Loading...
HomeMy WebLinkAboutEx_04_Plan Drawings.pdf1 2 3 4 5 6 7 8 9 10 11 12 13 _______ OGPA2.1 2 NEW SIGN -REF 4 OGPA2.1 20'-0" EQEQ 14'-11"P76U P134E ETR CAP EXISTING SIGNAGE AND PAINT TO REMAIN UNO 13.1 13.5 A B C D E F G HF.6 _______ OGPA2.1 1 EXISTING SIGNAGE AND PAINT TO REMAIN UNO REMOVE EXISTING SIGN E.6 12345678910111213 _______ OGPA2.1 3 EXISTING SIGNAGE AND PAINT TO REMAIN UNO 13.113.5 ABCDEFGHF.6 EXISTING SIGNAGE AND PAINT TO REMAIN UNO E.6 DEMOLITION NOTES 1. 2. 3. REMOVAL OF LIT ID/LOGO SIGNS AND UNLIT EXTERIOR STUD MOUNTED BUILDING SIGNS BY OTHERS. GENERAL CONTRACTOR TO PATCH/REPAIR HOLES LEFT AFTER SIGNS ARE REMOVED AND REPAINT AS REQUIRED. REMOVAL OF BUILDING MOUNTED ITEMS, SHOWN OR NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE OF WORK, SHALL OCCUR PRIOR TO PAINTING BUILDING OR RE-WRAP OF TRESPA PANELS. architecture 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 +engineering Architect of Record William Douglas Hurley Washington License No. 8855 Unified Business ID No. 602 491 668 STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY: CHECKED BY: DOCUMENT DATE: PROTO: PROTO CYCLE: DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION SHEET: ISSUE BLOCK C:\Users\jontannehill\Documents\02516_Renton_WA_150_R_ARCH_V20_OGP_jdt3698.rvtRENTON, WASHINGTON10.09.2020RENTON, WASHINGTONSTORE NO.2516-249JOB NUMBER: 2019.0203JT SBD 150 08.28.2020 10.09.2020 OVERALL EXTERIOR ELEVATIONS OGPA2 1" = 20'-0"1 FRONT (EAST) ELEVATION 1" = 20'-0"2 RIGHT (NORTH) ELEVATION 1" = 20'-0"3 REAR (WEST) ELEVATION 1" = 20'-0"4 LEFT (SOUTH) ELEVATION COLOR LEGEND P76U WALMART BLUE (URETHANE-LIKE) P134E LIGHT GRAY 3 12.18.2020 CCD#3 5 03.25.2021 CCD #5 5 5 EFF.6M1M1P134EP134EP135E4'-0"TYPCAP121' - 4"TOM116' - 8"TOMCARD READER.REF ELECTRICALDOOR HOOD.-REF5OGPA8P134ETYP4.084.084.084.04TYP-REF5OGPA3AND STRUCTURALE.64.09P134EP135E4.08TYP4.081OGPA33OGPA32OGPA3_______OGPA2.110VERIFY ROOF HEIGHT WITH STRUCT18'-2"13121' - 4"116' - 8"TOMTOM4'-0"P134EP134EP135EM1P134E4.084.084.084.04TYP-REF5OGPA3AND STRUCTURAL13.113.54.09TYPTYP4.08P135E3OGPA32OGPA3CAPP134E1OGPA3SEISMIC EXPANSION JOINT-REF6OGPA3136OGPA2.1121' - 4"TOMVERIFY THAT NEW ADDITIONMATCHES EXISTING BUILDING HEIGHTP134EP134ECAP4.094.04TYP-REF5OGPA3AND STRUCTURAL13.113.51OGPA3SEISMIC EXPANSION JOINT-REF6OGPA37OGPA2.1100'-0"FF ELJBEREF STRUCTALUMINUM FLOOR BRACKET BY LADDER MANUFACTURER. ANCHOR INTO CONCRETE1/2"Ø THRU-WALL ANCHORS W/ WASHER & 2"x2"x1/4" STEEL BACKING PLATES, TYP.1.2.3.4.5.6.NOTES:ALL WALL ANCHORS SHALL BE ZINC ALLOY. PROVIDE NEOPRENE SPACERS BETWEEN DISSIMILAR METALS.PAINT LADDER TO MATCH ADJACENT FINISHES.INSTALL JOINT SEALANT OVER 1/2" EXP JOINT FILLER AT ALL EXTERIOR WALL/PAVEMENT JOINTS AND AT ALL CUTS AND HOLES THROUGH PAVEMENT.GATE HARDWARE PER MANUFACTURER.FIELD VERIFY ALL DIMENSIONSGENERAL CONTRACTOR TO FURNISH AND INSTALL A LOCK BOX AT EACH LADDER LOCATION (2). COORDINATE TYPE OF BOX AND LOCATION WITH FIRE DEPARTMENT OFFICIAL. REF TO SPECS1/2"Ø THRU-WALL ANCHORS W/ WASHER & 2"x2"x1/4" STEEL BACKING PLATES, TYP.121'-4"TOM2' - 5"3' - 8"2' - 0"4' - 0"4' - 0"4' - 0"7' - 5" OF PLATFORM21'-8" TOPGATE HEIGHT7' - 1"1"+/- 8"TYP1' - 0"45.00°MIN6" 7"6OGPA2.11' - 8"1' - 8"SECURITY DOOR W/ PIANO HINGE AND HASP LOCK BY LADDER MANUFACTURERALUMINUM EXPANDED METAL1"x1"x3/16" ALUMINUM ANGLE FRAME VERTICAL LEG TURNED UP. WELDED TO TOP OF SECURITY DOORFIELD ASSEMBLED EXTERIOR METAL LADDER. FASTEN TO WALL PER MANUFACTURER'S INSTRUCTIONS W/ 1/2"Ø THRU WALL ANCHORS W/ WASHERS AND 2"X2"X1/4" ALUMINUM BACKING PLATESEXTERIOR WALL2'-0"2'-3 1/2"EXISTING SIGNAGE SCHEDULETOTAL AREAQTY COLORINDIVIDUALAREAGroceryHome & PharmacyOutdoorWalmartTOTAL FRONT SIGNAGESF SF1WHITEWHITEWHITESIGNAGE LOCATIONFRONT SIGNAGESIZE* (Spark)LIGHTEDLEDLEDN/AYELLOW3'-0"12'-0"2'-6"2'-6"2'-6"31.88 31.8811N/AN/AWHITE SF SF41.05 41.05SF SF94.90 94.90342.89 SFSF342.89TOTAL BUILDING SIGNAGE1SF SF128.22 128.221SF SF46.84 46.84PROPOSED SIGNAGE SCHEDULETOTAL AREAQTY COLORINDIVIDUALAREAGrocery (ETR)Home & Pharmacy (ETR)Outdoor (ETR)Walmart (ETR)TOTAL FRONT SIGNAGESF SF1WHITEWHITEWHITESIGNAGE LOCATIONFRONT SIGNAGESIZE* (Spark)(ETR)LIGHTEDLEDLEDN/AYELLOW3'-0"12'-0"2'-6"2'-6"2'-6"31.88 31.8811N/AN/AWHITE SF SF41.05 41.05SF SF94.90 94.90393.91 SFSF393.91TOTAL BUILDING SIGNAGE1SF SF128.22 128.221SF SF46.84 46.84Pickup LED WHITE2'-6"1SF SF32.84 32.84* (Spark) LED YELLOW4'-5 7/16"1SF SF18.18 18.18SIGNAGE GENERAL NOTES1.2.A.B.C.3.A.B.C.4.A.B.C.D.SIGNAGE FURNISHED BY WAL-MART AND INSTALLED BY OTHERS.ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN IN PLACE ON THE BUILDING UNTIL THE EXTERIOR SIGN COMPANY IS ONSITE. THE EXTERIOR SIGN COMPANY WILL REMOVE ALL EXISTING SIGNAGE WITH THE EXCEPTION OF TENANT SIGNAGE AND INSTALL NEW SIGNAGE. ONCE NEW SIGNAGE IS INSTALLED, GENERAL CONTRACTOR WILL PERFORM PATCH, REPAIR, AND PAINTING WORK NOTED IN PLANS AFTER NEW SIGNAGE IS INSTALLEDFOR STORES THAT REQUIRE STRUCTURAL MODIFICATIONS OR REPAIRS FOR INSTALLATION OF NEW EXTERIOR SIGNAGE, A TEMPORARY BANNER WILL BE INSTALLED BY THE EXTERIOR SIGN COMPANY PRIOR TO REMOVAL OF EXISTING EXTERIOR SIGNAGE. BANNER WILL REMAIN IN PLACE UNTIL ALL MODIFICATIONS AND/OR REPAIRS HAVE BEEN COMPLETED AND NEW SIGNAGE IS INSTALLED. GC SHALL PRIORITIZE MODIFICATIONS/REPAIRS REQUIRED FOR INSTALLATION OF NEW EXTERIOR SIGNS WHILE EXTERIOR SIGN COMPANY IS ON SITETEMPORARY BANNER WILL BE APPROXIMATELY 125 SF (5'X25').EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED, COORDINATED, AND COMPLETED DURING WEEK 6 OF THE CONSTRUCTION SCHEDULE.GENERAL CONTRACTOR RESPONSIBILITIESBY END OF FIRST WEEK OF CONSTRUCTION, REVIEW EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH SIGN ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM CONSTRUCTION MANAGER TO SUBMIT RFI IN ACCORDANCE WITH SECTION 01255. NOTE DIFFERENCES IN CONSTRUCTION, INCLUDING DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR CLARIFICATION.VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE. REFER TO ELECTRICALMAKE FINAL TERMINATIONS ON LIGHTED SIGNAGESIGNAGE CONTRACTOR RESPONSIBILITIESREMOVE ALL SIGNAGE WITH THE EXCEPTION OF TENANT SIGNAGE, UNLESS NOTED OTHERWISE.FURNISH SPECIFIED CONDUIT FOR LIGHTED SIGNAGE.MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL CONDUIT, AND SEAL PENETRATIONS PER SPECIFICATION SECTION 07900.INSTALL SIGNAGE PER DETAILS ON SHEET A2.132.84 SFWHITE PLASTIC LETTERSPLASTIC LETTERS MATCH SW #6904 "GUSTO GOLD"2'-6"4'-5 7/16"4'-1"INTERNALLY ILLUMINATED18.18 SFNOTE TO SIGN INSTALLER:ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.NOTE:ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR MINIMUM OF 8" ABOVE DECKELECTRICAL PENETRATIONS (TYP) FIELD VERIFY EXACT LOCATIONS SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONSREF BLDG ELEVATIONSCENTER OF SIGN14'-5 3/4"5OGPA2.1THROUGH WALL PROTECTION TUBE FURNISHED BY WALMART INSTALLED BY SIGN CONTRACTOR PER MFR RECOMMENDATIONSFULL BED OF MULTI-COMPONENT SEALANT ATPERIMETER OF CONDUIT BYSIGN INSTALLERINSTALL LETTER BACKPRIOR TO INSTALLATIONBY SIGN INSTALLERINDIVIDUAL PLASTICILLUMINATED CHANNELLETTERS BY SIGNSUPPLIERINSTALL LETTER FACESW/ SET SCREWS, TYP BYSIGN INSTALLERLOCATE ANCHORS ANDWIRING/CONDUIT PENETRATIONSPER SIGN ATTACHMENT TEMPLATEPROVIDED BY WALMARTSEALANT ALL AROUNDELECTRICAL TO JUNCTION BOXREMOTE POWER SUPPLY ENCLOSURE PROVIDED BY SIGN CONTRACTORHILTI HPS 1/4" X 1 5/8" SLEEVE ANCHOR PROVIDED BY WALMART AT EACH SIGN CONNECTION POINT INSTALLED BY SIGN CONTRACTORLOW VOLTAGE WIRE INSTALLED BY SIGN CONTRACTORSHEET NOTESP5E1.2.3.PAINT DOOR HOODS, HOLLOW METAL STEEL DOORS AND FRAMES, GUTTERS AND DOWNSPOUTS, EXPOSED METAL FLASHING, HANDRAILS, AND EXPOSED MISCELLANEOUS STEEL TO MATCH ADJACENT BUILDING COLOR UN0PAINT ROOF ACCESS LADDERPAINT ALL EXTERIOR BOLLARDS TO MATCH EXISTING COLOR UNLESS NOTED TO RECEIVE PLASTIC BOLLARD SLEEVE. LINTEL REF STRUCGRIND CMU SMOOTHGRIND CMU SMOOTHCONT SEALANT AROUND PERIMETERFULLY ADHERED WATERPROOFING MEMBRANEGALVANIZED SHEET METAL CLIP AT FACE OF WALL AROUND PERIMETER OF OPENING20 GA GALVANIZED SHEET METAL SCUPPER IN FULL BED OF SEALANT PAINT TO MATCH ADJ WALLTYP CONDITIONGALVANIZED ANCHORS WITH NEOPRENE WASHERS AT 6"OCCONT SEALANTGALVANIZED SHEET METAL POP RIVET AND SOLDER ALL AROUNDEXTEND SCUPPER PAST WALL 1 1/2" MINMEMBRANE FLASHING3 1/8"GROUT COURSE BELOW SCUPPER SOLID8-OGPA2.117/32"2"REF ROOF PLAN2"2"PLANREF2"CONT SEALANT AROUND SHEET METAL FLASHINGWALL OPENING9OGPA2.11"5"9"WALL OPENING22 GA GALVCONDUCTORHEADDOWNSPOUT10"X10"12" DEEPHEADCONTINUOUS SEALANTAROUND METAL FLASHINGCLIP4"5"5"1'-8"MAIN SCUPPER 8"H x 9 1/2" WOVERFLOW SCUPPER6"H x 9 1/2" W, TYP OF 22'-0"2'-0"℄℄℄ROOF LEVEL+2"ROOF LEVELFOR CONDUCTOR HEADAT DOWNSPOUT-REF11OGPA2.1architecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 668STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:PROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKC:\Users\JonTannehill\Documents\02516_Renton_WA_150_R_ARCH_V20_OGP_jdt3698.rvtRENTON, WASHINGTON10.09.2020RENTON, WASHINGTONSTORE NO.2516-249JOB NUMBER: 2019.0203JTSBD15008.28.202010.09.2020ENLARGEDOGPELEVATIONSOGPA2.1 1/8" = 1'-0"1OGP NORTH ELEVATION 1/8" = 1'-0"2OGP EAST ELEVATION 1/8" = 1'-0"3OGP WEST ELEVATION 3/4" = 1'-0"6EXPANSION ROOF LADDER WALL SECTION 3/4" = 1'-0"7EXPANSION ROOF LADDER SECTION BOTTOM 1/4" = 1'-0"4SIGNAGE 1/4" = 1'-0"4APICKUP SIGN MOUNTING DIAGRAM 1 1/2" = 1'-0"5SIGNAGE ATTACHMENTCOLOR LEGENDM1 SADDLE TAN INTEGRALLY COLOREDCMUP5E SAFETY YELLOWP134E LIGHT GRAYP135E MEDIUM GRAY3KEYNOTES4.04CONTROL JOINT, TYP, REF STRUCTURAL4.08SPLIT FACE CMU4.09SMOOTH FACE CMU 1 1/2" = 1'-0"9THROUGH SPLIT FACED WALL SCUPPER 1 1/2" = 1'-0"8SCUPPER ELEVATION 3/4" = 1'-0"11CONDUCTOR HEAD 1/2" = 1'-0"10SCUPPER ELEVATION3 12.18.2020 CCD#3