HomeMy WebLinkAbout221.00NOTES:
METAL PIPE
4H:1V
O
R
S
T
E
E
P
E
R
4H:1V
O
R
S
T
E
E
P
E
R
4H:1V
O
R
S
T
E
E
P
E
R
CONCRETE PIPE
THERMOPLASTIC PIPE
1.THE CULVERT ENDS SHALL BE BEVELED TO MATCH THE EMBANKMENT OR DITCH SLOPE AND SHALL NOT BE
BEVELED FLATTER THAN 4H:1V. WHEN SLOPES ARE BETWEEN 4H:1V AND 6H:1V, SHAPE THE SLOPE IN THE
VICINTIY OF THE CULVERT END TO ENSURE THAT NO PART OF THE CULVERT PROTRUDES MORE THAN 4"
ABOVE THE GROUND LINE.
2.FIELD CUTTING OF CULVERT ENDS IS PERMITTED WHEN APPROVED BY THE ENGINEER. ALL FIELD-CUT METAL
CULVERT PIPE SHALL BE TREATED WITH TREATMENT AS SHOWN IN WSDOT STD. SPECIFICATION 9-05.4(3).
DRAWN BY: MARK SUJKA
4" MAX.
END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE
(SEE WSDOT STD. SPEC. 7-02.3(1))
4" MAX.
4" MAX.
END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE
(SEE WSDOT STD. SPEC. 7-02.3(1))
END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE
(SEE WSDOT STD. SPEC. 7-02.3(1))
BEVELED END SECTIONS
STD. PLAN - 221.00
PUBLIC WORKS
DEPARTMENT
APPROVED:
DATEGregg Zimmerman
Public Works Administrator
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
9/28/2018 | 9:45 AM PDT