Loading...
HomeMy WebLinkAboutR-40833600 I O w I- FV-4" 2y2" *NOTE: WHEN RISER EXTENSIONS ALL STEEL PER ARE USED, THE PLANT SHOULD %4" (#6) REBAR CAN BE CUT FLUSH — ° ASTM A36 CUT 3" FROM THE SIDE RAILS AS (4) %6" FILLET WELDS FROM LADDER RAILS TO OUTSIDE OF RAIL SHOWN EACH ANGLE CORRUGATION AND RUNGS (BAR LENGTH = 16%4") OR BAR CAN CREST (2 WELDS EACH SIDE) EXTEND BEYOND RAIL%"± ~ FABRICATION TOLERANCE: ±%4" ° FLAT BAR AND REBAR: MILL 3/8„ TOLERANCE APPLIES (4) L3" x 3" x 3/6" RISER TYP. 5%2" LONG IV I 7 T 01 _ 6" FROM RUNG TO it 12" TYP. RISER JOINT HOLE w/ 3Y4' REBAR RUNG, *3" FROM BOTTOM OF LADDER O CENTER TO CENTER RUNG SPACING co WELD REBAR TO RUNG ON RAIL TO RISER JOINT V-4" OUTSIDE OF STEEL RAIL (2)%4" FILLET WELDS 1" LONG FROM EACH ANGLE 2%2" x 3/8" FLAT BAR SIDE RAIL TO LADDER RAIL PLAN SIDE PLAN NOTES: 1. LADDERS CAN BE MADE IN 20'-0" STANDARD LENGTHS AND CUT TO FIT *3" FROM TOP OF LADDER +I 2. ALL MATERIAL TO MEET ASTM A36 RAIL TO RISER JOINT O 3. LADDER TO BE HOT DIPPED GALVANIZED PER ASTM A-123 AFTER 6" FROM RUNG TO FABRICATION IS COMPLETE RISER JOINT STANDARD LADDER DETAIL NOT TO SCALE PART NO. HALAGVL16 — PROVIDE MINIMUM OF 4 ATTACHMENT — — ANGLES (2 ON EITHER SIDE OF LADDER RAIL) _ ' — — _ A TO CONNECT LADDER TO RISER EXTENSION RISER w/ LADDER AND STEPS IF EXTENSION IS REQUIRED _ LADDER RAILS AND RUNGS RISER NORMALLY CMP WITH 2%3' x%z" CORRUGATIONS (4) %6" FILLET WELDS RISER w/ LADDER (4) %6" FILLET WELDS FROM EACH ANGLE CORRUGATION CREST FROM EACH ANGLE TO AND STEPS CORRUGATION CREST (2 WELDS EACH SIDE)— (2 WELD EACH SIDE) _ (2)%4" FILLET WELDS 1" LONG _ _ _ ATTACHMENT ANGLE O L3" x 3" x %6" L3" x 3" x 3/6"— L5" x 3" x %4" x 16" LONG AT V-0" MINIMUM OF 4 ANGLES PER 5%2" LONG 5%2" LONG SPACING. LONG LEG TO LADDER SECTION, (2 EACH SIDE OF MAINLINE CMP �_ PROJECT OUT. WELD TOP LADDER) 6' MAX. SPACING AND BOTTOM OF 3" LEG TO EACH VERTICALLY 22/ x %2, 5 x 1, 3 x 1, ETC. MAX. CORRUGATION CREST (THESE ANGLES SHOULD BE USED d FOR LARGER DIAMETER MAINLINES WHERE ADDITIONAL SECTION A -A STEPS ARE NEEDED) LADDER RAILS NOTE: AND RUNGS THIS DRAWING IS INTENDED TO APPLY TO LADDERS INSTALLED IN RISERS HAVING A DIAMETER OF 30" OR ELEVATION LARGER. DUE TO SPACE CONSTRAINTS AND LIMITED ACCESSIBILITY, THE PRACTICALITY AND SUITABILITY OF UTILIZING RISERS SMALLER THAN 30" DIAMETER RISER LADDER DETAIL AND/OR INCORPORATING LADDERS IN THESE SMALLER NOT TO SCALE DIAMETER RISERS SHOULD BE ADDRESSED BY THE OWNER AND PROJECT ENGINEER R-408336 The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by ® ® PROJECT No.: SEC. No.: DATE: Contech Engineered Solutions LLC("Contech"). Neither this ��I/� �\I/<V�iCiAV �� �� 624723 010 2/28/2020 drawing, nor any part thereof, may be used, reproduced or C741FNTECH �" '� ' ��wx 24 PERFORATED UNDERGROUND RETENTION SYSTEM - 624723-010modiied in any manner without the prior written consent of �.►, �` `� = = DESIGNED: DRAWN: Contech. Failure essly comply claimssdone a[the yorruser's ponsibrisk tyforand ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS FUPC (FUNDAMENTALIST UKRANIAN PENTECOSTALIST CHURCH) KET JPC/DJB Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the dwww.ContechES.com RENTON,WA CHECKED: APPROVED: supplied information upon which CONTECH JMD JMD the drawing is based and actuallfield conditions are encountered PROPOSAL to siteechim immediately re-evaluation must be Contact 11815 NE Glenn Widing Drive, Portland, OR 97220 SITE DESIGNATION: FUPC SUBBASIN #1 to Con tech immediately for re-evaluation of the design. Contech SHEET NO.: accepts no liability for designs based on missing, incomplete orEARIJDATE REVISION DESCRIPTION B 800-548-4667 503-240-3393 800-561-1271 FAX DRAWING 49 OF 65 inaccurate information su lied 1), others. BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. ABOSSEIN ENGINEERING (AE) CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL FIELD VERIFY GRADES, UTILITIES AND ALL OTHER EX FEATURES & CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN &/OR PLANS CANNOT BE CONSTRUCTED AS SHOWN, CONTACT AE PRIOR TO CONSTRUCTION. uf Call before you dig PERMIT SUBMITTAL SURVEYED: GEODETIC SURVEYING SCALE: SERVICE VERTICAL: NWD 19ee AS INDICATED HORIZONTAL• NAD 1983/1991 DESIGNED: ON DRAWING DRAWN: ONE INCH DATUM CHECKED: AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) CITY OF ,R RENTON • Planning/Building/Public Works Dept. MA [1106"110SA IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Nathan Janders 03/19/2020 FIRST UKRAINIAN PENTECOSTAL CHURCH 3811 NE 21 ST ST RENTON, WA 98056 SITE DESIGNATION: FUPC SUBBASIN #1 DATE 02-25-20 FIELDBOOK: PAGE: 49 65 H H 00 T Q J 2 U OC D U J Q U) O U LU Z LU IZ Z Q Z_ Q I— V ) H