Loading...
HomeMy WebLinkAbout216.50RUNOFF RUNOFF SPILLWAY NOTES: 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.PLACE CURB TYPE SEDIMENT BARRIERS ON GENTLY SLOPING STREET SEGMENTS, WHERE WATER CAN POND AND ALLOW SEDIMENT TO SEPARATE FROM RUNOFF. 5.SANDBAGS OF EITHER BURLAP OR WOVEN GEOTEXTILE FABRIC, SHALL BE FILLED WITH GRAVEL, LAYERED AND PACKED TIGHTLY. 6.LEAVE A ONE SANDBAG GAP IN THE TOP ROW TO PROVIDE A SPILLWAY FOR OVERFLOW. 7.INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT. SEDIMENT AND GRAVEL MUST BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. 8.CURB AND GUTTER BARRIER PROTECTION MAY ONLY BE USED IN LANES NOT OPEN TO TRAFFIC. BACK OF SIDEWALK CURB INLET CURB FACE GUTTER DRAIN GRATE SANDBAGS TO OVERLAP ONTO CURB GRAVEL FILLED SANDBAGS STACKED TIGHTLY CURB AND GUTTER BARRIER PROTECTION STD. PLAN - 216.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT