HomeMy WebLinkAbout221.00NOTES: METAL PIPE 4H:1V O R S T E E P E R 4H:1V O R S T E E P E R 4H:1V O R S T E E P E R CONCRETE PIPE THERMOPLASTIC PIPE 1.THE CULVERT ENDS SHALL BE BEVELED TO MATCH THE EMBANKMENT OR DITCH SLOPE AND SHALL NOT BE BEVELED FLATTER THAN 4H:1V. WHEN SLOPES ARE BETWEEN 4H:1V AND 6H:1V, SHAPE THE SLOPE IN THE VICINTIY OF THE CULVERT END TO ENSURE THAT NO PART OF THE CULVERT PROTRUDES MORE THAN 4" ABOVE THE GROUND LINE. 2.FIELD CUTTING OF CULVERT ENDS IS PERMITTED WHEN APPROVED BY THE ENGINEER. ALL FIELD-CUT METAL CULVERT PIPE SHALL BE TREATED WITH TREATMENT AS SHOWN IN WSDOT STD. SPECIFICATION 9-05.4(3). DRAWN BY: MARK SUJKA 4" MAX. END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) 4" MAX. 4" MAX. END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) BEVELED END SECTIONS STD. PLAN - 221.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT