HomeMy WebLinkAboutCD-4142RAYMOND AVENUE SW
SW 16TH STREETEastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RPROJECT TEAM:COVER SHEET1 of 8TOPOGRAPHIC SURVEY2 of 8TESC PLAN & NOTES3 of 8TESC DETAILS 4 of 8GRADING & UTILITY PLAN 5 of 8CONSTRUCTION NOTES6 of 8CONSTRUCTION DETAILS7 of 8CONSTRUCTION DETAILS8 of 8LANDSCAPE PLANL1.0LANDSCAPE SCHEDULE, NOTES & DETAILSL1.1IRRIGATION PLANIR1.0IRRIGATION SCHEDULE, NOTES & DETAILSIR1.1TITLESHEET INDEX:SHEETVICINITY MAPNORTH
SITE INFORMATION:BUILDING SETBACKS:NW 1/4 OF SW 1/4 OF SEC. 19, TWP. 23 N., RNG. 5 E., W.MCITY OF RENTON, STATE OF WASHINGTONMADRONA ELECTRICUTILITY DISTRICT INFORMATION:CONTRACTOR RESPONSIBILITY:DISCREPANCIES:EXISTING UTILITY NOTE:LEGAL DESCRIPTION:VERTICAL DATUM:BENCHMARK:HORIZONTAL DATUM:BASIS OF BEARINGS:DEVELOPMENT ENGINEERINGNathan Janders 01/27/2021APPROVED01/28/2021 jdingPLANNING DIVISIONREGIONAL FIRE AUTHORITYcthomas 01/28/2021APPROVEDSURFACE WATER UTILITYjfarah 01/28/2021WASTEWATER UTILITYAnn Fowler 02/01/2021WATER UTILITYagafour 02/04/2021
RAYMOND AVENUE SW
SW 16TH STREETLIND AVENUE SWEastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RNORTH
RAYMOND AVENUE SW
SW 16TH STREETEastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RNORTHCONSTRUCTION SEQUENCE:APPROXIMATE CUT/FILL VOLUMESDISTURBANCE AREADEVELOPMENT ENGINEERINGNathan Janders 01/27/2021
Eastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RDEVELOPMENT ENGINEERINGNathan Janders 01/27/2021
RAYMOND AVENUE SW
SW 16TH STREETEastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RNORTHNOTES:ONSITE PAVING SECTIONKEY NOTES:DEVELOPMENT ENGINEERINGNathan Janders 01/27/2021SURFACE WATER UTILITYjfarah 01/28/2021WASTEWATER UTILITYAnn Fowler 02/01/2021WATER UTILITYagafour 02/04/2021
Eastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RWATER UTILITY STANDARD PLAN NOTES:DEVELOPMENT ENGINEERINGNathan Janders 01/27/2021
Eastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RDEVELOPMENT ENGINEERINGNathan Janders 01/27/2021
Eastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSKnow what'sCallbelow.before you dig.RDEVELOPMENT ENGINEERINGNathan Janders 01/27/2021WASTEWATER UTILITYAnn Fowler 02/01/20211-INCH WATER SERVICE LINE AND 1-INCH METER(S) FOR DOMESTIC AND FOR LANDSCAPEIRRIGATION TO BE INSTALLED BY CITY OF RENTON - WATER METER PERMITS ARE REQUIREDWATER UTILITYagafour 02/04/2021
MBBFPVP.O.C, 1" irrigation meter with approvedbackflow preventor. All landscape areas willbe watered with an underground automaticirrigation systemAFS1R Rain sensorControllerFlow sensorProvide sleeving, 2x's thepipe dia.SW 16th StreetRaymond Ave SWBall valve43Control ValveMadrona Electric OfficeBuilding21VVAir Relief ValveDripline ZoneLateral lineProvide water to natural areafor the first 2 growing seasons,then zone can be shut offProvide water to natural areafor the first 2 growing seasons,then zone can be shut offMain lineIN COMPLIANCE WITH CITY OF RENTON STANDARDSR-414232R-414232
MADRONA ELECTRICIRRIGATION PLANMADRONA ELECTRICIR1.0ARW Landscape DesignAmy R. Wolfe, PLA253.223.1162e: amy@arwlandscapedesign.comwww.arwlandscapedesign.comSTATEOFWASHINGTONAMYRUSHOWOLFENO1551EXP04\01\2022 LICENSEDLANDSCAPEARCHITECT
N0Scale: 1" = 10'1"12"010'5'DEVELOPMENT ENGINEERINGNathan Janders 01/27/2021APPROVED01/28/2021 jdingPLANNING DIVISION
This "natural area" to be plantedwith native conifers and trees,and a native meadow mixMadrona Electric OfficeBuildingNew parking lotProperty line12" CAST IRON WASW 16th StreetRaymond Ave SW
Parrotia persica /Persian ParrotiaQuercus robur x alba 'Crimschmidt' /Crimson Spire Oak10'11.5'Property lineAcer circinatum /Vine MaplePinus contorta /Shore PinePseudotsuga menziesii /Douglas FirCistus x lenis 'Grayswood Pink' /Pink RockroseLavandula angustifolia 'Hidcote' /English LavenderMahonia nervosa /Longleaf MahoniaVerbena lilacina 'De La Mina' /De La Mina VerbenaFestuca glauca 'Boulder Blue' /Boulder Blue FescueArctostaphylos uva-ursi /Kinnikinnick18" SEWER LINEEx. sidewalkEx. sidewalk
GENERAL NOTES:1.All plans are drawn to scale. Location of lawn edges, trees,shrubs, and groundcover are shown approximately.2.Call 1-800-424-5555 or 811 before you dig to locateunderground utility lines.3.See sheet L1.1 for plant schedule and details.IN COMPLIANCE WITH CITY OF RENTON STANDARDSR-414232R-414232
MADRONA ELECTRICLANDSCAPE PLANMADRONA ELECTRICL1.0ARW Landscape DesignAmy R. Wolfe, PLA253.223.1162e: amy@arwlandscapedesign.comwww.arwlandscapedesign.comSTATEOFWASHINGTONAMYRUSHOWOLFENO1551EXP04\01\2022 LICENSEDLANDSCAPEARCHITECT
N0Scale: 1" = 10'012"1"5'10'APPROVED01/28/2021 jdingPLANNING DIVISION
PLANT SCHEDULEBotanical Name/Common NameQty.SizeSpacingNotesTreesAcer circinatum 26-7' ht.25' o.c.B&B, nursery grown, deciduous,(Vine Maple)native, multi-trunk, evenly branchedPinus contorta16-7' ht.25' o.c.B&B, nursery grown, evergreen,(Shore Pine)native, full foliage, do not top or trimPseudotsuga menziesii26-7' ht.25' o.c.B&B, nursery grown, evergreen,(Douglas Fir)native, do not top or trim, full foliageParrotia persica42" cal.30' o.c.B&B, nursery grown, street tree(Persian Ironwood)quality, branched @ 5' heightQuercus robur x alba 'Crimschmidt'32" cal.30' o.c.B&B, nursery grown, street tree(Crimson Spire Oak)quality, branched @ 5' heightShrubsCistus x lenis 'Grayswood Pink'122 gal.5' o.c.Nursery grown, pink flowers,(Grayswood Pink Rockrose)no trimming neededEscallonia 'Newport Dwarf'32 gal.4' o.c.Nursery grown, dark pink flowers,(Newport Dwarf Escallonia)no trimming neededLavandula angustifolia 'Hidcote'282 gal.2.5' o.c.Nursery grown, fragrant flowers,(Hidcote English Lavender)trim flowers in fallMahonia nervosa142 gal.3' o.c.Nursery grown, native,(Longleaf Mahonia)no trimming neededPerennials, Ferns and GrassesFestuca glauca 'Boulder Blue'141 gal.1.5' o.c.Nursery grown, bluish-green,(Boulder Blue Fescue)no trimming neededVerbena lilacina 'De La Mina'41 gal.2' o.c.Nursery grown, evergreen,(De La Mina Verbena)trim only as neededGroundcoverArctostaphylos uva-ursi591 gal.2' o.c.Nursery grown, evergreen,(Kinnikinnick)native groundcoverPT 454 Native Urban Meadow6500 sf.2 Lbs.4 oz. / 1000sf.50% grasses, 40% perennials, 10% annuals, mowMix / PTlawnseed.comonce at the end of summer, no lower than 4"Total Number of Plants = 146Total Number of Native Plants = 78MATERIALS SCHEDULEDescription / ManufacturerUnitsNotesItem3-Way Topsoil Mix for Natural Area60 Cy.Mix 3" layer into landscapebed to a depth of 6"3-Way Topsoil Mix for Planting Beds25 Cy.Mix 4" layer into new landscapebeds to a depth of 8"Dark Brown Medium Bark Mulch52 Cy.Spread evenly around plantsor Wood Chipsto a depth of 2"GENERAL LANDSCAPE NOTES:SITE PREPARATION:1. Landscape areas shall be free of weeds, rocks, tree stumps and limbs, construction debris,slurry, and other construction materials prior to soil preparation of planting bed areas.2. Contractor to dispose of all construction debris legally off site, and stockpile topsoil on site foruse in landscape beds.3. All new planting beds shall be de-compacted by roto-tilling, disking or ripping to a minimumdepth of 8" and will be amended with 3-way mix topsoil.4. Contractor to evaluate soil conditions (pH level, nutrient content, etc..) and correct as needed,in addition to applying 3-way mix topsoil composed of 60% peat, 35% sandy loam, and 5% agedsawdust, or equal.PLANT SPECIFICATIONS:1. Finished grade of all planting areas to be approximately 1" below curb or sidewalk.2. Landscape architect (designer) to be notified of any plant substitutions prior to delivery, andapproved by owner or designer. Plant material shall be delivered to the site free of diseases, pests,and damaged or broken branches, trunks or limbs.3. All plants shall conform to the Z60.1 "American Standard for Nursery Stock" manual as publishedby the American Association of Nurseryman (AAN).4. Contractor to guarantee all plants for 1 year and replace any dead or dying plants as notified bythe owner.5. Any damaged plant material delivered on site shall be returned and replaced by the grower orcontractor.6. No shrubs or trees, from the center of the plant, shall be planted within 3' of paving, and noperennials, ferns, or groundcover shall be planted within 1' of paving.7. All deciduous and coniferous trees shall be placed and installed first, followed by all shrubs,perennials, ferns, ornamental grasses, and groundcover.8. Apply organic fertilizer to all newly installed lawn areas and planting beds, per manufacturer'sspecifications.9. All proposed plants should be allowed to grow naturally. Trimming is not needed, except forthe occasional removal of broken, dead, damaged branches, or to maintain clearance oversidewalks. Remove leaves with a leaf blower or by raking, and remove any broken branches, orlimbs in the fall.MAINTENANCE:1. After installation, all plants shall be maintained monthly during the growing season or as neededto remove any weeds or invasive vegetation.2. Check shrubs and trees monthly to trim off any broken or damaged limbs or branches.3. Replenish wood chip or bark mulch to maintain at least a 2" minimum depth.4. Provide sufficient irrigation as needed, especially in the summer months.Dark brown bark mulchor arborist wood chips,2" depth min.Amend soil with 1/2native soil and 1/23-way mix topsoilExisting native soilCreate soil saucer atedges of watering basinPlanting pit to be roughly twicethe width of the root ballTop of root ball to be evenwith surrounding finishedgrade. Trunk flare should bejust above finish grade.Coniferous Tree Planting DetailNTSDark brown bark mulchor arborist wood chips,2" depth min.Amend soil with 1/2native soil and 1/23-way mix topsoilExisting native soilCreate soil saucer atedges of watering basinPlanting pit to be roughly twicethe width of the root ballTop of root ball to be even withsurrounding finished grade.Trunk flare should be justabove finished grade.Deciduous Tree Planting DetailNTSFold down or remove a 1/3of the burlap covering orremove non-biodegradablematerial entirelyFold down or remove a 1/3of the burlap covering orremove non-biodegradablematerial entirelyDark brown bark mulchand arborist woodchips, 2" depth min.Amend soil with 1/2native soil and 1/23-way mix topsoilExisting native soilCreate soil saucer atedges of watering basinPlanting pit to be twicethe width of the root ballTop of root ball to beeven with surroundingfinished gradeShrub/Ground Cover Planting DetailNTSRemove plastic containerand loosen soil and rootsof rootball with fingers orspadeGround Cover Triangular Spacing DetailNTSEqual spacingbetween plantsTriangularspacingMin. 1/3 of tree height2"Ø x 8' length LodgepolePine tree stakes, (removeafter 2 years)1'Plastic lock - tie or rubberhose tree tie, set loose toallow for diameter growth1' Min.Street treesbranched@ 5' ht.Drive stake atrootball edge6"-12" depth"Chainlock" or equal tree tie material(1" size) nail or staple tree tie materialto stake to hold vertically. Loop eachtie around half tree loosely to provide1" slack for trunk growth.Stake tree with (2) treated 2"ØLodgepole Pine doweled tree stakes (8'length). Loop each tie around half treeloosely to provide 1" slack for trunkgrowth. Remove stakes after 2 years.18-24" depth rootbarrier at pavingedge for street trees18-24" depth root barrierat paving edge for treeswithin 10' of the edgeConifers to be 10' min.from paved edges, unlessotherwise approved byLandscape ArchitectNotes:1)Contractor to ensure roots are not kinked, circling, or girdling the trunk,prior to installation, see Root Ball Condition Detail.2)If roots are found to be defective, contractor to correct per the RootCorrection Detail, or replace plant material prior to installation.Street trees to be 3' min. from paved edges, unlessotherwise approved by Landscape Architect.Notes:1)Contractor to ensure roots are not kinked, circling, or girdling the trunk,prior to installation, see Root Ball Condition Detail.2)If roots are found to be defective, contractor to correct per the RootCorrection Detail, or replace plant material prior to installation.If planting width is too narrowfor triangular spacing then uselinear spacingFor shrubs with mature heightsover 3', plant 3' min. away frompaving to center of plant. Forshrubs with a mature height under3', plant 2' min. away from pavededges.Notes:1)Contractor to ensure roots are not kinked, circling, or girdling the trunk,prior to installation, see Root Ball Condition Detail.2)If roots are found to be defective, contractor to correct per the RootCorrection Detail, or replace plant material prior to installation.Keep center of plants6-12" from paved edgesACCEPTABLEREJECTABLERRRWFROODURRRWVUDGLDWHIURPWUXQNDQGUHDFKVLGHRIURRWEDOOZLWKRXWGHIHFWLQJGRZQRUDURXQGRRRWEDOOSHULSKHU\AEVRUELQJURRWV6WUXFWXUDOURRWV6WUXFWXUDOURRWV6WUXFWXUDOURRWVSULPDULO\JURZWRRQHVLGH6WUXFWXUDOURRWVPLVVLQJIURPRQHVLGHDQGRUJURZWDQJHQWWRWUXQN6WUXFWXUDOURRWVFLUFOHLQWHULRURIURRWEDOO1RVWUXFWXUDOURRWVDUHKRUL]RQWDODQGUHDFKWKHURRWEDOOSHULSKHU\QHDUWKHWRSRIWKHURRWEDOO6WUXFWXUDOURRWVGHVFHQGLQWRURRWEDOOLQWHULRU1RVWUXFWXUDOURRWVDUHKRUL]RQWDODQGUHDFKWKHURRWEDOOSHULSKHU\QHDUWKHWRSRIWKHURRWEDOO2QO\DEVRUELQJURRWVUHDFKWKHSHULSKHU\QHDUWKHWRSRIWKHURRWEDOO6WUXFWXUDOURRWVPRVWO\ZUDSRUDUHGHIOHFWHGRQWKHURRWEDOOLQWHULRU1RWHV2EVHUYDWLRQVRIURRWVVKDOORFFXUSULRUWRDFFHSWDQFHRRRWVDQGVRLOPD\EHUHPRYHGGXULQJWKHREVHUYDWLRQSURFHVVVXEVWUDWHVRLOVKDOOEHUHSODFHGDIWHUWKHREVHUYDWLRQVKDYHEHHQFRPSOHWHG6HHVSHFLILFDWLRQVIRUREVHUYDWLRQSURFHVVDQGUHTXLUHPHQWV6WUXFWXUDOURRWFLUFOLQJ0-112"TRSRIURRWEDOOPRLQWZKHUHWRSPRVWURRWHPHUJHVIURPWUXQNTKHSRLQWZKHUHWRSPRVWURRWVHPHUJHVIURPWKHWUXQNURRWFROODUVKRXOGEHZLWKLQWKHWRSRIVXEVWUDWHTKHURRWFROODUDQGWKHURRWEDOOLQWHULRUVKRXOGEHIUHHRIGHIHFWVLQFOXGLQJFLUFOLQJNLQNHGDVFHQGLQJDQGVWHPJLUGOLQJURRWV6WUXFWXUDOURRWVVKDOOUHDFKWKHSHULSKHU\QHDUWKHWRSRIWKHURRWEDOOAEVRUELQJURRWV6WUXFWXUDOURRWVFLUFOHDQGGRQRWUDGLDWHIURPWKHWUXQN6WUXFWXUDOURRWJURZLQJWDQJHQWSDUDOOHOWRWUXQNCXWKHUHCXWKHUHCXWKHUHCXWKHUHTUHHSODQWHGWRRGHHSO\LQURRWEDOORHPRYHH[FHVVVRLODQGURRWVWRPHHWURRWLQVSHFWLRQGHWDLORHPRYHVWUXFWXUDOURRWVVKRZQLQEODFNH[WHQGLQJIURPURRWEDOO)RXUVWUXFWXUDOURRWVVKRZQLQEODFNRHPRYHURRWZKLWHJURZLQJRYHUVWUXFWXUDOURRWV)LYHVWUXFWXUDOODUJHURRWVVKRZQLQEODFNRHPRYHVWUXFWXUDOZKLWHURRWZUDSSLQJURRWFROODU6L[VWUXFWXUDOURRWVVKRZQLQEODFNRHPRYHVWUXFWXUDOURRWVZKLWHJURZLQJRYHUURRWFROODUE\FXWWLQJWKHPMXVWEHIRUHWKH\PDNHDQDEUXSWWXUQCXWKHUHCXWKHUH1RWHVAOOWUHHVVKRZQDUHUHMHFWDEOHXQOHVVWKH\XQGHUJRUHFRPPHQGHGFRUUHFWLRQ)LUVWVWHSWKHQVWHSAGMXVWKROHGHSWKWRDOORZIRUWKHUHPRYDORIH[FHVVVRLODQGURRWVRYHUWKHURRWFROODURRRWVDQGVRLOPD\EHUHPRYHGGXULQJWKHFRUUHFWLRQSURFHVVVXEVWUDWHVRLOVKDOOEHUHSODFHGDIWHUWKHFRUUHFWLRQKDVEHHQFRPSOHWHGTUHHVVKDOOSDVVURRWREVHUYDWLRQVGHWDLOIROORZLQJFRUUHFWLRQ1HZURRWEDOOVXUIDFHTUHHSODQWHGWRRGHHSO\LQURRWEDOORHPRYHH[FHVVVRLODQGURRWVWRPHHWURRWLQVSHFWLRQGHWDLORHPRYHH[FHVVURRWVRHPRYHH[FHVVVRLO6HYHQVWUXFWXUDOURRWVVKRZQLQEODFNRHPRYHVWUXFWXUDOURRWVZKLWHJURZLQJDURXQGRURYHUURRWFROODUE\FXWWLQJWKHPMXVWEHIRUHWKH\PDNHDQDEUXSWWXUQ6WHSRHPRYHVRLODQGURRWVRYHUWKHURRWFROODU6WHSRHPRYHGHIHFWVRRRWFROODURRRWFROODURHPRYHVWUXFWXUDOURRWVVKRZQLQEODFNGHIOHFWHGRQURRWEDOOSHULSKHU\6PDOOURRWVRUOHVVDWWKHSHULSKHU\RIWKHURRWEDOODUHQRWGHILQHGDVGHIHFWVDQGGRQRWQHHGWREHUHPRYHGRoot Correction Detail for Balled &Burlapped Trees or ShrubsNTSRoot Ball Condition for Balled &Burlapped Trees or ShrubsNTS,1C20PL,A1CE:,T+C,T<2)RE1T216TA1'AR'6R-414232R-414232
MADRONA ELECTRICLANDSCAPE SCHEDULE, NOTES & DETAILSMADRONA ELECTRICL1.1ARW Landscape DesignAmy R. Wolfe, PLA253.223.1162e: amy@arwlandscapedesign.comwww.arwlandscapedesign.com6TATE2):A6+,1*T21A0<R86+2:2L)E12E;P??L,CE16E'LA1'6CAPEARC+,TECT
APPROVED01/28/2021 jdingPLANNING DIVISION
BRASS GATE VALVEMANUFACTURER/DESCRIPTIONSYMBOLMODELCOMMENTSIRRIGATION LEGEND1 " IRRIGATION METER (BY OTHERS COORDINATEP.O.C. WITH CONSTRUCTION MANAGER)60 PSISTATIC PRESSUREHUNTER1" FLOW SENSORHFS W/ FCT-150WIRE DIRECTLY TOCONTROLLERHUNTER CONTROLLERWALL MOUNTED METALCABINETFS1BFPV1" BACK FLOW PREVENTORMLIMITS OF HUNTERIN-LINE DRIPHDL-09-24-250-PC24" ROW SPACING.9030DRIPMANUFACTURER/DESCRIPTIONSYMBOLMODELGPHPSIHUNTER DRIP CONTROLZONE KITICZ-101-2530PIPEMANUFACTURER/DESCRIPTIONSYMBOLMODELCOMMENTSPIPE AND WIRE SLEEVINGSCH 40 PVCSCH 40 PVCDIAMETER TO BE TWICETHE SIZE OF THE PIPEBEING SLEEVEDIRRIGATION MAIN LINE 1 1/2"FEBCO 850RUB BALL VALVE, S95F43 (ROUNDHANDLE)BSIZE TO MATCH METERSIZE TO FIT MAINLINEARHUNTER RAIN SENSORRAIN-CLIK-SGMWIRELESS RAIN SENSORW/GUTTER MOUNTIC-600-MVHUNTER AIR RELIEF VALVEPLD-ARV30xCONTROLLER A VALVE KEYVALVESIZEGPM11"2.5021"4.2531"12.6041"12.60TYPEDRIP / SHRUBDRIP / SHRUBSPRAY HEADSSPRAY HEADS12'HUNTER - POP-UPSPRAY HEAD30SPRAY HEADSMANUFACTURER/DESCRIPTIONSYMBOLRAD.MODELPSIPRO ADJUSTABLE NOZZLES PIPE SIZING LEGEND3/4" SCH 40 PVC1" SCH 40 PVC1-1/4" SCH 40 PVC(0-8 GPM)(8-12 GPM)(12-22 GPM)1-1/2" SCH 40 PVC(22-30 GPM)2" SCH 40 PVC(30-50 GPM)5'HUNTER - POP-UPSPRAY HEAD30PRO ADJUSTABLE NOZZLES 10'HUNTER - POP-UPSPRAY HEAD30PRO ADJUSTABLE NOZZLES HUNTER 1" AUTOMATIC CONTROL VALVEICV-151G-FSWIRE DIRECTLY TOCONTROLLER, SEE VALVE KEYWITH PRESSURE REGULATORX27'HUNTER / MP ROTATORMP300030ADJUSTABLE ARC & FULL CIRCLENTSICZ DRIP CONTROL ZONE KITMETAL CONTROLLER DETAILNTSNTSICV GLOBE VALVEFDRIPLINE LAYOUT DETAILNTSVIRRIGATION NOTES:1.Design assumes static water pressure at the source to be 45 PSI.Notify designer if PSI is below 45 PSI.2.All irrigation laterals, driplines, valves, and mainlines are showndiagrammatically, align in planting beds next to paved areas.3.Install driplines, and lateral lines in shortest, straight run aspossible.4.Group valves together in boxes convenient to zones.5.Rain sensor to be mounted on a west or south facing wall or gutter.6.Controller location shown is approximate, mount controller withineasy access of electrical connections.7.Contractor to provide sleeving (two times the pipe dia.) under allpaved areas for irrigation piping.8.Contractor to verify irrigation P.O.C., and at least 45 PSI at thesource, and install city approved backflow prevention device.9.Contractor to verify irrigation system is functioning properly and willprovide full coverage for all planting areas. Water plantsimmediately after installation daily in the warm spring and summermonths, and as needed in the fall and winter months.10.All plants shall be watered for the first two seasons to help roots getestablished. After two seasons, irrigation shall be applied as neededmostly in the dry spring and summer months.IN COMPLIANCE WITH CITY OF RENTON STANDARDSR-414232R-414232
MADRONA ELECTRICIRRIGATION SCHEDULE, NOTES & DETAILSMADRONA ELECTRICIR1.1ARW Landscape DesignAmy R. Wolfe, PLA253.223.1162e: amy@arwlandscapedesign.comwww.arwlandscapedesign.comSTATEOFWASHINGTONAMYRUSHOWOLFENO1551EXP04\01\2022 LICENSEDLANDSCAPEARCHITECT
APPROVED01/28/2021 jdingPLANNING DIVISION