HomeMy WebLinkAbout220.10FLEXIBLE PIPE NOTES: 1.PROVIDE UNIFORM SUPPORT UNDER BARRELS. 2.HAND TAMP UNDER HAUNCHES. 3.DIRECTLY OVER PIPE, HAND TAMP ONLY. 4.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 5.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 6.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. SEE NOTE 4, LIMIT OF PIPE ZONE 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 5 FLEXIBLE PIPE PIPE TYPE MINIMUM COVER (FT)PUBLIC?PRIVATE?ALLOWED IN ZONE 1 OF THE APA? LINE CORRUGATED POLYETHYLENE PIPE (LCPE)2.0 YES YES YES CORRUGATED POLYETHYLENE PIPE (CPE) - TRIPLE WALL 2.0 YES YES YES POLYVINYL CHLORIDE PIPE (PVC)3.0 YES YES YES SOLID WALL HIGH DENSITY POLYETHYLENE PIPE (HDPE)2.0 YES YES YES POLYPROPYLENE PIPE (PP) - DUAL WALL 2.0 YES YES YES DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 6 PIPE ZONE BEDDING AND COMPACTION - FLEXIBLE PIPE STD. PLAN - 220.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT