-
000089_eng_comments_06042019.docx
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:June 6, 2019
TO:Angelea Weihs, Planner
FROM:Jonathan Chavez, Plan Reviewer
SUBJECT:Signature GCI Short Plat
3804 Meadow Avenue N
PRE19-000089
NOTE: The applicant is cautioned that information contained in this summary is preliminary and
non-binding and may be subject to modification and/or concurrence by official City decision-
makers. Review comments may also need to be revised based on site planning and other design
changes required by City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
3342700570. The following comments are based on the pre-application submittal made to the
City of Renton by the applicant.
WATER
1. Water service is provided by the City of Renton. The site is within the Kennydale 320
Pressure Zone.
2. The static water pressure is about 82 psi at ground elevation of 130 feet.
3. A pressure reducing valve is required downstream of the meter because the water
pressure exceeds 80 psi.
4. The site is located outside the City's Wellfield Capture Zones.
5. There is an existing 12-inch water main (see City water project plan no. W-0456) in
Meadow Avenue N that can deliver a maximum flow capacity of 4,500 gallons per minute
(gpm).
6. There is an existing ¾-inch domestic water meter serving the subject property that is
located along the western side of the property.
7. There is an existing fire hydrant located at the northwest corner of the N 38th Street and
Meadow Avenue N intersection (HYD-N-00179).
8. Installation of a “Storz” adapter on the existing hydrants, if they are not already equipped
with one.
9. A separate domestic water service and meter is required for each lot. Meter sizing shall
be per Uniform Plumbing Code, Chapter 6.
10. A conceptual water plan will be required as part of the land use application for the subject
development.
11. The development is subject to applicable water system development charges (SDC’s) and
meter installation fees based on the number and size of the meters for domestic uses and
Signature GCI Short Plat – PRE19-000089
June 6, 2019
Page 2 of 5
for fire sprinkler use. The development is also subject to fees for water connections, cut
and caps, and purity tests. Current fees can be found in the 2019 Development Fees
Document on the City’s website. Fees that are current will be charged at the time of
construction permit issuance.
a. The SDC fee for water is based on the size of the new domestic water to serve
the project. The current water fee for a single 1-inch meter is $4,050.00 per
meter.
b. Water service installation charges for each proposed domestic water service is
applicable. Water Service installation for a 1-inch water service line is
$2,875.00* per service line. This is payable at construction permit issuance.
c. Drop-in meter fee is $460.00* per meter for a 1-inch meter. This is payable at
issuance of the building.
d. Final determination of applicable fees will be made after the water meter size
has been determined. SDC fees are assessed and payable at construction permit
issuance.
e. A credit will be issued for any water service that is abandoned.
SEWER
1. Sewer service is provided by the City of Renton.
2. There is an existing 8-inch concrete wastewater main located in Meadow Avenue N (see
City plan no. S-017905).
3. There is an existing 6” concrete sewer stub at the west property line. There is also a 4”
side sewer from the stub to the house. The side sewer will have to be cut and capped
with the demolition of the existing house. You can re-use the existing sewer stub
provided that it is lined, if lineable.
4. The Applicant will need to install a new sewer stub for each of the new lots from the
existing sewer main in Meadow Avenue N. The new sewer stubs shall be a minimum of
6” and shall run at a slope of at least 2% to the main.
5. The development is subject to a wastewater system development charge (SDC) fee. SDC
fee for sewer is based on the size of the new domestic water to serve the project. The
current sewer fee for a 1-inch meter install is $3,100.00 per meter. A sewer system
redevelopment credit will apply for the existing sewer service.
SURFACE WATER
1. A drainage report complying with the current Renton Surface Water Design Manual
(RSWDM) will be required. Based on the City’s flow control map, the site falls within the
City’s Peak Rate Flow Control Standard (Existing Site Conditions). The site falls within the
May Creek Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of
drainage review required in the RSWM.
2. The existing site topography is relatively flat. There is no on-site stormwater conveyance
system. Stormwater from the site either infiltrates or gradually flows off-site. There is an
18” stormwater main on the west side of the property (see City plan no. D-234409).
3. If the new plus replaced pollution generating impervious surface area exceeds 5,000 SF,
the applicant will be required to provide basic water quality treatment. Any proposed
detention and/or water quality vault shall be designed in accordance with the RSWDM
that is current at the time of civil construction permit application. Separate structural
plans will be required to be submitted for review and approval under a separate building
permit for the detention and/or water quality vault.
Signature GCI Short Plat – PRE19-000089
June 6, 2019
Page 3 of 5
4. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help
mitigate the new runoff created by this development to the maximum extent feasible.
On-site BMPs shall be evaluated in order of preference by feasibility as described in
Section C.1.3 of the 2017 RSWDM. A preliminary drainage plan, including the application
of on-site BMPs, shall be included with the land use application, as applicable to the
project. The final drainage plan and drainage report must be submitted with the utility
construction permit application.
5. A geotechnical soils report for the site is required per the 2017 Renton Surface Water
Design Manual Section C.1.3. Information on the water table and soil permeability
(measured infiltration rates), with recommendations of appropriate on-site BMPs per
Core Requirement #9 and Appendix C shall be included in the report. The report should
also include information concerning the soils, geology, drainage patterns and vegetation
present shall be presented in order to evaluate the drainage, erosion control and slope
stability for site development of the proposed plat. The applicant must demonstrate the
development will not result in soil erosion and sedimentation, landslide, slippage, or
excess surface water runoff.
6. Erosion control measures to meet the City requirements shall be provided.
7. As of 9/28/2018, the City of Renton has developed a new set of Surface Water Standard
Plans to replace the existing set. These new Surface Water Standard Plans shall be used
in all future drainage plan submittals.
8. The 2019 Surface water system development fee is $0.72 per square foot of new
impervious surface, but no less than $1,800.00 for each new lot. This is payable prior to
issuance of the construction permit. This fee is subject to change based on the calendar
year the construction permit is issued.
TRANSPORTATION
1. Meadow Avenue North is classified as a residential access street with an existing right of
way width of approximately 40-41’. Per RMC 4-6-060, the minimum right of way width
for a residential access street is 53’. Per City code 4-6-060, half street improvements
shall include a pavement width of 26 feet (13 feet from centerline), a 0.5-foot curb, an
8-foot planting strip, an 5-foot sidewalk, street trees and storm drainage improvements.
a. The existing paved width is approximately 30’. The Applicant shall retain the
existing paved width and provide a 0.5-foot curb, an 8-foot planting strip, a 5-
foot sidewalk, street trees and storm drainage improvements. Dedication of
approximately 8’ (pending field survey) will be required.
2. The site borders Interstate 405 (I-405) on the east property line. Preliminary plans for
the future widening of I-405 indicate ROW acquisition from the subject site. Applicant
should further coordinate with WSDOT at 425-456-8538 for further coordination and to
verify any future impacts related to widening of the highway.
3. ADA access ramps shall be installed at all street crossings. Ramps shall be shown at each
intersection. Ramps shall be oriented to provide direct pedestrian crossings.
4. Parking lot construction shall be in accordance with City code 4-4-80G. Street lighting and
street trees are required to meet current city standards. Lighting plans are required to be
submitted with the land use application and will be reviewed during the construction
utility permit review. Shared driveways are allowed for access to up to 4 lots provided at
least one of the four (4) lots abuts a public right-of-way with at least fifty (50) linear feet
of frontage and the subject lots are not created by a subdivision of ten (10) or more lots.
Refer to the shared driveway requirements as outlined in RMC 4-6-060J. Shared
Signature GCI Short Plat – PRE19-000089
June 6, 2019
Page 4 of 5
driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of sixteen feet (16'); the Fire Department may require the tract and paved
surface to be up to twenty feet (20') wide. If a shared driveway abuts properties that are
not part of the subdivision, an eight foot (8') wide landscaped strip shall be provided
between the shared driveway and neighboring properties.
5. Refer to City code 4-4-080 regarding driveway regulations:
a. Driveways shall be designed in accordance with City standard plans 104.1 and
104.2.
b. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide
slotted drains at the lower end with positive drainage discharge to restrict runoff
from entering the garage.
c. The maximum width of a single loaded garage driveway is 9-feet and the
maximum width of a double loaded garage driveway is 16-feet. If a garage is not
present, the maximum driveway width is 16-feet.
d. Driveways shall not be closer than 5-feet to any property line.
6. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay
Requirements.
7. The transportation impact fee is based on the type of land use. For a single family
dwelling, the 2019 transportation impact fee is $7,820.42. Transportation impact fees are
subject to change based on the year the building permit is applied for.
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along
property frontage or within the site must be underground. The construction of these
franchise utilities must be inspected and approved by a City of Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft
from the right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in
accordance with code requirements:
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other
utilities is required with the exception of water lines which require 10-ft
horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or
wall or building.
c. Trench of any utility should not be in the zone of influence of the retaining wall
or of the building.
4. All civil construction permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms
page for the most up-to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
5. A landscaping plan and tree retention shall be included with the civil plan submittal. Each
plan shall be on separate sheets.
6. A demo permit is required for the demolition of the existing building. The demo permit
shall be acquired through the building department.
7. Fees quoted in this document reflect the fees applicable in the year 2019 only and will be
assessed based on the fee that is current at the time of the permit application or issuance,
as applicable to the permit type. Please visit www.rentonwa.gov for the current
Signature GCI Short Plat – PRE19-000089
June 6, 2019
Page 5 of 5
development fee schedule.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:June 6, 2019
TO:Pre-application File No. 19-000089
FROM:Angelea Weihs, Associate Planner
SUBJECT:Meadow Ave Short Plat
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other design
changes required by City staff or made by the applicant. The applicant is encouraged to review
all applicable sections of the Renton Municipal Code. The Development Regulations are
available for purchase for $50.00 plus tax from the Finance Division on the first floor of City Hall
or online at www.rentonwa.gov.
Project Proposal: The project site (Tax Parcel nos. 3342700570 and 3342700630) is comprised of
two lots located at 3804 Meadow Ave N. The project site totals approximately 35,352 square
feet in area and is zoned Residential-6 (R-6). An existing single family residence is proposed to
be demolished on parcel number 3342700570 (25,849 SF). Parcel number 342700570 (9,503 SF)
is currently vacant. Both lots currently access off of Meadow Ave N. The applicant is proposing a
lot line adjustment to the two lots in order to reduce parcel number 3342700630 to
approximately 7,000 SF and increase the lot size of parcel number 3342700570. The applicant
then proposes to build a new single family home on parcel number 3342700630, and subdivide
the larger lot (3342700570) into 3 lots for the future development of 3 single family homes.
Access to the proposed lots would be provided via residential driveways extending off of
Meadow Ave N. High erosion hazards, moderate landslide hazards, and sensitive/protected
slopes are mapped within 60 feet of the project site.
Current Use: The property is developed with an existing single family home, which is proposed
to be removed.
Lot Line Adjustment Principles of Acceptability: A lot line adjustment shall be consistent with
the following principles of acceptability:
1. Correcting: Adjust lot lines including the elimination of a common lot line in order to
correct property line or setback encroachments;
2. Improving: Create better lot design, or improve access;
3. Approval Criteria:
Meadow Ave Short Plat, PRE19-000089
Page 2 of 5
June 6, 2019
a. An additional lot, parcel or tract shall not be created; and
b. The subject lots, parcels or tracts are within the same zoning district; and
c. The proposed adjustments shall not cause the lots, parcels or tracts to
increase the nonconformity with respect to applicable zoning (see RMC 4-2),
subdivision and other code requirements pertaining to lot design, building
location, and development standards; and
d. The adjusted lot line(s) is shared by the subject lots.
4. Non-Evasive: Lot line adjustments shall not serve to eliminate or circumvent any state
or local requirements, including but not limited to frontage improvements, payment of
fee-in-lieu, payment of latecomer fees or the installation of required infrastructure.
a. Assessment of fees, right-of-way dedication and frontage improvements for
the entire length of the property line(s) bordering rights-of-way may be
required as a condition of approval for a lot line adjustment.
b. Lots, parcels or tracts that are increased in area by lot line adjustments shall
not be permitted to be subdivided for five (5) years following the date upon
which the lot line adjustment is recorded or three (3) years following the
approval of a lot line adjustment, whichever is longer, unless the following is
met:
i. The subdivision application includes all lots, parcels and tracts
involved in the lot line adjustment in the overall subdivision; or
ii. All required infrastructure, including but not limited to frontage
improvements, required infrastructure and utility lines are constructed
along the frontage of all lots included in the lot line adjustment. (Ord.
