Loading...
HomeMy WebLinkAboutT-40830200 O T O rr F__ 0.5 0.8 1 1.1 1.5 1.8 12.0 2.2 2.4 2.7 3.0 3.3 3.5 3.6 3.6 3.3 3.1 2.8 2.5 2.3 \1.9 1.5 1.1 1 0.8 0.5 0.4 0.2 0.2 0.1 0.5 0.8 1.2 1.5 1.8 2.1 2.4 2.7 3.1 3.6 4.0 4.2 4.2 4.2 4.0 3.7 3.2 2.8 2.4 20 1.6 1.2 0.8 ,0.6 0.4 0.2 0.2 0.1 1 0.6 0.8 1.2 1.5 1.8 2.1 2.5 2.9 3.5 AME4.21ATST 4.2 4.2 4.1 3.5 2.9 2.4 2.0 1.6 1.2 0.8 ;.6 0.4 0.2 0.2 0.1 0.6 0.8 1.2 1.5 1.8 2.2 2.6 3.1 3.7 4.1 4.3 3.8 3.2 3.2 3.8 4.1 3.7 3.1 2.5 20 1.6 1.2 0.8 0.6 0.4 0.2 0.2 0.1 -0.6-- 0.8 1.2 -1.5 - -1.8 2.2 2.6 3.1 3.6 4.1 4.2 3.4 2.8 2.7 3.3 4.0 3.7 3.0 2.4 .9 1.5 1.1 0.8 0.6 0.4 �0. 0.2 0.1 SD SD SID SD SO SD SD - ST1- - -- - - - - - SD SD Sp SD -- - - - - �I k7_\\ziF 0.6 8 1. 1.5 1.8 2.1 2.6 3.0 3.4 3.9 3.9 3.4 D 3.0 SD SD .7 SD 3.5 SD 2.8 2.3 1.8 1.5 1.1 _Os8---0.5---0.3 SID �1- Sp n_1s` \ - i 0.5 0$ - 1.1 4 1.7 2.1 2.5 2.9 3.1 3.6��4.8 4.3 3.7 3. /1���3.5 2.6 2.1 1.7 1.4 1. 0. 0.5 0.3 0._ 1 0.1 I 0.5 0.8 1.1 1.4 1.7 2.0 2.4 2.7 2.9 3.3 3.9 4.4 4.2 3.7 3.3 3.1 2.8 \�2.4 .0 1.6 1.3 1 0 0.7 0.5 0.3 0.2 0.1 0.1 I I 0. 0.7 1.1 1.4 1.6 1.9 2.3 .3 3.0 2.8 2.6 .2 1.8 1.6 1.3 .9 0.7 0.4 0.3 0.2 0.1 0.1 I a I I - I a z I � I PHO TOME TRI C PLAN SCALE: 1/8" = 1'-0" NORTH NE21STST Z STREET LIGHT PER CITY STANDARD PROVIDE NEW LIGHT FIXTURE & POLE PROVIDE NEW CONCRETE - - - - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ BASE PER CITY OF - so so so so o so _ _ RENTON STANDARDS so so so so so - - - �-- APPROXIMATE LOCATION OF EXISTING ST1 POWER CABINET. _ PROVIDE_ j \ wli UIl/ \ D IIIi�F sD (1) 2 PVC ALL TRENCHING, CONDUIT AND JUNCTfON BOXES NECESSARY - - - SCHEDULE 80 CONDUIT TO MAKE CIRCUIT CONNECTIONS GROUND = WITH (3) #8 CU THWN DWG J1 rlI 1 -/r 1 \ --- _ - ---------------- ;------- �. Ilk- TRENCH DEPTH MIN. 24" // APPROXIMATE LOCATION OF EXISTING NEW UG JUNCTION BOX TO TOP OF CONDUIT (TYP.) FIELD VERIFY CITY OF RENTON ELECTRICAL CABINET 009B. LOCATED AND INSTALLED LOCATION PRIOR INSTALL ONE (1) 2" SCHEDULE 80 PVC CONDUIT F RENTON TO BID. FROM NEW STREET LIGHT TO EXISTING TYPE 1 PER CITY O STANDARD & 124 JUNCTION BOX LOCATED DIRECTLY EAST OF THE SERVICE CABINET 009B. PULL NEW CIRCUIT USING i THREE (3) #8 AWG CU. WIRE FROM STREET LIGHT TO EXISTING SERVICE CABINET. NOTE THERE IS EXISTING CONDUIT BETWEEN THE EXISTING JUNCTION BOX AND THE SERVICE CABINET. i I - Terra Vista N W Consulting Engineers J204 SMOKEY PO/NT OR, 1207 ARZ/NGTON, WA 9822,Y J,60-691-9272 #W TERRAWSTANKfCOM PO WER PLAN SCALE: 1/8" = 1'-0" 9s� �A 08/06/2024 I� It( PERMIT SUBMITTAL 03-13-19 SURVEYED: PERMIT SUBMITTAL WITH CIVIL CHANGES 08-05-19 DESIGNED: PERMIT SUBMITTAL CITY COMMENTS 02-05-19 JBW DRAWN: CHECKED: AA NO. REVISION BY DATE APPR APPROVED: SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CONSTRUCTION NOTES 1. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 2. CONTRACTOR TO CONTACT CITY ELECTRICAL INNPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 3. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 4. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOLD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION 5. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIXE THE STREET LIGHTING. 6. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL ISNPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 7. REMOVE AND DISPOSE OF EXISTING STREET LIGHT. SALVAGE EXISTING LUMINARIES HEADS, AND ASSOCIATED MOUNTING HARDWARE AND PROVIDE TO CITY OF RENTON. 8. FURNISH AND INSTALL NEW FOUNDATION AND LUMINARIES. SEE LUMINAIRES SCHEDULE ON SHEET E1.0. 9. RESTORE DAMAGED SIDEWALK RELATED TO NEW CONDUIT AND JUNCTION BOX. 10. ALL NEW PVC CONDUIT CONTAINING CONDUCTORS SHALL CONTAIN GROUNDWIRE. GROUND WIRE SHALL MATCH LARGEST CONDUCTOR (MIN#8 AWG). 11. ALL CONDUIT SHALL BE RIGID PVC SCH40 EXCEPT UNDER TRAVELED WAY (ROADWAY CROSSING). CONDUIT SHALL BE RIGID PVC SCH 80. 12. PROVIDE LOCATE WIRE AND PULL WIRING IN ALL NEW EMPTY CONDUIT. CALL 811 (2) BUSINESS DAYS BEFORE YOU DIG (UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE) CITY OF RENTON V'R vulv Planning/Building/Public Works Dept. GENERAL PHOTOMETRIC SCHEDULE AVERAGE 2.03 FOOT-CANDLES MAXIMUM 4.8 FOOT-CANDLES MINIMUM 0.1 FOOT-CANDLES MINIMUM TO MAXIMUM 0.01 FC RATIO MAXIMUM TO MINIMUM 67.18 FC RATIO AVERAGE TO MINIMUM 28.38 FC RATIO N] Ln N O O O 06 T a .J U rr U J a H T-408302 0 U IN COMPLIANCE WITH CITY OF RENTON STANDARDS w (- DEVELOPMENT ENGINEERING AO%z � w Nathan Janders 03/19/2020 0- z a NT PLANNING FAngelea z Weihs07/23/2019 ' a FIRST UKRAINIAN PENTECOSTAL CHURCH DATE: 2/14/20 Er Y 3811 NE 21 ST ST OOK: RENTON, WA 98056 PAGE: PAGE: cn DRAWING NO: STREET LIGHTING - POWER & PHOTOMETRICS ESL2.0 I= SHEET: 38 OF: 65