5728, 10-20-2014)
Zoning/Density Requirements: The subject property is zoned Residential-6 (R-6). The minimum
density in the R-6 zone is 3.0 dwelling units per net acre (du/ac) and the maximum density is 6.0
du/ac. Private access easements, critical areas and public right-of-way are deducted from the
total area to determine net density. For purposes of calculating net density: All fractions shall be
truncated at two numbers past the decimal. Should a calculation result in a fraction of a
dwelling unit that is 0.50 or greater, the fraction shall be rounded up to the nearest whole
number, for example, 4.56 dwelling units becomes 5.0. Should a calculation result in a fraction
that is less than 0.50, the fraction shall be rounded down to the nearest whole number, for
example, 4.49 dwelling units becomes 4.0 dwelling units. Whether the applicant chooses to do a
subdivision or combination of subdivision and Lot Line Adjustment, the proposal will arrive at a
net density of approximately 5.2 dwelling units per net acres after the deduction of
approximately 6 feet of ROW dedication along Meadow Ave N. Based on the net density of 5.2
du/ac, the subject site would meet the minimum density requirements of the zone. The
applicant would need to contact WSDOT to determine if ROW dedication is required along I-
405, which would impact density calculations. The applicant would be required to
demonstrate compliance with the net density requirements of the zone at the time of formal
application.
Meadow Ave Short Plat, PRE19-000089
Page 3 of 5
June 6, 2019
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Single Family Zoning Designations” effective at the time of complete application
(noted as “R-6 standards” herein).
Minimum Lot Size, Width and Depth – The minimum lot size permitted in Zone R-6 is 7,000
square feet for parcels less than one acre, with one lot allowed to be smaller than the required
minimum lot size. This single lot is allowed to be 6,250 square feet in Zone R-6. Minimum lot
width is 60 feet for interior lots, or 70 feet for corner lots. Minimum lot depth is 90 feet. The
applicant did not include proposed lot sizes or dimensions in the pre-application materials. The
applicant will need to demonstrate compliance with lot size, width, and depth requirements of
the zone at the time of formal land use application.
Building Standards – The R-6 standards allow a maximum building coverage of 40% of the lot
area. The maximum impervious coverage in the R-6 zone is 55%. The maximum wall plate height
is restricted to 24 feet, and the buildings shall not be more than two stories. Roofs with a pitch
equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum
wall plate height; common rooftop features, such as chimneys, may project an additional four
(4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.)
shall not extend above the maximum wall plate height unless the projection is stepped back
one-and-a-half (1.5) horizontal feet from each façade for each one (1) vertical foot above the
maximum wall plate height. Detached accessory structures are restricted to a maximum wall
plate height of 12 feet. The gross floor area must be less than that of the primary structure.
Accessory structures are also included in building lot coverage calculations. The proposal’s
compliance with the building standards for the new homes would be verified at the time of
building permit review.
Setbacks – Setbacks are the minimum required distance between the building footprint and the
property line and any private access easement or tract. The required setbacks for the R-6 zone
are: Front yard: 25 feet for the primary structure; Rear yard: 25 feet; Side yards: combined 15 ft.
with not less than 5 ft. on either side. Corner lots required to have a front yard and a secondary
front yard are relieved of the requirement to have a rear yard; in place of a rear yard setback,
the side yard setback of the zone shall apply. Lots adjacent to both public ROW and driveway
tract frontage are classified as corner lots. Setback compliance for the new homes would be
verified at the time of building permit review.
Residential Design and Open Space Standards: The Residential Design and Open Space
Standards contained in RMC 4-2-115 would be applicable to any new residential structures.
Access/Parking: Access to the proposed lots would be provided via single family residential
driveways extending off of Meadow Ave N. Each lot is required to accommodate off-street
parking for a minimum of two vehicles. Driveways exceeding 8% must provide slotted drains at
the lower end of the driveway. The maximum driveway slopes cannot exceed 15%. If the grade
exceeds 15%, a variance is required. The maximum width of single loaded garage driveways shall
not exceed 9 feet and double loaded garage driveways shall not exceed 16 feet. Compliance
with the driveway and parking regulations for the new homes would be verified at the time of
Construction and Building Permit review.
Landscaping: With the exception of critical areas, all pervious area shall have landscape
treatment. Landscaping may include hardscape such as decorative paving, rock outcroppings,
fountains, plant containers, etc. Ten feet (10') of on-site landscaping is required along all public
Meadow Ave Short Plat, PRE19-000089
Page 4 of 5
June 6, 2019
street frontages. Where there is insufficient right-of-way space or no public frontage, street
trees are required in the front yard subject to approval of the Administrator. A minimum of two
(2) trees are to be located in the front yard prior to final inspection. A conceptual landscape
plan shall be provided with the formal land use application as prepared by a registered
Landscape Architect, a certified nurseryman or other certified professional.
Significant Tree Retention: A Tree Retention/ Land Clearing (Tree Inventory) Plan along with a
tree retention worksheet shall be provided with the formal land use application. The tree
retention plan must show preservation of at least 30 percent (30 %) of significant trees, and
indicate how proposed building footprints would be sited to accommodate preservation of
significant trees that would be retained. The Administrator may authorize the planting of
replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that
an insufficient number of trees can be retained.
In addition to retaining 30 percent of existing significant trees, each new lot would be required
to provide a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected
trees that do not contribute to a lot's required minimum tree density shall be held in perpetuity
within a tree protection tract.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees
on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their
associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen
inches ( 18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; Other
significant native evergreen or deciduous trees; and Other significant non- native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods
are used as part of an approved enhancement project within a critical area or its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City's discretion.
Critical Areas: High erosion hazards, moderate landslide hazards, and sensitive/protected
slopes are mapped within 60 feet of the project site. Whenever a proposed development
requires a development permit and a geologic hazard, including sensitive slopes, is present on
the site of the proposed development or on abutting or adjacent sites within fifty feet (50') of
the subject site, geotechnical studies by licensed professionals, such as a geotechnical engineer
and/or engineering geologist, shall be required. It is the applicant’s responsibility to ascertain
whether critical areas or environmental concerns are present on the site during site
development or building construction.
Environmental Review: The proposed project is categorically exempt from Environmental
(SEPA) Review.
Permit Requirements: The proposal would require administrative short plat approval. The
application would be reviewed within an estimated time frame of six to eight weeks. The 2019
administrative short plat application fee is $5,397.00 ($5,140.00 each plus a 5% Technology
Surcharge Fee). Each modification request is $262.50 ($250.00 each plus a 5% Technology
Meadow Ave Short Plat, PRE19-000089
Page 5 of 5
June 6, 2019
Surcharge Fee). All fees are subject to change. Detailed information regarding the land use
application submittal can be found on the City’s new website by clicking “Land Use Applications”
on the Community & Economic Development page, then “All Forms (A to Z).” The City now
requires electronic plan submittal for all applications.
Once Preliminary Short Plat approval is obtained, the applicant must complete the required
improvements and dedications, as well as satisfy any conditions of the preliminary approval
before submitting for Final Short Plat review. Once final approval is received, the plat may be
recorded. The newly created lots may only be sold after the plat has been recorded. In addition
to the required land use permits, separate construction and building permits would be required.
Public Notice: A minimum of one Public Information Sign is required for a Short Plat application.
The applicant is responsible for the procurement, installation and maintenance of the sign.
Detailed information regarding the land use application submittal requirements is provided on
the City of Renton website (www.rentonwa.gov).
Fees: In addition to the applicable building and construction fees, impact fees would be
required. Such fees would apply to all projects and would be calculated at the time of building
permit application and payable prior to building permit issuance. The 2019 impact fees are as
follows:
A Transportation Impact Fee based on $7,820.42 per each new detached dwelling unit.
A Parks Impact Fee based on $2,740.07 per each new detached dwelling unit.
A Fire Impact fee of $829.77 per each new detached dwelling unit.
Renton School District Impact Fee is $6,877.00 per each new detached dwelling unit.
A handout listing Renton’s development-related fees is available on the City of Renton website
for your review.
Note: When the formal application materials are complete, the applicant is strongly
encouraged to have one copy of the application materials pre-screened at the 6th floor front
counter prior to submitting the complete application package. Please call Angelea Weihs,
Associate Planner at aweihs@rentonwa.gov or 425-430-7312 for an appointment.
Expiration: Upon approval, the Short Plat is valid for five years with a possible one year